Fix the mounting frame as the figure shows. Do not make the screws to

be flush to the wall. Instead, leave 2 to 4mm exposed. 5.4 Fixed the inverter on the wall Falling equipment can cause serious or even fatal injury, never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking. WARNING Rise up the inverter a little higher than the bracket. Considered the weight of them. During the process please maintain the balance of the inverter.Hang the inverter on the bracket through the match hooks on bracket. Aft ...

< 0.5 W

Topology transformerless transformerless transformerless Cooling concept Natural Natural Natural Enclosure Type 3R Features DC connection: AC connection Screw terminal Screw terminal Screw terminal display LCD LCD LCD Interfaces: RS485/RS232/ Bluetooth/RF/Zigbee yes/yes/opt/ opt/opt yes/yes/opt/ opt/opt yes/yes/opt/ opt/opt Warranty: 10 years / 15 years yes /opt yes /opt yes /opt Certificates and approvals UL1741,UL1998 IEEE 1547, CSA C22.2 No.107.1-1,FCC Part15(Class A&B) Type 3R Type 3R Screw terminal Screw terminal Screw terminal 15.2 Efficie ...

5.3 Mounting the Inverter with bracket

LCD display Communications Start-Up and shut down the inverter 5 6 7 8 9 5.2 Selecting the installation location 5.4 Fixed the inverter on the wall 5.5 Check Inverter Installation Status 5.6 Electrical Connection 5.7 Commissioning Checking 6.1 Display and messages 6.2 Setting the LCD display 7.1 Monitoring Products 7.2 Monitoring System 7.3 RS485 cable connection 7.4 Using shine tool to set the information of the inverter 8.1 Start-Up the inverter 8.2 Disconnecting the Inverter 9.1 ...

16 Download Address

16 Download Address www.ginverter.com/Download.aspx 17 Contact 17 Contact If you have technical problems about our products, contact the Growatt Service line. We need the following information in order to provide you with the necessary assistance: Inverter type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment 53 ...

Through RS485 interface-Data logger

Through RS485 interface-Data logger+ PC Through RS485 interface-RS485-232 converter+ PC 7.3 RS485 cable connection 1. Unscrew the plastic connector. 2. Make the RS485 cable go through the connector. 3. Put two heat shrink tubes onto the front head of RS485 cable. 4. Insert the two metal head into relevant small cupreous hole, and fasten the connection by soldering. 35 36 ...

Use only solid or stranded wire but not fine stranded wire.

Use cables with high ambient temperatures. Use cables with a large cross-section . NOTICE Code Name Detail A Conductor cross-section Conductor cross-section B Stripping insulation 12mm 5.6.3 Connecting to the grid (AC utility) 5.6.3 Connecting to the grid (AC utility) Grid standard Before wiring the inverter, the installer needs to determine the grid configuration that the inverter will be connected to. The Growatt inverter is default set for utility interconnection with 240Vac from factory. However, you can choose the Net MODEL ...

Max. DC power

1800W 2300W 3200W Max. DC voltage 450V 500V 500V Start voltage 150V 150V 150V DC nominal voltage 360V 360V 360V PV voltage range 100V-450V 100V-500V 100V-500V Output data AC nominal voltage; range Default:240V single phase optional:208,240or277 single phase 183-228@208V 211-264V@240V 244-305@277V Phase shift (cos φ) 1 1 1 THDI <3% <3% <3% Single phase Single phase Single phase AC connection MPP voltage range 120V-400V 120V-450V 120V-450V Number of independent MPP trackers/strings per MPP tracker 1/1 ...

5.3 Mounting the Inverter with bracket

LCD display Communications Start-Up and shut down the inverter 5 6 7 8 9 5.2 Selecting the installation location 5.4 Fixed the inverter on the wall 5.5 Check Inverter Installation Status 5.6 Electrical Connection 5.7 Commissioning Checking 6.1 Display and messages 6.2 Setting the LCD display 7.1 Monitoring Products 7.2 Monitoring System 7.3 RS485 cable connection 7.4 Using shine tool to set the information of the inverter 8.1 Start-Up the inverter 8.2 Disconnecting the Inverter 9.1 ...

Growatt 2000-US user guide recommended for: Solar Charger 3500, MID 10KTL3-X, SPF 4000T DVM, MAX 175KTL3-X HV, 8000MTLP-S.

⚠️ Download Safety