6212WF/6212WFDS Electric Strike

® Figure 1 DC input is nonpolarized. NOTE ! J1 J2 P2 Switches shown with tripper depressed, strike lip closed and locked (switches and tripper on 6212WFDS only) Use crimp connectors to splice field wiring to P2 leads; insulate unused leads P1 P1 J1A P1A SO-12 or SO-24 12 VDC or 24 VDC 12 VAC SO-12 12 VDC or 24 VAC SO-24 24 VDC { { J2 Fail safe (FS) J2 Fail secure (FSE) S1 S2 1 2 3 4 5 6 S1 S2 1 2 3 4 5 6 Wiring for DC supply Wiring for AC supply 4. Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks. Fail safe (FS) lip locks. Figure 1 shows status of switches. 5. Install strike with two #12-24 screws. Make sure clearance between latch bolt and strike lip is 1/32” (Figure 2). If not, uninstall strike, adjust (Figure 3), and reinstall. 6. If latch bolt does not extend far enough to actuate tripper, install extension (Figure 4). (Tripper on 6212WFDS only.) 7. Test door: With strike unlocked, door opens with latch bolt extended. When door closes, latch bolt rides over strike lip. 931222_00(6) Copyright © 2004 Ingersoll-Rand. All rights reserved. Solenoid 89/336/EEC Standard: 5 A, 30 VDC Gold: 0.25 A, 30 VDC SWITCH RATINGS } P2 Red (C) Blue Yellow White (C) Gray Violet } S1 (monitors tripper) S2 (monitors strike lip) Use crimp connectors to splice field wiring to P1 leads Tripper Figure 4 Extension Figure 2 Top view; faceplate not shown for clarity 1/32” Latch bolt Strike lip Yellow solenoid wires = 12 VDC, 0.57 A Black solenoid wires = 24 VDC, 0.29 A (also shown on strike label) SOLENOID POWER REQUIREMENTS Figure 3 To adjust strike, loosen screws A, B, and C and move backbox sideways as necessary A B C Notes: Deadbolt will not function with this strike. Check with factory for retrofit applications. 1. For lock or device preparation, see their directions. 2. Prepare frame for strike (see other side). 3. Wire strike (Figure 1). (Switches on 6212WFDS only.) Single Door Wood Frame Mortise or Cylindrical Application 931222-00

Strike Dimensions and Required Clearances

Door Preparation for Strike 931222_00(6) Pilot drill for #12 wood screws LHR shown RHR opposite 1-7/16” minimum clearance 6” long lead wires; 1/2” dia. minimum wiring access 5/8” 1-11/16” Minimum clearance 2-3/8” minimum clearance 3-3/8” 6-3/8” 1-1/4” 1-1/8” 1/8” C strike L L C lock and strike L 5-5/8” C strike 3/4” 3-3/8” 1-1/4” 5/8” 1-15/32” 1” dia. minimum clearance 6-3/8” 3-3/16” 2-13/16” 5-5/8” 1-13/32” 3-9/16” 3-11/16” 1-15/32” 2-3/8” minimum clearance

Other Door locks Manuals