YOKOGAWA CA700 Getting Started Manual
Read Online
Read the YOKOGAWA CA700 Getting Started Manual online using the built-in PDF viewer.
Text of the manual
Getting Started Guide
nbn Austria GmbH
Thank you for purchasing YOKOGAWA products.
YOKOGAWA provides registered users with a variety of information and services.
Please allow us to serve you best by completing the product registration form
accessible from our website.
http://tmi.yokogawa.com/
PIM 103-04E
Thank you for purchasing the CA700 pressure calibrator. This getting started guide primarily explains
the handling precautions and basic operations of the CA700. To ensure correct use, please read this
manual thoroughly before beginning operation.
After reading this manual, keep it in a safe place. The following manuals, including this one, are
provided as manuals for the CA700. Please read all manuals.
Manual Title
Manual No.
Description
CA700
Pressure Calibrator
User’s Manual
IM CA700-01EN
The manual explains all the CA700 features.
It is included in the accompanying CD.
CA700
Pressure Calibrator
Getting Started Guide
IM CA700-02EN
This guide. Provided as a printed manual. This guide
explains the handling precautions, basic operations, and
specifications of the CA700.
CA700
Pressure Calibrator
IM CA700-92Z1
Document for China
The “-EN” in the manual number is the language code.
Contact information of Yokogawa offices worldwide is provided on the following sheet.
Document Description
Description
PIM 113-01Z2
List of worldwide contacts
Notes
• The contents of this manual are subject to change without prior notice as a result of continuing
improvements to the instrument’s performance and functionality. The figures given in this manual
may differ from those that actually appear on your screen.
• Every effort has been made in the preparation of this manual to ensure the accuracy of its
contents. However, should you have any questions or find any errors, please contact your nearest
YOKOGAWA dealer.
• Copying or reproducing all or any part of the contents of this manual without the permission of
YOKOGAWA is strictly prohibited.
Trademarks
• Microsoft, Internet Explorer, Windows, Windows 7, Windows 8, and Windows 10 are either
registered trademarks or trademarks of Microsoft Corporation in the United States and/or other
countries.
• Adobe, Acrobat, and PostScript are either registered trademarks or trademarks of Adobe Systems
Incorporated.
• HART is a registered trademark of FieldComm Group.
• In this manual, the TM and ® symbols do not accompany their respective®registered trademark or
trademark names.
• Other company and product names are registered trademarks or trademarks of their respective
holders.
6th Edition: October 2018 (YMI)
All Rights Reserved, Copyright © 2013 Yokogawa Test & Measurement Corporation
• 1st Edition: August 2013
• 2nd Edition: September 2015
• 3rd Edition: June 2017
• 4th Edition: October 2017
• 5th Edition: June 2018
• 6th Edition: October 2018
Checking the Contents of the Package
Unpack the box and check the contents before operating the instrument. If the wrong items have been
delivered, if items are missing, or if there is a problem with the appearance of the items, contact your
nearest YOKOGAWA dealer.
CA700
Check that the product that you received is what you ordered by referring to the model name and suffix
code given on the name plate on the rear panel.
MODEL
Suffix Code
Specifications
CA700
Pressure calibrator
-E
For all countries except Japan
Gauge pressure
-01
-02
-03
200 kPa guage model
1000 kPa guage model
3500 kPa guage model
Pressure unit
-U1
-U2
SI units
SI units and non-SI units
Input connection
-P1
-P2
Rc1/4 female threads
1/4NPT female threads
No. (Instrument number)
When contacting the dealer from which you purchased the instrument, please give them the instrument
number.
Standard Accessories
The instrument is shipped with the following accessories. Make sure that all accessories are present
and undamaged.
Item
Model/Part No.
Quantity
Specifications and Notes
Signal cable
98064
1
Red/Black pair
Shoulder strap
B8070CY
1
—
Connector
91080
1
For -P1(Rc1/4)
91081
1
For -P1(Rc1/4)
91082
1
For -P2(1/4NPT female threads)
Dry cells
A1070EB
6
Alkaline “AA” (LR6) 1.5 V
Accessory case
B9108XA
1
—
Ferrite core
A1193MN
2
Cap
L4060CL
1
For the pressure input port (comes attached to the
CA700)
CD-ROM (User’s Manuals)
L3060TD
1
Contains PDFs of the user’s manuals and USB
driver
User’s manual
IM CA700-02EN
1
This guide.
IM CA700-92Z1
1
Document for China
PIM 113-01Z2
1
List of worldwide contacts
Standard accessories are not covered by warranty of this instrument.
CD-ROM (User’s Manuals)
The CD-ROM contains PDF files of the following manuals. To view these user’s manuals, you need
Adobe Reader 5.0 or later.
Japanese
• Model CA700 Pressure Calibrator User’s Manual
IM CA700-01JA
English
• Model CA700 Pressure Calibrator User’s Manual
IM CA700-01EN
WARNING
Never play this CD-ROM, which contains the user’s manuals, in an audio CD player. Doing so
may cause loss of hearing or speaker damage due to the large sounds that may be produced.
French
AVERTISSEMENT
Ce CD contient les manuels d'utilisation. Ne jamais insérer ce CD dans un lecteur de CD
audio. Cela pourrait entraîner une perte d'audition ou l'endommagement des enceintes en
raison du volume potentiellement élevé des sons produits.
Checking the Contents of the Package
Optional Accessories (Sold separately)
The following optional accessories are available for purchase separately. For information about
ordering accessories, contact your nearest YOKOGAWA dealer.
Item
Model/
Part No.
Min. Q’ty
Specifications
Manual No.
Carrying case
93050
1
CA700, accessory case
-
Grabber clip
98025
1
Red/Black pair, separate type (2.0 m)
-
Grabber clip
98026
1
Red/Black pair, separate type (2.0 m)
-
Cleaning unit
91040
1
Pressure input port Rc1/8 female thread,
2 locations (for -P1 and -P2)
-
Cleaning unit
91041
1
Pressure input port 1/8NPT female
thread, 2 locations (for -P1 and -P2)
-
Connector
91080
1
R1/4 male to NPT 1/8 female
-
Connector
91081
1
R1/4 male to NPT 1/4 female
-
Connector
91082
1
NPT 1/4 male to NPT 1/8 female
-
Low pressure pump kit
91050
1
A set containing 91051, case (93052),
and connector set (91052)
-
Low pressure pump
91051
1
-83 Pa to 700 kPa
-
Connector set (low pressure
pump)
91052
1
Connector set for 91051
-
Pneumatic pressure pump kit
91055
1
A set containing 91056, case (93053),
and connector set (91057)
-
Pneumatic pressure pump
91056
1
-83 Pa to 4000 kPa
-
Connector set (pneumatic
pressure pump)
91057
1
Connector set for 91056
-
Hydraulic pressure pump kit
91060
1
A set containing 91061, case (93053),
and connector set (91062)
-
Hydraulic pressure pump
91061
1
-0 Pa to 70 MPa
-
Connector set (hydraulic
pressure pump)
91062
1
Connector set for 91061
-
Case (for 91051)
93052
1
For storing 91051 and 91052
-
Case (for 91056 and 91061)
93053
1
For storing 91056 and 91057, or 91061
and 91062
-
External pressure sensor1
PM100
1
-05: 16 MPa range shield gauge model
-06: 70 MPa range shield gauge model
PM100-01EN
Optional accessories(sold separately) are not covered by warranty of this instrument.
1: PM100-*-05: available in 1.10 or later firmware versions of the CA700.
PM100-*-06: available in 1.20 or later firmware versions of the CA700.
You can download the latest firmware version from our website.
Checking the Contents of the Package
Conventions Used in This Manual
Unit
k: Denotes 1000.
Example: 100 kS/s (sample rate)
K: Denotes 1024.
Example: 720 KB (file size)
Displayed Characters
Bold characters in procedural explanations are used to indicate panel keys and soft keys that are used
in the procedure and menu items that appear on the screen.
Notes
The notes and cautions in this manual are categorized using the following symbols.
mproper handling or use can lead to injury to the user or damage to
the instrument. This symbol appears on the instrument to indicate
that the user must refer to the user’s manual for special instructions.
The same symbol appears in the corresponding place in the user’s
manual to identify those instructions. In the user’s manual, the symbol
is used in conjunction with the word “WARNING” or “CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or
fatal injury to the user, and precautions that can be taken to prevent
such occurrences.
CAUTION
Calls attention to actions or conditions that could cause light injury
to the user or cause damage to the instrument or user’s data, and
precautions that can be taken to prevent such occurrences.
Note
Calls attention to information that is important for the proper operation
of the instrument.
French
Une manipulation ou une utilisation incorrectes risquent de
blesser l’utilisateur ou d’endommager l’instrument. Ce symbole
apparaît sur l’instrument pour indiquer à l’utilisateur qu’il doit se
reporter au manuel de l’utilisateur afin d’y lire les instructions
spécifiques correspondantes. Ce même symbole apparaît à la
section correspondante du manuel de l’utilisateur pour signaler
lesdites instructions. Dans le manuel de l’utilisateur, ce symbole est
accompagné des termes AVERTISSEMENT et ATTENTION.
AVERTISSEMENT Attire l’attention sur des gestes ou des conditions susceptibles
de provoquer des blessures graves (voire mortelles), et sur les
précautions de sécurité pouvant prévenir de tels accidents.
ATTENTION
Attire l’attention sur des gestes ou des conditions susceptibles de
provoquer des blessures légères ou d’endommager l’instrument
ou les données de l’utilisateur, et sur les précautions de sécurité
susceptibles de prévenir de tels accidents.
This product is designed to be used by a person with specialized knowledge.
The general safety precautions described herein must be observed during all phases of operation.
If the instrument is used in a manner not specified in this manual, the protection provided by the
instrument may be impaired. YOKOGAWA assumes no liability for the customer’s failure to comply
with these requirements.
This manual is an essential part of the product; keep it in a safe place for future reference. Yokogawa
Electric Corporation assumes no liability for the customer’s failure to comply with these requirements.
The following symbols are used on this instrument.
Handle with care. Refer to the user’s manual or service manual. This symbol appears on
dangerous locations on the instrument which require special instructions for proper handling
or use. The same symbol appears in the corresponding place in the manual to identify those
instructions.
Ground (earth) or functional ground terminal (do not use this terminal as a protective ground
terminal)
Alternating current
Direct current
Power switch
French
À manipuler délicatement. Toujours se reporter aux manuels d’utilisation et d’entretien. Ce
symbole a été apposé aux endroits dangereux de l’instrument pour lesquels des consignes
spéciales d’utilisation ou de manipulation ont été émises. Le même symbole apparaît à l’endroit
correspondant du manuel pour identifier les consignes qui s’y rapportent.
Borne de terre ou borne de terre fonctionnelle (ne pas utiliser cette borne comme prise de
terre.)
Courant alternatif
Courant direct
l’interrupteur d’alimentation
Failure to comply with the precautions below could lead to injury
or death or damage to the instrument.
WARNING
Use the Instrument Only for Its Intended Purpose
This instrument is equipped with DC current and DC voltage measurement and generation
features as well as a pressure measurement feature. It is a calibrator for pressure devices.
Use the instrument only for measuring and generating DC current and DC voltage, measuring
pressure, and calibrating pressure devices.
Check the Physical Appearance
Do not use the instrument if there is a problem with its physical appearance.
Do Not Operate in an Explosive Atmosphere
This instrument is not explosion-proof.
Do not operate the instrument in the presence of flammable gases or vapors. Doing so is
extremely dangerous.
Do Not Remove Covers or Disassemble or Alter the Instrument
Removing covers and disassembling or altering the instrument are strictly prohibited.
Some sections inside the instrument have high voltages that are extremely dangerous. For
internal inspection and adjustment, contact your nearest YOKOGAWA dealer.
Measuring High Pressure Fluid
• Use piping and pressure connectors that can withstand the pressure to be measured.
• Make sure that there are no leaks from the piping, connectors, and joints and that the joints
are not loose. If the fluid under measurement leaks or if a joint comes loose, the pressure
can endanger the user or the surrounding instruments. Note that higher the pressure,
greater the danger.
• Depending on the amount or type of gas, if you are handling gas that is 1 MPa or higher,
safety laws related to high pressure gas may require supervision.
• Do not measure flammable, explosive, poisonous, or corrosive liquids.
Such an act can endanger the user.
Observer the Pressure Limit
Do not apply pressure exceeding the allowable input range. Doing so may cause damage to
the instrument.
Measurement Category
The measurement category of this instrument is Other (O). Do not use it to measure the main
power supply or locations that fall under Measurement Categories II, III, and IV.
Install or Use the Instrument in Appropriate Locations
• The instrument complies with protection level IP54. Do not install the instrument in
locations whose level exceeds this protection level.
• Install the instrument so that you can immediately remove the batteries if an abnormal or
dangerous condition occurs.
CAUTION
• Do not use the instrument to measure gas or liquids that can corrode the piping material,
high temperature liquids (50°C or higher) or gas-liquid mixtures.
If you are measuring gas, make sure the gas is dry and clean. Do not measure air with high
moisture or high oil content.
Safety Precautions
• For safety and sanitary reasons, do not use the instrument to measure liquids for drinking.
• This instrument has been designed to withstand physical shock, but to maintain high
accuracy, handle the instrument with care (protect the instrument from physical shock).
• Do not use the instrument where the ambient temperature drastically fluctuates. Such
environment can cause measurement errors.
• Using the instrument where there is wind or air flow may degrade the measurement
accuracy.
Operating Environment Limitations
This product is a Class A (for industrial environments) product. Operation of this product in a
residential area may cause radio interference in which case the user will be required to correct
the interference.
French
AVERTISSEMENT
Utiliser l’instrument aux seules fins pour lesquelles il est prévu
Cet instrument est équipé de fonctions de génération et de mesure de tension c.c. et de
courant c.c., ainsi que d’une fonction de mesure de pression. Il s’agit d’un calibreur pour
dispositifs de pression.
Utiliser cet instrument uniquement pour mesurer et générer un courant c.c. et une tension c.c.,
mesurer la pression et calibrer des dispositifs de pression.
Inspecter l’apparence physique
Ne pas utiliser l’instrument si son intégrité physique semble être compromise.
Ne pas utiliser dans un environnement explosif
Cet instrument n’est pas antidéflagrant.
Ne pas utiliser l’instrument en présence de gaz ou de vapeurs inflammables. Cela pourrait
être extrêmement dangereux.
Ne pas retirer le capot, ni démonter ou modifier l’instrument
Seul le personnel YOKOGAWA qualifié est habilité à retirer le capot et à démonter ou modifier
l’instrument. Certains composants à l’intérieur de l’instrument sont à haute tension et par
conséquent, représentent un danger.
Mesure du fluide haute pression
• Utiliser une tuyauterie et des connecteurs pression pouvant résister à la pression à
mesurer.
• S’assurer de l’absence de fuites au niveau de la tuyauterie, des connecteurs et des joints,
et vérifier que les joints ne sont pas desserrés. En cas de fuite du fluide mesuré ou de
desserrage d’un joint, la pression risque de mettre en danger l’utilisateur ou les instruments
environnants. Il est à noter que plus la pression est élevée, plus le danger est important.
• En cas de manipulation de gaz à 1MPa ou plus, la législation relative à la sécurité des gaz
haute pression peut rendre une surveillance obligatoire, en fonction de la quantité ou du
type de gaz.
• Ne pas mesurer des liquides inflammables, toxiques ou corrosifs.
Une telle action peut s’avérer dangereuse pour l’utilisateur.
Respecter la limite de pression
Ne pas appliquer de pression supérieure à la plage d’entrée autorisée. Le cas échéant, un
endommagement de l’équipement risquerait de se produire.
Safety Precautions
Catégorie de mesure
Sales in Each Country or Region
Waste Electrical and Electronic Equipment
Waste Electrical and Electronic Equipment (WEEE)
(This directive is valid only in the EU.)
This product complies with the WEEE Directive marking requirement. This marking indicates
that you must not discard this electrical/electronic product in domestic household waste.
Product Category
With reference to the equipment types in the WEEE directive, this product is classified as a
“Monitoring and control instruments” product.
Do not dispose in domestic household waste. When disposing products in the EU, contact your
local Yokogawa Europe B. V. office.
New EU Battery Directive
New EU Battery Directive
(This directive is valid only in the EU.)
Batteries are included in this product. This marking indicates they shall be sorted out and
collected as ordained in the EU battery directive
Battery type: Alkaline dry cell, size “AA” (LR6) 1.5V
When you remove batteries from this product and dispose them, discard them in
accordance with domestic law concerning disposal.
Take the proper action to dispose batteries in accordance with the established collection
system in the EU.
How to remove batteries safely
See section 2.3, “Inserting Batteries and Turning the Power On and Off.”
Battery type: Primary lithium battery for memory back up
You cannot replace batteries by yourself. If you are in the EU, contact your local
Yokogawa Europe B. V. office.
Pressure Equipment Directive
The CA700 is categorized as Sound Engineering Practice(SEP) under the Pressure Equipment
Directive(PED).
Authorized Representative in the EEA
Yokogawa Europe B. V. is the authorized representative of Yokogawa Test & Measurement Corporation
in the EEA for this product. To contact Yokogawa Europe B. V., see the separate list of worldwide
contacts, PIM 113-01Z2.
Checking the Contents of the Package............................................................................................ iii
Conventions Used in This Manual....................................................................................................vi
Safety Precautions........................................................................................................................... vii
Sales in Each Country or Region......................................................................................................xi
Chapter 1 Component Names and Functions
1.1
Front Panel, Top Panel, and Rear Panel........................................................................... 1-1
1.2
Display............................................................................................................................... 1-3
Chapter 2 Making Preparations for Measurements
2.1
Handling Precautions........................................................................................................ 2-1
2.2
Installing the Instrument.................................................................................................... 2-3
2.3
Inserting Batteries and Turning the Power On and Off...................................................... 2-6
2.4
Connecting Source and Measurement Leads................................................................... 2-8
2.5
Setting the Date and Time............................................................................................... 2-14
2.6
Performing Zero Calibration............................................................................................ 2-16
Chapter 3 Calibrating the Pressure Transmitter
3.1
Connecting to the Pressure Transmitter............................................................................ 3-1
3.2
Setting the Device Information and the Calibration Conditions of the Pressure Transmitter...
3-3
3.3
Calibrating the Pressure Transmitter............................................................................... 3-12
Chapter 4 Troubleshooting, Maintenance, and Inspection
4.1
If a Problem Occurs........................................................................................................... 4-1
4.2
Error Codes, Error Messages, and Actions....................................................................... 4-2
4.3
Viewing System Information (Overview)........................................................................... 4-3
4.4
Recommended Part Replacement and Calibration........................................................... 4-5
4.5
Disposing of the Instrument............................................................................................... 4-6
Chapter 5 Specifications
5.1
Pressure Measurement Feature........................................................................................ 5-1
5.2
DC Current and DC Voltage Source Features.................................................................. 5-2
5.3
DC Current and DC Voltage Measurement Features........................................................ 5-2
5.4
Number of Saved Data Values.......................................................................................... 5-3
5.5
General and Common Specifications................................................................................ 5-4
5.6
External Dimensions......................................................................................................... 5-6
Component Names and Functions
IM CA700-02EN
1
2
3
4
5
6
App
Index
1.1
Front Panel, Top Panel, and Rear Panel
Front Panel
Direct keys
Voltage input
terminal
Current/Voltage
output terminal
Current input
terminal
Common terminal
Arrow keys
Press to change values,
move between digits, and
move the cursor.
ENTER key
Press to confirm procedures
and settings.
ESC key
Press to return to the
previous menu or to cancel
the current operation.
Function keys
Press to select the menu items that are
shown at the bottom of the display.
Power on/off key
Press to turn the CA700
on and off.
Backlight key
Turns on and off the LCD
backlight
LCD
Direct Keys
ZERO key
Press to perform zero point calibration for pressure measurement.
HOLD
MIN/
MAX
RELATIVE
SOURCE/
MEASURE
ZERO
HOLD Key
Press to hold the measured value in the display. When you press HOLD, all keys are disabled
except for the HOLD key, the Power ON/OFF key, and the Save and Logging Start function key.
MIN/MAX key
Press to hold the maximum and minimum values in the display or to clear them.
RELATIVE key
Press to display the difference between the measured value and the preset
reference value. When the difference is displayed, “REL” appears in the display.
SOURCE/MEASURE key
Press to switch between source and measure.
Chapter 1
Component Names and Functions
Pressure input port
USB type-B port
(Mini-B)
Used to control the CA700 from a
PC through communication
commands or to access the CA700
internal memory from a PC.
USB type-A port
Used to connect a USB
storage device
External pressure sensor input terminal
Receives signals from an external pressure sensor.
(not used until external pressure sensors are released)
USB port cover
Rear Panel
Battery holder
Holds six AA dry cells
1.1 Front Panel, Top Panel, and Rear Panel
Component Names and Functions
IM CA700-02EN
1
2
3
4
5
6
App
Index
1.2
Display
Top Menu
When you turn the power on, the top menu appears.
Measurement and source settings
Pressure transmitter calibration and
pressure switch calibration settings
File utility and Internal storage formatting
Displays USB, auto power-off, LCD
contrast, and measurement storage
settings, product information (overview)
and firmware upgrade.
Date
Time
Icon display area
(see page 1-6)
Selecting Measure and Source from the top menu shows a pressure, voltage, and current
measurement and voltage and current source displays. The top half of the display shows the pressure
measurement display (Display1), and the bottom half displays the current and voltage measurement/
source display (Display2).
Configuring the Pressure Measurement
When the External Pressure Sensor Is not Used
Display1
(pressure
measurement)
Pressure measurement
display
Leak pressure measurement
display
Display2
(voltage/current
measurement and
source)
When leak
pressure
measurement,
Display 2 is not
used.
When the External Pressure Sensor Is Used
Pressure measurement display
when the external pressure sensor is used
Leak pressure measurement display
when the external pressure sensor is used
Configuring the Current/Voltage Measurement
Current (mA) measurement
display
Loop current (mA LOOP)
measurement display
Voltage (V) measurement
display
Note
Selecting Scaling, Alarm, %Span, or Relative and then pressing ENTER shows the corresponding setup
menu.
1.2 Display
Component Names and Functions
IM CA700-02EN
1
2
3
4
5
6
App
Index
Configuring the Current/Voltage Source
Current source
(mA SOURCE) display
Voltage source
(V SOURCE) display
Current simulation
(mA SIMULATE) display
Step setting display
Switching between Display1 and Display2
In the pressure measurement, voltage/current measurement, or voltage/current source display,
pressing Display Change (F4) switches the display from showing Display1 and Display2 to showing
only Display1 or Display2.
Display1 and Display2
Display1
Display2
When only Display1 or Display2 is showing, pressing Setting (F5) will show the corresponding setup
display.
Pressure Transmitter/Pressure Switch Calibration Display
Selecting Calibrate from the top menu shows the pressure transmitter and pressure switch calibration
display.
Edit the calibration target information.
Select the calibration procedure.
Saves data before calibration
Saves data after calibration
Adjustment
1.2 Display
Selecting File from the top menu shows the file display.
Copy and delete files.
Format the Internal storage.
Basic Setting Display
Selecting Device Setting from the top menu shows the file display.
Basic settings (auto power-off, display contrast, USB, etc.)
Data saving options (interval, number of data points, etc.)
Product information (overview)
Firmware Upgrade (internal pressure sensor,
external pressure sensor)
Icon
The icon display area shows the following icons (marks) depending on the CA700 settings.
USB feature
Appears when USB communication is set to Function and USB Function is set
to Comm. (communication with the PC)
Appears when USB Connection is set to Function and USB Function is set to
Mass Storage (USB storage for the PC)
Appears when USB Connection is set to Host (USB storage device connected
to the CA700)
Sweep mode
Appears in step sweep mode
Appears in linear sweep mode
Remaining battery power
Appears when the auto-off feature is ON
Appears while holding
Appears when the internal resistor (250 Ω) is on
External pressure sensor
Appears when the external pressure sensor is connected
1.2 Display
Making Preparations for Measurements
2-1
IM CA700-02EN
1
2
3
4
5
6
App
Index
2.1
Handling Precautions
Safety Precautions
If you are using this instrument for the first time, make sure to read “Safety Precautions” on pages vii
and viii.
Do Not Remove the Case
Do not remove the case from the instrument. Some parts of the instrument use high voltages and
are extremely dangerous. For internal inspection and adjustment, contact your nearest YOKOGAWA
dealer.
Unplug If Abnormal Behavior Occurs
If you notice smoke or unusual odors coming from the instrument, immediately turn off the power and
remove the batteries. Then, contact your nearest YOKOGAWA dealer.
Operating Environment and Conditions
This instrument complies with the EMC standard under specific operating environment and operating
conditions. If the installation, wiring, and so on are not appropriate, the compliance conditions of the
EMC standard may not be met. In such cases, the user will be required to take appropriate measures.
General Handling Precautions
Do Not Place Objects on Top of the Instrument
Never place objects such as other instruments or objects that contain water on top of the instrument.
Doing so may damage the instrument.
Do Not Subject the Inputs to Mechanical Shock
Applying shock to the input connectors, probes, etc., can cause electrical noise to enter the instrument
through the signal lines.
Do Not Damage the LCD
Because the LCD is very vulnerable and can be easily scratched, do not allow any sharp objects near
it. Also, the LCD should not be exposed to vibrations or shocks.
Remove the Batteries during Extended Non-Use
Remove the batteries.
Chapter 2
Making Preparations for Measurements
When Carrying the Instrument
First, turn off the item under measurement. Then, turn off the CA700. Remove all lead cables. Use the
carrying case to carry the instrument.
When Cleaning the Instrument
When cleaning the case or the operation panel, gently wipe the outer surface using a damp, well-
wrung, soft, clean cloth. The instrument can malfunction if water enters inside the instrument.
Do not use volatile chemicals such as benzene or thinner for cleaning, as they may lead to
discoloration or deformation.
Other Precautions
• Keep electrically charged objects away from the input terminals. They may damage the internal
circuitry.
• Do not cover the case or operation panel with a volatile material or leave rubber or vinyl products in
contact with the case or operation panel for a long time.
• The operation panel is made of thermoplastics resin. Keep soldering iron and other heating
elements away from the operation panel.
• For precautions related to the handling of batteries, see section 2.3, “Installing Batteries and Turning
the Power On and Off.”
• Do not use the instrument with the battery holder open.
Storage Precautions
Storage Location
Avoid the following kinds of places for storing the instrument:
• Where the temperature falls outside the storage temperature and humidity ranges
• In direct sunlight or near heat sources
• In an environment with excessive amounts of soot, steam, dust, or corrosive gas
• In an environment that is subject to large levels of mechanical vibration
• On an unstable surface
• Where an excessive amount of soot, dust, salt, or iron is present
Other Precautions
When storing the instrument, attach the supplied cap to the pressure input port.
2.1 Handling Precautions
Making Preparations for Measurements
2-3
IM CA700-02EN
1
2
3
4
5
6
App
Index
2.2
Installing the Instrument
WARNING
Install the instrument so that you can immediately turn off the power if an abnormal or
dangerous condition occurs.
Do not use the instrument to measure locations that fall under Measurement Categories II, III,
and IV.
CAUTION
• IThe instrument complies with protection level IP54 when protection caps are used. Do not
install the instrument in an environment whose level exceeds this protection level. Water or
dust can enter inside the instrument and cause a malfunction.
• This instrument is equipped with voltage and current source and measurement features.
Do not use the instrument when it is wet. Doing so may damage the instrument.
French
AVERTISSEMENT
• Installer l’instrument de façon à pouvoir le mettre immédiatement hors tension en cas
d’apparition d’une condition anormale ou dangereuse.
• Ne pas utiliser l’instrument pour mesurer des emplacements appartenant aux catégories
de mesure II, III, et IV.
ATTENTION
• L’instrument est conforme au niveau de protection IP54 lorsque des capuchons de
protection sont utilisés. Ne pas installer l’instrument à un emplacement dont le niveau
est supérieur à ce niveau de protection. De l’eau ou de la poussière risque de pénétrer à
l’intérieur de l’instrument et de provoquer un dysfonctionnement.
• Cet instrument est doté de fonctions de mesure et de source de courant et de tension.
Ne pas utiliser l’équipement lorsqu’il est mouillé. Le cas échéant, un endommagement de
l’équipement risquerait de se produire.
Installation Conditions
Install the instrument in a place that meets the following conditions.
Flat, Even Surface
To measure pressure using the pressure sensor in the instrument, install the instrument on a stable
surface that is level in all directions. Pressure may not be measured correctly when the instrument is
placed in an unstable or inclined place.
Operating Altitude and Ambient Temperature and Humidity
Use the instrument in the following environment.
Ambient temperature
10°C to 50°C
Ambient humidity
20% RH to 80% RH; no condensation
Operating altitude
2000 m or less
Note
• To ensure high measurement accuracy, operate the instrument within the following ranges: 23 ± 3°C.
• When using the instrument in a place where the ambient humidity is 30% or less, take measures to
prevent static electricity such as using an anti-static mat.
• Condensation may occur if the instrument is moved to another place where the ambient temperature or
humidity is higher, or if the temperature changes rapidly. In such cases, before you use the instrument,
allow it to adjust to the surrounding temperature for at least an hour.
Do Not Install the Instrument in the Following Places
• In direct sunlight or near heat sources
• In an environment with excessive amounts of soot, steam, dust, or corrosive gas
• Near strong magnetic field sources
• Near noise sources, such as high-voltage equipment or power lines
• In an environment that is subject to large levels of mechanical vibration
• On an unstable surface
• In an environment where ignition or explosion may occur, such as in explosive gas
Protection Level Using Protection Caps
This instrument complies* with protection level IP54.
* When the USB port cover is closed and the external pressure sensor input cap is attached.
IP54
International Protection
Splashing of water (liquid ingress protection)
Dust protected (solid particle protection)
If the USB port cover is open or the external pressure sensor input cap is not attached, the instrument
does not comply with IP54.
Installation Orientation
To measure pressure, install the instrument horizontally with the front panel facing up or using the rear
panel stand.
After installation, perform zero calibration according to section 2.6.
Measurement Category
The measurement category of this instrument is Other (O).
Measurement
Category
Description
Notes
O (None, Other)
Other circuits that are not directly connected to the
mains.
Circuits that are not powered from
the mains
CAT II
For measurements performed on circuits that are
connected to low-voltage installations
Household appliances, portable
tools, etc.
CAT III
For measuring facility circuits
Distribution boards, circuit
breakers, etc.
CAT IV
For measurements performed on power source circuits Entrance cables, cable systems,
etc.
2.2 Installing the Instrument
Making Preparations for Measurements
2-5
IM CA700-02EN
1
2
3
4
5
6
App
Index
Attaching the Shoulder Belt
Attach the strap to the loops on both the upper-left and upper-right sides of the CA700.
Pass the shoulder strap through the loops and then the buckle as shown in the figure. Attach the left
and right sides in the same manner.
Pass the belt back through the buckle and tighten it.
Strap loop
Buckle
2.2 Installing the Instrument
Inserting Batteries and Turning the Power On
and Off
WARNING
• Insert batteries with the correct polarity. Otherwise, the batteries may leak, heat up, or
burst.
• Do not mix new and old batteries or mix different brands or types of batteries. The batteries
may leak, heat up, or burst due to their characteristic differences.
CAUTION
• If you do not intend to use the instrument for a long time, remove the batteries from the
instrument. Leaving the batteries in the instrument may cause the batteries to leak.
• If the batteries go flat during use, the measurement data will not be saved. We recommend
that you replace the batteries as soon as they start to run low.
French
AVERTISSEMENT
• Insérer les batteries en observant la polarité correcte. À défaut, les batteries risquent de
fuir, de chauffer ou d’éclater.
• Ne pas mélanger des batteries neuves et des batteries usagées, ni des batteries de
marques ou de types différents. Les batteries risquent de fuir, de chauffer ou d’éclater en
raison de leurs différentes caractéristiques.
ATTENTION
• Si l’instrument ne doit pas être utilisé pendant une période prolongée, retirer les batteries
de l’instrument. Si les batteries ne sont pas retirées de l’instrument, elles risquent de fuir.
• En cas de décharge complète des batteries en cours d’utilisation, les données de mesure
ne sont pas enregistrées. Il est recommandé de remplacer les batteries dès que leur
charge commence à être basse.
Inserting Alkaline Dry Cells
1. Check that the power is turned off and that cables are not connected.
2. Using a Phillips screwdriver, unfasten the screws holding the battery cover on the rear panel,
and open the battery cover.
3. Insert dry cells into the battery holder. Pay attention to their polarity.
Compatible dry cells: Six 1.5 V AA alkaline dry cells
4. Close the battery cover, and fasten it with the screws.
Making Preparations for Measurements
2-7
IM CA700-02EN
1
2
3
4
5
6
App
Index
Removing Alkaline Dry Cells
1. Check that the power is turned off and that cables are not connected.
2. Using a Phillips screwdriver, unfasten the screws holding the battery cover on the rear panel,
and open the battery cover.
3. Remove the dry cells from the battery holder.
4. Close the battery cover, and fasten it with the screws.
Remaining Battery Power Indicator
The remaining battery power is displayed with an indicator as shown below.
Remaining power High
Low
If the remaining power falls to zero during measurement, the measurement data at that point may not
be saved. If the remaining power starts to run low, replace the dry cells as soon as possible.
Battery consumption increases when current or voltage is generated. You should keep this in mind
when you use the current or voltage source or the loop power supply.
Turning the Power On
Before Turning On the Power, Check That:
• The instrument is installed properly.
See section 2.2, “Installing the Instrument.”
• The batteries are inserted properly.
See the previous page.
Turning the Power On
1. Press the power on/off key on the front panel.
Operations Performed When the Power Is Turned On
When the power is turned on, a self-test start automatically. After the self-test and calibration finish
successfully, the top menu appears.
When the Power-on Operation Does Not Finish Normally
Turn off the power, and check the following items.
• Are the dry cells inserted properly?
• Are you using new and old dry cells together?
• Are you using batteries of different types or different brands together?
If the instrument still does not work properly, contact your nearest YOKOGAWA dealer for repairs.
Note
• After turning off the power, wait at least 10 seconds before you turn it back on.
• It may take a few seconds for the startup screen to appear.
Turning the Power Off
Turning the Power Off
1. Hold down the power on/off key until the message “Power Off?” appears.
2. Press ENTER. The power turns off.
Operations Performed When the Power Is Turned Off
The settings immediately before the power is turned off are stored. Therefore, the next time the power
is turned on, the instrument will start with those settings.
To Make Accurate Measurements
• Allow the instrument to warm up for at least 30 minutes after turning on the power.
2.3 Inserting Batteries and Turning the Power On and Off
Connecting Source and Measurement Leads
WARNING
• Always turn off the power of the device under measurement before connecting the device
to the instrument. It is extremely dangerous to connect or disconnect a measuring lead
while the device under measurement is on.
• Do not apply voltage or current that exceeds the maximum input voltage or maximum input
current.
Maximum input voltage: 50 Vpk (to ground)
Maximum input current: 120 mA
• Before connecting source leads to the source terminals, turn off the instrument.
• Do not apply voltage or current to the source terminals. Doing so may cause electric shock
or damage the instrument.
French
AVERTISSEMENT
• Toujours mettre le dispositif hors tension avant de le connecter à l’instrument. Il est
extrêmement dangereux de connecter ou de déconnecter un câble de mesure lorsque le
dispositif mesuré est sous tension.
• Ne pas appliquer de tension ni de courant supérieurs à la tension/au courant d’entrée
maximum.
Tension d’entrée maximum : 50 Vpk (à la masse)
Courant d’entrée maximum : 120 mA
• Avant de connecter les câbles de source aux bornes de source, mettre l’instrument hors
tension.
• Ne pas appliquer de tension ni de courant aux bornes de source. Le cas échéant, un choc
électrique et/ou un endommagement de l’instrument risque(nt) de se produire.
Making Preparations for Measurements
2-9
IM CA700-02EN
1
2
3
4
5
6
App
Index
Connecting Current and Voltage Source and Measurement Leads
Connect the source and measurement leads (L4059PR) supplied with the instrument to the current
and voltage input or output terminals.
Current and Voltage Source
MEASURE
SOURCE
mA / V
COM
mA
V
DC120 mA
MAX
OUTPUT
DC mA / V
42 Vpk
MAX
LOOP POWER
DC 50V MAX
50 Vpk
MAX
Current/Voltage output
H
L
Red
Black
Current and Voltage Measurement
MEASURE
SOURCE
mA / V
COM
mA
V
DC120 mA
MAX
OUTPUT
DC mA / V
42 Vpk
MAX
LOOP POWER
DC 50V MAX
50 Vpk
MAX
MEASURE
SOURCE
mA / V
COM
mA
V
DC120 mA
MAX
OUTPUT
DC mA / V
42 Vpk
MAX
LOOP POWER
DC 50V MAX
50 Vpk
MAX
Current input
H
L
Voltage input
H
L
Red
Black
Red
Black
mA Loop Measurement and Pressure Switch Resistance Measurement
MEASURE
SOURCE
mA / V
COM
mA
V
DC120 mA
MAX
OUTPUT
DC mA / V
42 Vpk
MAX
LOOP POWER
DC 50V MAX
50 Vpk
MAX
mA Loop measurement
H
L
Red
Black
MEASURE
SOURCE
mA / V
COM
mA
V
DC120 mA
MAX
OUTPUT
DC mA / V
42 Vpk
MAX
LOOP POWER
DC 50V MAX
50 Vpk
MAX
Pressure switch test
H
L
Red
Black
2.4 Connecting Source and Measurement Leads
Connecting to the Pressure Input Port
WARNING
• Do not apply pressure over the allowable input range. Excessive pressure may cause injury
or damage to the instrument.
Model
CA700-*-01
CA700-*-02
CA700-*-03
Allowable input
Negative pressure
2.7 kPa abs
2.7 kPa abs
2.7 kPa abs
Positive pressure
500 kPa
3000 kPa
4500 kPa
• Before applying pressure to the instrument, make sure that tubing is connected properly.
Improper connection may cause gas or liquid to leak, which may in turn cause injury or
damage to the instrument.
• After use, be sure to depressurize adequately so that compressed gas or liquid does not
burst out. Then remove tubing.
• The withstand pressure of the connector supplied with the instrument is the same as the
instrument’s allowable input. Do not use the connector with other instruments.
CAUTION
When joining the connector, using a spanner only on the connector side may break the inside
of the instrument. Be sure to use another spanner on the cut-out of the input port to tighten
the connector.
French
AVERTISSEMENT
• Ne pas appliquer de pression supérieure à la plage d’entrée autorisée. Une pression
excessive risquerait de provoquer des blessures ou d’endommager l’instrument.
Modèle
CA700-*-01
CA700-*-02
CA700-*-03
Entrée autorisée Pression négative
2,7 kPa abs
2,7 kPa abs
2,7 kPa abs
Pression positive
500 kPa
3000 kPa
4500 kPa
• Avant de mettre l’instrument sous pression, s’assurer que les tubes sont correctement
connectés. Une connexion incorrecte peut provoquer une fuite de gaz ou de liquide, ce qui
à son tour peut être à l’origine de blessures ou d’un endommagement de l’instrument.
• Après utilisation, veiller à effectuer une dépressurisation correcte, de façon à éviter que le
gaz ou le liquide comprimé ne jaillisse hors de l’instrument. Retirer ensuite les tubes.
• La pression de résistance du connecteur fourni avec l’instrument est identique à l’entrée
autorisée pour l’instrument. Ne pas utiliser le connecteur avec d’autres instruments.
ATTENTION
L’utilisation d’une clé uniquement sur le côté connecteur lors du raccordement du connecteur
risque de casser l’intérieur de l’instrument. Pour serrer le connecteur, veiller à utiliser une
autre clé sur la découpe du port d’entrée.
2.4 Connecting Source and Measurement Leads
Making Preparations for Measurements
2-11
IM CA700-02EN
1
2
3
4
5
6
App
Index
The pressure input port of this instrument has Rc1/4 (-P1) or 1/4NPT female threads (-P2). If
the tubing connector does not match the port, use an accompany adapter.
91080 (connector for -P1 model): Converts to 1/8NPT female
91081 (connector for -P1 model): Converts to 1/4NPT female
91082 (connector for -P2 model): Converts to 1/8NPT female
1. Wrap seal tape around the threads of the tube.
2. Using two spanners, firmly attach the tubing connector to the pressure input port of the
instrument.
Cleaning
CAUTION
• When you clean the CA700 using a cleaning unit, be sure not to reverse the IN and OUT
connections. A reverse connection may damage the sensor inside the CA700.
• Use the output port (OUT) in the vent-open condition.
• Use the cleaning unit only for cleaning purposes.
French
ATTENTION
• Lors du nettoyage du CA700 à l’aide d’une unité de nettoyage, veiller à ne pas inverser
les connexions d’entrée et de sortie. Un raccordement inversé risque d’endommager le
capteur intégré au CA700.
• Utiliser le port de sortie (OUT) à l’état évent ouvert.
• Utiliser l’unité de nettoyage uniquement à des fins de nettoyage.
After measuring the liquid pressure, use the optional cleaning unit accessory to clean the internal
pressure sensor of the instrument.
91040: Cleaning unit Rc1/8 female thread (IN, OUT) for both -P1 and -P2
91041: Cleaning unit 1/8NPT female thread (IN, OUT) for both -P1 and -P2
IN
OUT
CA700
Pressure input port
Cleaning unit
1. Connect a cleaning unit to the CA700 pressure input port by tightening the connection by hand.
2. Apply dry cleaning air into the cleaning unit’s input port (IN).
The maximum input pressure is 500 kPa.
2.4 Connecting Source and Measurement Leads
Connecting the External Pressure Seneor
WARNING
• Use the external pressure sensor correctly, following its operation manual. Improper use of
the external pressure sensor causes considerable danger because high pressure is applied
to it.
• Use only the pressure sensor specialized for the CA700.
French
AVERTISSEMENT
• Utilisez le capteur de pression externe correctement, en suivant son mode d’emploi.
L’utilisation incorrecte du capteur de pression externe entraîne un danger considérable car
une pression élevée est appliquée.
• Utilisez uniquement le capteur de pression spécialisé pour le CA700.
With the CA700 powered off, use the connection cable included with the external pressure sensor to
connect the external pressure sensor input terminal of the CA700 to the CA700 connection terminal of
the sensor.
Pressure transmitter
Pressure pump
(hand pump etc.)
CA700
External pressure sensor
External pressure sensor input terminal
Power on the CA700. When the external pressure sensor is recognized successfully, the icon
indicating that sensor appears on the screen of the CA700.
Note
• Be sure to power off the CA700 and then connect the external pressure sensor.
• The external pressure sensor is available in the following firmware versions of the CA700.
PM100-*-05 (16 MPa model): 1.10 or later
PM100-*-06 (70 MPa model): 1.20 or later
You can download the latest firmware version from our website.
• If you reconnect to an external pressure sensor with a different pressure range while the power of this
instrument is on, a message is displayed and this instrument is restarted.
2.4 Connecting Source and Measurement Leads
Making Preparations for Measurements
2-13
IM CA700-02EN
1
2
3
4
5
6
App
Index
Hysteresis Warning
If the external pressure sensor receives the pressure exceeding its limit value, this may affect
measurement for a while even when the pressure falls below the limit value.
In the CA700, if the pressure input to the external pressure sensor exceeds the limit value, HYS
appears on the screen.
Even when the pressure falls below the limit value, HYS continues to appear for a period of time. This
period depends on the range and input pressure. Wait for HYS to disappear, and then use the external
pressure sensor.
Period when HYS is displayed
PM100-*-05 (16 MPa model)
Range
Limit value
8.4 MPa
12.0 MPa
19.2 MPa
7 MPa
approx 110 second
approx 340 second
approx 450 second
10 MPa
-
approx 150 second
approx 220 second
16 MPa
-
-
approx 50 second
PM100-*-06 (70 MPa model)
Range
Limit value
30 MPa
60 MPa
77 MPa
25 MPa
approx 150 second
approx 380 second
approx 510 second
50 MPa
-
approx 130 second
approx 220 second
70 MPa
-
-
approx 60 second
Hysterisis warning
Note
Even when the CA700 is powered on or off within the above period, the hysteresis warning state remains
unchanged within the period(HYS is displayed).
2.4 Connecting Source and Measurement Leads
Setting the Date and Time
Procedure
1. Turn on the CA700. The top menu appears.
2. Select Device Setting, and press ENTER. The Device Setting menu appears.
3. Select Device Setting, and press ENTER.
4. Hold down the ▲ or ▼ key until the second page of the Device Setting menu appears.
ENTER
ENTER
Set the date display format.
Set the date.
Set the time.
Confirms the settings
Setting the Date Display Format
5. Select Date Format, and press ENTER. A list of date display formats appears.
6. Select the format you want, and press ENTER.
ENTER
Setting the Date
7. Select Date, and press ENTER. The date appears highlighted.
8. Press the
or
key to move to the location you want to change, press the ▲ or ▼ key to set
the number, and press ENTER.
ENTER
to move the position
to change the value
Making Preparations for Measurements
Changing the Time
9. Select Time, and press ENTER. The time appears highlighted.
10. Press the
or
key to move to the location you want to change, press the ▲ or ▼ key to set
the number, and press ENTER.
Confirming the Changes
11. Press Setting Done (F5) on the function menu. The settings are confirmed, and the display
returns to the previous menu.
Explanation
Date and Time Display Format
The display format symbols are explained below.
YYYY: Year (Gregorian)
MM:
Month
DD:
Day
2-15
IM CA700-02EN
1
2
3
4
5
6
App
Index
2.5 Setting the Date and Time
Performing Zero Calibration
Procedure
1. Maintain the CA700 in an orientation for measuring pressure, and open the input.
When the pressure measurement display is showing, press ZERO.
A message appears for you to confirm the execution of the zero calibration.
2. Press ENTER. Zero calibration is executed.
To cancel zero calibration, press ESC.
Explanation
Zero calibration refers to the act of correcting the influence caused by changes in the temperature and
installation environment in order to perform highly accurate pressure measurements.
Be sure to perform zero calibration before making measurements.
To use the external pressure sensor, you also need to perform zero calibration of the sensor. For the
zero calibration of the external pressure sensor, see the manual of the sensor.
If the environmental conditions change while you perform continuous measurements, occasionally
perform zero calibration.
Note
• Zero calibration is effective even if you change the unit of pressure.
• Perform zero calibration after warm-up.
• For liquid measurements, fill the pipe and the instrument (measurement system) with liquid first, and then
perform zero calibration.
• Every time you change the orientation of the CA700, perform zero calibration.
• If it is necessary to match the pressure reference with a gauge, such as a pressure balance whose
pressure reference position is clear, align it with the reference point of the pressure receiving section as
shown below before starting zero calibration.
38
Reference point of the
pressure receiving section
96
Measurement Orientation
To measure pressure, install the instrument horizontally with the front panel facing up or tilted using
the rear panel stand. If you change the orientation of the CA700 when the measurement display is
showing, the “ZERO CAL” indicator will blink in the display. If this happens, be sure to perform zero
calibration.
2-16
IM CA700-02EN
Calibrating the Pressure Transmitter
3-1
IM CA700-02EN
1
2
3
4
5
6
App
Index
3.1
Connecting to the Pressure Transmitter
This section provides an example of how to calibrate a pressure transmitter that outputs the measured
pressure as current. Loop voltage is applied during calibration.
WARNING
• Do not apply pressure exceeding the allowable input range. Excessive pressure may cause
injury or damage to the instrument.
Model
CA700-*-01
CA700-*-02
CA700-*-03
Allowable input
Negative pressure
2.7 kPa abs
2.7 kPa abs
2.7 kPa abs
Positive pressure
500 kPa
3000 kPa
4500 kPa
• Before applying pressure to the instrument, make sure that tubing is connected properly.
Improper connection may cause gas or liquid to leak, which may in turn cause injury or
damage to the instrument.
• After use, be sure to depressurize adequately so that compressed gas or liquid does not
burst out. Then remove tubing.
CAUTION
• When joining the connector, using a spanner only on the connector side may break the
inside of the instrument. Be sure to use another spanner on the cut-out of the input port to
tighten the connector.
French
AVERTISSEMENT
• Ne pas appliquer de pression supérieure à la plage d’entrée autorisée. Une pression
excessive risquerait de provoquer des blessures ou d’endommager l’instrument.
Modèle
CA700-*-01
CA700-*-02
CA700-*-03
Entrée autorisée Pression négative
2,7 kPa abs
2,7 kPa abs
2,7 kPa abs
Pression positive
500 kPa
3000 kPa
4500 kPa
• Avant de mettre l’instrument sous pression, s’assurer que les tubes sont correctement
connectés. Une connexion incorrecte peut provoquer une fuite de gaz ou de liquide, ce qui
à son tour peut être à l’origine de blessures ou d’un endommagement de l’instrument.
• Après utilisation, veiller à effectuer une dépressurisation correcte, de façon à éviter que le
gaz ou le liquide comprimé ne jaillisse hors de l’instrument. Retirer ensuite les tubes.
ATTENTION
L’utilisation d’une clé uniquement sur le côté connecteur lors du raccordement du connecteur
risque de casser l’intérieur de l’instrument. Pour serrer le connecteur, veiller à utiliser une
autre clé sur la découpe du port d’entrée.
Chapter 3
Calibrating the Pressure Transmitter
Connecting to the Pressure Transmitter to the CA700
Connect the pressure pump output to the transmitter input and the CA700 input through branching.
Some pressure pumps have two output ports: one for applying pressure and another for the pressure
meter.
Connect the electrical output of the pressure transmitter to the signal terminal of the CA700. Connect
the H side of the pressure transmitter to the SOURCE mA/V terminal of the CA700 and the L side to
the MEASURE mA terminal.
You can also use the external pressure sensor to calibrate a high-pressure pressure transmitter. For
the connecting procedure, see section 2.4.
Pressure transmitter
Pressure pump
(91051/91056 etc.)
CA700
Input terminal
H
L
Red
Black
3.1 Connecting to the Pressure Transmitter
Calibrating the Pressure Transmitter
3-3
IM CA700-02EN
1
2
3
4
5
6
App
Index
3.2
Setting the Device Information and the
Calibration Conditions of the Pressure
Transmitter
Procedure
1. From the top menu, use the ▲ or ▼ key to select Calibrate, and press ENTER.
The calibration display appears.
2. Press Select Proc. (F2).
A list of registered calibration procedures is displayed.
The table lists tag numbers (first 20 characters of each one) and model numbers (first 15 characters of
each one).
Up to 20 sets of procedures can be registered. They are displayed in four windows.
3. Press
or
to change the page and ▲ or ▼ to select the calibration procedure you want to
edit. Press ENTER.
Information of the selected calibration procedure is displayed.
4. Press Edit (F1).
The calibration procedure setup screen appears. The setup screen is divided into three pages: Transmitter
Information, Measure, and Source.
Hold down ▲ or ▼ to change the screen.
Setting the Device Information of the Calibration Target
Entering the Model Number (Model No.)
5. Use the ▲ or ▼ key to select Model No., and press ENTER.
A character input screen appears.
Moves the input
position
Backspace
Confirms the input
Switching the display from
uppercase letters + numbers input to
lowercase letters + symbols input
Input position
Selected character ( to move, ENTER to enter)
6. Press (F1) or (F2) to move the input position, press
,
, ▲, or ▼ to select a character,
and press ENTER to enter the selected character.
7. After entering the characters, press Done (F5).
Entering the Tag No. and Serial No.
8. Use the ▲ or ▼ key to select Tag No. or Serial No., and press ENTER.
9. Like the model number, enter the tag number and serial number.
Setting Other Items or Confirming the Settings
10. To set measurement conditions and source conditions in addition to product information, press
▲ or ▼ key repeatedly until the screen changes. When the measurement condition or source
condition setup screen appears, continue with the procedure on the following pages.
To finish changing the settings, press Setting Done (F5). The settings are confirmed.
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Calibrating the Pressure Transmitter
3-5
IM CA700-02EN
1
2
3
4
5
6
App
Index
Setting Measurement Conditions
Setting Measurement Features
5. In the calibration procedure setting display, hold down the ▲ or ▼ key.
The display switches to page 2/3 (measurement condition setting display).
6. Set the calibration target output.
Use the ▲ or ▼ key to select Function, and press ENTER.
The measurement feature options are displayed.
7. Use the ▲ or ▼ key to select mA LOOP, and press ENTER.
ENTER
ENTER
Turns averaging on and off
Turns scaling on and off
Set the 0% value.
Set the 100% value.
Tolerance for pass/fail judgment
Confirms the settings
Set the unit
Setting Averaging and Scaling
Set averaging and scaling if necessary.
Here, we will set them to OFF.
8. Use the ▲ or ▼ key to select Averaging, and press ENTER.
9. Press OFF (F2).
10. Turn scaling off.
To use scaling, select ON, and press ENTER. A scaling setting menu appears.
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Setting the 0% Value and 100% Value
For the pressure transmitter output that the CA700 will measure, select the range to calibrate.
11. Use the ▲ or ▼ key to select 0% Value, and press ENTER.
12. Press the
or
key to move to the digit you want to change, press the ▲ or ▼ key to set the
number.
To confirm the value, press ENTER.
Likewise, set the 100% value.
ENTER
ENTER
Setting the Tolerance for Pass/Fail Judgment
13. Use the ▲ or ▼ key to select Tolerance, and press ENTER.
14. Press the
or
key to move to the digit you want to change, press the ▲ or ▼ key to set the
number.
To confirm the value, press ENTER.
The values assigned to 0% and 100% will be used as references.
Setting Other Item or Confirming
15. To set items in addition to measurement conditions, press ▲ or ▼ key repeatedly until the
screen changes.
To finish changing the settings, press Setting Done (F5). The settings are confirmed.
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Calibrating the Pressure Transmitter
3-7
IM CA700-02EN
1
2
3
4
5
6
App
Index
Setting Source Conditions
5. In the calibration procedure setting display, hold down the ▲ or ▼ key.
The display switches to page 2/2 (source condition setting display).
Page 3/3
Setting the Source Feature
Here, we will set the source feature to P.
If you change the source feature to anything other than pressure (P or EXT P) here, the measurement
feature setting will change.
6. Use the ▲ or ▼ key to select Function, and press ENTER.
The source function options are displayed.
7. Use the ▲ or ▼ key to select P, and press ENTER.
The source function set.
Note
• Even if you set the source feature to pressure (P or EXT P), the CA700 will not produce pressure. The
CA700 will measure and display the pressure applied to the pressure transmitter.
• If the measurement feature is set to mA Loop when the source feature is set to anything other than
pressure (P or EXT P), the source feature is automatically set to pressure (P).
Setting the Unit
8. Use the ▲ or ▼ key to select Unit, and press ENTER.
The pressure unit options are displayed.
9. Use the ▲ or ▼ key to select a unit, and press ENTER.
The unit is set.
ENTER
ENTER
Setting Averaging and Scaling
The pressure transmitter input pressure can be averaged or scaled before it is displayed on the
CA700. Here, we will set both of them to OFF.
10. Use the ▲ or ▼ key to select Averaging, and press ENTER.
11. Press OFF (F2).
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
12. Turn scaling off.
To use scaling, select ON, and press ENTER. A scaling setting menu appears.
Setting the 0% Value and 100% Value
Set the pressure transmitter input pressure that correspond to the output current calibration range (0%
and 100%) of the pressure transmitter, which was set in steps 5 and 6.
13. Use the ▲ or ▼ key to select 0% Value, and press ENTER.
14. Press the
or
key to move to the digit you want to change, press the ▲ or ▼ key to set the
number.
To confirm the value, press ENTER.
Likewise, set the 100% value.
ENTER
ENTER
Setting the Number of Calibration Points (Number Of Points)
15. Use the ▲ or ▼ key to select Number Of Points, and press ENTER.
16. Press the
or
key to move to the digit you want to change, press the ▲ or ▼ key to set the
number.
To confirm the value, press ENTER.
The range is 1 to 10.
ENTER
ENTER
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Calibrating the Pressure Transmitter
3-9
IM CA700-02EN
1
2
3
4
5
6
App
Index
Setting the Calibration Direction (Direction)
Set the calibration direction.
17. Press the ▲ or ▼ key to select Direction.
The options appear on the function menu.
0% to 100%
100% to 0%
0% to 100% to 0%
18. Press Up (F1), Down (F2), or Up/Down (F3).
If you select Up/Down, the number of calibration points will be set to (the number of points set
in step 16)x2 – 1.
Confirming the Settings
19. After entering the information, press Setting Done (F5). The settings are confirmed.
Press ESC to return the display.
Explanation
Calibration Procedure
You can register up to twenty sets of calibration processes. A calibration procedure consists of a set of
device information, measurement feature and source feature.
To calibrate a pressure device, select one of the registered processes to perform calibration.
Device Information
The device information that you set here is saved to a file along with the calibration data. This is
convenient in associating the saved data with the device.
Input Characters
The number of characters that you can enter is as follows.
Model No.: Up to 20 alphanumeric characters
Tag No.:
Up to 32 alphanumeric characters
Serial No.: Up to 15 alphanumeric characters
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Measurement Feature and Source Feature
The measurement feature measures the output from the calibration target, and the source feature
outputs the input to the calibration target. If you set the source feature to pressure, the CA700 only
monitors the input to the calibration target.
The combinations of the measurement feature and source feature are as follows.
Measurement Feature
Source Feature
Pressure (P)
Pressure (external pressure
sensor, EXT P)
DC current (mA SOURCE)
Simulation (mA SIMULATE)
DC voltage (V SOURCE)
Pressure switch (P SWITCH)
Pressure switch (external pressure
sensor, EXT SWITCH)
—
DC current (mA MEASURE)
Pressure (P)
Pressure (external pressure
sensor, EXT P)
Loop current (mA LOOP)
DC voltage (V MEASURE)
When EXT P or EXT SWITCH (for only measurement functions) using the external pressure sensor is
set for the measurement and source functions, set the type (Sensor Type) and range (Range) of the
sensor. For details, see the User’s Manual IM CA700-01JP contained in the CD-ROM.
Unit (Pressure)
You can select from mbar, bar, Pa, hPa, kPa, MPa, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4°C,
mmH2O@20°C, ftH2O@4°C, ftH2O@20°C, inH2O@4°C, inH2O@20°C, Torr, psi.
Averaging
The CA700 displays moving average results.
Scaling
The CA700 displays linearly scaled results. You can assign a unit appropriate for the values after
scaling.
The scaling method is the same as pressure measurement. See section 2.1.
0% Value and 100% Value
Set the 0% and 100% of the calibration range in terms of the calibration target input and output (which
corresponds to the input).
Calibration target input (source feature)
Calibration target output (measurement feature)
0%
100%
0%
100%
Tolerance for Pass/Fail Judgment
Set the tolerance for making pass/fail judgments on calibration results. The tolerance is set in
reference to the 0% and 100% values described above.
Tolerance = ±((100% value of the measurement feature – 0% value of the measurement
feature)×tolerance setting/100)
For example, when the calibration target output is 4 mA to 20 mA and this range is assigned to 0 to
100%, if the tolerance range is set to 0.02%, the tolerance is given by
±(20 mA – 4 mA)×0.02/100 = ±0.0032 mA.
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Calibrating the Pressure Transmitter
3-11
IM CA700-02EN
1
2
3
4
5
6
App
Index
Number of Calibration Points (Number Of Points)
Set the number of measurement points between 0% to 100%.
The range is 1 to 10. If you specify 1, the calibration is performed at 0% if the calibration direction
(Direction) is set to Up or Up/Down and 100% if set to Down. If you specify a number between 2 and
10, the calibration is performed for the number of specified points. This includes calibration at 0% and
100%.
The calibration points are at equally divided points between 0% and 100%. For example, if the number
of calibration points is set to 5, the calibration points are 0%, 25%, 50%, 75%, and 100%.
Calibration Direction (Direction)
Set whether to calibrate from 0% (Up), from 100% (Down), or from 0% to 100% back down to 0%.
Up:
0% to 100%
Down:
100% to 0%
Up/Down:
0% to 100% to 0%
If the calibration direction is Up/Down, the number of calibration points is given by
Number of calibration points = (Number Of Points setting)x2 – 1.
For example, if the number of calibration points is set to 5, the calibration points are 0%, 25%, 50%,
75%, 100%, 75%, 50%, 25%, and 0% (total of 9 points).
3.2 Setting the Device Information and the Calibration Conditions of the Pressure Transmitter
Calibrating the Pressure Transmitter
Procedure
Selecting the Calibration Procedure
1. In the calibration display, press Select Proc. (F2).
The calibration procedure setting display appears.
An asterisk is displayed next to the selected calibration procedure.
2. Use the ▲ or ▼ key to select a calibration procedure,and press ENTER. Here, select the
calibration procedure whose Source is pressure (P) and Measure is mA Loop, as set in section
3.2.
The calibration procedure is selected, and the calibration display returns.
ENTER
The information of the selected
calibration procedure appears.
Saving Calibration Data at Calibration Points
3. Press As Found (F3).
The display switches to the source and measure value display.
Pressure transmitter output
(loop current)
Pressure transmitter input
(pressure)
Calibration point (current calibration
point/total number of calibration points)
Pressure transmitter input value at the calibration point
Error in the pressure transmitter output
Calibrating the Pressure Transmitter
3-13
IM CA700-02EN
1
2
3
4
5
6
App
Index
4. Press Loop On (F4). The CA700 outputs a 24 VDC loop voltage and measures the loop
current.
5. From the pressure pump, apply the pressure for the adjustment point. The pressure pump
output is displayed on the CA700. Here, apply a pressure of 50.000 kPa.
6. Press Set Point (F1). The pressure and loop current applied to the pressure transmitter are
saved.
The F2 key shows Next Point.
7. Press Next Point (F2).
The pressure transmitter input value, output value, and output error are saved.
The CA700 proceeds to the next calibration point.
8. Repeat 4 to 6 for all the calibration points.
When you save the data for the last calibration data, the F5 key shows Done.
9. Press Done (F5).
The calibration data of all calibration points are saved to a single CSV file, and the calibration result is
shown on the display.
10. Press Done (F5).
The calibration display of step 1 appears.
3.3 Calibrating the Pressure Transmitter
Adjusting the Pressure Transmitter
11. In the calibration display, press Adjust (F4).
A display for monitoring the pressure transmitter output appears.
Pressure transmitter output
(loop current)
Pressure transmitter input
(pressure)
Pressure transmitter input value at the adjustment point
Error in the pressure transmitter output
12. Press Span100% (0%) (F1), Step Up (F2), and Step Down (F3) to set the adjustment point.
The adjustment points are the same as the calibration points.
Here, we will adjust the 0% point.
13. Press Loop On (F4). The CA700 outputs a 24 VDC loop voltage and measures the loop
current.
14. From the pressure pump, apply the pressure for the adjustment point (50 kPa here). The
pressure pump output is displayed on the CA700.
The pressure transmitter output is displayed on the CA700.
15. Adjust the pressure transmitter so that the loop current value displayed on the CA700 is within
the tolerance.
Adjust so that the pressure transmitter output error
is within the tolerance.
Pressure transmitter output current
corresponding to 50 kPa pressure
Pressure at adjustment point 0%
16. Press Span100% (0%) (F1), Step Up (F2), and Step Down (F3) to change the adjustment
point, and repeat steps 13 to 15.
17. When you finish adjusting all adjustment points, press Adjust Done (F5) or ESC.
The calibration display returns.
Saving the Calibration Data after Adjustment
18. In the calibration display, press As Left (F5).
The display switches to the source and measure value display.
19. Using the same procedure as in “Saving Calibration Data at Calibration Points,” save the
calibration data after adjustment.
20. When you finish saving the data of all calibration points, press Done (F5).
The calibration data of all calibration points are saved to a single CSV file, and the calibration result is
shown on the display.
3.3 Calibrating the Pressure Transmitter
Calibrating the Pressure Transmitter
3-15
IM CA700-02EN
1
2
3
4
5
6
App
Index
Explanation
Calibration Data File
The pressure transmitter calibration data before and after adjustment is saved to CSV files.
File Name
Calibration data before adjustment: MSxxF_y.CSV
Calibration data after adjustment:
MAxxL_y.CSV
xx:
00 to 99 (calibration group number)
Same number between the calibration data file before and
after adjustment
y:
0 to 9 Sequence number for calibration data files before
adjustment or after adjustment
Because the number xx is the same for calibration data files before and after adjustment, the
association is maintained.
If you change the device information or calibration procedure, the number xx is incremented.
Note
• If there are gaps in the calibration group numbers due to the deletion of files and the like, precedence is
given to the missing numbers.
• If all the calibration group numbers or file sequence numbers are used up, an error will appear. Copy the
necessary files to another location, and delete them.
Data That Is Saved
Calibration conditions, device information, date and time of calibration, pressure transmitter input
(source) value at each calibration point, pressure transmitter output (measure) value, error (%), and
judgment result are saved.
Judgment Result
If the pressure transmitter output value is within the tolerance set in section 3.3, PASS is displayed and
saved. Otherwise, FAIL is saved.
Data Example
MODEL CA700
FILE TYPE
3
FUNCTION
SOURCE P
MEASURE mA LOOP
UNITS kPa
mA
AVERAGING
0
0
SCALING
0
0
SCALING UNITS
RANGE 0% VALUE
50
5
RANGE 100% VALUE 150
20
TOLERANCE 0.5
NUMBER OF POINTS 4
DIRECTION
UP
MODEL No.
********
TAG No.
********
SERIAL No.
********
CALIBRATION DATE
2013/6/6
CALIBRATOR SERIAL No. 91N512849
CALIBRATOR CALIBRATION DATE 2012/2/15
EXTERNAL SENSOR MODEL NO. PM100-J-05-P3
EXTERNAL SENSOR SERIAL NO. 91T000000
EXTERNAL SENSOR CALIBRATION DATE 2013/4/27
No.
DATE
TIME
SOURCE/MONITOR (Pa)
MEASURE (A)
ERROR%
PASS/FAIL
1
2013/6/6
13:31:50
5.00E+04
5.00E-03
2.00E-02
PASS
2
2013/6/6
13:32:16
8033E+04
1.00E-02
4.00E-02
PASS
3
2013/6/6
13:33:34
1.17E+05
1.50E-02
6.00E-02
PASS
4
2013/6/6
13:33:51
1.50E+05
2.00E-02
8.00E-02
PASS
3.3 Calibrating the Pressure Transmitter
Troubleshooting, Maintenance, and Inspection
4.1
If a Problem Occurs
Faults and Corrective Actions
If servicing is necessary, or if the instrument does not operate properly even after you have attempted
to deal with the problem according to the instructions in this section, contact your nearest YOKOGAWA
dealer.
Problems and Solutions
Refer to
Section
The CA700 does not turn on.
Check that the remaining battery power is sufficient.
2.3
Check that the batteries are inserted correctly.
2.3
The power turns off.
Check that there is sufficient remaining battery power.
2.3
The display is dark.
Adjust the contrast.
—1
Press the backlight key to turn on the backlight.
1.1
The display is odd.
Confirm that the ambient temperature and humidity are within their specified ranges.
2.2
Confirm that the display is not being affected by noise.
2.1
Make sure that the measurement leads are properly connected.
2.4
Restart the CA700.
2.3
Keys do not work.
Press HOLD to release the display hold mode.
1.1
The measured or source value is odd.
Check that the remaining battery power is sufficient.
2.3
Check that the “Function” is set properly.
—2
Check that the source and loop power supply are on.
3.3
Check that connections are correct.
2.4
Confirm that the ambient temperature and humidity are within their specified ranges.
2.2
Allow the instrument to warm up for at least 30 minutes after turning on the power.
2.3
USB devices or the CA700 does not operate properly.
If you turned the CA700 on with USB devices connected to the USB ports for peripherals, turn
the CA700 off, remove the USB devices, turn the CA700 back on, and then connect the USB
devices. After turning off the power, wait at least 10 seconds before you turn it back on.
2.3
Unable to configure or control the instrument through the communication interface.
Check the address settings.
—3
Match the address used in the program to the CA700 address.
Confirm that the interface meets the electrical and mechanical specifications.
1 See section 6.1 in IM CA700-01EN, which is included in the accompanying CD.
2 See chapter 2 in IM CA700-01EN, which is included in the accompanying CD.
3 See chapter 5 in IM CA700-01EN, which is included in the accompanying CD.
Chapter 4
Troubleshooting, Maintenance, and Inspection
Error Codes, Error Messages, and Actions
Number
Error description
Cause of Error
Corrective Action
0
No error
—
—
11
Command error
An undefined command was received
(USB communication).
Check the command.*
12
Parameter error
Command parameter designation is
incorrect (USB communication).
Check the command.*
13
Execution error
A command that cannot be executed
in the current condition was received
(USB communication).
Check the command.*
16
Adjustment error
An error was detected during
adjustment.
Servicing is required.
17
Zero calibration error
Zero calibration error.
Check the installation orientation of
the CA700.
20
Source error
24 V LOOP measurement power
supply error
Check the connection.
23
Source error
Excessive current or voltage was
detected in the source output.
Check the connection.
24
Source error
Insufficient current supply
Replace the batteries.
33
Storage error
The data storage destination is full.
Data cannot be saved.
Check the save destination.
34
Storage error
Data cannot be saved due to some
error occurring at the data storage
destination.
Check the save destination.
50
Measurement error
Pressure sensor error
Servicing is required.
51
Measurement error
Tilt sensor error
Servicing is required.
52
Measurement error
A/D converter error
Servicing is required.
* See the communication commands (section 5.3) in IM CA700-01EN, which is included in the
accompanying CD.
Error message
Symptom
Action
A communication error of the
external pressure sensor.
Reconnect the sensor.
A communication to the PM100
cannot be established
• Check the external pressure sensor icon
• Reconnect the PM100
• Power on the main unit again
• Replace the connection cable
If the error cannot be resolved, a service is
required.
A memory error of the external
pressure sensor.
Reconnect the sensor.
The memory inside the PM100 is
faulty
• Reconnect the PM100
• Power on the main unit again
If the error cannot be resolved, a service is
required.
A measurement error of the
external pressure sensor.
Reconnect the sensor.
Pressure cannot be measured
correctly
• Reconnect the PM100
• Power on the main unit again
If the error cannot be resolved, a service is
required.
The external sensor has been
changed.
Reboot the device.
Changed to an external pressure
sensor with a different range while
the instrument was on.
Press ESC or ENTER, and then restart the
instrument.
The measured pressure value is
“------”
· The connection cable of the
PM100 is not connected properly
· The PM100 is faulty
• Check the external pressure sensor icon
• Reconnect the PM100
• Power on the main unit again
If the error cannot be resolved, a service is
required.
Troubleshooting, Maintenance, and Inspection
4.3
Viewing System Information (Overview)
Procedure
1. Turn on the CA700. The top menu appears.
2. Select Device Setting, and press ENTER. The Device Setting menu appears.
3. Select Device Information, and press ENTER.
ENTER
+ENTER
CA700 serial number
Date when the CA700 was calibrated at the factory
Firmware version
Internal pressure sensor firmware version
Firmware version of the external pressure sensor
Model number of the external pressure sensor
Serial number of the external pressure sensor
Calibration date of the external pressure sensor
The following information is displayed:
• Serial number of the CA700 main unit
• Calibration date of the CA700 main unit
• Firmware version of the CA700 main unit
• Firmware version of the internal pressure sensor
• Firmware version of the external pressure sensor (when it is connected)
• Model name of the external pressure sensor (when it is connected)
• Serial number of the external pressure sensor (when it is connected)
• Calibration date of the external pressure sensor (when it is connected)
The calibration dates of the CA700 main unit and external pressure sensor are displayed differently
depending on a calibration state.
Calibration Date: Date when we perform calibration (it is also displayed on delivery)
Calibration Date(User): Calibration date written with the communication command
Inspection Date: Delivery and inspection date (it is displayed when the firmware version is
upgraded with no calibration since the delivery. After the calibration, the date
returns to Calibration Date.)
4.3 Viewing System Information (Overview)
Troubleshooting, Maintenance, and Inspection
4.4
Recommended Part Replacement and
Calibration
Recommended Part Replacement and Consumable Parts
The following are consumable parts. We recommend replacing them at the following intervals. For part
replacement, contact your nearest YOKOGAWA dealer.
Part Name
Recommended Replacement Interval
Backup battery (lithium battery)
5 years
Calibration
To ensure accurate measurement, we recommend periodic calibration.
Recommended calibration period: 1 year
Note
For details on calibrating the measurement and source features of the DC voltage and DC current, see the
separate manual (IM CA700-01EN, included in the accompanying CD).
Disposing of the Instrument
When disposing of the instrument, follow the laws and ordinances of your country or region.
Pressure Measurement Feature
Pressure Measurement Range*
Suffix Code
-01
02
-03
Pressure type
Gauge pressure
Measurement range
Positive pressure 0 to 200 kPa
Negative pressure –80 to 0 kPa
Positive pressure 0 to 1000 kPa
Negative pressure –80 to 0 kPa
Positive pressure 0 to 3500 kPa
Negative pressure –80 to 0 kPa
Measurement display range Up to 240.000 kPa
Up to 1200.00 kPa
Up to 4200.00 kPa
Measurement accuracy
(6 months)
after zero calibration1, 2
Positive pressure
20 to 200 kPa: ±(0.01% of
reading + 0.003 kPa)
0 to 20 kPa: ±0.005 kPa
Positive pressure
±(0.01% of reading + 0.04 kPa)
Positive pressure
±(0.01% of reading + 0.15 kPa)
Negative pressure
±(0.2% of reading + 0.080 kPa)
Negative pressure
±(0.2% of reading + 0.08 kPa)
Negative pressure
±(0.2% of reading + 0.08 kPa)
Measurement accuracy
(1 year)
after zero calibration1, 2
Positive pressure
20 to 200 kPa:±(0.01% of
reading + 0.010 kPa)
0 to 20 kPa: ±0.012 kPa
Positive pressure
±(0.01% of reading + 0.08 kPa)
Positive pressure
±(0.01% of reading + 0.30 kPa)
Negative pressure
±(0.2% of reading + 0.090 kPa)
Negative pressure
±(0.2% of reading + 0.09 kPa)
Negative pressure
±(0.2% of reading + 0.09 kPa)
Resolution
0.001 kPa
0.01 kPa
0.01 kPa
Response time3
2.5 s or less
Allowable input
2.7 kPa abs to 500 kPa gauge
2.7 kPa abs to 3000 kPa gauge 2.7 kPa abs to 4500 kPa gauge
Internal volume
Approx. 6 cm3
Temperature coefficient4
±(0.001% of reading + 0.001% of full scale)/°C or less
Influence of positional setup Zero point ± 0.3 kPa or less
Measured medium
Gas and liquid (non-corrosive, non-flammable, non-explosive, and non-toxic fluids)
Measured medium
temperature5
–10 to 50°C
Pressure sensor
Silicon resonant sensor
Pressure sensing element
Diaphragm
Pressure unit display
kPa and other units (Pa, hPa, MPa, mbar, bar, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4°C,
mmH2O@20°C, ftH2O@4°C, ftH2O@20°C,inH2O@4°C, inH2O@20°C, torr, psi)
Input port
Rc 1/4 or 1/4 NPT female thread (selectable)
Measurement unit material
Diaphragm: Hastelloy C276, Input port: SUS316
*
23°C ± 3°C
1
Zero-point calibration condition: Under atmospheric pressure
2
Yokogawa’s pressure standards accuracy is excluded.
3
Conditions of response time measurement:
The response time is defined as the time for the readout to settle within ±1% of the full scale from the
time when the positive pressure is released to atmosphere when it is at its full-scale value
(where the input unit is under no load).
4
Full scale of each model
CA700-E-01: Positive pressure 200 kPa and negative pressure 80 kPa
CA700-E-02: Positive pressure 1000 kPa and negative pressure 80 kPa
CA700-E-03: Positive pressure 3500 kPa and negative pressure 80 kPa
5
Liquid temperature 5 to 50°C
Pressure switch test
Holds the pressure valued at the time the port switches between open and close.
Measures the resistance between ports when they are closed (measurement current < 1 mA)
Resistance measurement range
0 to 2.000 kΩ
Tilt Alarm
The zero adjustment indicator blinks when the orientation of the CA700 changes by approximately
10 degrees or more after the previous zero adjustment.
If the external pressure sensor selected as a function changes in position of about 10 degrees or
more after zero adjustment, the zero adjustment indication blinks.
Chapter 5
Specifications
DC Current and DC Voltage Source Features
Item
Specifications (23°C ± 3°C, one year
after calibration)
Notes
Current 20 mA range
SOURCE
0 to 20.000 mA
Compliance voltage 24 V (when HART resistance
is OFF), 18 V (when HART resistance is ON)
The maximum setting is range×1.2.
Accuracy
0.015% of setting + 3 μA
20 mA range
SIMULATE
0 to 20.000 mA
External power supply 5 to 28 V (when HART
resistance is OFF)
External power supply 12 to 28 V (when HART
resistance is ON)
The maximum setting is range×1.2.
Accuracy
0.015% of setting + 3 μA
Voltage 5 V
0 to 5.0000 V
The maximum setting is range×1.1.
Load current 1 mA max. (load resistance ≥ 5 kΩ)
Accuracy
0.015% of setting + 0.5 mV
Temperature coefficient
Add accuracy×(1/10)/°C
–10 to 20°C, 26°C to 50°C
Source load condition
C ≤ 0.1 μF
L ≤ 10 mH
Source voltage to ground
42 Vpeak
Voltage limiter
approx. 36 V
Current limiter
approx. 30 mA
Loop feature
Step and linear
5.3
DC Current and DC Voltage Measurement
Features
Item
Specifications (23°C ± 3°C, one year
after calibration)
Notes
Current
20 mA range
Measurement range 0 to ±20.000 mA
The maximum display value is
range×1.2.
Internal impedance < 10 Ω
Resolution 1 μA
Accuracy 0.015% of reading + 3 μA
100mA range
Measurement range 0 to ±100.00 mA
The maximum display value is
range×1.2.
Internal impedance < 10 Ω
Resolution 10 μA
Accuracy 0.015% of reading + 30 μA
Voltage
5V range
Measurement range 0 to ±5.0000 V
The maximum display value is
range×1.1.
Internal impedance < 1 MΩ
Resolution 0.1 mV
Accuracy 0.015% of reading + 0.5 mV
50V range
Measurement range 0 to ±50.000 V
The maximum display value is
range×1.1.
Internal impedance < 1 MΩ
Resolution 1 mV
Accuracy 0.015% of reading + 5 mV
LOOP
Supply voltage
Supply current
24 V ± 1 V, 24 mA
HART resistance OFF,
short current < 35 mA
24 V ± 6 V, 20 mA
HART resistance ON,
short current < 35 mA
20 mA range
Measurement range 0 to 20.000 mA
The maximum display value is
range×1.2.
Resolution 1 μA
Accuracy 0.015% of reading + 3 μA
Temperature
coefficient
Add accuracy×(1/10)/°C
–10 to 20°C, 26°C to 50°C
CMRR:
Approx. 120 dB (50/60 Hz)
NMRR:
Approx. 60 dB (50/60 Hz)
Current terminal input protection:
PTC protection
Measurement terminal maximum input:
Voltage terminal 50 V DC
Current terminal 120 mA
Measurement unit voltage to ground:
50 Vpeak
Number of Saved Data Values
Instrument Operating Condition
Number of Data Values
That Can Be Saved
Number of Files That Can
Be Saved
Current
Save
2000
45
Logging
2000
45
Leakage test
2000
45
Transmitter calibration
(Number of calibration
points: 5)
As Found
9
250
As Left
9
250
Pressure switch calibration As Found
1
250
As Left
1
250
Total number of files: Up to 250
Total data size: Up to approx. 3.5 MB
General and Common Specifications
Item
Specifications
Standard
temperature
23°C ± 3°C, 20 to 80%RH (no condensation)
Function
Common
HOLD, Min/Max, RELATIVE, %span, scaling, alarm
Pressure
Zero calibration, unit change, pressure switch test, leak test (period: 00:00:01 to 24:00:00)
Source
Linear sweep and step sweep (15, 30, 45, 60 second intervals)
Internal HART communication resistor (250 Ω) ON/OFF
Memory
Manual memory (date/time, display 1, display 2)
Logging (2000 data points max. at 1, 2, 5, 10, 30, 60 s intervals)
Device information, date/time, display 1 value, display 2 value
Transmitter calibration data (As Found, As Left)
Device information, calibration procedure, date/time, source value, measured value, error,
and pass/fail
Pressure switch test (As Found, As Left)
Device information, date/time, open value, close value, deadband, resistance
Leakage test
Device information, start date/time and data, end date/time and data, deviation, leak rate
Display update rate
Approx. 300 ms (3 times per second)
Interface
Select and switch between USB A mass storage device, USB mini B Communication Device Class,
and Mass Storage Class
External sensor
Dedicated external sensor can be connected to the connector.
Display
Dot matrix LCD (320×240 dots)
Backlight
LED
Warm-up time
Approx. 5 minutes
Power supply
Six AA alkaline dry cells
Battery life
Alkaline batteries
24 V loop power supply off during current measurement approx. 35 h (communication resistance on)
24 V loop power supply on during current measurement approx. 10 h (communication resistance on,
supplying 10 mA loop current)
Auto power-off feature
Approx. 60 minutes; can be disabled
Insulation resistance
Between input terminal and case and between input port and case: At least 100 MΩ (500 VDC)
Withstand voltage
Between input terminal and case and between input port and case: 500 VAC for 1 minute
Protection level
IP54
External dimensions
Approx. 264 (W) × 188 (H) × 96 (D) (excluding protrusions)
Weight
Approx. 2 kg
Operating temperature and
humidity
–10 to 50°C, 20 to 80%RH (no condensation)
Storage temperature and
humidity
–20 to 60°C, 20 to 80%RH (no condensation)
Overvoltage Category I1
Pollution degree 22
EN61010-2-030
No measurement category; O (Other)3
Emissions*
Compliant standards
EN61326-1 class A
EN55011 class A, group 1
EMC standards of Australia and New Zealand EN55011 Class A, Group 1
Korea Electromagnetic Conformity Standard ( 한국 전자파적합성기준)
This product is a Class A (for industrial environment) product. Operation of this product in a
residential area may cause radio interference in which case the user will be required to correct the
interference.
Cable conditions
USB port (Function)
Use a shielded USB cable (3 m in length or less).
Measurement lead
Pass each measurement lead (L4059PR) three times through the supplied ferrite core to attach
it (see the figure below).
Attach the ferrite core as close as possible.
Immunity*
Compliant standards
EN61326-1 Table 2 (for industrial environments)
However, the measured values may receive noise effects.
Cable conditions
Same as the emission cable conditions.
Environmental standard*
Compliant standard
EN50581 Monitoring and control instruments including industrial monitoring and control instruments.
* Applies to products with CE marks. For information on products without CE marks, contact your nearest YOKOGAWA dealer.
1 The overvoltage category (installation category) is a value used to define the transient overvoltage condition and includes
the rated impulse withstand voltage. Overvoltage Category I applies to equipment that is connected to a circuit that has been
designed to suppress overvoltage caused by transient phenomena to an adequately low level.
2 Pollution Degree applies to the degree of adhesion of a solid, liquid, or gas that deteriorates withstand voltage or surface
resistivity. Pollution degree 2 applies to normal indoor atmospheres (with only non-conductive pollution).
3 The measurement category of the CA700 signal terminals is Other (O). Do not use it to measure the main power supply or for
Measurement Categories II, III, and IV.
Measurement category O (Other) applies to measurement of circuits that are not directly connected to a main power source.
This category applies to measurement of secondary electric circuits in equipment across a transformer. The estimated transient
overvoltage that may appear at the CA700 signal input is 350 V.
Measurement category II applies to measurement of circuits, such as household electric appliances and portable electric tools,
that are connected to low-voltage installations.
Measurement category III applies to measurement of facility circuits, such as distribution boards and circuit breakers.
Measurement category IV applies to measurement of power source circuits, such as entrance cables to buildings and cable
systems, for low-voltage installations.
5.5 General and Common Specifications
Unless otherwise specified, tolerances are ±3%
(however, tolerances are ±0.3 mm when below 10 mm).
nbn @ nbn. at | www. nbn. at
Tel. +43 316 40 28 05 | Fax +43 316 40 25 06
Riesstraße 146, 8010 Graz
nbn Austria GmbH
Aufgrund laufender Weiterentwicklungen sind Änderungen der Spezifikationen vorbehalten. Alle Angaben vorbehaltlich Satz- und Druckfehler.