TVP-B_TVP-P Price Computing Scales Technical Manual

- 2 - CONTENTS 1. PRECAUTIONS........................................................................................................................... - 3 - 2. SPECIFICATIONS........................................................................................................................- 5 - 3. INTRODUCTION.........................................................................................................................- 8 - 4. INSTALLATION...........................................................................................................................- 9 - 5. Parts Description.....................................................................................................................- 11 - 5.1 Overall View..........................................................................................................................- 11 - 5.2 Key board..............................................................................................................................- 12 - 6. OPERATION.............................................................................................................................- 14 - 1. Power ON/OFF........................................................................................................................- 14 - 2. Zero.........................................................................................................................................- 14 - 3. Tare......................................................................................................................................... - 14 - 4. Sample weighing...................................................................................................................- 15 - 5. Unit Price Setting................................................................................................................... - 15 - 6. Unit Price Memory.................................................................................................................- 15 - 7.Back light..................................................................................................................................- 16 - 8.Automatic Unit Price Clear...................................................................................................... - 17 - 9.Change unit..............................................................................................................................- 17 - 10. Accumulation........................................................................................................................- 17 - 11.Give change........................................................................................................................... - 18 - 12.Commodities Without Weighing...........................................................................................- 18 - 7. PARAMETER............................................................................................................................- 19 - 7.1 PARAMETERSETTING............................................................................................................ - 19 - 7.2 PARAMETER MENU BLOCK...................................................................................................- 20 - 8. CALIBRATION.......................................................................................................................... - 23 - 9. RS 232 OUTPUT.......................................................................................................................- 25 - 9.1. Print Format.........................................................................................................................- 25 - 10. ERROR CODES....................................................................................................................... - 26 - 11. DRAWING..............................................................................................................................- 28 - 12. SEALING METHOD.................................................................................................................- 32 - 12.1 Sealing chart....................................................................................................................... - 32 -

TVP-B_TVP-P Price Computing Scales Technical Manual

- 3 - 1. PRECAUTIONS WARNING DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, CLEANING, OR SERVICING. FAILURE TO DO SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT. CAUTION  Permit only qualified persons to service the instrument  Before connecting or disconnecting any components, remove the power.  Failure to observe these precautions bodily harm or damage to or destruction of the equipment.  The price computing scale is a precision electronic instrument, handle it carefully.  Do not install the scale in direct sunlight.  Verify the local voltage and receptacle type are correct for

TVP-B_TVP-P Price Computing Scales Technical Manual

- 4 - the scale.  Only use original adaptor, other could cause damage to the scale.  Pluggable equipment must be installed near an easily accessible socket outlet.  Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.  Avoid sudden temperature changes, vibration, wind and water.  Avoid heavy RF noise.  Keep the scale clean

TVP-B_TVP-P Price Computing Scales Technical Manual

- 5 - 2. SPECIFICATIONS MODEL TVP-B TVP-P Display 0.59inch/15mm LCD Display with white LED back Light Gross weight 9lb(4.1kg) 9.9lb(4.5kg) Capacity 12lb(6kg) 30lb(12kg) 60lb(30kg) Readability 0.002lb(1g) 0.005lb(2g) 0.01lb(5g) Max. Divisions 6000e Weighing Units kg/lb Pan size 8x10.5inch/204x265mm Housing ABS Plastic and Stainless Steel pan Interface RS232 Output standard Operation Temperature 14°F - 104°F/-10°C -+ 40°C Stabilisation Time 1 Seconds typical Power Ac Adaptor 12V/500mA , Rechargeable Battery 6V/3.2Ah Keypad 20 keys

TVP-B_TVP-P Price Computing Scales Technical Manual

- 8 - 3. INTRODUCTION  TVP-B, TVP-P series of economic price computing scales are very compact, reliable , high accuracy and much stable.  It use LCD display with white LED back light, with the different back light operation.  10 indirect PLU ,it can store 10 unit price values  Accumulation and change function  Auto unit price clear operation  Weighing units conversion(kg/lb/oz)  Standard RS-232 can be connect to receipt and label printer

TVP-B_TVP-P Price Computing Scales Technical Manual

- 9 - 4. INSTALLATION 4.1 Unpacking Carefully take the scale out of its package, make it sure its not damaged and all accessories are included. Accessories, 1. Scale 2. Adaptor 3. Stainless steel pan 4. Product manual Keep the packaging material for your future use. 4.2 Level Adjusting Place the scale on a table. Check the water mark. If, bubble is not centre adjust the leveling feet until reach centre. Check the level when you change the location.

TVP-B_TVP-P Price Computing Scales Technical Manual

- 10 - 4.3 Connect Adaptor  To charge the battery insert the adaptor pin to jack. Adaptor simply plug into the mains power. The scale no needs to be turned on.  The battery should be charged for 12 hours for full capacity.  Left side of the display there is an LED to indicate the status of battery charging. When the scale is plugged into the mains power the internal battery will be recharged. If the LED is green, the battery has a full charge. If it is red, the battery is nearly discharged and if yellow, the battery is being charged.  Do not use any other type of power adaptor than the one supplied with the scale.  Verify that the AC power socket outlet is properly protected. Note: Please charge the battery before using the scale for the first time. Adaptor Jack Power Key

TVP-B_TVP-P Price Computing Scales Technical Manual

- 12 - 5.2 Key board Key board Keys Press this key to to Numeric Keys, enter unit price / PLU ; In setting mode ,press Clear incorrect entries and error conditions Set unit price in fix mode,press the key to input double zero;set unit price in float mode,press the key to input decimal point Returns the display to zero.In parameter settings,to escape from the menu Subtracts the tare values, change to gross to net mode and enter parameter settings. Enter to auto clear mode Used to store or recall unit price,In parameter setting mode,used to scroll down the menu Used to give change operation Add the current data aggregated.In parameter setting mode,used to scroll up the menu

TVP-B_TVP-P Price Computing Scales Technical Manual

- 13 - Used to change unit (kg/lb/oz) Quantity key, use for without weighing. Display Overlay Display Symbols BATT. BATT. Battery indicator. When it’s illuminated, battery should be recharge NET Net Weight STABLE Stable indicator. When it’s illuminated, the scale is stable ZERO Zero indicator. When it’s illuminated, the scale is in Zero point kg/lb/oz Current weighing unit SAVE Save Indicator CHARGE Battery charging indicator ACC Accumulation indicator CH Check out indicator

TVP-B_TVP-P Price Computing Scales Technical Manual

- 14 - 6. OPERATION Initial Start-Up Warm-up time of 15 minutes stabilizes the measured values after switching on. 1. Power ON/OFF Power switch is located below the right side of the scale. Switch on the scale by pressing on/off. The display is switched on and the self test is started. If you want to switch off press again the key. 2. Zero Environmental conditions can lead to the balance exactly zero in spite of the pan not taking any strain. However, you can set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero. 3. Tare The weight of any container can be tared by pressing key, so that with subsequent weighing the net weight of the object being weighed is always displayed.  Load weight on the pan.  Press key. Zero is displayed, and tare is subtracted.  Remove weight from the platform. Tared weight is displayed. It can set only one tare value. It can display with a minus value.  Press key. Zero is displayed, tare weight is cleared.

TVP-B_TVP-P Price Computing Scales Technical Manual

- 15 - 4. Sample weighing  Place goods to be weighed on the platform.  Wait few seconds for stability display.  Read the result.  Avoid overloading. When display appears “ol” reduce the load or unload. 5. Unit Price Setting Weight Unit Price Total Price  Make sure platform is empty and display is zero.  Place goods to be weighed on the platform.  Enter the unit price by pressing numeric keys. Total price will be calculate automatically. 6. Unit Price Memory It can store 10 unit price values. It can select from 0 to 9 numeric keys. Save to memory  By pressing numeric keys enter the unit price 10.  Press and hold , display will be shown 0. 000 0. 00 0. 00 1 500 0. 00 0. 00 1 500 5. 00 750 0000 10 0 save pos Ps 0-9

TVP-B_TVP-P Price Computing Scales Technical Manual

- 16 -  Press numeric key 0 to 9, to select location. If want to select to numeric key 1, press 1. Unit price 10 saved into numeric key 1. Re-Cal Unit Price When you want to weigh stored unit price weighment,  Press , display will be shown  Press the numeric key, which you stored in 0 to 9. If want to use stored in 1, press 1.  Display will be shown, which unit price is stored.  Place the load on the platform, total price will be calculate automatically. 7.Back light It has an option to choose the back light operation. When in normal weighing mode, Press and hold key until to show the display Press the key to change the settings back light display mode to Auto / On /Off. Press the key to confirm. Display Description bLSEt ModE AUto Backlight will be turned on, when start to use or when weight is not in Plu saved load pos Ps 0-9 10 0000 0 BLSEt ModE AUto

TVP-B_TVP-P Price Computing Scales Technical Manual

- 17 - zero. bLSEt ModE on Backlight will be turned always on bLSEt ModE oFF Backlight function will be turned off 8.Automatic Unit Price Clear It can set automatic unit price clear. Press key to save indicator turn on or off. When save indicator on, unit price appear after return to zero. When save indicator off, unit price will be clear automatically. 9.Change unit By pressing key to change unit kg to lb or oz during the normal weighing mode.When change the unit, unit indicator will be shown in unit price display. 10.Accumulation The scale can be set to accumulate manually by pressing key,To enable the accumulation function on,see parameters F11RS232>mode>EP50 Before enter parameters,press the calibration switch,switch is locating below the scale Before operation scale should be stable and return to zero, only when weight more than 20d  The values (price) displayed may be added to the values aggregated by pressing the key. The "Total Price" display will show the total price. These values will appear for 2 seconds.

TVP-B_TVP-P Price Computing Scales Technical Manual

- 18 -  The scale must return to zero or a negative value before another sample can be stored.  Other products may be added by pressing the key. It may take up to 99 entries or until it reaches the maximum displayable digits.  To view the total price stored, by pressing the when the scale is in zero point. The total will be displayed for 2 seconds.  To clear memory, by pressing to clear all values. 11.Give change After finish the accumulation, can use the account operation., To enable the function on, please see the parameters F12>change >on Press key ,and the CH indicator will be on.Weight display shown summation price By pressing numeric keys enter the amount, which is given customer. If enter 3000, remaining balance will be shown in Total price display. Press key to return weighing mode and clear the account memory. 12.Commodities Without Weighing Using numeric keys to input unit price ,Press key, the display will be show Using numeric keys to input quantity in the weight window,the total price will be show automatically Press key to return normal weighing mode. 2460 0 ------- - 2460 3000 540 0 5. 00 0. 00 3 5. 00 15. 00

TVP-B_TVP-P Price Computing Scales Technical Manual

- 19 - 7. PARAMETER 7.1 PARAMETERSETTING Enter into the Menu  Turn on the scale. Press and hold key during the self test. Display will show “Pn” briefly PIN is activated. Press the PIN number to get into the parameter menu.  The default PIN number is “0000”  Press numeric key 0 four times , display will be shown Pn - - - -  Press key to confirm, It will enter into the parameter settings and will to show “ menu unit kg” . Enter to Selected Menu  Press , it can confirm which will be shown displayed. Select the Menu  Press or . It can choose menu block one by one. Return to Weighing Mode  Press escape from the menu and exit to weighing mode Active Parameter If want to change the settings cal , res , cap , speed , SCSIUE tare , grA , reset before enter the parameters ,should press CAL switch to access . CAL switch is locating bottom of the scale

TVP-B_TVP-P Price Computing Scales Technical Manual

- 20 - 7.2 PARAMETER MENU BLOCK Menu Sub-Menu DESCRIPTION F0 CAL Calibration F1 rES 3000 Set external resolution 6000 Dual-i Dual-r F2 CAP 6KG/12lb Set Scale Capacity 12KG/30lb 30kg/60lb F3 PdECi 0 Set Price Decimal Point 0. 0 0. 00 0. 000 0. 0000 F4 PdESC FIX Set unit Price to FIX or FLOATING FLOAT F5 SPEED Slow To select A/D speed Medium Fast F6 Min coin Set the minimum coin to 1 F7 SCSIUE tare ON Multi - Tare function ON OFF Multi - Tare function OFF

TVP-B_TVP-P Price Computing Scales Technical Manual

- 21 - F8 ISN This display will show XXXXX for indicating the internal counts. F9 Gra To set your local gravity value. F10 Reset Factory default settings F11 rS232 Mod E PC- 100 Protocol Type :CAS prin tr The scale RS232 protocol will be determined by the Baud & Pr settings EP50 accumulation function enable,and press M+ key to send data to receipt printer Lp50 accumulation function enable,and press M+ key to send data to label printer POS Protocol Type :POS oFF RS232 function disable Cont Continues data transmission StC Stable data sending continues tole do Protocol Type 1: Toledo ncie cr Protocol Type 2: NCI-ECR ncig en Protocol Type 3: NCI-General tec Protocol Type 4: TEC easy Protocol Type 5: Easy Weigh baud Set baud rate to( 1200/2400/4800/9600/19200/38

TVP-B_TVP-P Price Computing Scales Technical Manual

- 22 - 400/115200) Pr 8n1 8 data bits, no verify, 1 stop bit 7E1 7 data bits, Even verify, 1 stop bit 7o1 7 data bits, Odd verify, 1 stop bit F12 change CHA NGE ON To set change function on OFF To set change function off Press key to choose "kg" ,"lb" or "oz” unit in normal weighing mode, capacity will be show in kg , lb or oz values.

TVP-B_TVP-P Price Computing Scales Technical Manual

- 23 - 8. CALIBRATION Turn on the scale. Press and hold key during the self test. Display will show “Pn” briefly PIN is activated. Press the PIN number to get into the parameter menu. The default PIN number is “0000” 1.Press numeric key 0 four times , display will be shown Pn - - - - 2.Press key to confirm, It will enter into the parameter settings and will be Show “menu unit kg” a.If calibrating in kg.,continue step 3 b.If calibrating in lb.,press key ,lb will be show on the display 3.Press key to confirm , display will be show “f0 cal” Press calibration switch to enable settings,the calibration switch is locating below the scale 4.Remove the goods from the platform and make sure STABLE indication shows on the display. 5.Press key to confirm,display will be show “unload” 6.Press key to confirm ,display will be show ,CAP load XX 7.If necessary, press key to select the calibration weight value and then place the calibration weight on the platform. 8.Press key to confirm when display gets stable, display will be show “PASS” 9.Calibration finished and display will come to F0 Cal

TVP-B_TVP-P Price Computing Scales Technical Manual

- 24 - 10.Remove calibration weight from the platform. 11.Press key to go back to the weighing mode. If display will be shown any error or incorrect value, repeat the procedure again.

TVP-B_TVP-P Price Computing Scales Technical Manual

- 25 - 9. RS 232 OUTPUT The TVP-B& TVP-P Series of scales can be ordered with a standard RS-232 output. It can be connected to DEP-50 receipt printer &DLP-50 label printer 9.1. Print Format

TVP-B_TVP-P Price Computing Scales Technical Manual

- 26 - 10. ERROR CODES Error Message Description Solution ----- Maximum load exceeded Unload or reduce weight Err 1 Incorrect date Enter the date by using format “yy;mm:dd” Err 2 Incorrect time Enter the time by using format “hh:mm:ss” Err 4 Zero setting error Zero setting range exceeded due to switching on.(4%max) Make sure platform empty. Err 5 Key board error Check the keys and connecter. Err 6 A/D value out of range Make sure platform empty and check the pan is installed proper. Check the load cell connectors. Err 7 Percentage error Value should be (0.01% weight must > 0.5d) Err 9 Unstable Reading Check any air variation, vibration, RF noise and touching some where. Check the load cell and connectors. Err 10 Communication error No data (RS-232, continuous communication) Err 15 Enter gravity error Gravity rang(0.9~1.0)

TVP-B_TVP-P Price Computing Scales Technical Manual

- 27 - Err 17 Tare out of range Remove the load and restart scale again. Err19 Initialize zero error Calibration the scale. --ol-- Over range Remove the load. Re calibrate Fai l h / fai l l Calibration Error Re calibrate Err p Printer error Check the printer and settings Ba lo / lo ba Battery low Re charge battery, check the voltages.