Priefert RC98SCOREAI Operating Instructions

Specifications

Brand: Priefert
Category: Farm Equipment
Model: RC98SCOREAI (Operating Instructions)
File Type: PDF
File Size: —
Pages: 3

Read Online

Read the Priefert RC98SCOREAI Operating Instructions online using the built-in PDF viewer.

Text of the manual

Congratulations on purchasing Priefert’s new “SCORE” Chute.

This is the “Ultimate Training Chute”. In the fully automatic mode, the rider can train his horse to respond to the rider’s que, NOT the sound of the chute or the action of the steer. Having a well trained horse is the key element for success, and the Score Chute helps keep your horse competition ready. Roping Chute Hook-Up Step 1: Install a standard 1/4” NPT, male, quick-connect air fitting into hole marked air supply at back of the Automatic Control Box (ACB). Be sure that the fitting is the correct size for the air line you intend to use. (See Diagram 1) Step 2: Connect air supply to fitting at the back of (ACB). Set regulator on air compressor at 90 psi. Proper performance requires a minimum of 2hp air compressor that will produce 3.1 cfm at 90 psi, with a 4 gallon tank. Step 3: Connect electrical cord to 110 volt outlet. NOTICE: Priefert Manufacturing Recommends using a dedicated Air Compressor to prevent damage from contamination to the Compressed Air System. Use Clean & Dry Compressed Air Supply. Drain Compressor & Air Tanks Daily. SEE ATTACHED NOTICE DIAGRAM 1 - Insert Fitting (Male, 1/4” NPT Quick-Connect Shown) Automatic Control Box MAIN POWER INDICATOR AUTOMATIC MODE INDICATOR GATE DELAY INDICATOR GATE DELAY SETTING AUTOMATIC MODE ON/OFF SWITCH 110 VOLT POWER CORD AIR DISCHARGE MUFFLERS COMPRESSED AIR CONNECTION (See Step 1)

2630 S. Jefferson

P.O. Box 1540 Mt. Pleasant, TX 75456-1540 1-800-527-8616 903-572-1741 903-572-2798 Fax [email protected] GATE DELAY Located on the back of the Control Box is a “GATE DELAY” setting. A silver knob activates and sets the delay timing. Each click clockwise gradually delays the activation of the opening of the Front Gate from 2 to 30 seconds. The rider can adjust the amount of time for the chute to open after pressing button “1”, and then ready for the steer release. AUTOMATIC The button on the right rear of the Control Box switches the chute into “AUTOMATIC” mode, where the chute uses an electronic eye to detect the presence or absence of a steer. In Automatic mode, pressing button “1” opens the Front Gate. A few seconds after detecting the steer left the chute, the headgate closes. The tailgate then opens, and upon detection of the next steer having entered the chute, the tailgate closes. One push of a button has completed the entire cycle & ropers have the next steer loaded and ready to go upon return to the roping box. AUTOMATIC with GATE DELAY Both of these features, used together, allows the rider to choose a Delay period from when the Front Gate opens, and the opening of the Neck Gate. Pressing button “1” opens the Front Gate, seconds later, the Neck Gate opens. The chute then cycles again as in “Automatic” mode. Pressing button “3” will then close the Neck Gate. Combining these functions will help train your horse to respond to the que from the rider, NOT the opening of the chute. The Front buttons of the Remote operate the Front Gate of the Score Chute The Rear buttons Toggle the Neck Gate and Rear Gate of the Score Chute Pressing this button will OPEN the FRONT GATE of the Score Chute Pressing this button will CLOSE the FRONT GATE of the Score Chute Pressing this button will toggle to OPEN and CLOSE the NECK GATE of the Score Chute Pressing this button will toggle to OPEN and CLOSE the REAR GATE of the Score Chute GATE DELAY “ON” & set to 4 sec. AUTOMATIC “ON” AUTOMATIC with GATE DELAY “ON” and set to 4 Seconds Delay & Automatic Settings Score Chute Operation

USE OF LUBRICANTS ON

COMPRESSED AIR SYSTEMS OF THIS CHUTE CAN CAUSE COMPONENT FAILURE!  DO NOT Lubricate Air Cylinder Rods Externally.  DO NOT Lubricate Air System Internally.  DO NOT Clean Components with Solvents. Priefert Manufacturing Recommends using a dedicated Air Compressor to prevent damage from contamination to the Compressed Air System. Use Clean & Dry Compressed Air Supply. Drain Compressor & Air Tanks Daily. Questions? Call Priefert at 800-527-8616 OPMAN-RC98SCOREAI_0518

Other Farm Equipment Manuals