Titon SF Xtra Vent Series Operating Instructions

Text of the manual

SF Xtra Vent

Fixing and Operating Instructions 1. Prepare slots accurately and pre-drill fixing holes. Avoid glazing rebates and reinforcement. 2. Fix vent by opening end caps and screwing to section. DO NOT OVERTIGHTEN SCREWS! End caps should be delivered closed but not clicked shut. If they click shut during transit they can be opened again by gently rotating a flat blade screwdriver as shown below. Recommended screws: 3.5mm (No.6) Round Head or equivalent. Fitting Tolerance: Due to the SF Xtra vent being designed for narrow profiles, the accuracy of fitting is vital to achieve best performance. The screws must be fitted on the same centre line as the slot, with maximum tolerances of 0.5mm above and 1mm below the centre line. BM492 Iss03 ** For optimum performance the ventilator should be installed on a flat surface free from defects ** Fixing Instructions Operating Instructions Open Ventilator at either end by levering open under end cap. Close Ventilator by pressing vent at both ends until both ‘click’. The SF Xtra ventilator allows the user to select the following projections for complete control: Closed Deceit Closure Half Open Fully Open *click* 10 16 10 2.75 7.5 2.75 8 13 *click* 0.5 MAX 0 1 MAX

Slot Size (mm)

SFX 13 2500EA Vent 294mm 2500EA 294 260 SF318 Canopy 318 300 XC13 267 Canopy SFX 13 2500EA vent 253mm 2500EA 253 219 SFX 205 Plastic clip fix canopy 203 SFX 13 4000EA Vent 434mm 4000EA 434 400 SF441 Canopy 441 423 XC13 412 Canopy 411 387 SFX 13 5000EA Vent* 400mm 5000EA 400 366 SFX 13 5000EA Vent 465mm 5000EA 465 431 SFX418 Plastic Clip Fix Canopy 418 SFX 13 5000EA Vent 529mm 5000EA 529 495 SF528 Canopy 528 510 XC13 497 Canopy 497 473 SFX 16 4000EA Vent 374mm 4000EA 374 340 HF404 Canopy 404 385 XC16 364 Canopy 364 339 SFX 16 5000EA Vent 509mm 5000EA 509 475 HF 529 Canopy 529 510 SFX 13 2500EA Vent 294mm 2500EA 294 260 SF318 Canopy 318 300 SFX 13 5000EA Vent 529mm 6000 Free Area 529 495 TV4000 575 Canopy 575 560 SFX 16 Vent 419mm 5500 Free Area 419 385 TV90 425 Canopy 425 415 Slot Details SF Xtra Vent Vent & Canopy Slot Details 223 13 173.5 13 173.5 20 165 13 165 10 215 13 215 20 151 16 151 10 215 16 215 20 235 13 231 13 231 7 176 16 176 7 *This vent is designed for use where no protection from weathering required or for ventilation of a habitable room through another room or conservatory. BM492 Iss04 Failure to adhere to these instructions invalidates your Titon Product Guarantee. Paint or corrosion not covered by Guarantee. 194 13 198 13 198 10

Other Fan Manuals