SentexSystems CROWN JEWEL Advanced Features Programming Manual
Read Online
Read the SentexSystems CROWN JEWEL Advanced Features Programming Manual online using the built-in PDF viewer.
Text of the manual
Doc.. 6001141
Doc.. 6001141
Doc.. 6001141
Doc.. 6001141
Rev B
Rev B
Rev B
Rev B
CROWN JEWEL
CROWN JEWEL
CROWN JEWEL
CROWN JEWEL
ADVANCED FEATURES
ADVANCED FEATURES
ADVANCED FEATURES
ADVANCED FEATURES
PROGRAMMING GUIDE
PROGRAMMING GUIDE
PROGRAMMING GUIDE
PROGRAMMING GUIDE
TABLE OF CONTENTS
PART 1 PROGRAMMING OVERVIEW .....................................................................................1
A. INTRODUCTION .......................................................................................................................... 1
B. PROGRAMMING BASICS ............................................................................................................ 2
C. SETTING THE DATE AND TIME (STEP 27) ................................................................................ 3
D. SYSTEM RESPONSES................................................................................................................ 4
PART 2 TIME ZONES AND HOLIDAYS....................................................................................5
A. PROGRAMMING TIME ZONES (STEP 25) .................................................................................. 5
B. SETTING HOLIDAYS (STEP 28).................................................................................................. 5
PART 3 ENTRY CODES............................................................................................................6
A. CREATING AN ENTRY CODE (STEP 03).................................................................................... 6
B. DELETING AN ENTRY CODE (STEP 04) .................................................................................... 6
C. DELETING ALL ENTRY CODES (STEP 05) ................................................................................ 6
PART 4 VISITOR CALL FEATURES.........................................................................................7
A. SETTING THE VISITOR CALL DOUBLE RING (STEP 06) .......................................................... 7
B. SETTING THE MAXIMUM VISITOR CALL RING COUNT (STEP 07) .......................................... 7
C. SETTING TALK TIME (STEP 08) ................................................................................................. 7
D. ENABLING/DISABLING PULSE DIAL ACTIVATION (STEP 09)................................................... 8
E. ENABLING/DISABLING CALL WAITING (STEP 10) .................................................................... 8
F. CHANGING THE VISITOR CALL RESPONSE KEYS (STEP 34) ................................................. 8
G. VISITOR CALLS TO GUEST HOUSES........................................................................................ 8
PART 5 DO NOT DISTURB FEATURE .....................................................................................9
A. ACTIVATING THE DO NOT DISTURB UNTIL FEATURE (STEP 89)........................................... 9
B. CANCEL DO NOT DISTURB UNTIL (STEP 89) ........................................................................... 9
C. SETTING UP A DO NOT DISTURB SCHEDULE (STEP 11)........................................................ 9
D. DELETING A DO NOT DISTURB SCHEDULE (STEP 11) ......................................................... 10
E. ENABLING/DISABLING THE DO NOT DISTURB SCHEDULE (STEP 12)................................. 10
PART 6 GATE CONFIGURATION...........................................................................................11
A. SETTING THE MAIN GATE ACTIVATION TIME (STEP 23)....................................................... 11
B. SETTING AUXILIARY RELAY AND STATUS 2 INPUT CONFIGURATION (STEP 26) .............. 11
C. SETTING AUXILIARY RELAY ACTIVATION TIME (STEP 24)................................................... 12
PART 7 UNLOCK SCHEDULES .............................................................................................13
A. SETTING AN UNLOCK SCHEDULE FOR THE MAIN GATE (STEP 41).................................... 13
B. ERASING AN UNLOCK SCHEDULE FOR THE MAIN GATE (STEP 41).................................... 14
C. SETTING AN UNLOCK SCHEDULE FOR THE AUXILIARY RELAY (STEP 42) ........................ 14
D. ERASING AN UNLOCK SCHEDULE FOR THE AUXILIARY RELAY (STEP 42)........................ 15
E. ENABLING/DISABLING UNLOCK SCHEDULES (STEP 40) ...................................................... 15
PART 8 CALL FORWARDING ................................................................................................16
A. SETTING THE CALL FORWARDING NUMBER (STEP 14)....................................................... 16
B. ENABLING/DISABLING CALL FORWARDING (STEP 13)......................................................... 16
C. DELETING THE CALL FORWARDING NUMBER (STEP 14) .................................................... 16
D. SETTING THE CALL FORWARDING EXTENSION NUMBER (STEP 16 ) ................................ 17
E. SETTING THE CALL FORWARDING EXTENSION DELAY (STEP 15) ..................................... 17
F. DISABLE THE CALL FORWARDING EXTENSION DELAY (STEP 15)...................................... 17
G. MAXIMUM NUMBER OF VOICE MAIL DIGITS VISITOR MAY DIAL (STEP 17)........................ 17
H. CALL FORWARDING SCHEDULE (STEP 18) ........................................................................... 18
PART 9 SECURITY FEATURES .............................................................................................19
A. CHANGING THE UNIT PASSWORD (STEP 01)........................................................................ 19
B. VERIFYING THE UNIT PASSWORD (STEP 02)........................................................................ 19
C. ENABLING/DISABLING ALARM CALL (STEP 21) ..................................................................... 19
D. ALARM CALL NUMBER (STEP 22)............................................................................................ 20
E. DELETE ALARM CALL NUMBER (STEP 22) ............................................................................. 20
F. MAXIMUM NUMBER OF KEYPAD ERRORS (STEP 20)............................................................ 20
G. ENABLING DIRECT COMMANDS (STEP 35)............................................................................ 20
PART 10 IMMEDIATE CONTROL FUNCTIONS .....................................................................21
A. DO NOT DISTURB UNTIL FEATURE (STEP 89) ....................................................................... 21
B. CANCEL THE DO NOT DISTURB UNTIL FEATURE (STEP 89)................................................ 21
C. SPEAK THROUGH THE CROWN JEWEL MICROPHONE (STEP 90) ...................................... 21
D. CYCLE MAIN GATE (STEP 91).................................................................................................. 21
E. CYCLE AUXILIARY RELAY (STEP 92) ...................................................................................... 21
F. INITIATING SUSTAINED ACTIVATION OF MAIN RELAY (STEP 93)........................................ 22
G. INITIATING SUSTAINED ACTIVATION OF AUXILIARY RELAY (STEP 94).............................. 22
H. RELEASE MAIN GATE RELAY (STEP 95)................................................................................. 22
I. RELEASE AUXILIARY RELAY (STEP 96) .................................................................................. 22
J. RELEASE BOTH RELAYS (STEP 97)......................................................................................... 22
K. LATCH MAIN RELAY UNTIL SPECIFIED TIME (STEP 98)........................................................ 23
L. LATCH AUXILIARY RELAY UNTIL SPECIFIED TIME (STEP 99)............................................... 23
PART 11 OTHER FUNCTIONS ...............................................................................................24
A. SETTING ALTERNATE PREFIXES (STEP 36) .......................................................................... 24
B. RESTORING FACTORY SETTINGS (STEP 31) ........................................................................ 25
C. ENABLING/DISABLING THE NO-TELCO MODE (STEP 33) ..................................................... 25
D. RINGS BEFORE ANSWER (STEP 29)....................................................................................... 26
E. OVERRIDING TELEPHONE COMPANY ANSWERING SERVICE (STEP 43) ........................... 26
F. RESETTING THE UNIT (STEP 32)............................................................................................. 26
PART 12 MULTIPLE UNIT INSTALLATIONS .........................................................................27
A. PROGRAMMING MULTIPLE UNITS .......................................................................................... 27
B. SETTING THE UNIT NUMBER (STEP 38) ................................................................................. 27
C. VERIFY UNIT NUMBER (STEP 37)............................................................................................ 28
PART 13 DIRECT COMMANDS FROM THE RESIDENCE PHONE.......................................29
A. DIRECT COMMAND BASICS..................................................................................................... 29
B. DO NOT DISTURB UNTIL (STEP 89)......................................................................................... 29
C. CANCEL DO NOT DISTURB UNTIL (STEP 89) ......................................................................... 29
D. INITIATING AUDIO COMMUNICATION THROUGH THE CROWN JEWEL (STEP 90)............. 29
E. CYCLE MAIN GATE (STEP 91).................................................................................................. 30
F. CYCLE AUXILIARY RELAY(STEP 92)........................................................................................ 30
G. ACTIVATE MAIN RELAY (STEP 93) .......................................................................................... 30
H. ACTIVATE AUXILIARY RELAY (STEP 94)................................................................................. 30
I. DEACTIVATING MAIN RELAY (STEP 95)................................................................................... 30
J. DEACTIVATING AUXILIARY RELAY (STEP 96)......................................................................... 30
K. DEACTIVATING BOTH RELAYS (STEP 97) .............................................................................. 30
L. ACTIVATING MAIN RELAY UNTIL SPECIFIED TIME (STEP 98)............................................... 31
M. ACTIVATING AUXILIARY RELAY UNTIL SPECIFIED TIME (STEP 99).................................... 31
N. USING THE IN-HOUSE PAGING FEATURE.............................................................................. 31
APPENDIX A THE PROGRAMMING MENU ...........................................................................32
Copyright 2000
All Rights Reserved
This document is protected by copyright, and may not be copied or adapted without the prior written
consent of Sentex Systems. This document contains information proprietary to Sentex and such
information may not be distributed without the prior written consent of Sentex. The software and
firmware included in the Sentex Crown Jewel unit as they relate to this documentation are also
protected by copyright and contain information proprietary to Sentex
Sentex Systems
Chatsworth, CA
Visit us at www.sentexsystems.com
Page 1 of 33
PART 1
PROGRAMMING OVERVIEW
A. INTRODUCTION
The Crown Jewel is a single-line telephone entry system that connects directly to your telephone line.
When visitors call you through the Crown Jewel unit, the calls are not routed through the telephone
company. No telephone charges are generated.
The procedures in this manual assume that you have already read the manuals for your Crown Jewel
system (Crown Jewel Installation Guide, Doc. No. 6001145, and Crown Jewel Basic Programming,
Doc. No. 6001146). If not, please read the manuals before continuing.
You can program the following features on your Crown Jewel unit:
Visitor entry:
•
When the visitor presses the “#” key on your unit’s keypad, the Crown Jewel rings
your telephone.
•
You can communicate with the visitor and allow entry at the main gate by dialing 9.
•
If the Crown Jewel unit is controlling a second gate, you can dial 5 to allow entry.
Call Waiting:
•
If your telephone is in use when a visitor calls, the Crown Jewel will notify you. You
can put your current call on hold and speak with the visitor.
•
If you are talking with a visitor and you receive a phone call, the Crown Jewel will
notify you. You can put the visitor on hold while you take your new phone call.
•
If you forget that a call was on hold and hang up the phone, the Crown Jewel will
ring your telephone. When you pick up the phone, your call will be put through.
Entry Codes:
You can grant access through the use of 4-digit entry codes. You can program up
to 75 different entry codes to allow access through the Crown Jewel unit.
Time Zones:
You can restrict the use of entry codes by limiting the days and times that a code is
valid.
Call Forwarding:
The Crown Jewel unit can be programmed to dial an outside telephone number
(instead of ringing the house) when a visitor presses a “#” key on the front panel of
the unit. This feature allows you to grant access to a visitor from a remote location.
Do Not Disturb
The Crown Jewel can block visitor calls during time periods you specify. This
Feature
command can either be sent directly to the unit; or you can set up schedules that will
activate and deactivate this feature automatically.
Visitor calling
The Crown Jewel can be programmed to have a visitor call placed to a location
directly to a
other than the main residence, such as a guest house. The Crown Jewel has the
guest house, etc. capacity for three codes.
Timed control of
You can program the Crown Jewel unit to automatically activate, and
gate & auxiliary
later deactivate, any device controlled by the unit’s relays. For example, the
relays
Crown Jewel can automatically open the main gate up to twice per day and close it
later.
You can also program up to 10 holidays on which these schedules will not operate
unless you want them to.
Direct control of
You can activate the controlled gates or accessories can be activated directly
gates
from your tone dial telephone.
Off-site remote
You can program the Crown Jewel unit from a remote location, such as
programming
an outside tone dial telephone, or a personal computer with a modem.
Page 2 of 33
Doc. 6001141
Rev B
Gate monitoring: Your Crown Jewel installer can place sensors on the main gate to detect whether it
is closed. You can program the Crown Jewel to respond in the following ways if the
gate is forced open or is held open 60 seconds after it should have been closed.
1. Place an alarm call: The unit will ring a pre-programmed outside telephone
number and make a continuous “hi-low” sound.
2. Close a relay: If relay 2 is programmed as an alarm relay, the unit will close that
relay to activate the device connected to it. For example, you may have an installer
connect a siren, or Closed Circuit Television Camera.
Free exit through The unit can provide free exit through a controlled entry point.
a monitored gate
Transactions:
The Crown Jewel retains a record of the last 250 gate actions and programming
entries, including the time and date of the activity and, in the instance of entry codes
transactions, the person involved. Please ask your installing dealer for details on
how these records may be retrieved via modem.
B. PROGRAMMING BASICS
You can program the Crown Jewel from:
•
The keypad mounted on the face plate of the unit
•
The residence telephone; you will need a tone-dial telephone
•
A remote telephone; you will need to use a tone-dial telephone to call the residence
ENTER PROGRAMMING MODE
Begin by signalling the Crown Jewel unit that you want to enter programming mode.
From The Keypad
1.
Press the asterisk key three times (“✱✱✱”).
2.
The Crown Jewel is now ready to accept programming instructions.
From the Residence Telephone
1.
When you hear the dial tone, press the asterisk key three times (“✱✱✱”).
2.
Enter the six digit password. The unit will emit a high-pitched tone.
3.
Press the pound key (“#”). The tone will stop.
4.
The Crown Jewel is now ready to accept programming isntructions.
From a Remote Telephone
1.
Dial the residence telephone number.
2.
When the Crown Jewel picks up the call, press the asterisk key three times (“✱✱✱”).
3.
Enter the six digit pass word. The unit will emit a high-pitched tone.
4.
Press the pound key (“#”). The tone will stop.
5.
The Crown Jewel is now ready to accept programming instructions.
Page 3 of 33
PROGRAMMING THE CROWN JEWEL
Each programming command consists of: the programming prefix (usually “##”); a 2-digit step
number; the required digits of data; ending with the “#” (pound) key to terminate the programming
step. The step number tells the Crown Jewel which setting to change. The data is your new value for
that setting.
If the step and data information are valid, the unit will respond with 2 short beeps. If you do not hear 2
short beeps, the unit did not understand your input.
If you realize in the middle of an entry that you might have made an error, press the “✱” (asterisk) key
to cancel the command. Begin again with the step number.
Example: ##01123456#
Programming prefix: ##
Two-digit step number: 01 – set the unit password
Six-digit data: 123456 – the new password
End step: # - the pound key
EXIT PROGRAMMING MODE
To signal the Crown Jewel that you want to exit programming mode, press “00#” (two zeroes and the
pound key).
Keypad: the unit will disconnect.
Telephone (residence or remote): the unit respond with three short beeps. Hang up the phone.
C. SETTING THE DATE AND TIME (STEP 27)
The Crown Jewel unit contains an internal calendar and clock which is used for:
•
Time stamping of transactions
•
The Do Not Disturb feature
•
Entry codes with time zones
•
Gate unlock schedules
•
Call Forwarding schedules.
Be sure to set the current date and time before trying to use any of these features.
Format
27 + year + month + date + day of the week + hour + minute + “#”.
•
The year, month, date, hour and minute are entered as two digits.
•
The hour is entered in twenty-four hour format; for example, the time of 7:20 PM is
entered “1920”; the hour for 7:20 PM is entered “19”; the minutes are entered “20”.
•
The days of the week are numbered as follows:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
Example 27 + 94 + 09 + 28 + 4 + 15 + 30 + #
(sets the unit’s clock for 3:30 PM on Wednesday, September 28, 1994).
NOTE: The internal calendar automatically adjusts for leap years, but does not automatically adjust for
daylight savings time.
Page 4 of 33
Doc. 6001141
Rev B
D. SYSTEM RESPONSES
The Crown Jewel emits various audio tones or beeps to respond to input or to indicate certain
conditions. These tones and beeps will tell whether the Crown Jewel has understood your
programming instructions or Direct Commands.
Programming Responses:
•
2 short beeps - a programming step was valid
•
3 short beeps - the programming mode was exited
•
1 long beep - an input was not valid
•
2 long beeps - a duplicate entry code was entered
•
3 long beeps - the code memory is full
•
4 long beeps - the unit has reset or is powering up
•
busy signal - the line is busy or Do Not Disturb feature is in effect
Direct Command Responses:
•
5 short beeps - a gate is closing by command
•
10 short beeps - a gate is opening by command
Other Responses
•
1 short beep - a key was pressed on the main keypad
•
10 beeps (1 per second) - the talk time for a visitor call is lapsing and the unit will beep once per
second for the last 10 seconds unless the talk time is extended.
•
ring back - the unit is ringing the house
•
continuous hi-low tones - an alarm condition has been activated
silence
the keypad has struck out; the unit is being programmed from another source; or an alarm
condition exists
Page 5 of 33
PART 2
TIME ZONES AND HOLIDAYS
A. PROGRAMMING TIME ZONES (STEP 25)
The Times Zones feature allows you to set up time periods and days during which access is restricted
for entry codes. For example, the gardener’s entry code will only grant access on Mondays between
the hours of 9:00 AM and 3:00 PM.
You can program up to seven two zones, with two segments each.
Format
25 + time zone number + segment number + starting time + ending time + days of the week + “#”.
•
Time zone numbers range from 1 to 7 with two segments for each time zone (numbered
1 or 2).
•
Starting and ending times are four digits long in 24-hour format.
•
The days of the week are numbered as follows:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
Example 25 + 2 + 1 + 0800 + 1700 + 234568 + #
(sets time zone 2, segment 1 to start at 800 AM and end at 5:00 PM Monday through Friday
and holidays).
Note
•
To set up a time zone that extends past midnight and into the next day, create one
segment that runs until midnight (for example, Monday through Friday from 8 PM to 12
AM) and a second segment that starts at midnight on the following days (for example,
12AM to 4AM on Tuesday through Saturday).
•
If you want a time zone to be valid on holidays, you must also program that time zone to
be valid for a day of the week.
B. SETTING HOLIDAYS (STEP 28)
Holidays are special calendar dates which can be used to modify the action of:
•
Do Not Disturb Schedules
•
Gate Unlock Schedules
•
Entry Codes with Time Zones
•
Call Forwarding Schedules
For example, if New Year’s Day is set up as a holiday, then entry codes that would ordinarily be
allowed access will not be granted entry on January 1st. You can program up to 10 holidays.
Format
28 + holiday number + month + date + “#”
•
The holiday number is one digit (0 through 9).
•
The month and date are each entered as two digits.
Example 28 + 1 + 0101 + #
(sets January 1st as holiday number 1).
Page 6 of 33
Doc. 6001141
Rev B
PART 3
ENTRY CODES
The following steps enable you to program and delete entry codes. Entry codes can be used to gain
access without using a key or contacting you. The Crown Jewel unit has capacity for 75 entry codes.
You can program entry codes that open the main gate and are valid at all times. If you want to restrict
access, you can program entry codes to activate specific relays; and/or grant access only during
specified Time Zones (see Part 2, Section A).
A. CREATING AN ENTRY CODE (STEP 03)
Format
03 + entry code + relay code (optional) + time zone (optional) + “#”
•
Entry codes are four digits long, between the numbers 0000 and 9999 inclusive.
•
Relay Codes: 0 = Cycle default relay for its normal activation time
1 = Cycle main gate for its normal activation time
2 = Cycle auxiliary relay for its normal activation time
3 = Latch main gate open
4 = Latch auxiliary relay
5 = Release main gate
6 = Release auxiliary relay
7 = Release both
8 = Cycle both for normal activation times
9 = Latch both
•
Time Zones are one digit long.
Examples
Entry code for main gate, valid at all times: 03 + 2468 + “#”
(sets entry code 2468 to activate the main relay, valid at all times).
Entry code with relay code only: 03 + 3579 + 2 + “#”
(sets entry code 3579 to cycle the auxiliary relay for the normal activation time).
Entry code with Time Zone code only: 03 + 9631 + 3 + “#”
(sets entry code 9631 to cycle the default relay during Time Zone 3 only).
Entry code with relay code and time zone: 03 + 1234 + 1 + 2 + “#”
(sets entry code 1234 to cycle relay 1, valid during Time Zone 2).
Keypad associated relay code: 03 + 0 + “#”
(activates the relay associated with the keypad from which the code was entered). If a
"0" or no relay code is entered on the Crown Jewel keypad, relay 1 will activate; if
entered at the Auxiliary Keypad, relay 2 will activate.
B. DELETING AN ENTRY CODE (STEP 04)
This programming step erases an entry code from the unit’s memory.
Format
04 + entry code to erase + “#”
•
Entry codes are four-digits long.
Example
04 + 1234 + #
(erases entry code 1234 from the unit’s memory).
C. DELETING ALL ENTRY CODES (STEP 05)
This programming step will erase all the entry codes in the unit’s memory.
Format
05 + 101010 + “#”
Page 7 of 33
PART 4
VISITOR CALL FEATURES
A. SETTING THE VISITOR CALL DOUBLE RING (STEP 06)
Factory Setting: 2 (double ring).
Format
06 + ring type + “#”
•
Ring types:
1 = single ring
2 = double ring
Example 06 + 2 + #
(double ring)
B. SETTING THE MAXIMUM VISITOR CALL RING COUNT (STEP 07)
You can program the number of rings the unit will allow before it discontinues the call placed to the
residence.
Factory Settings: 12.
Format
07 + number of rings + “#”
•
Number of rings can be set from 1 to 24; this entry is 1 or 2 digits long.
Example 07 + 6 + #
(sets the unit to discontinue the visitor call after 6 rings to the house).
C. SETTING TALK TIME (STEP 08)
Sets the maximum length of a call that can be made by a visitor.
Factory Settings: 90 seconds.
Format
08 + number of seconds + “#”.
•
This length can be set from 15 to 250 seconds; the entry will be two or three digits long.
Example 08 + 120 + #
(sets the talk time to 2 minutes).
NOTES
1. When the Crown Jewel is calling the residence during a normal visitor call, the talk time
starts when the call is answered.
2. When the Crown Jewel is calling a Call Forwarding number, the talk time starts
immediately after the number is dialed.
3. When there are 10 seconds of talk time left, the unit will beep 1 once each second to
notify you. If you wish to extend the talk time, press “1” (one key) now.
Page 8 of 33
Doc. 6001141
Rev B
D. ENABLING/DISABLING PULSE DIAL ACTIVATION (STEP 09)
You can enable a resident to open the main gate by dialing “9” on a pulse (rotary) telephone in the
residence. You can also disable this feature.
Factory Setting: 0 (disabled).
Format
09 + pulse dial mode + “#”
•
This entry is one digit long.
0 = disable the Pulse Dial 9 feature
1 = enable the Pulse Dial 9 feature
Example
09 + 1 + #
(enables the Pulse Dial 9 feature).
NOTE
Pulse dialing cannot be used for any other visitor response, for programming, or for
direct commands.
E. ENABLING/DISABLING CALL WAITING (STEP 10)
You can enable or disable the Call Waiting feature.
Factory Setting: 1 (Call Waiting enabled).
Format
10 + Call Waiting mode + “#”
•
Call Waiting is one digit long:
0 = disable Call Waiting
1 = enable Call Waiting
Example 10 + 0 + #
(disables the Call Waiting feature).
F. CHANGING THE VISITOR CALL RESPONSE KEYS (STEP 34)
You can change the keys you press on your telephone keypad in response to visitor calls.
Factory Setting: 9521✱
“9” for Main Gate activation
“5” for Auxiliary Relay activation
“2” for Call Waiting Toggle Digit
“1” for Extend Talk Time Digit
“✱“ for Hang-up Key
Format
34 + main gate activation digit + auxiliary relay activation digit + call wait toggle digit +
extend talk time digit + hang-up digit + “#”
Example 34 + 1 + 2 + 6 + 7 + 8 + #
(Changes main gate activation digit to “1”, auxiliary activation digit to “2”, call waiting toggle
digit to “6”, extend talk time digit to “7”, and hang-up key to “8”).
NOTE
If you want to restore the response keys to the factory settings, simply enter “34#”.
G. VISITOR CALLS TO GUEST HOUSES
The Crown Jewel has the ability to let a visitor place a call to a location other than the main residence.
This feature is utilized when the visitor presses either “1#”, “2#”, or “3#” in the unit’s keypad.
Format
19 + dialing code number + telephone number + “#”
•
Dialing code number is one digit long; it may be 1, 2 or 3.
•
Telephone number may be up to 11 digits long.
Example
19 + 2 + 5551212 + #
(sets dialing code 2 to dial 555-1212 when 2# is pressed on the unit’s keypad).
Page 9 of 33
PART 5
DO NOT DISTURB FEATURE
The Do Not Disturb feature allows you to block visitor calls during specific times.
NOTE: Be sure you set the unit’s date and time before using the Do Not Disturb feature.
A. ACTIVATING THE DO NOT DISTURB UNTIL FEATURE (STEP 89)
You can use this feature block calls until a specific time. Call blocking begins immediately.
Format
89 + ending time + “#”
•
The ending time should be four digits long, in 24-hour format.
Example 89 + 0715 + #
(visitor calls will be blocked until 7:15 AM).
NOTE
This step temporarily overrides any Do Not Disturb Schedule that may be programmed.
B. CANCEL DO NOT DISTURB UNTIL (STEP 89)
The procedure cancels call blocking immediately.
Format
89 + 99 + “#”
•
Enter “99” as the ending time.
C. SETTING UP A DO NOT DISTURB SCHEDULE (STEP 11)
Use this programming step to block calls at regularly scheduled times.
Format
11 + day of the week + starting time + ending time + holiday option + “#”
•
Day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The starting and ending times should be 4 digits long, in 24-hour format.
•
The holiday option is one digit long:
0 = No schedule on holidays
1 = Use same schedule on holidays holiday
2 = Use schedule number 8 when this day falls on a programmed holiday
Example 11 + 2 + 2315 + 0830 + 1 + #
(sets a Do Not Disturb schedule for Mondays from 11:15 PM until 8:30 AM the following
morning and includes holidays).
Page 10 of 33
Doc. 6001141
Rev B
D. DELETING A DO NOT DISTURB SCHEDULE (STEP 11)
Format
11 + day of the week + 99 + “#”
•
Day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
Enter “99” for the starting time.
Example 11 + 2 + 99 + #
(Deletes the Do Not Disturb schedule for Mondays).
E. ENABLING/DISABLING THE DO NOT DISTURB SCHEDULE (STEP 12)
Use this programming step to temporarily disable or re-enable the Do Not Disturb Schedule.
Factory Setting: 0 (disabled).
Format
12 + Do Not Disturb mode (1 digit) + “#”
•
Do Not Disturb mode is one digit long:
0 = Ignore Do Not Disturb Schedule
1 = Enable Do Not Disturb Schedule
Example 12 + 1 + #
(Crown Jewel re-enables Do Not Disturb Schedule).
Page 11 of 33
PART 6
GATE CONFIGURATION
A. SETTING THE MAIN GATE ACTIVATION TIME (STEP 23)
You can program the time the main gate will remain activated.
Factory Setting: 10 seconds.
Format
23 + number of seconds + “#”
•
The number of seconds can be up to three digits long; it can be set for 1 to 250
seconds.
Example
23 + 35 + #
(sets relay 1 to remain activated for 35 seconds).
IMPORTANT NOTE
If this relay activates a gate operator with a momentary contact closure, set the relay activation time for
a short period (for example, 2 seconds). A longer activation time might cause the gate to repeatedly
open and close until the activation period has expired.
B. SETTING AUXILIARY RELAY AND STATUS 2 INPUT CONFIGURATION (STEP 26)
You can program the modes of operation of the auxiliary relay and the status 2 input.
The auxiliary relay can be used to:
•
Control a second gate
•
Bypass (shunt) an alarm sensor
•
Trigger an alarm device such as a siren
•
Activate an accessory such as CCTV
The status 2 input can be used as:
•
An exit request for the second gate
•
A sensor to detect the closed position of the main gate.
Factory Setting: 0 (Relay 2 is Control, Status 2 is Exit Request).
Format
26 + configuration number (0 through 5) + “#”
•
The configuration number is one digit long, 0 through 5:
Configuration
Number
Relay 2
Status 2
Video On
0
Control
Exit Request 2
1
Shunt
Position Sense 1
2
Alarm
Position Sense 1
3
CCTV
Position Sense 1
Manual
4
CCTV
Position Sense 1
Immediate
5
Control
Position Sense 1
Example
26 + 3 + #
(sets relay 2 for alarm and Status 2 for Position Sense 1).
SEE NOTES ON FOLLOWING PAGE
Page 12 of 33
Doc. 6001141
Rev B
NOTES
If the second relay is set to configuration number:
0
During a visitor call, the relay will activate when you dial a “5” and the call will terminate
or the relay will activate when the Exit Request Device has been activated.
1
The second relay will activate whenever the main relay activates to temporarily bypass
an alarm sensor monitoring this entry.
2
The second relay will activate upon an alarm condition (see Alarm Feature).
3
The closed circuit TV will activate when you dial a “5” on your telephone, but the visitor
call will not be terminated until you either grant access or dial a "✱" to terminate the call.
4
The closed circuit TV will activate when any key is pressed on the main keypad.
5
During a visitor call, the relay will only activate when you dial a “5” and then the call will
be terminated.
C. SETTING AUXILIARY RELAY ACTIVATION TIME (STEP 24)
You can program the amount of time the auxiliary relay will remain activated.
Factory Setting: 10 seconds.
Format
24 + number of seconds (up to 3 digits) + “#”
•
The number of seconds can be up to three digits; it can be from 1 to 250 seconds.
Example
24 + 5 + #
(sets relay 2 to remain activated for 5 seconds).
IMPORTANT NOTE
If this relay activates a gate operator with a momentary contact closure, set the relay activation time for
a short period (for example, 2 seconds). A longer activation time might cause the gate to repeatedly
open and close until the activation period has expired.
Page 13 of 33
PART 7
UNLOCK SCHEDULES
The Crown Jewel unit can automatically open any gate and close it later. This unit function is known
as the Unlock Schedules feature. Each day of the week can have up to 2 time segments. On
programmed holidays, the schedule can automatically be ignored or changed to the alternate Holiday
schedule.
NOTE: Be sure to set the Crown Jewel’s date and time before using the Unlock Schedule feature.
A. SETTING AN UNLOCK SCHEDULE FOR THE MAIN GATE (STEP 41)
You can program the Crown Jewel to automatically unlock and relock the main gate.
Format
41 + day of the week + segment + opening time + closing time + holiday option + “#”
•
The day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The segment is one digit long, either 1 or 2.
•
The opening and closing times are four digits long, in 24-hour format.
•
The holiday option is one digit long:
0 = No schedule on holidays
1 = Use same schedule on holidays
2 = Use schedule number 8 when this day falls on a programmed holiday
Example
41 + 2 + 1 + 0800 + 1700 + 1 + #
(sets segment 1 for the main gate to open at 8 AM and close at 5 PM on Mondays and
Holidays).
NOTES
1. To unlock the gate early on a scheduled day, use step 93 (Latch main gate).
2. To close a gate early on a scheduled day, use step 95 (Release main gate).
3. To extend the unlock period beyond the scheduled closing, use step 98 (Latch main
gate until).
Page 14 of 33
Doc. 6001141
Rev B
B. ERASING AN UNLOCK SCHEDULE FOR THE MAIN GATE (STEP 41)
Format
41 + day of the week + segment + 99 + “#”
•
The day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The segment is one digit long, either 1 or 2.
Example
41 + 2 + 1 + 99 + #
(Erase the Monday Segment 1 Unlock Schedule for the Main Gate).
C. SETTING AN UNLOCK SCHEDULE FOR THE AUXILIARY RELAY (STEP 42)
You can program the Crown Jewel to automatically unlock and relock the auxiliary relay.
Format
42 + day of the week + segment + opening time + closing time + holiday option + “#”
•
The day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The segment is one digit long, either 1 or 2.
•
The opening and closing times are four digits long, in 24-hour format.
•
The holiday option is one digit long:
0 = No schedule on holidays
1 = Use same schedule on holidays
2 = Use schedule number 8 when this day falls on a programmed holiday
Example
42 + 5 + 2 + 1130 + 2000 + 0 + #
(sets segment 2 for the auxiliary relay to open at 11:30 AM and close at 8:00 PM on
Thursdays, except when Holidays fall on Thursdays).
NOTES
1. To unlock the gate early on a scheduled day, use step 94 (Latch main gate).
2. To close a gate early on a scheduled day, use step 96 (Release main gate).
3. To extend the unlock period beyond the scheduled closing, use step 99 (Latch main
gate until).
Page 15 of 33
D. ERASING AN UNLOCK SCHEDULE FOR THE AUXILIARY RELAY (STEP 42)
Format
42 + day of the week + segment + 99 + “#”
•
The day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The segment is one digit long, either 1 or 2.
Example
42 + 2 + 1 + 99 + #
(Erase the Monday Segment 1 Unlock Schedule for the Auxiliary Gate).
E. ENABLING/DISABLING UNLOCK SCHEDULES (STEP 40)
You can temporarily disable or re-enable the Unlock Schedules.
Factory Setting: Ignore Unlock Schedules.
Format
40 + Unlock Schedule mode + “#”
•
The Unlock Schedule mode is one digit long:
0 = Ignore Unlock Schedules
1 = Re-enable Unlock Schedules
Example
40 + 0 + #
(Crown Jewel ignores Unlock Schedules).
Page 16 of 33
Doc. 6001141
Rev B
PART 8
CALL FORWARDING
The Call Forwarding feature redirects visitor calls to an outside telephone number instead of ringing the
house. The forwarding number is a regular phone number of up to 11 digits in length. You may also
attach one of the following features to a forwarding number:
•
an extension of an automated switchboard, or
•
an extension (up to 6 digits) that the visitor can dial from the unit’s keypad.
A. SETTING THE CALL FORWARDING NUMBER (STEP 14)
Program the telephone number to which the Crown Jewel should forward calls. NOTE: to program an
extension, see Section D.
Format
14 + telephone number + “#”
•
The telephone number can be up to 11 digits long.
Example 14 + 5551212 + #
(sets the Call Forwarding number to 555-1212).
NOTE
During a Call Forwarding call, the visitor will hear normal telephone line sounds but will not
hear the number being dialed.
B. ENABLING/DISABLING CALL FORWARDING (STEP 13)
You can program the Crown Jewel to forward calls; to stop forwarding calls; or to forward calls
according to the Scheduled Call Forwarding feature (see Section G).
NOTE: To use Call Forwarding or Scheduled Call Forwarding, you must program a call forwarding
telephone number (see Section B).
Factory Setting: 0 (disabled).
Format
13 + Call Forwarding mode + “#”
•
The Call Forwarding mode is one digit long:
0 = Disable Call Forwarding
1 = Enable Call Forwarding
2 = Enable Scheduled Call Forwarding
Example 13 + 1 + #
(enables the Call Forwarding feature)
C. DELETING THE CALL FORWARDING NUMBER (STEP 14)
Delete the Call Forwarding telephone number.
Format
14 + 00 + “#”
Example 14 + 00 + #
(deletes the Call Forwarding telephone number).
Page 17 of 33
D. SETTING THE CALL FORWARDING EXTENSION NUMBER (STEP 16 )
Enter the extension to use in Call Forwarding.
Format
16 + extension number (up to 6 digits) + “#”
•
The extension number may be up to 6 digits long.
Example 16 + 1234 + #
(sets the extension number as 1234)
NOTE
In order for the unit to dial an extension number, the Call Forwarding feature and the
Forward Call Extension Delay feature must be activated (see Section A and Section E).
E. SETTING THE CALL FORWARDING EXTENSION DELAY (STEP 15)
Program a pause between the Call Forwarding telephone number and the Call Forwarding extension.
Factory Setting: 0 (extension dialing disabled).
Format
15 + number of seconds + “#”
•
The number of seconds may be up to two digits long, from 1 to 99 seconds.
Example
15 + 22 + #
(enters a pause of 22 seconds between the Call Forwarding number and the Forward
Call extension number)
F. DISABLE THE CALL FORWARDING EXTENSION DELAY (STEP 15)
Format
15 + number of seconds + “#”
•
Enter 0 seconds to disable Call Forwarding Extension Delay
Example
15 + 0 + #
(Disables Call Forwarding Extension Delay)
NOTE:
In order for the unit dial an extension number, the Call Forwarding and Call Forwarding
Extension Delay features must be activated (see Section A and Section E above).
G. MAXIMUM NUMBER OF VOICE MAIL DIGITS VISITOR MAY DIAL (STEP 17)
Program the maximum number of digits a visitor may enter on the unit’s keypad after the visitor call
has been answered.
Factory Setting: 0 (disabled).
Format
17 + number of digits + “#”
•
The number of digits must be one digit long; it can be between 0 and 6
•
If the number of digits is 0, the visitor will not be able to enter any digits.
Example 17 + 6 + #
(sets the maximum number of digits in the extension number to 6 digits).
Page 18 of 33
Doc. 6001141
Rev B
H. CALL FORWARDING SCHEDULE (STEP 18)
Program a calls to be forwarded during specific times on specific days.
Format
18 + day of the week + starting time + ending time + holiday option + “#”.
•
The day of the week is one digit long:
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Holidays
•
The starting and ending times must be four digits long, in 24-hour format
•
The holiday option is one digit long:
0 = No schedule on holidays
1 = Use same schedule on holidays
2 = Use schedule number 8 when this day falls on a programmed holiday
Example 18 + 2 + 0900 + 1800 + 0 + #
(sets the Call Forwarding schedule for Mondays to forward all visitor calls between the
hours of 9:00 AM and 6:00 PM).
Page 19 of 33
PART 9
SECURITY FEATURES
A. CHANGING THE UNIT PASSWORD (STEP 01)
Factory Setting: 000000
Format
01 + password + “#”
•
The password must be 6 digits long.
Example
01 + 123456 + #
(sets the password to 123456).
IMPORTANT NOTE
•
After you have changed the password, be sure you verify the new password. See Section B
(Step 02)
•
If you typed the password incorrectly or you forget the password, you can reset the Crown Jewel to
the factory defaults using programming step 31. See Part 11, Section B.
B. VERIFYING THE UNIT PASSWORD (STEP 02)
Use this programming step to verify the new password you entered in step 01 (see Section A above).
Format
02 + password + “#”
•
The password must be 6 digits long.
•
If the unit responds with two beeps, the number that you entered matches the password
you programmed in step 01.
Example
02 + 123456 + #
(verifies that 123456 is the password).
IMPORTANT NOTE
•
If the unit responds with an error tone, do not exit programming. The number that you entered
does not match the password. Repeat steps 01 and 02 until you are certain that the password is
what you want.
•
If you typed the password incorrectly or you forget the password, you can reset the Crown Jewel to
the factory defaults using programming step 31. See Part 11, Section B.
C. ENABLING/DISABLING ALARM CALL (STEP 21)
Programs the unit to make an alarm call when alarm conditions occur.
Factory Setting: Disabled
Format
21 + alarm call mode + “#”
•
The alarm call mode is one digit long:
0 = Disables the alarm call feature
1 = The unit will generate an alarm call upon a door breach
2 = The unit will generate an alarm call upon a keypad “strike out”.
3 = The unit will generate an alarm call upon a door breach or a keypad “strike out”.
Example
21 + 3 + #
(sets the unit to generate an alarm call upon a door breach or a keypad “strike out”).
NOTES
1. If the alarm call feature is enabled, the destination of the call is determined by the
telephone number programmed in step 22 (see Section D below).
2. A door breach assumes that the status input is being used to monitor the closed position
of the main gate.
Page 20 of 33
Doc. 6001141
Rev B
D. ALARM CALL NUMBER (STEP 22)
Program the telephone number to call in case of an alarm condition. When you pick up the phone, you
will hear contiuous hi-low tones, indicating an alarm condition.
Format
22 + alarm call telephone number + “#”
•
The alarm call telephone number may be up to 11 digits long
Example 22 + 5551212 + #
(sets the alarm call number to 555-1212).
NOTE
The factory setting for the Alarm Call feature is disabled. To enable the alarm call feature,
see step 21, Section C above.
E. DELETE ALARM CALL NUMBER (STEP 22)
Delete the telephone number to call in case of an alarm condition.
Format
22 + 00 + “#”
•
Enter “00” for the alarm call telephone number to have the Crown Jewel call the residence
telephone.
Example 22 + 00 + #
(sets the alarm call number to the residence telephone number).
F. MAXIMUM NUMBER OF KEYPAD ERRORS (STEP 20)
You can program the maximum number of invalid entry codes that can be entered before the unit stops
accepting codes from the keypad for 3 minutes.
Factory Setting: 5
Format
20 + number of keypad errors for keypad 1 + number of keypad errors for keypad 2 + “#”
•
The number of keypad errors for keypads 1 and 2 is one digit long, from 0 to 9.
0 = No limit to the number of keypad errors
•
If you do not have a second keypad, press “#” after the number of keypad error for
keypad 1.
Examples
20 + 3 + #
(sets keypad 1 to stop accepting codes after 3 unsuccessful attempts)
20 + 4 + 3 + #
(sets keypad 1 to block after 4 unsuccessful attempts and keypad 2 to stop accepting
codes after 3 unsuccessful attempts)
NOTE
This feature can optionally trigger an alarm condition. Please refer to Section C Step 21 for
more information regarding alarm conditions.
G. ENABLING DIRECT COMMANDS (STEP 35)
You can program the Crown Jewel to accept commands directly from the residence telephones. You
can send commands to open or close gates, etc.
Factory Setting: 1 (Enables the Crown Jewel to accept direct commands)
Format
35 + direct command digit (1 digit) + “#”
•
The direction command mode is one digit long:
0 = Disable Direct Commands feature
1 = Enables Direct Commands feature from residence telephone only
2 = Enables Direct Commands feature from a remote telephone only
3 = Enables Direct Commands feature from residence or remote telephone
Example
35 + 1 + #
(enables the use of direct commands from the residence telephone only)
NOTE
For information regarding how to use the Direct Commands feature, see Part 13.
Page 21 of 33
PART 10
IMMEDIATE CONTROL FUNCTIONS
You can use the following programming steps to program or perform certain functions from a remote
telephone.
A. DO NOT DISTURB UNTIL FEATURE (STEP 89)
You can program the Crown Jewel to block visitor calls, beginning immediately, until the time you
program. Step 89 temporarily overrides the Do Not Disturb Schedule.
Format
89 + ending time + “#”
•
The ending time must be 4 digits long, in 24-hour format.
Example
89 + 0715 + #
(Block visitor calls until 7:15 AM.)
B. CANCEL THE DO NOT DISTURB UNTIL FEATURE (STEP 89)
Format
89 + ending time + “#”
•
Enter “99” for the ending time to cancel the Do Not Disturb Unit feature.
Example
89 + 99 + #
(Cancel the Do Not Disturb Until feature)
C. SPEAK THROUGH THE CROWN JEWEL MICROPHONE (STEP 90)
You can initiate communications from a telephone through the Crown Jewel’s speaker and microphone
at any time to greet visitors, ward off vandals, etc.
Format
90 + “#”
NOTE
1. This call will terminate automatically in 60 seconds unless you hang up the line sooner.
2. Extend the talk time by pressing “1” on your telephone.
D. CYCLE MAIN GATE (STEP 91)
You can activate the main relay to momentarily open the door or gate without having a visitor initiate a
call.
Format
91 + “#”
NOTE
This step have no effect if the corresponding relay is already latched open or time latched.
E. CYCLE AUXILIARY RELAY (STEP 92)
You can activate the auxiliary relay.
Format
92 + “#”
NOTE
This step have no effect if the corresponding relay is already latched open or time latched.
Page 22 of 33
Doc. 6001141
Rev B
F. INITIATING SUSTAINED ACTIVATION OF MAIN RELAY (STEP 93)
You can activate the main relay for as long as you want. Use this step if you wanted to keep the
door/gate open for an undetermined period of time.
Format
93 + “#”
NOTES
1. This step will temporarily override any existing unlock schedules.
2. You may also use this step to unlock a gate prior to an unlock schedule. The gate will
remain open until and through the unlock schedule for that day. When the unlock
schedule ends, the gate will close as it would normally on that day.
G. INITIATING SUSTAINED ACTIVATION OF AUXILIARY RELAY (STEP 94)
You can activate the auxiliary relay for as long as you want. Use this step if you want to keep the
door/gate open for an undetermined period of time.
Format
94 + “#”
NOTES
1. This step will temporarily override any existing unlock schedules.
2. You may also use this step to unlock a gate prior to an unlock schedule. The gate will
remain open up until and through the unlock schedule for that day. When the unlock
schedule ends, the gate will close as it would normally on that day.
H. RELEASE MAIN GATE RELAY (STEP 95)
You can activate the main relay until released by another program step, a direct command, or an entry
code with an unlatch relay code.
Format
95 + “#”
NOTE
This step will temporarily override any existing unlock schedules.
I. RELEASE AUXILIARY RELAY (STEP 96)
You can activate the auxiliary relay until released by another program step, a direct command, or an
entry code with an unlatch relay code.
Format
96 + “#”
NOTE
This step will temporarily override any existing unlock schedules.
J. RELEASE BOTH RELAYS (STEP 97)
You can activate the auxiliary relay until released by another program step, a direct command, or an
entry code with an unlatch relay code.
Format
97 + “#”
NOTE
This step will temporarily override any existing unlock schedules.
Page 23 of 33
K. LATCH MAIN RELAY UNTIL SPECIFIED TIME (STEP 98)
You can activate the main relay until the time of day that you specify in this step.
Format
98 + ending time + “#”
•
The ending time must be four digits long, in 24-hour format.
Example
98 + 1730 + #
(latches main gate open until 5:30 PM).
NOTE
This step will override any existing unlock schedules. You may use this step to temporarily
extend an unlock period beyond the scheduled closing time. Enter an ending time after the
scheduled closing time.
L. LATCH AUXILIARY RELAY UNTIL SPECIFIED TIME (STEP 99)
You can activate the auxiliary relay until the time you specify in this step.
Format
99 + ending time + “#”
•
The ending time must be four digits long, in 24-hour format.
Example
98 + 1730 + #
(latches auxiliary door open until 5:30 PM).
NOTE
This step will override any existing unlock schedules. You may use this step to temporarily
extend an unlock period beyond the scheduled closing time. Enter an ending time after the
scheduled closing time.
Page 24 of 33
Doc. 6001141
Rev B
PART 11
OTHER FUNCTIONS
A. SETTING ALTERNATE PREFIXES (STEP 36)
When you dial either “##” or “✱✱✱“ on the resident phone, the Crown Jewel assumes that you want its
attention for a Direct Command or programming and it disconnects from the telephone line to wait for
your commands. Some telephone companies offer special features that require dialing a preceding “#”
or “✱ “. If you subscribe to such services and the Crown Jewel interferes with using them, you can
program the Crown Jewel to accept different prefixes.
Factory Setting: 00 (Dial “##” for Direct Commands and “✱✱✱” to enter programmingmode).
Format
36 + alternate prefix mode + “#”
•
The alternate prefix mode must be 2 digits long:
00 = normal, the prefix for Direct Commands is “##”; the prefix for entering programming
mode is “✱✱✱“ followed by the 6-digit password.
01 = mixed, the prefix for the Direct Commands is a combination of the two keys (i.e., “#✱ “
or “✱#”); the prefix for programming is a combination of three keys (i.e., “#✱#” or “✱#✱
“).
02 = stars, the Direct Commands prefix is “✱✱“; the prefix for programming is “✱✱✱“.
03 = pounds, the Direct Commands prefix is “##”; the prefix for programming is “###”.
04 = none, the resident will not be able to program from the house or use the Direct
Commands.
1n = num, the Direct Commands prefix is “n#” ; the prefix for programming is “nn✱” where n
is a number from 1 to 9 (see example below).
Examples
36 + 01 + #
(sets the Alternate Prefix feature to mixed "#"s and "✱"s).
36 + 15 + #
(sets the Direct Command prefix to 5# and the programming prefix to 55✱ .
Page 25 of 33
B. RESTORING FACTORY SETTINGS (STEP 31)
To restore factory settings for programming steps 1, 6, 7, 8, 9, 10, 12, 13, 20, 21, 23, 24, 26, 29, 36,
and 40.
Format
31 + 101010 + “#”
•
The factory settings are listed on the chart located below.
NOTE
When you initiate this step, the doors/relays that were latched (timed or untimed) before
this step, will become unlatched. It is necessary for you to program the unit to latch
these relays again using steps 91 through 99.
STEP
PURPOSE
FACTORY SETTING
01
Changing the Programming Access Code
000000
06
Setting the Visitor Double Ring
Enabled
07
Setting the Maximum Visitor Ring Count
12
08
Setting Talk Time
90 seconds
09
Enabling/Disabling Pulse Dial 9
Disabled
10
Enabling/Disabling Call Waiting
Disabled
12
Enabling/Disabling Do Not Disturb Schedule
Disabled
13
Enabling/Disabling Call Forwarding
Disabled
20
Maximum Number of Keypad Errors
5 for Keypad 1
5 for Keypad 2
21
Enabling/Disabling Alarm Call
Disabled
23
Setting the Main Gate Activation Time
10 seconds
24
Setting Auxiliary Relay Activation Time
10 seconds
26
Setting Auxiliary Relay and Status Configuration
Control relay, exit request 2
29
Rings Before Answer
5
34
Programming Visitor Response Keys
9 5 2 1 ✱
36
Programming the Alternate Prefixes
Normal
40
Enabling/Disabling Unlock Schedules
Disabled
C. ENABLING/DISABLING THE NO-TELCO MODE (STEP 33)
The Telco mode is invoked when the unit is using a telephone line. Enable No-Telco mode when the
unit is not using a telephone line.
Factory Setting: 0 (disabled).
Format
33 + No-Telco mode (1 digit) + “#”
•
The No-Telco mode is one digit long:
0 = Enables Telco mode
1 = Enables No-Telco mode
Example
33 + 1 + #
(enables the No-Telco mode)
NOTE
If No-Telco is enabled while a telephone line connected to the unit, the Crown Jewel
ignores the telephone line. All Telco features like call forwarding and call waiting are
disabled.
Page 26 of 33
Doc. 6001141
Rev B
D. RINGS BEFORE ANSWER (STEP 29)
Program the number of rings before the Crown Jewel automatically answers your telephone. This
feature would be used for programming and relay activation from a remote telephone. This entry can
be set from 1 to 15 rings.
Factory Setting: 5
Format
29 + number of rings + “#”
•
The number of rings can be up to 2 digits long; it can be from 1 to 15.
Example
29 + 7 + #
(sets the unit to answer after 7 rings).
NOTE
If you have an answering machine attached to the same telephone line as the unit, make
sure you set the Crown Jewel ring count to a large enough number so that it does not
interfere with the operation of the answering machine. The Crown Jewel unit can be
remotely programmed even if the answering machine answers the line first.
E. OVERRIDING TELEPHONE COMPANY ANSWERING SERVICE (STEP 43)
You can override the answering service by dialing the line attached to your unit, letting the phone ring
once or twice only, then hanging up. After a few seconds, dial the same number again. The Crown
Jewel will answer the second call immediately, if it senses the incoming ring within the specified
override delay time.
Factory Setting: 20
Format
43 + delay time in seconds + “#”
•
The delay time in seconds may be no longer than 2 digits.
Example
43 + 15 + #
(sets the unit to answer a second call within 15 seconds).
F. RESETTING THE UNIT (STEP 32)
You can reset the unit without disconnecting the power.
Format
32 + “#”
NOTE
Once you press the “#” key, the unit will beep once, reset the unit, exit out of the
programming mode, and beep 4 times following the reset.
Page 27 of 33
PART 12
MULTIPLE UNIT INSTALLATIONS
♦ You can install up to seven Crown Jewel units on a single telephone line.
♦ Each unit must have a unique number, from 1 to 7. The installing dealer will program the unit
numbers.
♦ If you take a visitor call from one unit, you cannot send commands to a different unit during the call.
You must hang up, call the unit, and send commands
♦ Visitor calls can only be taken one at a time. For example, if you take a visitor call from the main
gate (unit 1), and another visitor tries to call from the rear gate (unit 2), you will not be notified until
you hang up the original call. However, if you are making a regular phone call, the call waiting
feature will operate normally.
A. PROGRAMMING MULTIPLE UNITS
When you program instructions from the residence telephone or a remote telephone, you must include
the unit ID code when you enter programming mode. NOTE: Programming from the keypad at the
unit does not require the entry of the unit ID code.
From the Residence Telephone
1. When you hear the dial tone, press the asterisk key three times (“✱✱✱”).
2. Enter the unit ID code.
3. Enter the six digit password. The unit will emit a high-pitched tone.
4. Press the pound key (“#”). The tone will stop.
5. The Crown Jewel is now ready to accept programming isntructions.
From a Remote Telephone
1. Dial the residence telephone number.
2. When the Crown Jewel picks up the call, press the asterisk key three times (“✱✱✱”).
3. Enter the unit ID code.
4. Enter the six digit pass word. The unit will emit a high-pitched tone.
5. Press the pound key (“#”). The tone will stop.
6. The Crown Jewel is now ready to accept programming instructions.
Example:
✱✱✱ + 3 + 030303
(enter programming mode for unit 3 using password “030303”)
B. SETTING THE UNIT NUMBER (STEP 38)
IMPORTANT NOTE
Do not use this programming step unless you have been instructed to do so by the installing dealer, or
Sentex Customer Support.
If you add or remove units, you will need to reprogram each unit’s ID code. You must program the unit
ID code at the unit keypad. You must program every unit in the chain. When you are done, verify the
each unit’s ID code using programming step 37 (see Section C below).
Format
38 + number of this unit + total number of units + “#”
•
The number of the unit is one digit long, from 1 to 7.
•
The total number of units is one digit long, from 2 to 7.
Example
38 + 2 + 4 + #
(sets this unit as unit 2 in a series of 4 units).
Page 28 of 33
Doc. 6001141
Rev B
C. VERIFY UNIT NUMBER (STEP 37)
Use this programming step to verify each unit’s ID code, in a multiple unit chain.
Format
37 + “#”
The unit will respond with the number of beeps corresponding to its unit number.
Example
Unit 1 will respond with one beep; unit 2 will respond with two beeps; unit 3 will respond
with 3 beeps, etc.
Page 29 of 33
PART 13
DIRECT COMMANDS FROM THE RESIDENCE PHONE
You can send commands directly to the Crown Jewel from the residence telephone.
NOTES:
1. Once you have performed a Direct Command from the residence telephone, you must
hang-up the phone before being able to perform another command.
2. If you have a multiple unit installation, you must enter the unit ID code.
3. To disable the Direct Commands feature, see Part 9, Section G above.
A. DIRECT COMMAND BASICS
When you enter Direct Commands from the residence telephone, you begin with a code that tells the
unit you will be entering Direct Commands. NOTE: Programming from the keypad at the unit does not
require the entry of the unit ID code.
1. Signal the Crown Jewel that you want to enter direct commands. From the residence telephone:
when you hear the dial tone, press the pound key twice (“##”), the unit ID code
(if applicable), then the six digit password.
2. The Crown Jewel is now ready to accept programming instructions.
Examples:
## + 123456
(enter direct command mode)
## + 3 + 030303
(enter direct command mode for unit three)
B. DO NOT DISTURB UNTIL (STEP 89)
You can activate the Do Not Disturb Until feature using a Direct Command.
Format
##89 + ending time + #
•
The ending time must be 4 digits long, in 24-hour format.
Example
##89 + 1330 + #
(sets the Do Not Disturb Until feature until 1:30 PM)
C. CANCEL DO NOT DISTURB UNTIL (STEP 89)
Use this Direct Command to cancel the Do Not Disturb Until feature.
Format
##89 + 99 + #
•
The ending time “99” cancels the Do Not Disture Until command.
D. INITIATING AUDIO COMMUNICATION THROUGH THE CROWN JEWEL (STEP 90)
Use this Direct Command to communicate through the Crown Jewel without receiving a visitor call.
Format
## + 90 + #
•
After the call is initiated, you have the following choice of actions:
1
Extends call time
9
Activates Relay 1 at drop call
5
Activates Relay 2 at drop call
✱
Ends call
Page 30 of 33
Doc. 6001141
Rev B
E. CYCLE MAIN GATE (STEP 91)
Use this Direct Command to cycle the main gate, without first receiving a visitor call.
Format
## + 91 + #
F. CYCLE AUXILIARY RELAY(STEP 92)
Use this Direct Command to cycle the auxiliary relay, without first receiving a visitor call. For example,
you could turn on a closed circuit TV or security light.
Format
## + 92 + #
G. ACTIVATE MAIN RELAY (STEP 93)
Use this Direct Command to activate the main relay (open the main gate) until you release it.
Format
## + 93 + #
NOTE:
To deactivate the main relay (close the gate), see Section I step 95 or Section K step 97
below.
H. ACTIVATE AUXILIARY RELAY (STEP 94)
Use this Direct Command to activate the auxiliary relay until you release it.
Format
## + 94 + #
NOTE:
To deactivate the auxiliary relay, see Section J step 96 or Section K step 97 below.
I. DEACTIVATING MAIN RELAY (STEP 95)
Use this Direction Command to deactivate the main relay (close the main gate).
Format
## + 95 + #
NOTE:
This step will temporarily override any existing unlock schedules.
J. DEACTIVATING AUXILIARY RELAY (STEP 96)
Use this Direction Command to deactivate the auxiliary relay.
Format
## + 96 + #
NOTE:
This step will temporarily override any existing unlock schedules.
K. DEACTIVATING BOTH RELAYS (STEP 97)
Use this Direction Command to deactivate the auxiliary relay.
Format
## + 97 + #
NOTE:
This step will temporarily override any existing unlock schedules.
Page 31 of 33
L. ACTIVATING MAIN RELAY UNTIL SPECIFIED TIME (STEP 98)
Use this Direct Command to activate the main relay (open the main gate) until a specified time.
Format
## + 98 + ending time + #
•
Ending time must be four digits long, in 24-hour format.
Example
## + 98 + 1730 + #
(Opens the main gate until 5:30 pm)
NOTE:
This step will temporarily override any existing unlock schedules.
M. ACTIVATING AUXILIARY RELAY UNTIL SPECIFIED TIME (STEP 99)
Use this Direct Command to activate the auxiliary relay until a specified time.
Format
## + 99 + ending time + #
•
Ending time must be four digits long, in 24-hour format.
Example
## + 99 + 2000 + #
(Activates the auxiliary relay until 10:00 pm)
NOTE:
This step will temporarily override any existing unlock schedules.
N. USING THE IN-HOUSE PAGING FEATURE
You can send the Crown Jewel a Direct Command that will cause all the telephones connected to the
unit’s phone line to give a distinctive ring. For example, you can use this command to page someone
else in the residence. The Crown Jewel can cause a single, double, triple or quadruple ring.
Format
## + 0 + ring digit + # then hang up the phone
•
The ring digit is 1 digit long, between 1 and 4:
1 = single ring
2 = double ring
3 = triple ring
4 = quadruple ring
Example
## + 0 + 3 + # then hang up the phone
(after you hang up, all the extensions on the Crown Jewel’s phone line will give a triple
ring.)
Page 32 of 33
Doc. 6001141
Rev B
APPENDIX A
THE PROGRAMMING MENU
STEP
PURPOSE
DIGITS
ACCEPTABLE INPUT
00
Exiting Programming Mode
01
Changing the Unit Password
6
02
Verifying the Unit Password
6
03
Creating an Entry Code
4, 5, or 6
4-digit entry code + relay code+time zone
04
Erasing an Entry Code
4
4-digit entry code
05
Erasing all Entry Codes
6
all code erasing sequence (101010)
06
Setting the Visitor Call Double Ring
1
1=single ring, 2=double ring
07
Setting the Maximum Visitor Call Ring Count
up to 2
1 through 24 rings
08
Setting talk time
up to 3
15 to 250 seconds
09
Enabling/disabling Pulse Dial 9
1
0=disable, 1=enable
10
Enabling/disabling Call Waiting
1
0=disable, 1=enable
11
Setting the Do Not Disturb Schedule
3 or 10
day of the week + starting time + ending
time + holiday option, 99=erases
12
Enabling/disabling Do Not Disturb Schedule
1
0=disable, 1=enable
13
Enabling/disabling Call Forwarding
1
0=disable, 1=enable, 2=schedule
14
Setting the Call Forwarding Number
up to 11
0 through 9, 00=disables the number
15
Setting the Call Forwarding Extension Delay
up to 2
0 through 30 seconds
16
Setting the Call Forwarding Extension Number
up to 6
00=disables the number
17
Setting the Maximum Number of Digits in the
Call Forwarding Extension Number
1
0 through 6
18
Setting the Call Forwarding Schedule
3 or 10
day of the week + starting time +
ending time + holiday option, 99=erases
19
Setting the Visitor Call to Guest Houses, etc...
up to 12
code number + telephone number,
00=erases a code
20
Setting the Maximum Number of Keypad
Errors
2
keypad 1 errors + keypad 2 errors
21
Enabling/Disabling Alarm Call
1
0=disable, 1=gate breach only,
2=keypad strikeout, 3=both
22
Setting the Alarm Call Number
up to 11
00=disables the number
23
Setting Main Gate time
up to 3
1 through 250 seconds
24
Setting Auxiliary Relay Time
up to 3
1 through 250 seconds
25
Entering a Time Zone Segment
4 or 11-
18
time zone number + segment number +
starting time + ending time + days of the
week, 99=erases time zone
26
Setting Auxiliary Relay and Status
Configuration
1
0=Control (with exit request),
1=Shunt,
2=Alarm,
3=CCTV (manual),
4=CCTV (instant),
5=Control (with position sense)
Page 33 of 33
STEP
PURPOSE
DIGITS
ACCEPTABLE INPUT
27
Setting the Date and Time
11
year + month + day + day of the week +
hour + minute
28
Setting Holidays
5
holiday number + month + day
29
Setting the Rings Before Answer
up to 2
1 through 15 rings
30
Adjusting the Sidetone Balance
generate 45 second tone
31
Restoring Factory Defaults
32
Resetting the Unit
33
Enabling/disabling the No-Telco Mode
1
0=disable, 1=enable
34
Changing the Visitor Call Response Keys
4 or 5
1 through 9
35
Enabling Direct Commands
1
0=disable, 1=local, 2=remote, 3=both
36
Setting Alternative Prefixes
2
00=normal,01=mixed,02=stars,
03=pounds,04=none,1n=num (n# or nn∗)
where n=1-9.
37
Beep Unit Number
38
Setting the Unit Number
2
this unit number + total number of units
40
Enabling/disabling Unlock Schedules
1
0=disable, 1=enable
41
Setting the Main Gate Unlock Schedule
up to 11
day of the week + segment number +
starting time + ending time +
holiday option, 99=erases
42
Setting the Auxiliary Relay Unlock Schedule
up to 11
day of the week + segment number +
starting time + ending time +
holiday option, 99=erases
43
Overriding Telephone Company Answering
Service
2
43 + delay time in seconds + #
89
Activating the Do Not Disturb Until Feature
4
ending time
90
Initiating Audio Communication through the
Crown Jewel
91
Cycling the Main Gate
92
Cycling the Auxiliary Relay
93
Latching the Main Gate
94
Latching the Auxiliary Relay
95
Releasing the Main Gate
96
Releasing the Auxiliary Relay
97
Releasing Both Relays
98
Latching the Main Gate Until XXXX
4
ending time
99
Latching the Auxiliary Relay Until XXXX
4
ending time