Taylor 62 Operator's Manual

Text of the manual

Original Operating Instructions

051059-M 4/00 (Original Publication) Updated 9/26/16

Complete this page for quick reference when service is required:

Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity: A  2000 Taylor Company 051059−M Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be a violation of Copyright Law of the United States of America and other countries, could result in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072

Models 60 & 62

Table of Contents Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installer Safety 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Site Preparation 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Connections (Water Cooled Units Only) 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Cooled Units 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Connections 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Beater Rotation 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refrigerant 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 2 To the Operator 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compressor Warranty Disclaimer 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 3 Safety 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 4 Operator Parts Identification 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 5 Important: To the Operator 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Switch 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dial Light 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indicator Light (“Mix Low”) 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indicator Light (“Mix Out”) 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset Mechanism 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Consistency Control* 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spinner Rinse Switch* 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Lift Switch (Model 60 Only)* 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Foot Pedal (Model 60 Only) 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flavor Selector Switch* 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 6 Operating Procedures 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sanitizing 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Priming 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Syrup System 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drawing Product 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table of Contents

Models 60 & 62 Table of Contents − Page 2 Closing Procedures 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Draining Product From The Freezing Cylinder 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rinsing 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disassembly 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brush Cleaning 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sanitizing Syrup System 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 7 Important: Operator Checklist 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . During Cleaning and Sanitizing: 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Bacterial Count: 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Regular Maintenance Checks: 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Winter Storage 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 8 Troubleshooting Guide 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 9 Parts Replacement Schedule 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 10 Limited Warranty on Equipment 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 11 Limited Warranty on Parts 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Note: Continuing research results in steady improvements; therefore, information in this manual is subject to change without notice. Note: Only instructions originating from the factory or its authorized translation representative(s) are considered to be the original set of instructions.  2000 Taylor Company (Original Publication) (Updated September, 2016) 051059−M Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be a violation of Copyright Law of the United States of America and other countries, could result in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072

Models 60 & 62

To the Installer 131108 Section 1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. Installer Safety In all areas of the world, equipment should be installed in accordance with existing local codes. Please contact your local authorities if you have any questions. Care should be taken to ensure that all basic safety practices are followed during the installation and servicing activities related to the installation and service of Taylor equipment.  Only authorized Taylor service personnel should perform installation and repairs on the equipment.  Authorized service personnel should consult OSHA Standard 29CFRI910.147 or the applicable code of the local area for the industry standards on lockout/tagout procedures before beginning any installation or repairs.  Authorized service personnel must ensure that the proper PPE is available and worn when required during installation and service.  Authorized service personnel must remove all metal jewelry, rings, and watches before working on electrical equipment. The main power supply(s) to the machine must be disconnected prior to performing any repairs. Failure to follow this instruction may result in personal injury or death from electrical shock or hazardous moving parts as well as poor performance or damage to the equipment. Note: All repairs must be performed by an authorized Taylor Service Technician. This unit has many sharp edges that can cause severe injuries. Site Preparation Review the area where the unit will be installed before uncrating the unit. Make sure that all possible hazards to the user and the equipment have been addressed. For Indoor Use Only: This unit is designed to operate indoors, under normal ambient temperatures of 70-75F (21-24C). The freezer has successfully performed in high ambient temperatures of 104(40C) at reduced capacities. This unit must NOT be installed in an area where a water jet or hose can be used. NEVER use a water jet or hose to rinse or clean the unit. Failure to follow this instruction may result in electrocution. This unit must be installed on a level surface to avoid the hazard of tipping. Extreme care should be taken in moving this equipment for any reason. Two or more people are required to safely move this unit. Failure to comply may result in personal injury or equipment damage. Uncrate the unit and inspect it for damage. Report any damage to your Taylor Distributor. This piece of equipment is made in the USA and has USA sizes of hardware. All metric conversions are approximate and vary in size.

Other Freezer Manuals