GSI Electronics Agri-Alert 800EZe Quick Installation Manual

Specifications

Brand: GSI Electronics
Category: Security System
Model: Agri-Alert 800EZe (Quick Installation Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the GSI Electronics Agri-Alert 800EZe Quick Installation Manual online using the built-in PDF viewer.

Text of the manual

Wiring Diagram / Schéma de branchement

AA800EZe Interactive Tutorial Available Online ! AA800EZe Tutoriel interactif disponible en ligne ! http://www.viatron-electronics.com/aa800eze/ Agri-Alert 800EZe ZONE INPUTS Z5 COM Z6 Z3 COM Z4 Z1 COM Z2 Z7 COM Z8 1 2 - COMM - - + + NO C NC NO C NC ~ ~ 12VDC SIREN RELAY 1 RELAY 2 16VAC 1.5 k 1/2 W + - Battery / Batterie EARTH + - 12V + - *The system can also be powered by an external source of 12Vdc *Le système peut aussi être alimenté par une source d’alimentation 12Vdc 10-feet (3m) metal rod Tige métallique de 3 mètres (10pi) 12 Vdc device, max 500 mA Dispositif 12 Vcc, max 500 mA Siren, max 1 A (see Installation notes) Sirène, max 1 A (voir notes d’installation) Normally open relay (N.O.), 24 Vdc or Vac, 2 A max Relais normalement ouvert (N.O.), 24 Vcc ou Vca, 2 A max Normally close relay (N.C.), 24 Vdc or Vac, 2 A max Relais normal.fermé (N.C.), 24 Vcc ou Vca, 2 A max N.O. Circuit with EOLR resistor Circuit normalement ouvert avec résistance N.O. Circuit without EOLR resistor Circuit normalement ouvert sans résistance N.C. Circuit without EOLR resistor Circuit normalement fermé sans résistance N.C. Circuit with EOLR resistor Circuit normalement fermé avec résistance Power supply, wall transfo.* 16.5 Vac/40 Va Alimentation, transfo. mural* 16.5 Vca/40 Va Comm Phone card Carte téléphonique Battery socket Connecteur pour batterie Outdoor card Carte T° extérieure 891-00441, rev.03 Plug-in Cards / Cartes enfichables Agri-Alert 800EZe [EN] Installation Notes Cable Entry: Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure to prevent water infiltrations. Mounting the Enclosure on the Wall: Leave a clearance of at least 12” above the controller to allow the cover to be removed for maintenance. Zone Wiring: When connecting a zone, use the “COM” teminal that is the closest to the zone’s input terminal. Do not connect more than 2 zones on the same “COM” terminal. Siren Wiring: Prior to connecting the siren, make sure the battery is connected and works properly. If no siren is used, connect a 1.5KOhm 1/2W resistor between the positve and negative terminals of the siren or disable the siren monitoring function as explained in section 3.5 of the owner’s manual. [FR] Notes d’installation Entrée des câbles : Tous les fils entrant dans l’appareil doivent passer à travers la paroi inférieure du boîtier. Utiliser un marteau et un poinçon pour percer les trous qu’il vous faut. Ne jamais percer le dessus ni les côtés du boîtier pour prévenir les infiltrations d’eau. Fixation de l’appareil au mur : Laisser un espace libre d’au moins 12 pouces au-dessus de l’appa reil pour permettre d’ôter le couvercle et d’effectuer l’entretien. Branchement des zones : Lors du branchement d’une zone, utiliser le bornier “COM” situé au côté immédiat du bornier de la zone. Un maximum de 2 zones peuvent être connectées sur un même bornier “COM”. Branchement de la sirène : Assurez-vous que la batterie est branchée et qu’elle fonctionne correctement avant de brancher la sirène. Si la sirène n’est pas utilisée, relier une résistance de 1.5kOhm 1/2W entre le bornier positif et le bornier négatif de la sirène ou désactiver l’option de la sirène dans l’appareil (consulter la section 3.5 du manuel de l’usager). Phone Card Carte téléphonique Outdoor T° Card Carte T° extérieure Phone line OUT (sortie) Phone line IN (entrée) “PHONE CARD” “OUTDOOR” Ground (Terre) Ground (Terre) Quick connect pin / Fiche métallique Quick connect pin / Fiche métallique Outside T° sensor / Sonde T° extérieure CAUTION – To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. ATTENTION – Pour réduire les risques d’incendie, utiliser uniquement des conducteurs de télécommunications 26 AWG ou de section supérieure.

Step 1. Installation

Install the Agri-Alert in a location where a telephone jack, 120 volt AC power outlet, and proper grounding connections are readily available. Step 2. Wiring Refer to the wiring diagram overleaf. (Section 1.3) – Install and connect all zone sensors and the siren. If the alarm system uses the phone, connect the phone line to the Phone Plugin Card and then insert the card in the PHONE CARD port of the Agri-Alert. If the system uses an outside temperature sensor, connect the sensor to the Outdoor Plugin Card and then insert the card in the OUTDOOR port of the Agri-Alert. These 2 plugin cards are optional. Step 3. Earth Ground (Section 1.3.9) – Make proper ground connections. A faulty earth ground con- nection immediately voids the system warranty without further notice. Step 4. Power Supply Install the battery and then power up the Agri-Alert with the 16VAC wall trans- former (note that the system will not boot when connecting the battery). Step 5. Installation Wizard Launch the Installation Wizard (sec. 3.1). Main menu Install Programming Use Program Wizard Below is a list of all programming steps of the Installation Wizard. Refer to the proper section of this manual to get information about each programming step. - Time & Date (section 3.3) - Units of measurement (section 3.4) - Speaker volume (section 3.6) - Installer Password (section 3.2) - Setup Zones (section 3.7) - Phone Numbers (section 4.3 & 4.4) - Burglar arming options (section 5.4) - Siren Options (section 3.5) - Outdoor T° compensation (sec. 5.3) Step 6. Activating Zones (Section 3.7.8) Main menu Activate/Bypass Activate Zones Step 7. Recording Site ID (Section 3.8.2) Select the menu below to record the site’s identification message. Hierarchy Tree of Controller Menus Main menu System Auxiliaries User Preferences Voice ID System Message Step 8. Phone Call-in (Section 4.7) – If there is an answering machine, or fax machine on the same line as the alarm system, activate the “Share Phone Line” option. To call the alarm system from another phone, dial the site number and allow the site phone to ring only 1 time and then hang up. Wait 15 seconds and redial the site number. The Agri-Alert will pick up the call after the first ring. Main menu View / Modify Phone Call-in Step 9. System Test (Section 3.8.5) As a final step, always perform a system test. A successful test tells the Agri-Alert is ready to operate. It is recommanded to perform this test on a regular basis. Main menu Auto-Test Agri-Alert 800EZe – Quick Installation Guide Main Menu Current Conditions sec. 6.2 View / Modify Activate / Bypass sec. 5.5 System Self Test sec. 3.8.5 System Auxiliaries Help Menus sec. 2.2 Install Programming Zone Settings sec. 5.5.2 Phone Numbers sec. 4.4 Auto-Test Schedule sec. 4.9 Outdoor Probe sec. 5.3 Output Relays sec. 3.8.4 Siren Settings sec. 3.5 Burglar Zone Delays sec. 5.4.1 Phone Call-in sec. 4.7 On-Site Listening sec. 4.6 High Noise Alarm sec. 3.8.3 Time & Date sec. 3.3 Units sec. 3.4 Voice Volume sec. 3.6 Voice ID sec. 3.7.7 & 3.8.2 Update / Backup ch.10 Password Manage- ment sec. 3.2 Event Buffer sec. 6.3 User Preferences Software Version sec. 3.8.6 Change User sec. 3.2.2 Use Program Wizard sec. 3.1 Program Zones sec. 3.7 Program Dialer sec. 4.3 Program Auxiliaries Phone Enabled Zones sec. 4.8 Siren Enabled Zones sec. 3.7.6 Relay Assigned Zones sec. 3.7.5 Étape 5. Programmation Section 3.1 – Lancez l’assistant de pro- grammation. Menu principal Installation Assistant program. Voici la liste des étapes parcourues par l’assistant de programmation. Référez- vous au manuel de l’usager pour obtenir plus d’information. - Date & heure (section 3.3) - Unités de mesure (section 3.4) - Volume du haut-parleur (section 3.6) - Mot de passe installateur (section 3.2) - Configuration des zones (section 3.7) - Numéros de tél. (section 4.3 & 4.4) - Paramètres d’armement (section 5.4) - Paramètres de la sirène (section 3.5) - Compensation T° extérieure (sec. 5.3) Étape 6. Activation des zones (Section 3.7.8) Menu principal Activer/ Supprimer Activer une zone Étape 7. Message d’identification (Section 3.8.2) – Sélectionnez le menu suivant pour enregistrer le message d’iden tification du site. Étape 1. Installation Installez le système d’alarme là où une prise de téléphone, une prise 120 volt CA, et les installation pour la mise à la terre sont facilement accessibles. Étape 2. Branchements Consultez le schéma de branchement au verso. (Section 1.3) – Installez et branchez les détecteurs des zones et la sirène. Si la ligne télé phonique est utilisée, reliez le té- léphone à la carte enfichable télé phonique puis insérez la carte dans le port “PHONE CARD” de l’appareil. Si une sonde de température extérieure est utilisée, branchez-la sur la carte enfichable pour la lecture de température extérieure puis insérez la carte dans le port “OUTDOOR” de l’appareil (voir au verso). Notez que ces 2 cartes sont optionnelles. Étape 3. Mise à la terre (Section 1.3.9) – Effectuez une mise à la terre conforme de l’appareil. Une mise à la terre insufisante annule immédiatement la garantie sans préavis. Étape 4. Alimentation Branchez d’abord la batterie puis ali- mentez l’appareil avec le transfor mateur mural 16 VCA (notez que le système ne démarrera pas lors de la connexion de la batterie). Menu principal Système auxiliaire Préférences Message vocal Message système Étape 8. Réception d’appel (Section 4.7) Si un répondeur ou un té- lécopieur partage la ligne télé phonique de l’Agri-Alerte, activez le paramètre “Part- age de la ligne”. Pour appeler un module Agri-Alerte qui utilise une ligne partagée, vous devez composer le numéro de télé- phone du site, laisser sonner une seule fois puis raccrocher. Recomposez le numéro du site après 15 secondes, l’Agri-Alerte répondra dès la première sonnerie. Menu principal Voir / modifier Réception d’appels Étape 9. Essai du système (Section 3.8.5) Avant d’utiliser votre système Agri-Alerte, effectuez un test sur l’appareil pour vous assurer de son bon fonctionnement. Il est recom mandé d’effectuer ce test régulière ment. Menu principal Auto-test système Arborescence des menus Agri-Alert 800EZe – Guide d’installation rapide Menu principal Conditions courantes sec. 6.2 Voir / Modifier Activer / Supprimer sec. 5.5 Auto test du système sec. 3.8.5 Système auxiliaire Menus d'aide sec. 2.2 Installation Réglages des zones sec. 5.5.2 Numéros tél. sec. 4.4 Horaire d'auto-test sec. 4.9 Sonde extérieure sec. 5.3 Sorties relais sec. 3.8.4 Réglages de la sirène sec. 3.5 Délais zone de vol sec. 5.4.1 Réception d'un appel sec. 4.7 Écoute à distance sec. 4.6 Haut niveau de bruit sec. 3.8.3 Date et heure sec. 3.3 Unités sec. 3.4 Volume sec. 3.6 Message vocal sec. 3.7.7 & 3.8.2 Mise à jour / sauver chapt.10 Mots de passe sec. 3.2 Registre événements sec. 6.3 Préférences Version du logiciel sec. 3.8.6 Changer d'utilisateur sec. 3.2.2 Assistant de program. sec. 3.1 Program. des zones sec. 3.7 Program. du téléphone sec. 4.3 Program. auxiliaires Phone Enabled Zones sec. 4.8 Siren Enabled Zones sec. 3.7.6 Relay Assigned Zones sec. 3.7.5

Other Security System Manuals