Red Arrow Trading LFACLED502F Installation Instructions

Text of the manual

LED Maintained Emergency

Recessed Fitting Installation Instructions p.1 Red Arrow Trading Elsworth House, Herries Road South Sheffield, S6 1QS T: 0800 195 0006 F: 0870 043 3946 E: [email protected] www.redarrowtrading.com For models: LFACLED502F Specification • 220-240V • 2.5W Wattage • 6.5W Power consumption • 50pcs of Ø5 LED • 297 Lumen output (201lm in emergency mode) • 6000-7000K Colour temperature • > 3 Hours emergency duration • 24 Hours charging time This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference. ENSURE FITTING IS CHARGED FOR A MINIMUM OF 24 HOURS PRIOR TO TESTING. Installation 1. Remove the diffuser from the body by removing the two screws. 2. Release gear tray by removing the two retaining screws. 3. Cut out hole for fitting, 120 x 340mm, in the ceiling tile. 4. ISOLATE THE A.C. SUPPLY and connect unit. An unswitched 240V A.C. supply must be connected to the Live (L). Earth and Neutral (N) terminals on the PCB block. On Maintained circuits continuous illumination can be achieved by connecting a link between L and Lsw either locally or through a remote switch. 5. Place the fitting into the hole and screw the arm screws so that the arms are fully down. 6. Allow the fitting to rest on the arms. 7. Plug battery lead into connector on the PCB. 8. Locate the bezel under the fitting and secure using the 2 long screws supplied. 9. Re-secure the gear tray into the base of the unit making sure that the mains cable is not trapped by the PCB etc. 10. Operational check - restore the A.C. supply for 30 minutes and then remove. The LEDs should illuminate for at least 10 seconds. 11. Restore the A.C. supply and check that the indicator LED is ‘on.’ Quick Guide 1. 2. 3.

T: 0800 195 0006 F: 0870 043 3946

E: [email protected] www.redarrowtrading.com Red Arrow Trading Elsworth House, Herries Road South Sheffield, S6 1QS LED Maintained Emergency Recessed Fitting Installation Instructions p.2 For models: LFACLED502F 4. 5. 6. Operation Non-Maintained Lamp normally off and battery on automatic charge (LED ‘on’) when A.C. supply is healthy. Solid state circuitry automatically switches lamp on when A.C. supply is interrupted. Maintained Emergency lamp normally on, when the supply to Lsw is switched on. The battery is on automatic charge (LED ‘on’). Lamp will switch on or remain on if A.C. supply is interrupted. Monitoring Green indicator lamp (LED) normally continuously ‘on’. Indicator lamp goes out if A.C. supply or charger fails. Battery Sealed Nickel-Cadmium rechargeable battery pack. Temperature Performance figures measured at 25 degrees C. Fault Finding and Corrective Action Monitoring LED Not Illuminated A.C. supply not healthy. Battery not connected. Charger failed. Unit Not Meeting Required Emergency Period May need cycling: Discharge then recharge for 24 hours. Re-test, battery pack may need replacing if emergency duration still not met.

LED Maintained Emergency

Recessed Fitting Installation Instructions p.3 For models: LFACLED502F T: 0800 195 0006 F: 0870 043 3946 E: [email protected] www.redarrowtrading.com Red Arrow Trading Elsworth House, Herries Road South Sheffield, S6 1QS LEDs Not Fully Illuminated If the LEDs are not illuminated check connections & if correct either the battery pack or (less likely) the printed circuit board needs replacing. RECOMMENDED ROUTINE TEST PROCEDURE The following test is designed to ensure the continued protection of your premises and occupants. Because of the possibility of a failure of the normal lighting supply occurring shortly after a period of testing, all tests should whenever possible, be undertaken at times of least risk, e.g. during daylight hours. ONCE A DAY Visual inspection of battery charge led. ONCE A MONTH Each unit should be energised from it’s battery for adequate time to ensure, by simulation of a failure of the normal lighting supply, the emergency mode is functioning correctly. ONCE A YEAR All units should be placed into emergency mode and checked that the duration provided by the battery meets the specified time period. Clean the internal and external surface of the diffuser. Month Test Year 1 Year 2 Year 3 Year 4 Year 5 signed date signed date signed date signed date signed date 1 Functional 2 Functional 3 Functional 4 Functional 5 Functional 6 1 hour 7 Functional 8 Functional 9 Functional 10 Functional 11 Functional 12 1 hour 3 hour Guarantee This product is guaranteed for a period of 1 year from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The guarantee is also invalidated if the luminaire has been Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice. Product complies with all relevant European standards Product is suitable for mounting on flammable material F

Other Lighting Equipment Manuals