Serai MT/B6 Installation Manual
Text of the manual
GATE AUTOMATION DIVISION
MT/B6 - SR 03.B6 - MOTOR FOR SWING GATES UP TO 6 METERS - 400Kg- 230 Vac
MT/C6 - SR 03.C6 - MOTOR FOR SWING GATES UP TO 6 METERS - 400Kg- 24 Vdc
Page 1/6
INSTALLATION MANUAL
MT/B6-C6 I E
!
Thank you for choosing a SERAI ELETTRONICA product, which we are confident will perform to your requirements.
Please be advised that y
MT/B6-C6 I E
Page 2/6
GATE
OPENING
AND CLOSING
END STOP
LATERAL VIEW
VIEW FROM BELOW
Fig. 3
Fig. 2
Fig. 1
430mm
885mm
70mm
130mm
90mm
1000mm
135mm
PM
!
!
SINCE 1965
BEFORE INSTALLING THE MOTORS
1- Ensure perfect right angles of the gate hinges to enable
totally smooth and balanced swing gate movement.
Otherwise the motor may be damaged when subject to
much h
MT/B6-C6 I E
BRACKET POSITIONING FOR INWARD OPENING
BRACKET POSITIONING FOR OUTWARD OPENING
C
PM
INWARD OPENING
OUTWARD OPENING
PM
B
C
885 mm
B
Fig. 5
Fig. 4
OPENING ANGLE 90°
OPENING ANGLE 100°
OPENING ANGLE 110°
B
C
B
C
B
C
260
190
250
200
230
170
240
210
220
180
200
160
240
220
210
190
190
170
230
230
220
220
180
180
220
240
190
210
170
Page 4 /6
MT/B6-C6 I E
SINCE 1965
Advice for wiring up in non-specialised environments.
1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or, alternatively,
use a 10A thermal magnetic circuit breaker switch.
2. Make all types of connection with the system disconnected from the power, i.e. with th
MT/B6-C6 I E
SINCE 1965
Fig. 14
Fig. 16
1
2
COVER "C"
3
FINAL INSTALLATION
13- Remove the motor from the brackets. Weld the front
bracket in its final position. Fix the rear bracket in its
final position. - Fig. 14 -
14- Refit the motor. Any differences in values B and C can
be compensated for using the 5 holes on the rear brac-
ket. - Fig. 9 -
15