Vertiv RMPSU Quick Installation Manual

Text of the manual

Vertiv™ Rack mount power supply unit

Quick Installation Guide Before installing the Vertiv™ rack mount power supply unit (RMPSU), ensure the following: • You must have at least a single 1U (19 in.) rack slot with one or two power inputs. • For devices that require a 12 VDC power supply, you must have a 2 m link cable for installation. • For a device that requires a 5 VDC power supply, you must have a small converter module positioned close to the device being powered. 1. Rack mounting the RMPSU Slide the appliance into the vacant 1U space within a rack and secure each pre-installed bracket to the rack using two screws per side. 2. Installing the elongated rack bracket (optional) Place the elongated bracket on the rack, align the screw holes with the rack and fasten it in place with the supplied screws. NOTE: The elongated rack bracket allows the module to be mounted immediately behind the device. 3. Mounting power converter modules Mount each converter module close to the device to be powered by inserting the tabs of the module through the holes of the elongated rack bracket and slide the module to lock it in place. NOTE: The indentations on the side of the converter module allow you to attach the module to other surfaces using plastic cable ties. 4. Connecting a 5 V device Connect the 2.5 mm power jack of the module to the power input socket on the device. Connect the locking 3-pin plug to one of the power output sockets on the rear panel of the RMPSU main chassis. 5. Connecting a 12 V device Connect the locking 3-pin plug at one end of the link cable to the power input socket of the device, then connect the 3-pin plug at the opposite end of the cable to the power output socket on the rear panel of the RMPSU main chassis. 1 2 3 Rack Mounting the RMPSU Installing the Power Converter Module Power Converter Module Elongated Rack Bracket

VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA

© 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. 590-1521-501B 2 Vertiv™ Rack Mount Power Supply Unit Quick Installation Guide 6. Connecting a second power module Remove the fitted blanking plate to reveal the power module bay and slide the power module into the designated bay until the locking clip clicks, holding the module in place. Insert an IEC jumper cord into the socket on the module and turn on power. NOTE: Only use Vertiv™ power modules with the RMPSU. The RMPSU identifies non-authorized power modules as invalid. 7. Connecting to a network Use a shielded patch cable to link the Ethernet 10/100 network port on the front panel of the main chassis switch to a network switch. The default IP address is 192.168.1.22 and the default log in username and password are admin and password, respectively. NOTE: Both cross-over and straight connections are sup- ported. Vertiv™ Rack Mount Power Supply Unit 7 5 4 6 12 V Device 5 V Device Power Converter Module

Other Racks & Stands Manuals