Scale Computing HC3 Installation Manual

Specifications

Brand: Scale Computing
Category: Server
Model: HC3 (Installation Manual)
File Type: PDF
File Size: —
Pages: 21

Read Online

Read the Scale Computing HC3 Installation Manual online using the built-in PDF viewer.

Text of the manual

HC3 Hardware and System

Installation Guide © ​Scale Computing 2019 Version 3.0: 02/2019 | 1

Table of Contents

Important Safety and Usage Information 3 Online Installation Reference 4 Networking Preparations 4 System Preparations and Configurations 4 Rack Installation 4 HC3 Shipping, Hardware, and Power 5 HC3 Family Shipping 5 HC1000 Family Hardware 5 Compute and Networking 5 Storage 6 Miscellaneous 6 HC5000 Family Hardware 7 Compute and Networking 7 Storage 7 Miscellaneous 7 HC1000 Family Environment and Power Specifications 8 HC5000 Family Environment and Power Specifications 9 HC3 Software Only Environment and Power Specifications 10 HC3 Installation Preparation 12 What to Expect After Your Purchase 12 Pre-Installation Checklist 12 Customer Portal Access 13 Partner and Distributor Portal Access 13 Login or Register for a Portal Account 14 Environment Questionnaire 15 Scheduling Your Professional Services 16 Node Configuration 18 Configure the Nodes 18 Common Configuration Troubleshooting 19 System Initialization 20 Initialize the System 20 What Next? 21 Videos 21 Technical Help 21 Feedback & Support 21 © ​Scale Computing 2019 Version 3.0: 02/2019 | 2

Important Safety and Usage Information

1. Please disconnect ​ALL​ power and network cords before servicing or moving the unit. 2. Please note all chassis manufacturers' safety instructions for proper node lifting and transport. 3. This product is intended for installation in a restricted access location or equivalent area. Please ensure appropriate precautions are taken as confidential and/or sensitive data may be stored on this product after installation. 4. This product’s BIOS configuration may use replaceable batteries as a backup power source in the event that a power outage occurs. If you suspect the batteries have failed, ​DO NOT​ attempt to replace them yourself due to risk of injury if an improper replacement is used. Contact your hardware support provider for proper replacement steps. 5. Elevated Operating Ambient​ - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. 6. Reduced Air Flow​ - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 7. Mechanical Loading​ - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. 8. Circuit Overloading​ - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. 9. Reliable Earthing​ - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). © ​Scale Computing 2019 Version 3.0: 02/2019 | 3

Online Installation Reference

Thank you for your recent Scale Computing HC3 System purchase! We are excited to have you as a customer and look forward to making sure you are satisfied with every part of your experience with Scale Computing. Scale Computing aims to provide you with an informative and productive introduction to your new HC3 System solution. If you haven’t already, check out the convenient ​online installation references​ that pair with this HC3 Hardware and System Installation Guide. Networking Preparations Reference the ​Networking Guidelines and Recommendations​ guide for the most up-to-date information on networking best practices and recommended configurations, as well as references for port requirements, physical NIC layouts, and more. System Preparations and Configurations Reference the ​HyperCore Support Matrix​ for the latest on supported node configurations, system limitations and best practices, virtual drivers, supported web browsers, and much more. Rack Installation Watch the ​2 minute video​ for your purchased model for step-by-step assistance when racking the node. And yes, it's really that easy! If you're utilizing an HC3 Software Only node model - currently a Lenovo x3550 M5, Lenovo SR630, or Lenovo SR650 platform - please see your hardware manufacturer's documentation and/or resources for information on proper mounting, racking, and installation of your hardware lines. © ​Scale Computing 2019 Version 3.0: 02/2019 | 4

HC3 Shipping, Hardware, and Power

It is important to understand the underlying hardware capabilities and power requirements of your specific node lines. You'll find the base build options for each HC3 family line as well as their available upgrades in this chapter. HC3 Family Shipping HC1200 HC1250 HC1250D HC1250DF HC5250D Shipping Dimensions 32" L x 23" W x 7" H 39" L x 24" W x 9" H 39" L x 24" W x 11" H Shipping Weight 40 lbs 56 lbs 77 lbs Carry Weight Out of Box 36 lbs Minimum: 26.2 lbs (11.9 kg) Maximum: 41.4 lbs (18.8 kg) Minimum: 41.9 lbs (19 kg) Maximum: 70.5 lbs (32 kg) HC1000 Family Hardware Compute and Networking HC1200 Standard HC1250 Standard HC1200 Upgrade Options HC1250 Upgrade Options HC1250D(F) Standard HC1250D(F) Upgrade Options CPU Intel Xeon SP 3104 6 Cores - 6 Threads 1.7GHz Intel Xeon SP 4110 8 Cores - 16 Threads 2.1GHz Intel Xeon SP 4110 8 Cores - 16 Threads 2.1GHz Intel Xeon SP 4114 10 Cores - 20 Threads 2.2GHz 2 x Intel Xeon SP 4110 16 Cores - 32 Threads 2.1GHz 2 x Intel Xeon SP 4114 20 Cores - 40 Threads 2.2GHz 2 x Intel Xeon SP 6136 24 Cores - 48 Threads 3.0GHz RAM 64GB DDR4 96GB DDR4 128GB DDR4 192GB DDR4 256GB DDR4 384GB DDR4 128GB DDR4 192GB DDR4 256GB DDR4 384GB DDR4 512GB DDR4 768GB DDR4 Networking 4 x 1GbE or 10GbE 10GBaseT (RJ-45) Intel X550-T2 2 Public NICs Bonded Active/Passive 2 Private NICs Bonded Active/Passive 4 x 10GbE SFP+ Intel X710-DA4 2 Public NICs bonded active/passive 2 Private NICs bonded active/passive 4 x 1GbE or 10GbE 10GBaseT (RJ-45) Intel X722 2 Public NICs Bonded Active/Passive 2 Private NICs Bonded Active/Passive 4 x 10GbE SFP+ Intel X722 2 Public NICs bonded active/passive 2 Private NICs bonded active/passive Power Supply 2 x 500W Redundant Power Supplies 2 x 750W Redundant Power Supplies © ​Scale Computing 2019 Version 3.0: 02/2019 | 5

Storage Upgrade Options

HC1200 NL-SAS (7200 RPM) 4TB RAW Capacity / 2TB Usable Capacity (4x1TB) NL-SAS (7200 RPM) 8TB RAW Capacity / 4TB Usable Capacity (4x2TB) 16TB RAW Capacity / 8TB Usable Capacity (4x4TB) 32TB RAW Capacity / 16TB Usable Capacity (4x8TB) HC1250 NL-SAS (7200 RPM) 3TB RAW Capacity / 1.5TB Usable Capacity (3x1TB) SSD 480GB RAW Capacity / 240GB Usable Capacity (1x480GB) NL-SAS (7200 RPM) 6TB RAW Capacity / 3TB Usable Capacity (3x2TB) 12TB RAW Capacity / 6TB Usable Capacity (3x4TB) 24TB RAW Capacity / 12TB Usable Capacity (3x8TB) SSD 960GB RAW Capacity / 480GB Usable Capacity (1x960GB) 1.92TB RAW Capacity / 960GB Usable Capacity (1x1.92TB) 3.84TB RAW Capacity / 1.92TB Usable Capacity (1x3.84TB) 7.68TB RAW Capacity / 3.84TB Usable Capacity (1x7.68TB) HC1250D NL-SAS (7200 RPM) 3TB RAW Capacity / 1.5TB Usable Capacity (3x1TB) SSD 960GB RAW Capacity / 480GB Usable Capacity (1x960GB) NL-SAS (7200 RPM) 6TB RAW Capacity / 3TB Usable Capacity (3x2TB) 12TB RAW Capacity / 6TB Usable Capacity (3x4TB) 24TB RAW Capacity / 12TB Usable Capacity (3x8TB) SSD 1.92TB RAW Capacity / 960GB Usable Capacity (1x1.92TB) 3.84TB RAW Capacity / 1.92TB Usable Capacity (1x3.84TB) 7.68TB RAW Capacity / 3.84TB Usable Capacity (1x7.68TB) HC1250DF SSD 3.84TB RAW Capacity / 1.92TB Usable Capacity (4x960GB) SSD 7.68TB RAW Capacity / 3.84TB Usable Capacity (4x1.92TB) 15.37TB RAW Capacity / 7.68TB Usable Capacity (4x3.84TB) 30.72TB RAW Capacity / 15.36TB Usable Capacity (4x7.68TB) Miscellaneous Rack Certifications Miscellaneous HC1200 1U Rack Height 1.7” (43mm) H x 17.2” (437mm) W x 25.6” (650mm) D UL/CB, CE, FCC Rack Rails, Power Cables, Bezel Onboarding Reference Card HC1250 1U Rack Height 1.7” (43mm) H x 17.2” (437mm) W x 25.6” (650mm) D HC1250D 1U Rack Height 1.7” (43mm) H x 17.1” (434mm) W x 28.1” (715mm) D HC1250DF 1U Rack Height 1.7” (43mm) H x 17.1” (434mm) W x 28.1” (715mm) D © ​Scale Computing 2019 Version 3.0: 02/2019 | 6

HC5000 Family Hardware

Compute and Networking HC5250D Standard HC5250D Upgrade Options CPU 2 x Intel Xeon SP 4110 16 Cores - 32 Threads 2.1GHz 2 x Intel Xeon SP 4114 2 x Intel Xeon SP 6136 20 Cores - 40 Threads 24 Cores - 48 Threads 2.2GHz 3.0GHz RAM 128GB DDR4 192GB DDR4 256GB DDR4 384GB DDR4 512GB DDR4 768GB DDR4 1024GB DDR4 Networking 4 x 10GbE SFP+ Intel X722 2 Public NICs bonded active/passive 2 Private NICs bonded active/passive Power 2 x 750W Redundant Power Supplies Storage Base Storage Storage Upgrade Options HC5250D NL-SAS (7200 RPM) 36TB RAW Capacity / 18TB Usable Capacity (9x4TB) SSD 2.88TB RAW Capacity / 1.44TB Usable Capacity (3x960GB NL-SAS (7200 RPM) 72TB RAW Capacity / 36TB Usable Capacity (9x8TB) SSD 5.76TB RAW Capacity / 2.88TB Usable Capacity (3x1.92TB) 11.52TB RAW Capacity / 5.76TB Usable Capacity (3x3.84TB) 23.04TB RAW Capacity / 11.52TB Usable Capacity (3x7.68TB) Miscellaneous Rack Certifications Miscellaneous HC1250DF 2U Rack Height 3.4” (87mm) H x 17.5” (445mm) W x 28.3” (720mm) D UL/CB, CE, FCC Rack Rails, Power Cables, Bezel Onboarding Reference Card © ​Scale Computing 2019 Version 3.0: 02/2019 | 7

HC1000 Family Environment and Power Specifications

HC1200/1250 Operating Environment Operating Air Temperature 5°C - 35°C (41°F - 95°F) Non-Operating Air Temperature -40°C - 70°C (-40°F - 158°F) Operating Humidity 8% - 90% (non-condensing) Non-Operating Humidity 5% - 95% (non-condensing) HC1250D(F) Operating Environment Operating Air Temperature 10 °C - 35 °C (50 °F - 95 °F) Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude. Non-Operating Air Temperature 5 °C - 45 °C (41 °F - 113 °F) Storage Air Temperature -40 °C - +60 °C (-40 °F - 140 °F) Operating Humidity 8% - 80% (non-condensing) 21 °C (70 °F) Max Dew Point Storage Humidity 8% - 90% (non-condensing) HC1200 Power Idle Load Startup Staging Watts 138.4 204 147 37.1 Amps 1.2 1.804 1.199 0.307 kVA 0.1384 0.204 0.147 0.0371 BTU/hr 472.22 696.05 501.56 126.59 Test Voltage 121.1 120.6 120.9 121.2 HC1250 Power Idle Load Startup Staging Watts 142.7 204 161.3 37.5 Amps 1.18 1.81 1.334 0.309 kVA 0.1427 0.204 0.1613 0.0375 BTU/hr 486.89 696.05 550.36 127.95 Test Voltage 121.1 120.6 120.9 121.2 © ​Scale Computing 2019 Version 3.0: 02/2019 | 8

HC1250D(F) Power 10GbE SFP+

Idle Load Startup Staging Watts 145 227 177 25.8 Amps 0.84 0.954 1.106 0.89 kVA 0.145 0.227 0.177 0.0258 BTU/hr 494.74 774.52 603.92 88.03 Test Voltage 122.2 122.2 122.2 122.2 HC1250D(F) Power 10GBaseT Idle Load Startup Staging Watts 214 417 278 33.1 Amps 0.84 0.954 1.106 0.89 kVA 0.214 0.417 0.278 0.0331 BTU/hr 730.17 1422.80 948.54 112.94 Test Voltage 122.2 122.2 122.2 122.2 HC5000 Family Environment and Power Specifications HC5250D Operating Environment Operating Air Temperature 10 °C - 35 °C (50 °F - 95 °F) Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude. Non-Operating Air Temperature 5 °C - 45 °C (41 °F - 113 °F) Storage Air Temperature -40 °C - +60 °C (-40 °F - 140 °F) Operating Humidity 8% - 80% (non-condensing) 21 °C (70 °F) Max Dew Point Storage Humidity 8% - 90% (non-condensing) HC5250D Power 10GbE SFP+ Only Idle Load Startup Staging Watts 252 370 276 27.1 Amps 0.84 0.954 1.106 0.89 kVA 0.252 0.37 0.276 0.0271 BTU/hr 859.82 1262.44 941.71 92.47 Test Voltage 122.2 122.2 122.2 122.2 © ​Scale Computing 2019 Version 3.0: 02/2019 | 9

HC3 Software Only Environment and Power Specifications

Lenovo x3550 M5 Operating Environment Operating Air Temperature 5 °C - 40 °C (41 °F - 104 °F) Altitudes above 950 m decrease the maximum system temperature by 1 °C for every 175-m increase. Non-Operating Air Temperature 5 °C - 45 °C (41 °F - 113 °F) Storage Air Temperature -40 °C - +60 °C (-40 °F - 140 °F) Operating Humidity 8% - 85% (non-condensing) 24 °C Max Dew Point Storage Humidity 8% - 85% (non-condensing) 27 °C Max Dew Point Lenovo SR630 Operating Environment Operating Air Temperature 10 °C - 35 °C (50 °F - 95 °F) Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude. Non-Operating Air Temperature 5 °C - 45 °C (41 °F - 113 °F) Storage Air Temperature -40 °C - +60 °C (-40 °F - 140 °F) Operating Humidity 8% - 80% (non-condensing) 21 °C (70 °F) Max Dew Point Storage Humidity 8% - 90% (non-condensing) Lenovo SR650 Operating Environment Operating Air Temperature 10 °C - 35 °C (50 °F - 95 °F) Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude. Non-Operating Air Temperature 5 °C - 45 °C (41 °F - 113 °F) Storage Air Temperature -40 °C - +60 °C (-40 °F - 140 °F) Operating Humidity 8% - 80% (non-condensing) 21 °C (70 °F) Max Dew Point Storage Humidity 8% - 90% (non-condensing) © ​Scale Computing 2019 Version 3.0: 02/2019 | 10

All power and heat information provided below is approximate and may differ from your

environment depending on the hardware components you have selected. Lenovo x3550 M5 Power Idle Load Startup Staging Watts 92.6 161.4 116 14.1 Amps 0.746 1.336 0.6 0.095 kVA 0.0926 0.1614 0.116 0.0141 BTU/hr 315.95 550.70 395.79 48.11 Test Voltage 120.7 120.2 120.3 120.6 Lenovo SR630 Power Idle Load Startup Staging Watts 145 - 214 227 - 417 177 - 278 25.8 - 33.1 Amps 0.84 0.954 1.106 0.89 kVA 0.145 - 0.214 0.227 - 0.417 0.177 - 0.278 0.0258 - 0.0331 BTU/hr 494.74 - 730.17 774.52 - 1422.80 603.92 - 948.54 88.03 - 112.94 Test Voltage 122.2 122.2 122.2 122.2 Lenovo SR650 Power Idle Load Startup Staging Watts 252 370 276 27.1 Amps 0.84 0.954 1.106 0.89 kVA 0.252 0.37 0.276 0.0271 BTU/hr 859.82 1262.44 941.71 92.47 Test Voltage 122.2 122.2 122.2 122.2 © ​Scale Computing 2019 Version 3.0: 02/2019 | 11

HC3 Installation Preparation

All of the pertinent information you need to prepare for your HC3 system professional service engagements and installation. Interested in the full line up of Scale Computing Professional Services? Check out our ScaleCare White Paper ​here​ or our Professional Services page ​here​! What to Expect After Your Purchase Our experienced Customer Success Coordinator will be in touch with you regarding project planning and scheduling for your HC3 system. They will walk you through using the Customer or Partner Portal, answer general, non-technical questions, provide necessary documentation, and all-in-all make sure you have every tool you need for a successful implementation with the ScaleCare Support and Professional Services team! Once you are scheduled, your assigned ScaleCare engineer will contact you at the previously scheduled date and time with the provided contact number to walk you through your purchased professional services. These services may involve more than a single call to ensure the proper technical planning has been made and all of the necessary hardware is in place prior to the service engagement. Network and installation professional services will require physical access to the network environment, switches, and/or nodes as applicable in order to properly configure the hardware and assign IP schemes. Once the nodes are initialized, the HC3 web interface will be available through a web browser and the remainder of the professional services engagements will be handled through remote meetings with your ScaleCare engineers. NOTE If you have made the decision to self-install the HC3 system, ​please contact ScaleCare Support once the system is initialized for a system health check, any applicable software updates, and to make sure that the system is properly registered to your account. Choosing to self-install may delay your deployment in the event of any issues. ScaleCare Support reserves the right to take the necessary corrective actions on the system post self-install on a first-come, first-serve basis with preference given to previously scheduled professional services. Pre-Installation Checklist You will need the following equipment and information available and/or configured prior to the scheduled installation time. ● Review the ​Networking Guidelines and Recommendations​ for all of your networking environment requirements. ○ 1 LAN IP address for each node ○ 1 Backplane IP address for each node ○ Network Subnet mask for the LAN IP ○ LAN network Gateway IP address ○ All applicable cables for your node series (1 GbE, 10GBase-T, 10 GbE SFP+) © ​Scale Computing 2019 Version 3.0: 02/2019 | 12

Any other cable converters, VLAN information, or networking information unique for your environment

● Review the ​Support Matrix​ for supported configurations, supported operating systems, supported drivers, and more for your HC3 system implementation plans. ● Understand how to ​safely and properly rack​ your new HC3 nodes. ● Schedule​ your purchased professional services. ○ Credentials should be emailed to all users on the account with Scale Computing within 24 hours of product shipment (there is a typical 3 week build time before shipment). If you haven’t received credentials within that time frame you can sign up manually by selecting New User? under the appropriate Portal. ● Hardware installation tools. ○ A Phillips-head screwdriver for installing the rail kit if needed ○ A standard VGA monitor and USB keyboard to hook to the nodes for configuration ■ A KVM may be used but is not recommended for initial configuration ● A machine local to the HC3 system network for HC3 web interface access after configuration (VPNs, port forwarding, etc have been seen to block HC3 web interface access in the field) Customer Portal Access The customer Portal is for customer use only. Customers can use the Portal to: ● Manage account information ● Access assets ● Access shipments ● Access entitlements for support ● Create and manage support cases ● Schedule and monitor professional service engagements ● Access the Knowledge base for documentation, guides, application notes, frequently asked questions (FAQs), and best practices ● Access forums and question boards ● Contact representatives directly Customers automatically receive access to the customer Portal when they make their initial purchase of Scale Computing assets. Once the nodes have been shipped, customers will receive an email from [email protected] containing login information. Additional contacts from the company who are associated with the account can register for a new login from the proper Portal page ​here​ after the initial purchase. For more information about how to register for a new login at the Portal page, refer to ​Login or Register for a Portal Account​. Partner and Distributor Portal Access The partner Portal is for partners and distributors only. Partners can use the Portal to: ● Manage account information and view contacts ● Register deals, update existing registrations, and work assigned leads ● Access training materials, forums, and question boards ● Access the Knowledge database for documentation, guides, application notes, frequently asked questions (FAQs), and best practices © ​Scale Computing 2019 Version 3.0: 02/2019 | 13

Contact representatives directly

● Manage customer accounts (follow the ​Professional Services Scheduling video​) Distributors can use the Portal to: ● Manage account information and view contacts ● Register deals, update existing registrations, and work assigned leads ● View all deal registrations by their value added resellers (VARs) ● Access training materials, forums, and question boards ● Access the Knowledge database for documentation, guides, application notes, frequently asked questions (FAQs), and best practices ● Contact representatives directly Partners and distributors automatically receive access to the partner Portal when they sign Scale Computing’s partner agreement. After the agreement is signed, the partner account is activated and the partner receives an email from [email protected] containing login information. After that time, additional partner contacts associated with the partner that signed the agreement can register for a new login from the proper Portal page linked here​. Login or Register for a Portal Account Register for a Portal account to gain access to all of your account benefits. A short video regarding this topic can be found ​here​. 1. Open a web browser and navigate to www.scalecomputing.com. 2. Click Login in the upper right hand corner. 3. If you are a customer, click the Customer Portal link. If you are a partner or distributor, click the Partner Portal link. 4. The Login screen shown below appears. The login screen appears the same for both the customer Portal and partner Portal, so please be sure you are at the proper login page by verifying the URL. 5. If you have login credentials, type your username and password in the appropriate fields to access the Portal. 6. If you are an additional partner, distributor, or customer registering after initial access was granted to the account contacts, click New User? underneath the Username and Password fields. The New User Registration screen will appear as shown below. © ​Scale Computing 2019 Version 3.0: 02/2019 | 14

The registration screen is the same for partners, distributors, and customers; only the pathway differs. Ensure

you are at the correct landing page by verifying the URL. 8. Provide the appropriate information for the three categories: Account Information, Contact Information, and Address Information. The Email (Username) field will default to your Portal username for future access. The Community Nickname field will be your general-use name in the forums and chat boards. All fields marked in red are required. 9. Disregard the Password and Confirm Password fields. Your password is generated for you after registration and sent to you by email. If you do fill out a password here it is ignored by the system. 10. Click Register once the form is complete. Your request is logged and reviewed for approval. WARNING When you first log into the Scale Computing Portal be sure to fill out your 'My Profile' information from the top navigation bar. You can also adjust the time zone while scheduling individual services. The selected time zone in your profile will help to determine scheduling availability for your installation. Contact the Customer Success Coordinator and/or ScaleCare Support if you need assistance accessing the Portal or adjusting the time zone. Environment Questionnaire If you haven’t already, be sure to complete the environment questionnaire linked in your initial welcome email. It will look similar to the image below. © ​Scale Computing 2019 Version 3.0: 02/2019 | 15

Scheduling Your Professional Services

When you are ready to begin scheduling your professional services engagements, including your HC3 system installation, follow these steps. A short video regarding this topic can be found ​here​. WARNING Professional services can only be scheduled in their completion order. For example, the Networking Configuration Service will be required to be scheduled and completed before the HC3 System Installation Service can be scheduled. 1. Open a web browser and navigate to ​www.scalecomputing.com/support/login​. 2. Log in to the Customer Portal or Partner Portal as appropriate. 3. Point to Support on the top navigation bar and a drop down menu will appear. Select Services from the drop down choices. 4. The Professional Services page will be displayed. A list of all open professional services cases for your account will be shown along with their current Status. Select Schedule Services to the left of the appropriate case number to begin scheduling. 5. The Professional Services Scheduler will appear. All of the purchased and/or included professional services will be listed to the left of the page in the order they are required to be completed. 6. Confirm the listed time zone is correct. If not, select the correct time zone from the drop down list and click Update Time Zone before scheduling any events. © ​Scale Computing 2019 Version 3.0: 02/2019 | 16

Complete the Contact Info section as applicable for each professional service engagement. Some

professional service engagements have more than one step, as shown by the transitional arrows at the top of the scheduling details. NOTE All steps of a single professional service engagement can be scheduled in a single session, but will only allow each piece to be scheduled in order (the Planning Call cannot be scheduled after the Installation, for example). Each part of the current professional service will need to be completed before the next professional service engagement can be accessed. 8. Click an available date and time on the calendar and the appointment block below the Contact Info. 9. Confirm the selected date and time by clicking Schedule Time. If there is ever need to reschedule any upcoming events the Reschedule Future Calls button can be used. It cannot reschedule events in the past, however. 10. A confirmation email will be sent to the email address on record with the Portal user. © ​Scale Computing 2019 Version 3.0: 02/2019 | 17

Prior to configuring the individual nodes be sure to verify network and cabling setup has been completed. The node

configuration process confirms connectivity between nodes during IP configuration, as well as the ability to connect to a gateway before allowing node configuration to continue. In order to configure your nodes you must have serial or graphical console access to the physical nodes. Serial access is VT100 at 115,200 baud. Any standard VGA monitor and USB keyboard will work as a graphical console and are recommended. Configure the Nodes All installations should be scheduled at least 24 hours in advance. The ScaleCare engineer assisting you will provide the necessary credentials for command line access during the scheduled installation time. NOTE It is now possible to deploy a Single Node System (SNS). The commands provided below are applicable to a single node or multiple node installation. For a single node installation, proceed through Steps 1 to 4, and then skip to the next section, ​System Initialization​. All configuration of the nodes is done from the command line using a monitor and keyboard.​ Systems are configured in a top-to-bottom configuration, with the top node in the rack being the designated 'first' node. The 'first node' classification has no bearing on system operations outside of the installation configuration. 1. Hook the monitor and keyboard to the top node in the system. Access the node command line using the provided credentials. NOTE If the login prompt is not shown try pressing ​SHIFT to disable console blanking. If the login prompt is still not shown press ​CTRL+ALT+F1​ to ensure the correct console session is active. 2. Run the command to begin node configuration: ​sudo scnodeinit 3. You may be prompted for a password. Use the same password as the node login. 4. You will be prompted for each piece of IP and network information. Once the LAN IP, LAN Netmask, LAN Gateway, Backplane IP of this node, and Backplane IP of first node in system (which will be the same as Backplane IP of this node on the first node). See below for an example of the first node’s IP configuration. © ​Scale Computing 2019 Version 3.0: 02/2019 | 18

See the below image for the complete IP verification checks. The node configuration process is complete

when it either returns to the command line or the output says Entering forwarding state. The configuration process generally takes 3-5 minutes. Common Configuration Troubleshooting Here are some common troubleshooting steps for node configuration issues. ● Verify the node IPs were typed correctly. ● Verify the chosen LAN and Backplane IP for the node configuration are not already in use elsewhere on the network. ● The LAN and Backplane IPs must be on separate networks. The Backplane IP cannot be a publicly routable IP and cannot be in the assigned LAN IP network. You can use the following commands to re-initialize and/or bypass some network verification if needed for a test environment. WARNING ScaleCare Support advises against bypassing the built-in network checks unless this is for a test or lab environment and/or ScaleCare Support has specifically advised bypassing the checks as part of a troubleshooting process. Use of the bypass command outside of these instances has the potential to lead to networking issues within the initialized HC3 nodes and system that may require ScaleCare Support intervention and/or a system wipe and reset. 1. If the node initialization failed for any reason use this command to re-configure the node: REINITIALIZE=yes sudo scnodeinit 2. If a LAN gateway is not accessible or not responding to ICMP requests, use this command: BYPASS_NETWORK_CHECK=yes sudo scnodeinit 3. As used here, the options to re-configure a node and bypass LAN network checks can be combined: BYPASS_NETWORK_CHECK=yes REINITIALIZE=yes sudo scnodeinit © ​Scale Computing 2019 Version 3.0: 02/2019 | 19

Prior to initializing the system ensure all nodes have been successfully configured.

Initialize the System All installations should be scheduled at least 24 hours in advance. The ScaleCare engineer assisting you will provide the necessary credentials during the scheduled installation time. NOTE The commands provided below are applicable to a single node or multiple node installation. Choose the proper option for your configuration. All system initialization is done from the command line using a monitor and keyboard.​ Systems are configured in a top-to-bottom configuration, with the top node in the rack being the designated 'first' node. The 'first node' classification has no bearing on system operations outside of the installation configuration. 1. Hook the monitor and keyboard to the top node in the system. Log in to the node using the provided credentials. a. If you are utilizing the ​SNS configuration​ run the command to initialize the single node. sudo singleNodeCluster=1 scclusterinit b. If you are utilizing the ​cluster configuration​, this command will initialize a system comprised of all the previously configured nodes. sudo scclusterinit 2. You may be prompted for a password. Use the same password as the node login. 3. Configured nodes will be listed on the screen. Verify all nodes that were configured are displayed on the list for system initialization, as seen below. If utilizing the SNS configuration only the single node will be shown. 4. When all nodes are shown follow the prompt and press ​CTRL+c​ to proceed. 5. Enter ​yes​ to complete the system initialization as seen in the example below. 6. It will take approximately 15-20 minutes for the nodes to initialize in a cluster configuration. It will take approximately 10-15 minutes for a node to initialize in a SNS. Once complete the HC3 web interface will be accessible using the configured LAN IP of the node(s). 7. See the applicable User Guide for your software version for information on first-time system configuration if needed. © ​Scale Computing 2019 Version 3.0: 02/2019 | 20

Professional Services Scheduling Video (4.5 Minutes)

● HC3 Features ● HC3 “How To” Technical Help Find all of our Support Documentation online ​here​. ● Online Customer Onboarding References ● Scale Computing Networking Guidelines and Recommendations ● Scale Computing HyperCore Support Matrix Feedback & Support Document Feedback Scale Computing welcomes your suggestions for improving our documentation. Please send your feedback to [email protected]​. Technical Support and Resources There are many technical support resources available for use. Access this document, and many others, at http://www.scalecomputing.com/support/login/​. © ​Scale Computing 2019 Version 3.0: 02/2019 | 21