Chapter 3 Setting

6F8C1400 18 3.2 Network Parameter Setting The network parameters can be set with the operation mode setting switches and station address setting switches. For methods to set these switches, refer to "Table 3-1 Station address setting" and "Table 3-2 Operation mode setting table." For the EN911 module, the following network parameters must be set. · IP address type · Station address 3.2.1 Network ID and subnet mask ■ Class C setting (DIP switch 4 (IP address type)=off) Use the operation mode setting switches to set the IP address type to "Class C." Network ID: 192.168.0. ...

Chapter 3 Setting

6F8C1400 28 3.4 Network Information 3.4.1 MIB information The EN911 include MIB information. Select the target EN911, and right-click it to select [MIB information]. Figure 3-9 MIB information select screen Remark ・ MIB: Management Information Base ...

7.1 Information by Socket

Unified Controller nv series Ethernet (EN911) Module Instruction Manual 41 7.1.2 Referring to information by socket As described in “7.1.1 Configuration of information by Ethernet socket,” information by Ethernet socket of the EN9 module can be referred to using I/O variables. There are some cautions on accessing the information. When socket communication is performed using an instruction word by the controller, the socket number is obtained from the instruction word using the USEND_N command. The socket number is managed by the controller. The socket number is ...

Appendix D Decimal-hexadecimal Conversion Table

6F8C1400 56 Table D-1 Decimal-hexadecimal conversion table (1) Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal 0 0 32 20 64 40 96 60 1 1 33 21 65 41 97 61 2 2 34 22 66 42 98 62 3 3 35 23 67 43 99 63 4 4 36 24 68 44 100 64 5 5 37 25 69 45 101 65 6 6 38 26 70 46 102 66 7 7 39 27 71 47 103 67 8 8 40 28 72 48 104 68 9 9 41 29 73 49 105 69 10 A 42 2A 74 4A 106 6A 11 B 43 2B 75 4B 107 6B 12 C 44 2C 76 4C 108 6C 13 D 45 2D 77 4D 109 6D 14 E 46 2E 78 4E 110 6E 15 F 47 2F 79 4F 111 6F 16 10 48 30 80 50 112 70 17 11 49 31 ...

Chapter 3 Setting

6F8C1400 24 Ethernet setting The link speed and duplex of Ethernet can be specified statically. The available combinations are as follows.  Auto-Negotiation (default)  10M half-duplex  100M half-duplex 4 Download the registered information to the EN911. Download can be done as batch download to the controller. 5 Restart the system. The downloaded information becomes effective from the next startup. After the download is complete, turn ON the power of the EN911, which is supplied to SA9**, from OFF. Note · Be careful so that the address does not overlap with o ...

1.1 Functions and Characteristics of the EN911 Module

Unified Controller nv series Ethernet (EN911) Module Instruction Manual 3 ■ Comparison of function with the EN811 module Item EN811 EN911 Protocol TCP/UDP/IP, PCMP(Note 1) TCP/UDP/IP Transmission speed 10M/100M/1Gbps 10M/100M No. of units installed Up to 4 units per base unit Up to 16 special modules in total per controller (as long as the number of all Ethernet module sockets per controller does not exceed 48) No. of sockets Up to 48 sockets per unit (Up to 48 sockets per controller) Up to 12 sockets per unit No. of transmission ...

Chapter 1 Introducing the EN911 module

6F8C1400 6 ■ Node address setting switch (STN-H, STN-L) Switches to set the station address in hexadecimal. For setting method, refer to "Chapter 3 Setting." ■ Operation mode setting switch (MODE) Switches to set the operation mode. For setting method, refer to "Chapter 3 Setting." ■ Serial communication port RS-232C (TOOL) A RS-232C port for maintenance. The connector is a 9-pin D-sub connector (socket). ■ Ethernet RJ-45 connectors (Ethernet) A communication port for the Ethernet. The Ethernet cable (category 5 or more) is connected to it. � ...

Toshiba NV Series user guide recommended for: RBC-EXW21E2, BMS-CT1280UL, TSL3000, TOSVERT VF-S15 series, BMS-CT1280E.

⚠️ Download Safety

The Controller Instruction manual (72 pages) is completely safe to download (last scan date: 13/04/2026).

Related PDF Instructions for Toshiba NV Series:

Controller Equipment: Frequently Requested

Have some Questions about Toshiba NV Series Device?

Get valuable and actionable advices from other Toshiba NV Series device users. Describe your problem or question, regarding the using of NV Series, in as much detail as possible, and other users will be able to answer you.