PSC Scanning, Inc.

959 Terry Street Eugene, Oregon 97402-9120 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Fax: (541) 686-1702 PSC and the PSC logo are registered trademarks of PSC INC. This manual and the procedures described in it are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or part without prior written consent from PSC Scanning, Inc. The same proprietary and copyright notice must appear on any permitted copies as appears on the original. This exception does not permit copies to be made for others, whether or not sold. Under the law, copying includes translating into another language or format including electronic media. Disclaimer Reasonable measures have been taken to ensure that all information contained in this manual is complete and accurate. However, PSC Scanning, Inc. reserves the right to change any specification at any time without prior notice.

UNIVERSAL WEDGE INTERFACE PROGRAMMING

For your convenience, this guide provides minimal configuration and op- tion settings for your scanner's Universal Wedge interface. For more de- tailed programming information and features, reference the QuickScan 6000/6000 Plus Universal Wedge Programming Guide (R44-1548), avail- able from your dealer. DISCONNECTING/CONNECTING THE INTERFACE (I/F) CABLE To disconnect the I/F cable at the scanner, insert a bent paper clip or .050" hex driver into the opening marked CABLE RELEASE as shown in Figure 1, and push inward. Once the connector latch is released, con- tinue to hold in on the latch while carefully pulling the cable free. Connect the scanner to your system using ONLY the proper PSC ap- proved QuickScan 6000/6000 Plus I/F cable. WARNING Connection using an unapproved cable can result in damage to the scanner. QuickScan 6000/6000 Plus cables can be identified by a cable I.D. code printed on a white label, ap- proximately 1" in length, attached to them. Interface Connector Overmolding Latch Approved QuickScan 6000/6000+ Cable DO NOT use unapproved cables Paper Clip Cable Release Figure 1. Disconnecting/Connecting the QuickScan 6000/6000 Plus I/F Cable 1 R44-1549

RETURN TO FACTORY CONFIGURATION

If, during a programming session, you wish to reset the scanner's con- figuration to its original factory settings, scan the RETURN TO FACTORY SETTINGS label below. Use this label ONLY IF NECESSARY, since it will reset any changes made to this interface during any previous program- ming session. RETURN TO FACTORY SETTINGS NOTE PROGRAMMING MODE The scanner must be placed in Programming Mode before its configura- tion can be altered using the barcodes in this guide. Enter Programming Mode by scanning the START label found at the bottom of each page. The scanner's green light will flash continuously, indicating the scanner is in Programming Mode. While in Programming Mode, the scanner will recognize only specially formatted programming barcode labels like those contained in this guide, and will not decode barcode labels of any other type. Scan all program- ming barcode labels needed to set the scanner's features to the desired settings. The scanner will beep after each barcode label is scanned, indi- cating that the setting has been stored in memory. The scanner will emit a rejection tone if a scanned barcode programming label isn't valid. To exit Programming Mode and save all changes made during the pro- gramming session, scan the END label located at the bottom of each page. The scanner will return to normal operation. Disconnecting power during Programming Mode will cause the scanner to return to its previous settings. 2 QuickScan 6000/6000 PLus Universal Wedge Interface Programming */+$* When this feature is scanned, return to factory set- tings will take about five seconds to complete. The scanner will sound a tone at its conclusion.

PC KEYBOARD WEDGE INTERFACE SELECTION

The default communication mode (factory settings) is Keyboard Wedge for PC AT (keyboard I.D. 11). Use the codes on this page to activate keyboard-wedge mode and to select the I.D. corresponding to your computer or terminal (reference Connectivity Guide R44-1040 or call PSC Customer Support): *AEU* Consult the list of connections listed in Connectivity Guide R44-1040 (or call PSC Customer Support) and enter the I.D corresponding to your computer or terminal using this barcode pad. Use the next pages to adjust some general parameters of Universal Wedge communication. KEYBOARD-WEDGE MODE ACTIVATED 3 R44-1549 9 *AG9* 6 *AG6* 3 *AG3* 0 *AG0* 8 *AG8* 5 *AG5* 2 *AG2* 7 *AG7* 4 *AG4* 1 *AG1* *$%/* START END *$+$*

Other Scanner Manuals