TriMark e-PAD Manual
Text of the manual
Electronic Access Security Keyless-entry
e-ASK Keyless-entry System
Installation & Instructions
CCAANN M
Muullttiipplleexx SSyysstteem
m
4
6
June 2008
Table of Contents
Introduction .............................................................................................3
Cargo e-FOB Operation and Features ..................................................3
Non-doorbell e-PAD Operation and Features ......................................4
Locking doors with keypad ...................................................................4
Secure Operations................................................................................4
e-ASK CAN DIP Switch Configuration –...............................................5
Additional Features.................................................................................5
Dome/Porch Light Activation ................................................................5
e-PAD Anti-tamper Deactivating Feature .............................................5
Trim Pot Variable Resistor...................................錯誤! 尚未定義書籤。
Keypad Learn Wire...............................................................................6
Status LED............................................................................................6
Miscellaneous I/O Module Features.....................................................6
Door locking and unlocking ..............................................................6
Timed Dome/Porch Light Activation ................錯誤! 尚未定義書籤。
Teaching Additional Transmitter Fobs .................................................7
Teaching Keypad New Authority / Access Codes ...............................9
Assign New Access Codes.................................................................10
Wiring Assignments……………………………………………………..…11
Troubleshooting....................................................................................12
This manual provides the necessary information for the proper installation
and use of TriMark’s CAN e-ASK system. The e-ASK system comes with
the following components:
•
e-FOB (keyless entry radio frequency [RF] FOB transmitter and
receiver)
•
e-PAD keypad user interface
e-FOB Operation and Features
Button
Function
Entry Lock
Locks entry door and arms security system.
Entry Unlock
Unlocks entry door and activates the porch light.
Note:
•
The FOB transmitters and receiver are shipped programmed.
After making all necessary wiring connections (see page 11 for
wiring information), the e-FOB system will function as shown.
Non-doorbell e-PAD Operation and Features
The e-PAD is shipped with default authority and access codes. Unless the
OEM or dealer has changed default codes, the authority and access
codes are as follows:
Access code:
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
1/2
3/4
5/6
7/8
9/0
Authority code:
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
7/8
7/8
7/8
7/8
7/8
Locking doors with keypad
Press and hold down the (1 / 2) or (1) button for 1-2 seconds. An access
code is not needed to lock the doors.
Secure Operations
Entering a valid 5-digit access code enables secure operations. After
entering an access code, the keypad is enabled for 5 seconds and an
additional button press initiates a secure operation, such as unlocking the
doors.
Notes:
•
The authority code does not allow for secure operations. It is
only used to assign access codes (see page 9 for information
on setting access codes).
•
If an unassigned button or no button is pressed while the
system is enabled, the keypad reverts back to disabled state.
•
The secure keypad operations are set depending on the
system configuration.
e-ASK CAN DIP Switch Configuration –
• DIP switches 1-3:
The settings of DIP switches 1-3 define CAN address of the IO RF receiver
module. The setting a unique address is required if multiple modules are
used on CAN network. If only 1 module is used on network then all DIP
switches should be set to default ON position.
•
DIP Switch 1: On
•
DIP Switch 2: On
•
DIP Switch 3: On
•
DIP switches 4-6:
The setting of DIP switches 4-6 define configuration of the IO RF receiver
module. Different configurations of provide different functionality for
keypad and interior switches. Spartan’s setting is as follows:
•
DIP Switch 4: On
•
DIP Switch 5: Off
•
DIP Switch 6: Off
• DIP switch 7:
The setting of DIP switch 7 defines the type of remote fob transmitter,
either standard fob or cargo fob. Spartan would have this DIP switch on.
•
On: Cargo fob
• DIP switch 8:
The setting of DIP switch 8 defines the type of CAN protocol, either RV-C
or SAE J1939. Spartan would have this DIP switch on.
•
On: SAE J1939
Additional Features
Dome Light Activation
The dome light is activated for a timed duration (20 seconds) whenever
the system is unlocked from keypad or FOB transmitter.
e-PAD Anti-tamper Deactivating Feature
After repeated attempts to enter incorrect codes (20 button presses
without enabling), the keypad enters an inactive mode that disables button
for 1 minute. This helps prevent undesired access by entering random