Valor GV60 SYMAX Operating Instructions Manual

Text of the manual

Remote Control Initial Pairing

The receiver and the handset of the remote control system must be initially paired before the fi rst use. (Note that batteries must already be installed in the wall mounted battery holder) 1. Insert two 1.5 V AAA alkaline batteries in the handset. 2. Locate the Reset button on the front side of the re- ceiver. 3. With a thin object, press and hold the receiver’s RESET button until you hear one short and one long beeps. After the second beep, release the reset button. 4. Within the subsequent 20 seconds, press and hold the button on the remote handset. will be dis- played on the handset during the pairing sequence. You will hear two short beeps confi rming the pairing is done. If you hear one long beep, the pairing sequence has failed or the wiring is incorrect. This is a one time pairing only and is not required when changing the batteries of the handset or battery holder. The remote control system is now ready to use. Valor 10 Electronic Ignition Remote Control System For use with Valor heaters model 1500, 1600, 1700, 1800, 2100 and 2200K OPERATING INSTRUCTIONS GV60 SYMAX ©2019, Miles Industries Ltd. Radio Frequency 918.0 MHz for USA and Canada. This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Reset button RESET

Remote Control Operation

NOTE: Before using the remote control system for the first time, the receiver and the handset must be paired. See the section Remote Control Initial Pairing on the fi rst page of this manual. Main Display To Turn Off Fire Press to turn OFF. Note: There is a 2 minute delay after switching off before the next ignition is possible. Flame Height Adjustment To increase fl ame height, press and hold . To decrease fl ame height, press and hold . You may hold the button down until the fi re is set to pilot fl ame only. CAUTION: Always check the fi re and pilot visu- ally to ensure they are off . AM ON OFF PM AM Mode Thermostatic Mode Signal Indicator Child Proof Light Fan (if included) Program Mode Temperature Time Auxiliary Feature (not used) Countdown Timer Battery Status Eco °F or °C To Turn On Fire One-Button lighting (default): Two-Button lighting: + simultaneously Press and hold for 4 seconds, until 8 short beeps and a blinking series of lines confi rms the start sequence has begun. Release button. Main gas fl ows once pilot ignition is confi rmed. Handset automatically goes into manual mode after main burner ignition. Standby Mode (Pilot Flame) Press and hold to set appliance to pilot fl ame. NOTE: When pilot ignition is confi rmed, motor automatically turns to maximum fl ame height. CAUTION: If the pilot does not stay lit after several tries call your local service technician or gas supplier.

Designated Low Fire and High Fire

To go to low fi re, double-click . “LO” is displayed. Note: Flame goes to high fi re fi rst before going to low fi re. To go to high fi re, double-click . “HI” is displayed. Choosing 1-Button or 2-Button Ignition On the remote control handset, you can choose a 1-button or 2-button ignition. You can also choose to activate or deactivate some of the functions. By default, the handset is set to a 1-button ignition. To change from 1-button to 2-button ignition, remove the batteries, wait 10 seconds, reinsert batteries, and immediately when the display fl ashes, press and hold the button for 10 seconds. ON is displayed and 1 is fl ashing. When change is complete, 1 changes to 2. To change from 2-button to 1-button ignition, proceed the same as above. ON is displayed and 2 is fl ashing. When change is complete, 2 changes to 1. Deactivating or Activating Functions These functions are active by default, but can be deactivated at any time: • Child Proof • Program Mode • Thermostatic Mode • Eco Mode • Circulating Fan Operation • Countdown Timer AM AM To deactivate functions: 1. Install batteries. All icons are displayed and fl ashing. 2. While the icons are fl ashing, press the relevant func- tion button and hold for 10 seconds. 3. The function icon will fl ash until deactivation is com- plete. Deactivation is complete when the function icon and two horizontal bars ( ) are displayed. Note: If a deactivated button is pressed, there is no function, and the two horizontal bars are displayed. To activate functions: 1. Install batteries. All icons are displayed and fl ashing. 2. While the icons are fl ashing, press the relevant func- tion button and hold for 10 seconds. 3. The function icon will continue to fl ash until activa- tion is complete, and then turn solid. Activation is complete when the function icon is displayed. Setting Celsius or Fahrenheit To change between °C and °F, press and hold + simultaneously. Note : °C = 24-hour clock °F = 12-hour clock Setting the Time 1. Press + simultaneously. Day fl ashes. 2. Press + to select a number to correspond with the day of the week. • 1 = Monday • 2 = Tuesday • 3 = Wednesday • 4 = Thursday • 5 = Friday • 6 = Saturday • 7= Sunday 3. Press + simultaneously. Hour fl ashes. 4. To select hour press or . 5. Press + simultaneously. Minutes fl ash. 6. To select minutes press or . 7. To confi rm, press + simultaneously or wait. PM PM AM

Your handset can be set to lock out all commands to the

fi replace, except OFF. To turn Child Proof ON: 1. Press and hold + simultaneously. 2. is displayed. Child Proof is now active. To turn Child Proof OFF: 1. Press and hold + simultaneously. 2. disappears. Child Proof is now inactive, and the handset has full function. Countdown Timer You can set your fi replace to automatically turn off at the end of a timer. To set a Countdown Timer: 1. Press and hold until is displayed. Hour fl ashes. 2. Press or to select Hour. 3. To confi rm, press . Minutes fl ash. 4. Press or to select Minutes. 5. To confi rm, press or wait. To turn off a Countdown Timer: 1. Press , and the countdown disappears. Note: The Countdown Timer only works in Manual, Thermostatic, and Eco modes. Maximum countdown time is 9 hours and 50 minutes. Light/Dimmer Operation On: Press , is displayed. Light is on at preset level. Off: Press , disappears. Light turns off . Setting: 1. Press and hold until fl ashes. 2. To adjust light between 20-100% press or . 3. To confi rm setting either press or wait. is displayed. Note: The light works independently of the pilot fl ame. If you want the light on but no fl ame, press button. Circulating Fan Operation Setting: 1. Press and hold until fl ashes. 2. Press to increase or to de- crease fan speed. 3. To confi rm setting, either press or wait. is displayed. Off: Press until all 4 speed level bars disappear. Note: When setting, if the fan was not switched off after last use, it starts automatically 4 minutes after ignition at maximum speed, and goes to the last set level after 10 seconds. The fan stops 10 minutes after the gas is OFF or at pilot. AM

Modes of Operation

Thermostatic Mode The room temperature is measured and compared to the set temperature. The fl ame height is automatically adjusted to achieve the set temperature. Program Mode The temperature is controlled by Programs 1 and 2, each of which can be set to go on and off at specifi c times, at a set temperature. Eco Mode Flame height modulates between high and low. If the room temperature is lower than the set temperature, the fl ame height stays on high for a longer period of time. If the room temperature is higher than the set temperature, the fl ame height stays on low for a longer period of time. One cycle lasts approximately 20 minutes. If any of the above modes (Thermostatic, Pro- gram, or Eco) are engaged by the MyFire app over WiFi, the handset will display APP. Manual Mode The on/off status of the fi replace, as well as fl ame height, are manually controlled by the user. PM ON OFF PM PM Thermostatic Mode On: Press . is displayed. Preset temperature displays briefl y, followed by the room temperature. Setting Desired Temperature: 1. Press and hold until is dis- played and set temperature fl ashes. 2. To adjust set temperature, press or . 3. To confi rm, press or wait. Off: 1. Press . 2. Press or to go to Manual Mode. 3. Press to go to Program Mode. 4. Press to go to Eco Mode. Program Mode On: Press . , 1 or 2, ON or OFF are displayed. Off: 1. Press , , or to go to Manual Mode. 2. Press to go to Thermostatic Mode. 3. Press to go to Eco Mode. Note: The set temperature for Thermostatic Mode is the temperature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode. Default Settings: • ON TIME (Thermostatic) TEMPERATURE: 70°F / 21°C • OFF TIME TEMPERATURE: “ ” (pilot fl ame only) PM ON OFF PM

1. Press and hold

until fl ashes. ON and set temperature (set in Ther- mostatic Mode) is displayed. 2. To continue, press or wait. , OFF displayed, temperature fl ashes. 3. Select off temperature by pressing or . 4. To confi rm, press . Note: The on (Thermostatic) and off set temperatures are the same for each day. Day Setting: 1. ALL fl ashes. Press or to choose between: • ALL = same settings ON-OFF every day • SA:SU = same settings ON- OFF Saturday and Sunday • 1, 2, 3, 4, 5, 6, 7 = daily timer—unique ON-OFF settings for a single day of the week, for multiple days of the week or for every day of the week. 2. To confi rm, press . ALL Selected On Time Setting (PROGRAM 1) 1. , 1, ON are displayed. ALL is displayed briefl y. Hour fl ashes. 2. To select hour, press or . 3. To confi rm, press . , 1, ON are displayed. ALL displayed briefl y. Minutes fl ash. 4. To select minutes, press or . 5. To confi rm, press . ON ON Off Time Setting (PROGRAM 1) 1. , 1, OFF are displayed. ALL is displayed briefl y. Hour fl ashes. 2. To select hour, press or . 3. To confi rm, press . , 1, OFF are displayed. ALL displayed briefl y. Minutes fl ash. 4. To select minutes, press or . 5. To confi rm, press . Note: Either continue to PROGRAM 2 and set ON and OFF times or stop programming at this point, and PROGRAM 2 remains deactivated. Note: PROGRAM 1 and 2 use the same ON (Thermostatic) and OFF temperatures. Once a new ON (Thermostatic) and/or OFF temperature has been set, that temperature becomes the new default setting. Note: ON and OFF times programmed for PROGRAM 1 and PROGRAM 2 become the new default times. The batteries must be removed to clear the PROGRAM 1 and PROGRAM 2 ON and OFF times and temperatures. SA:SU or Daily Timer (1-7) Selected • Set on time and off time using the same procedure as “ALL Selected” above. • Waiting to fi nish setting. Eco Mode On: Press button to enter Eco Mode. is displayed. Flame height modulates between high and low every 20 minutes. Off: Press button to exit Eco Mode. disappears. OFF PM

Low Battery Indication

Handset The battery icon will show when the battery needs to be replaced. Replace with two 1.5 V AAA alkaline batteries. Receiver Frequent beeps for 3 seconds when the motor turns indicate the batteries in the battery holder need to be replaced. Replace with four 1.5 V AA alkaline batteries. Automatic Shut Off Countdown Timer At the end of countdown time period, the fi re turns off . The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. CAUTION: Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset. This could cause a short circuit. Low Battery Receiver With low battery power in the battery holder, the system shuts off the fi re completely. (This will not happen if the power is completely interrupted.) Seven Day Shut Off The system shuts off the fi re completely if there is no change in fl ame height for 7 days. Automatic Turn Down 3 Hour No Communication Function The valve will turn to pilot fl ame if there is no communication between the handset and receiver for a 3-hour period. The fi re will continue to function normally when communication is restored.

190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1

Tel. 604-984-3496 Fax 604-984-0246 www.valorfireplaces.com Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Error Codes In the event of an error condition with the handset or fi replace, the handset will display an error code. Failure Code Message on Handset Duration of Display Symptom Possible Cause F04 F04 4 sec • No pilot fl ame within 30 sec • Note: after 3 failed ignition sequences, F06 shown • No gas supply • Air in pilot supply line • No spark • Reversed polarity in thermocouple wiring F06 F06 4 sec • 3 failed ignition sequences in 5 minutes • Fire is not responding, no pilot fl ame • No gas supply • Air in pilot supply line • No spark • Reversed polarity in thermocouple wiring • Incorrect pilot orifi ce if valve has been converted from LPG to NG or vice versa F07 Low battery symbol Permanent • Battery icon fl ashes on handset display • Low battery in handset F09 F09 4 sec • Fire is not responding • No electronic control of fi re • Down arrow button was not pressed during pairing • Receiver and handset are not synced F46 F46 4 sec • Fire is not responding • Intermittent response • No electronic control of fi re • No or bad connection between receiver and handset • No power at receiver (batteries low) • Low communication range (mains adapter faulty, handset not communicating with receiver)