DLED4R DLED6R INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
SAFETY INSTRUCTIONS
WARNING: Risk of fire or electric shock. LED retrofit Kit installation requires knowledge of luminaires electrical systems. If
not qualified, do not attempt installation. Contact a qualified electrician.
WARNING: Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the
input rating of the luminaire.
WARNING: Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING
DLED Retrofit unit is designed to fit nominal Existing
Housings with openings of 4” (DLED4R) or 6” (DLED6R).
See the list of compatible housing provided on page 2.
1.
Thread the E26 Socket Adaptor into Existing
Housings Medium Base Socket.
2.
Connect the orange Wire Connector of the E26
Socket Adaptor to DLED4R or DLED6R connector.
3.
Carefully route all wires into Existing Housing (Fig.
2). Taking care not to pinch wires, squeeze either
Friction Blades (DLED4R) or Torsion Spring Arms
(DLED6R) and push up DLED4/6R.
4.
Push up on DLED4/6R until it is flush to the ceiling
surface.
DLED4R
DLED4R
DLED6R
DLED6R
E26 Socket Adaptor
Wire Connector
Friction
Blade
Torsion
Spring Arm
5.10”
7.39”
Fig. 1
DLED4R DLED6R INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
DLED4RR DLED6RR IN 0218
Easy Answers
rabweb.com
Visit our website for product info
Tech Help Line
Call our experts - 888 722-1000
e-mail
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2018 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
DLED4R
DLED6R
Medium Base Socket
Existing Housing
Fig. 2
WIRING
WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp
objects.
Fixture operates at 120V 60 Hz and can be dimmed with
most forward phase incandescent dimmers. For a list of
compatible dimmers see www.rabweb.com
1.
Screw in medium base socket adaptor.
2.
Connect GROUND wire from DLED fixture to the
existing housing with # 8 screw provided to any
existing housing hole as shown or drill a new 1/8”
diameter hole.
3.
Plug in wire connector between socket adaptor and
DLED fixture.
TROUBLESHOOTING
Check that the line voltage at fixture is correct.
1. Check that the socket adaptor is properly seated in the socket.
2. Do not attempt to modify the socket in any way.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to
touch. Do not clean or maintain while fixture is energized.
1. Clean lens & fixture with non-abrasive cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the LED.
UL CLASSIFIED FOR RETROFIT
COMPATIBILITY
Check that the existing housing is one of the following
compatible fixtures.
1.
Retrofit has an E26 Edison screw-base.
2.
DLED4R and DLED6R can be used in existing housings
with opening of 4 or 6”. These fixtures are UL Classified
for retrofit in the following housings:
•
Halo: Housing Series H99TAT
•
Elite: B4, B4IC, BL4_Baffle, ID4-AT
•
Nora: NS-401QAE, NS-401QAT, NSR-404QAT
• Halo: Housing Series H7x, H27x, ET7x, Ei7x, ET27x,
EI27x. Halo H750ICAT, H750RICAT, H750T and
H750TCP series recessed LED housings.
• Juno:IC22, IC22R, IC22W, IC22S, IC23, IC23W, IC21,
IC21R, TC2, TC2R
• Capri: CR1, PR1, QL1, R9ASIC
• Progress: P87-AT, P86TG
• Lithonia: L7X, L7XP
• Thomas: PST, R9ASIC/PS9RM
• Prescolite: IBXS
• Commercial Electric: H3
• Elco: EL71CA
• Elite: B6IC-AT-W
DLED4R DLED6R INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
SAFETY INSTRUCTIONS
WARNING: Risk of fire or electric shock. LED retrofit Kit installation requires knowledge of luminaires electrical systems. If
not qualified, do not attempt installation. Contact a qualified electrician.
WARNING: Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the
input rating of the luminaire.
WARNING: Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING
DLED Retrofit unit is designed to fit nominal Existing
Housings with openings of 4” (DLED4R) or 6” (DLED6R).
See the list of compatible housing provided on page 2.
1.
Thread the E26 Socket Adaptor into Existing
Housings Medium Base Socket.
2.
Connect the orange Wire Connector of the E26
Socket Adaptor to DLED4R or DLED6R connector.
3.
Carefully route all wires into Existing Housing (Fig.
2). Taking care not to pinch wires, squeeze either
Friction Blades (DLED4R) or Torsion Spring Arms
(DLED6R) and push up DLED4/6R.
4.
Push up on DLED4/6R until it is flush to the ceiling
surface.
DLED4R
DLED4R
DLED6R
DLED6R
E26 Socket Adaptor
Wire Connector
Friction
Blade
Torsion
Spring Arm
5.10”
7.39”
Fig. 1
DLED4R DLED6R INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
DLED4RR DLED6RR IN 0218
Easy Answers
rabweb.com
Visit our website for product info
Tech Help Line
Call our experts - 888 722-1000
e-mail
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2018 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
DLED4R
DLED6R
Medium Base Socket
Existing Housing
Fig. 2
WIRING
WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp
objects.
Fixture operates at 120V 60 Hz and can be dimmed with
most forward phase incandescent dimmers. For a list of
compatible dimmers see www.rabweb.com
1.
Screw in medium base socket adaptor.
2.
Connect GROUND wire from DLED fixture to the
existing housing with # 8 screw provided to any
existing housing hole as shown or drill a new 1/8”
diameter hole.
3.
Plug in wire connector between socket adaptor and
DLED fixture.
TROUBLESHOOTING
Check that the line voltage at fixture is correct.
1. Check that the socket adaptor is properly seated in the socket.
2. Do not attempt to modify the socket in any way.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to
touch. Do not clean or maintain while fixture is energized.
1. Clean lens & fixture with non-abrasive cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the LED.
UL CLASSIFIED FOR RETROFIT
COMPATIBILITY
Check that the existing housing is one of the following
compatible fixtures.
1.
Retrofit has an E26 Edison screw-base.
2.
DLED4R and DLED6R can be used in existing housings
with opening of 4 or 6”. These fixtures are UL Classified
for retrofit in the following housings:
•
Halo: Housing Series H99TAT
•
Elite: B4, B4IC, BL4_Baffle, ID4-AT
•
Nora: NS-401QAE, NS-401QAT, NSR-404QAT
•
Halo: Housing Series H7x, H27x, ET7x, Ei7x, ET27x, EI27x
•
Halo H750ICAT, H750RICAT, H750T and H750TCP series
recessed LED housings.
•
Juno:IC22, IC22R, IC22W, IC22S, IC23, IC23W, IC21, IC21R,
TC2, TC2R
•
Capri: CR1, PR1, QL1, R9ASIC
•
Progress: P87-AT, P86TG
•
Lithonia: L7X, L7XP
•
Thomas: PST, R9ASIC/PS9RM
•
Prescolite: IBXS
•
Commercial Electric: H3
•
Elco: EL71CA
•
Elite: B6IC-AT-W