Bulletin No. LPAX5-E Outside US: +1 (717) 767-6511 Drawing No. LP0489 www.redlion.net Revised 2018-06-28 -1- MODEL LPAX ‐ 5 DIGIT LARGE PAX DISPLAY FOR ANALOG INPUTS • LARGE LED DISPLAY READABLE TO 70 FEET • VARIOUS ANALOG INPUT MODULES: DC VOLTAGE AND CURRENT PROCESS SIGNALS TRUE RMS VOLTAGE AND CURRENT THERMOCOUPLE OR RTD STRAIN GAGE/BRIDGE • VARIOUS OUTPUT OPTION MODULES • CUSTOM UNITS LABEL WITH BACKLIGHT • PROGRAMMABLE USER INPUTS • PROGRAMMABLE FUNCTION KEYS • UNIVERSAL AC/DC POWERED • CRIMSON 2 PROGRAMMING SOFTWARE • NEMA 4X/IP65 GENERAL DESCRIPTION The LPAX Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is temperature, weight, or flow, the LPAX can satisfy your requirement. With the use of a units label and backlighting, the display can be tailored to show the actual engineering unit, which further enhances the display. This LPAX display accepts various analog inputs through the use of input modules (MPAX) which allow the unit to adapt to most any application. The MPAX Modules offer the same features as our highly successful PAX Series Panel Meters. Additional plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the LPAX a truly Intelligent Panel Meter. SAFETY SUMMARY CAUTION: Risk Of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system. SPECIFICATIONS Additional specifications, wiring, programming, and information for the individual MPAX models are contained in the corresponding standard PAX literature. 1. DISPLAY: 1.5" (38 mm) Red LED 5-Digit: (-19999 to 99999) 2. POWER REQUIREMENTS: AC Modules: 85 to 250 VAC, 50/60 Hz, 18 VA DC Modules: 11 to 36 VDC or 24 VAC ±10%, 50/60 Hz, 14 W 3. INPUT: Accepts analog input modules, see “Selecting Your Display Components.” 4. ANNUNCIATORS: LPAX0500: MAX, MIN, TOT, SP1, SP2, SP3, and SP4 Optional units label with backlight 5. KEYPAD: Five tactile membrane switches integrated into the front panel 6. CERTIFICATIONS AND COMPLIANCES: CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC/EN 61010-1 RoHS Compliant UL Listed: File #E179259 Type 4X Indoor / IP66 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) ELECTROMAGNETIC COMPATIBILITY EMC specifications determined by the MPAX module. 7. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: Determined by the MPAX module Storage Temperature Range: -40 to 60°C Operating and Storage Humidity: 0 to 85% max. RH (non-condensing) Altitude: Up to 2000 meters C US LISTED UL R PROC. CONT. EQ. E179259 SP1 SP2 SP3 SP4 SP1 SP2 SP3 SP4 DSP PAR RST F1 2 F 10.00 (254.0) 4.75 (120.7) 3.63 (92.2 ) 4.20 (106.7) .08 (2.0) 2X 4.725 (120.0) (236.0 ) .120 (3.05) 3.54 (89.9) 4.65 (118.1) .285 (7.2) +.03 -.00 -.00 +.76 9.29 -.00 +.04 -.00 +1.01 .234 (5.94) DIA. THRU, TYP. MAX MIN TOT DIMENSIONS In inches (mm) PANEL CUT-OUT

CAUTION: Disconnect all power

before installing or removing module. -2- Bulletin No. LPAX5-E Released 2018-06-28 Drawing No. LP0489 8. MOUNTING REQUIREMENTS: Max. panel thickness is 0.375" (9.5 mm) Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.52 mm) 9. MODULE INSTALLATION: 24-pin shrouded connector on LPAX engages connector on MPAX module upon installation. Shroud ensures proper alignment by providing a lead-in for the module connector. 10.CONNECTIONS: All wiring connections are made to the MPAX module via high compression cage-clamp terminal blocks. Wiring instructions are provided with the MPAX module. 11.CONSTRUCTION: Steel front panel, enclosure, and rear cover with textured black polyurethane paint for scratch and corrosion resistance protection. Sealed front panel meets NEMA 4/IP65 specifications for indoor use when properly installed. Installation Category II, Pollution Degree 2. Panel gasket and keps nuts included. 12.WEIGHT: 2.7 lbs (1.2 kg) (less module) About the MPAX Input Modules The MPAX Module serves as the input to the LPAX Display. There are several different modules to cover a variety of inputs. The MPAX module provides input scaling which allows the LPAX to display most any engineering unit. Once the MPAX is inserted into the LPAX, the unit has the same functions and capabilities of our PAX Series Intelligent Panel Meters. Note: The MPAX provides the operating power for the LPAX, therefore you must select either the AC or DC MPAX corresponding with your application and available power. Selecting Your Display Components SIGNAL TYPE INPUT RANGES MPAX MODULES* LPAX DISPLAYS 85-250 VAC 11 TO 36 VDC/ 24 VAC Universal DC Inputs DC Voltage 200 mV, 2 V, 20 V, 300 V DC Current 200 µA, 2 mA, 20 mA, 200 mA, 2 Amp  Resistance 100 ohm, 1000 ohm, 10 K ohm MPAXD000 MPAXD010 LPAX0500 Process Inputs 0-20 mA or 0-10 VDC MPAXP000 MPAXP010 LPAX0500 Temperature Inputs Thermocouples-T, E, J, K, R, S, B, N, C, or Custom Scaling RTD’s-100 ohm Pt (platinum) 385/392, 120 ohm Nickel 672, or  10 ohm Copper 427 MPAXT000 MPAXT010 LPAX0500 Strain Gage/Loadcell 24 mV or 240 mV MPAXS000 MPAXS010 LPAX0500 True RMS AC Voltage/Current AC Voltage 200 mV, 2 V, 20 V, 300 V  AC Current 200 uA, 2 mA, 20 mA, 200 mA, 5 Amp MPAXH000 N/A LPAX0500 To build a complete display unit, you will need an LPAX and an MPAX Input Module. The LPAX is only a display and will not operate without an MPAX module. Please use the following chart to identify the appropriate MPAX module (including supply power) and LPAX Display that will satisfy your application. OPTION CARDS AND ACCESSORIES WARNING: Disconnect all power to the unit before installing option cards. Adding Option Cards The PAX and MPAX series meters can be fitted with up to three option cards. The details for each option card can be reviewed in the specification section of the PAX bulletin. Only one card from each function type can be installed at one time. The function types include Setpoint Alarms (PAXCDS), Communications (PAXCDC or PAXUSB), and Analog Output (PAXCDL). The option cards can be installed initially or at a later date. COMMUNICATION CARDS (PAXCDC) A variety of communication protocols are available for the PAX and MPAX series. Only one of these cards can be installed at a time. When programming the unit via Crimson, a Windows® based program, a USB, RS232 or RS485 Card must be used. PAXCDC10 - RS485 Serial (Terminal) PAXCDC1C - RS485 Serial (Connector) PAXCDC20 - RS232 Serial (Terminal) PAXCDC2C - RS232 Serial (Connector) PAXCDC30 - DeviceNet PAXCDC40 - Modbus (Terminal) PAXCDC4C - Modbus (Connector) PAXCDC50 - Profibus-DP PAXUSB00 - USB Programming SETPOINT CARDS (PAXCDS) The PAX and MPAX series has 5 available setpoint alarm output option cards. Only one of these cards can be installed at a time. (Logic state of the outputs can be reversed in the programming.) PAXCDS10 - Dual Relay, FORM-C, Normally open & closed PAXCDS20 - Quad Relay, FORM-A, Normally open only PAXCDS30 - Isolated quad sinking NPN open collector PAXCDS40 - Isolated quad sourcing PNP open collector PAXCDS50 - Dual Triac/Dual SSR drive LINEAR DC OUTPUT (PAXCDL) Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available from the analog output option card. The programmable output low and high scaling can be based on various display values. Reverse slope output is possible by reversing the scaling point positions. PAXCDL10 - Retransmitted Analog Output Card *For detailed Module specifications, see corresponding PAX literature. (i.e. For MPAXD specifications, see the PAXD literature)

Bulletin No. LPAX5-E

Drawing No. LP0489 UNITS LABEL (LX) The LPAX Display has an area on the front panel designed for a custom units label. The units label is applied directly to the panel in the embossed area. The units backlight is then turned on via programming. Available on 5-digit version only. Refer to the LPAX Accessories Bulletin for a list of available units labels. PROGRAMMING SOFTWARE Crimson 2 is a Windows® based program that allows configuration of the LPAX meter from a PC. Crimson offers standard drop-down menu commands, that make it easy to program the LPAX meter. The LPAX program can then be saved in a PC file for future use. A PAX serial option card is required to program the meter using the software. 1.0 ASSEMBLING THE DISPLAY CAUTION: The MPAX main circuit board and the option cards contain static sensitive components. Before handling the module or the cards, discharge static charges from your body by touching a grounded bare metal object. Handle the module by the rear plastic cover only, and the option cards by the board edges. Dirt, oil or other contaminants that contact the circuit boards or components can adversely affect circuit operation. WARNING: Exposed line voltage exists on the MPAX main circuit board and the option cards. DO NOT apply power to the module OR load circuits until the module is properly installed in the LPAX case. NOTE: All module and option card labels must be installed as shown for safety purposes. Removing The MPAX Module To remove the MPAX Module from the LPAX Display, first remove all power and load circuits. Then insert a flat screwdriver blade (3/16" or 1/4") into the narrow slot between the LPAX rear cover plate and the module’s plastic cover as illustrated in Figure 2. Twist the screwdriver in the direction shown to disengage the internal connectors while firmly squeezing and pulling back on the rear finger tabs (top and bottom). Carefully slide the module out of the LPAX case, keeping it properly aligned with the case opening. Figure 2, Removing an MPAX Module CAUTION: 1 2 3 4 5 6 7 8 9 10 11 DISCONNECT ALL POWER BEFORE INSTALLING OR REMOVING MODULE SLOT TWIST ! WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM), INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT (AT THE ARROW) AND TWIST IN THE DIRECTION SHOWN. TO REMOVE MODULE: MODEL LPAX RED LION CONTROLS YORK, PA. MADE IN U.S.A. PAXCDC10 RS485 COMMUNICATION 12 13 14 15 - B(-) - A(+) - COMM - N/C 1 2 3 4 5 6 7 8 9 10 11 ~ ~ AC AC 85-250VAC 50/60Hz 14VA COMMUNICATION OPTION ANALOG OUT OPTION SETPOINT (SP) OPTION MODEL PAXD RED LION CONTROLS YORK, PA. MADE IN U.S.A. SEE LITERATURE FOR JUMPER SELECTION SIGNAL INPUTS USER INPUTS VOLT/OHM CURRENT +EXCITATION COMM 1 2 3 N/C COMM ! R - 19 17 + 18 - + 16 ANALOG OUTPUT PAXCDL10 RLY3 25 21 RLY2 22 COMM RLY1 20 QUAD RELAY S.P. PAXCDS20 0-10V ANALOG OUTPUT OUTPUT ANALOG 0-20mA 24 23 COMM RLY4 RELAYS RATED 3A @ 250VAC (RESISTIVE LOAD) MODULE CONNECTOR MODULE REAR COVER CAUTION LABEL MODULE RETENTION LATCH (TOP AND BOTTOM) OPTION CARD(S) INSTALLED ON THIS SIDE MPAX MAIN CIRCUIT BOARD (BOTTOM SIDE) TERMINAL #1 MODULE AND OPTION CARD(S) LABELS (APPLY TO REAR COVER PLATE) CAUTION DISCONNECT ALL POWER BEFORE OPENING LPAX DISPLAY REAR VIEW METAL PANEL MUST BE CONNECTED TO ! E MA2204X Figure 1, Installing an MPAX Module and Option Cards Prior to installing the LPAX Display, it is recommended that the MPAX and any option cards be assembled first. This will allow you the opportunity to insure all the boards are fitted properly into their connectors. Installing the Option Cards If your application requires option cards, they should be installed into the MPAX before it is installed into the LPAX Display. Refer to the literature enclosed with the option cards for installation instruction. Installing the MPAX To install the MPAX Module, align the module with the opening in the LPAX case, as illustrated. The module must be oriented as shown, with terminal #1 toward the top of the LPAX case. Carefully slide the module into the LPAX case. The LPAX and MPAX connectors will begin to engage about ¼" from the bottom. At this point, apply a small amount of pressure to the rear of the MPAX module to fully engage the connection. Be sure the module fully snaps into the slots at the rear of the LPAX case. The display is ready for installation. Installing the Labels Each option card and the MPAX are shipped with a connection label. These labels must be applied to the rear of the LPAX in the positions shown in the drawing.

Bulletin No. LPAX5-E

Drawing No. LP0489 LPAX DISPLAY INSTALLATION CAUTION: 1 2 3 4 5 6 7 8 9 10 11 DISCONNECT ALL POWER BEFORE INSTALLING OR REMOVING MODULE SLOT TWIST ! WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM), INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT (AT THE ARROW) AND TWEIST IN THE DIRECTION SHOWN. TO REMOVE MODULE: MODEL LPAX RED LION CONTROLS YORK, PA. MADE IN U.S.A. PAXCDC10 RS485 COMMUNICATION 12 13 14 15 - B(-) - A(+) - COMM - N/C 1 2 3 4 5 6 7 8 9 10 11 ~ ~ AC AC 85-250VAC 50/60Hz 14VA COMMUNICATION OPTION ANALOG OUT OPTION SETPOINT (SP) OPTION MODEL PAXD RED LION CONTROLS YORK, PA. MADE IN U.S.A. SEE LITERATURE FOR JUMPER SELECTION SIGNAL INPUTS USER INPUTS VOLT/OHM CURRENT +EXCITATION COMM 1 2 3 N/C COMM ! R - 19 17 + 18 - + 16 ANALOG OUTPUT PAXCDL10 RLY3 25 21 RLY2 22 COMM RLY1 20 QUAD RELAY S.P. PAXCDS20 0-10V ANALOG OUTPUT OUTPUT ANALOG 0-20mA 24 23 COMM RLY4 RELAYS RATED 3A @ 250VAC (RESISTIVE LOAD) MODULE RETENTION LATCH (TOP AND BOTTOM) MOUNTING PANEL PANEL GASKET FRONT PANEL MODULE RELEASE FINGER TAB (TOP & BOTTOM) CASE VENT HOLES REAR COVER PLATE CAUTION DISCONNECT ALL POWER BEFORE OPENING CONNECTED TO MUST BE METAL PANEL MA2204X E ! CONNECT THIS STUD TO A PROTECTIVE EARTHING SYSTEM MOUNTING STUDS AND NUTS (6 PLACES) The LPAX display is intended to be mounted into a panel or enclosure. The display is provided with a gasket to provide a water-tight seal. The recommended minimum panel thickness for NEMA 4/IP65 sealing is 0.060" (1.57 mm). For panel mounting, prepare the panel cut-out to the dimensions shown. The supplied template may be used to mark the cut-out and hole locations on the panel. After the panel cut-out has been deburred, slide the panel gasket over the rear of the display and onto the mounting studs. Insert the display into the panel cut-out as illustrated in Figure 3. Install six # 10-32 keps nuts (supplied) and tighten evenly for uniform gasket compression. Do not over-tighten the nuts. By using additional mounting accessories, the LPAX can be surface-wall mounted, suspended, or bottom mounted. Separate installation instructions are provided with the mounting accessories. Environment And Cleaning 3.0 WIRING AND PROGRAMMING THE DISPLAY The display should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the system near devices that generate excessive heat should be avoided. The bezel should be cleaned only with a soft cloth and neutral soap product. Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the aging process of the bezel. 2.0 INSTALLING THE DISPLAY Figure 3, Installing The LPAX Into A Panel Once assembled, the LPAX and MPAX have all the same functions and capabilities of our PAX Series Intelligent Panel Meters. Therefore, you will find the appropriate PAX information packed with the MPAX Module. Follow the instructions found in the appropriate PAX documentation to wire and program the display for your application. TROUBLESHOOTING If for any reason you have trouble operating, connecting, or simply have questions concerning your new unit, contact Red Lion’s technical support. Email: [email protected] Website: www.redlion.net Inside US: +1 (877) 432-9908 Outside US: +1 (717) 767-6511 ORDERING INFORMATION 1 Refer to “Selecting Your Display Components and Option Cards.”  Crimson® software is available for free download from http://www.redlion.net/ TYPE MODEL NO. DESCRIPTION PART NUMBER Display LPAX 5-Digit Extra Large Display for Analog MPAX Modules LPAX0500 Analog Input Module MPAX Universal DC Input Module, AC Powered MPAXD000 Universal DC Input Module, DC/24 VAC Powered MPAXD010 Process Input Module, AC Powered MPAXP000 Process Input Module, DC/24 VAC Powered MPAXP010 Thermocouple and RTD Module, AC Powered MPAXT000 Thermocouple and RTD Module, DC/24 VAC Powered MPAXT010 AC True RMS Voltage and Current Module, AC Powered MPAXH000 Strain Gage/Bridge Input Module, AC Powered MPAXS000 Strain Gage Input Module, DC/24 VAC Powered MPAXS010 Option Cards PAXCDS Dual Setpoint Relay Output Card PAXCDS10 Quad Setpoint Relay Output Card PAXCDS20 Quad Setpoint Sinking Open Collector Output Card PAXCDS30 Quad Setpoint Sourcing Open Collector Output Card PAXCDS40 Dual Triac/Dual SSR Drive Output Card PAXCDS50 PAXCDC 1 RS485 Serial Communications Card with Terminal Block PAXCDC10 Extended RS485 Serial Communications Card with Dual RJ11 Connector PAXCDC1C RS232 Serial Communications Card with Terminal Block PAXCDC20 Extended RS232 Serial Communications Card with 9 Pin D Connector PAXCDC2C DeviceNet Communications Card PAXCDC30 Modbus Communications Card PAXCDC40 Extended Modbus Communications Card with Dual RJ11 Connector PAXCDC4C Profibus-DP Communications Card PAXCDC50 PAXCDL 1 Analog Output Card PAXCDL10 PAXUSB PAX USB Programming Card PAXUSB00 Accessories CBLUSB USB Programming Cable Type A-Mini B CBLUSB01 LX Custom Units Label Listed Separately ENC9 NEMA 4 Enclosure for LPAX ENC90000 SHR Shroud for LPAX SHRLPAX0 MB Mounting Bracket for LPAX MBLPAX00