Swan Analytical Instruments AMI Operator's Manual

Specifications

Brand: Swan Analytical Instruments
Category: Recording Equipment
Model: AMI (Operator's Manual)
File Type: PDF
File Size: —
Pages: 68

Read Online

Read the Swan Analytical Instruments AMI Operator's Manual online using the built-in PDF viewer.

Text of the manual

© 2017, SWAN ANALYTISCHE INSTRUMENTE AG, Switzerland, all rights reserved

subject to change without notice. Customer Support SWAN and its representatives maintain a fully trained staff of technical specialists around the world. For any technical question, contact your nearest SWAN representative, or the manufacturer: SWAN ANALYTISCHE INSTRUMENTE AG Studbachstrasse 13 8340 Hinwil Switzerland Internet: www.swan.ch E-mail: [email protected] Document Status Title: Monitor AMI Sample Sequencer Operator’s Manual ID: A-96.250.661 Revision Issue 00 Sept. 2011 First release 01 July 2012 Extended with connection to AMI Silica 02 Feb. 2013 Extended with connection to AMI Phosphate II 03 March 2017 Extended with connection to AMI Silitrace

AMI Sample Sequencer

A-96.250.661 / 120418 1 Table of Contents 1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1. Warning Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2. General Safety Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1. Measuring Cycle at Batch Measurement . . . . . . . . . . . . . . . . . . . 9 2.1.1 AMI Silica and AMI Phosphate HL . . . . . . . . . . . . . . . . . . . . . . 9 2.2. Measuring Cycle at Continuous Measurement. . . . . . . . . . . . . . . 12 2.2.1 AMI Sodium A and AMI Sodium P . . . . . . . . . . . . . . . . . . . . . . 12 2.2.2 AMI Silitrace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.3. Instrument Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2.4. Instrument Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.1. Installation Check List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2. Install the AMI Sample Sequencer . . . . . . . . . . . . . . . . . . . . . . . . 24 3.3. Connect Sample and Waste. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.4. Connect the Instrument (Mode ) . . . . . . . . . . . . . . . . . . . . 31 3.4.1 Connect the I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3.4.2 Sample Sequencer Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 3.4.3 Sample Sequencer Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 3.4.4 Firmware Settings (Mode ) . . . . . . . . . . . . . . . . . . . . . . . 35 3.5. Connect the Instrument (Mode ). . . . . . . . . . . . . . . . . . 36 3.5.1 Connect the Two-Wire Signal Cable . . . . . . . . . . . . . . . . . . . . . 36 3.5.2 Sample Sequencer Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 3.5.3 Sample Sequencer Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 3.5.4 Firmware Settings (Mode ) . . . . . . . . . . . . . . . . . . . . 40 3.6. Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 3.7. Connection Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.8. Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 3.9. Communication, Error Handling . . . . . . . . . . . . . . . . . . . . . . . . . . 44 3.9.1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 3.9.2 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 4. Instrument Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 4.1. Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

A-96.250.661 / 120418

AMI Sample Sequencer 5. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.1. Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.2. Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 5.3. Software Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.4. Changing Parameters or Values. . . . . . . . . . . . . . . . . . . . . . . . . . 49 6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 6.1. Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 6.2. Stop of Operation for Maintenance. . . . . . . . . . . . . . . . . . . . . . . . 50 6.3. Tube connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 6.4. Replacing Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 6.5. Longer Stop of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 7. Error List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 8. Program Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 8.1. Messages (Main Menu 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 8.2. Diagnostics (Main Menu 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 8.3. Maintenance (Main Menu 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 8.4. Operation (Main Menu 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 8.5. Installation (Main Menu 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 9. Program List and Explanations. . . . . . . . . . . . . . . . . . . . . . . . . 58 1 Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 2 Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 10. Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 11. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12. Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

AMI Sample Sequencer

Safety Instructions A-96.250.661 / 120418 3 AMI Sample Sequencer - Operator’s Manual This document describes the main steps for instrument setup, oper- ation and maintenance. 1. Safety Instructions General The instructions included in this section explain the potential risks associated with instrument operation and provide important safety practices designed to minimize these risks. If you carefully follow the information contained in this section, you can protect yourself from hazards and create a safer work environ- ment. More safety instructions are given throughout this manual, at the respective locations where observation is most important. Strictly follow all safety instructions in this publication. Target audience Operator: Qualified person who uses the equipment for its intended purpose. Instrument operation requires thorough knowledge of applications, instrument functions and software program as well as all applicable safety rules and regulations. OM Location The AMI Operator’s Manual shall be kept in proximity of the instru- ment. Qualification, Training To be qualified for instrument installation and operation, you must:  read and understand the instructions in this manual as well as the Material Safety Data Sheets.  know the relevant safety rules and regulations.

A-96.250.661 / 120418

AMI Sample Sequencer Safety Instructions 1.1. Warning Notices The symbols used for safety-related notices have the following sig- nificance: DANGER Severe injuries or death will result if such warnings are ignored.  Follow the prevention instructions carefully. WARNING Severe injuries or damage to the equipment can occur if such warnings are ignored.  Follow the prevention instructions carefully. CAUTION Damage to the equipment, minor injury, malfunctions or incor- rect process can be the consequence if such warnings are ig- nored.  Follow the prevention instructions carefully. Mandatory Signs The importance of the mandatory signs in this manual. Safety goggles Safety gloves

AMI Sample Sequencer

Safety Instructions A-96.250.661 / 120418 5 Warning Signs The importance of the warning signs in this manual. Electrical shock hazard Corrosive Harmful to health Flammable Warning general Attention general

A-96.250.661 / 120418

AMI Sample Sequencer Safety Instructions 1.2. General Safety Regulations Legal Requirements The user is responsible for proper system operation. All precautions must be followed to ensure safe operation of the instrument. Spare Parts and Disposables Use only official SWAN spare parts and disposables. If other parts are used during the normal warranty period, the manufacturer’s warranty is voided. Modifications Modifications and instrument upgrades shall only be carried out by an authorized Service Technician. SWAN will not accept responsi- bility for any claim resulting from unauthorized modification or alter- ation. WARNING Electrical Shock Hazard If proper operation is no longer possible, the instrument must be disconnected from all power lines, and measures must be taken to prevent inadvertent operation.  To prevent from electrical shock, always make sure that the ground wire is connected.  Service shall be performed by authorized personnel only.  Whenever electronic service is required, disconnect instru- ment power and power of devices connected to. – relay 1, – relay 2, – alarm relay WARNING For safe instrument installation and operation you must read and understand the instructions in this manual. WARNING Only SWAN trained and authorized personnel shall perform the tasks described in this document.

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 7 2. Product Description Application Range The AMI Sample Sequencer is a complete system for the automat- ic, continuous multiplexing of up to six sample streams to one pro- cess analyzer. The AMI Sample Sequencer can be connected to an:  AMI Phosphate HL  AMI Silica  AMI Silitrace  AMI Sodium A  AMI Sodium P Operating Modes The AMI Sample Sequencer provides the following two operating modes  AMI Set the AMI Sample Sequencer to the mode if it is con- nected to an AMI Phosphate HL, AMI Silica or AMI Silitrace. In this operating mode the AMI Sample Sequencer works as slave, either of the analyzer or of an external PLC. Communi- cation between the instruments takes place via I2C interface. For further information see Connect the I2C Bus, p. 31.  Internal Set the AMI Sample Sequencer to the mode if it is connected to an AMI Sodium A or AMI Sodium P. In this oper- ating mode the AMI Sample Sequencer works as master. It switches the sample streams according to the programmed cycle time. There is no communication between the instru- ments, only measuring values are transferred via signal out- puts 1 and 2 of the analyzer to the signal inputs 1 and 2 of the AMI Sample Sequencer. For further information see Sample Sequencer Inputs, p. 37. Signal Outputs 6 current outputs to transfer the measuring values of the AMI trans- mitter to a PLC device. Relay 6 signal outputs for indication of the 6-way valve position. 1 signal output for flow alarm. Inputs 6 signal inputs to override programmed measuring sequences, by activating or deactivating an input. The functionality depends on the settings of the instruments.

A-96.250.661 / 120418

AMI Sample Sequencer Product Description Safety Features No data loss after power failure. All data is saved in non-volatile memory. Over voltage protection of in- and outputs. Galvanic sepa- ration of measuring inputs and signal outputs. Fluidics The sample enters the flow cell blocks [C, D, E] via the sample in- lets [I]. Each sample inlet is equipped with a flow regulating valve [G]. The sample flows through the active sample line via 6-way valve [A] and flow meter [F] to the instrument. Excessive sample (e.g. inactive sample lines) flows via overflow [H] to the atmospher- ic drain [J]. A B C D 6-way valve Sample outlet Flow cell block with sample inlet 1 and 2 Flow cell block with sample inlet 3 and 4 E F G H I J Flow cell block with sample inlet 5 and 6 Flow meter Flow regulating valve Overflow Sample inlets 1–6 Atmospheric drain 1 I I I I I I 3 4 5 7 6 2 A B C G H H H J J J G G G G G D E F

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 9 2.1. Measuring Cycle at Batch Measurement 2.1.1 AMI Silica and AMI Phosphate HL Example with two sample streams: A measuring cycle always starts when the solenoid valve [C] clos- es. NOTICE: • The different squares, black with/without underline and white with/without underline are displayed on the display of the AMI Sample Sequencer, for better understanding they are integrated in the illustrations below. • The meaning of the different squares is explained in chapter 5, Operation. Step 1 The solenoid valve [C] is open.  The 6-way valve [A] is on position 1 and the sample stream 1 flows via constant head [B] through the photometer [D]. No measurement is performed at this time. A B 6-way valve Constant head C D Solenoid valve Photometer 1 1 2 3 4 5 6 3 4 5 7 6 2 A B C D

A-96.250.661 / 120418

AMI Sample Sequencer Product Description Step 2 The solenoid valve [C] closes:  at the same time the 6-way valve [A] switches to sample stream 2, a new measuring cycle starts.  the sample of sample stream 1 remains in the photometer where reagents are added and a measurement is performed.  During the measuring of sample stream 1, the tube [E] and the constant head [B] are flushed with sample stream 2. A B C 6-way valve Constant head Solenoid valve D E Photometer Sample inlet constant head 1 1 2 3 4 5 6 3 4 5 7 6 2 A B C D E

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 11 Step 3 The measurement of sample 1 is finished.  The solenoid valve [C] is open and the photometer is flushed with sample stream 2.  A valid measuring value of sample stream 1 is available. A B C 6-way valve Constant head Solenoid valve D E Photometer Sample inlet constant head 1 1 2 3 4 5 6 3 4 5 7 6 2 A B C D E

A-96.250.661 / 120418

AMI Sample Sequencer Product Description 2.2. Measuring Cycle at Continuous Measurement 2.2.1 AMI Sodium A and AMI Sodium P A new measuring cycle always starts when the 6-way valve [A] is switched to the next programmed sample stream. NOTICE: The following parameters are only available if the AMI Sample Sequencer is set to the mode . Cycle time The time of switch over between the sample streams is defined as -cycle time-. The cycle time includes the “Flush Time” and the mea- suring time of the active sample line. The measuring time can not be set, but can be calculated as fol- lows: Measuring time = “Cycle Time” - “Flush Time” + “Valid After” The -cycle time- can be set individually for each sample line in 5 min steps from 5 min to 600 min. A sample line is deactivated if the cycle time is set to 0 min. Flush Time The parameter -Flush Time- defines how long the measuring cell of the AMI Sodium A or an AMI Sodium P is flushed with the active sample before the measurement starts. (see 5.1 Sequence, p. 60) Valid After The parameter -Valid After- defines the remaining measuring time of the sample stream x after the 6-way valve has switched to the next sample stream (see 5.1 Sequence, p. 60). A B C D E Sample stream 1 on hold Sample stream 2 on hold Sample stream 1, high conc. Sample stream 2, low conc. Measuring signal F G H I Cycle time Flush time Measuring time Valid after ppb Time 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 G I G I H C D E F H I G H I A B

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 13 Example with two sample streams: NOTICE: • The different squares, black with/without underline and white with/without underline are displayed on the display of the AMI Sample Sequencer, for better understanding they are integrated in the illustrations below. • The meaning of the different squares is explained in chapter 5, Operation. Step 1  The 6-way valve [A] is on position 1 and sample stream 1 [D] flows via constant head [B] through the measuring cell [C] where the sodium concentration is continuously measured. A B 6-way valve Constant head C D Measuring cell Sample 1 1 1 2 3 4 5 6 3 4 5 7 6 2 A B C D

A-96.250.661 / 120418

AMI Sample Sequencer Product Description Step 2  The 6-way valve [A] has switched to sample stream 2 – The -Valid after- time [I] is active. The instrument still measures channel 1. – The -Flush time- [G] is active. No valid measuring value is available for channel 2 yet. A B C 6-way valve Constant head Measuring cell D E Sample 1 Mixing zone Sample 1 and 2 1 1 2 3 4 5 6 3 4 5 7 6 2 B A E D C

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 15 Step 3  The -Valid after- time is finished: – Sample stream 2 is selected and measured. A B 6-way valve Constant head C D Measuring cell Sample 2 1 1 2 3 4 5 6 3 4 5 7 6 2 B A D C

A-96.250.661 / 120418

AMI Sample Sequencer Product Description 2.2.2 AMI Silitrace The switch to the next channel is initiated by the AMI analyzer ac- cording to the programmed switching time. Example with two sample streams, switching time set to 30 min: NOTICE: • The different squares, black with/without underline and white with/without underline are displayed on the display of the AMI Sample Sequencer, for better understanding they are integrated in the illustrations below. • The meaning of the different squares is explained in chapter 5, Operation. Step 1  The 6-way valve [B] is on position 1 and sample stream 1 flows through the flow cell block [D]. From there, it is pumped to the photometer by the peristaltic pump [C]. A B Photometer 6-way valve C D Peristaltic pump Flow cell block 1 1 2 3 4 5 3 4 5 7 6 2 B C A D

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 17 Step 2a  The 6-way valve [B] has switched to sample stream 2: – The instrument still measures sample 1 – Channel 2 is selected but not yet measured A B C Photometer 6-way valve Peristaltic pump D E Sample 1 Mixing zone Sample 1 and 2 1 1 2 3 4 5 6 3 4 5 7 6 2 B C A E D

A-96.250.661 / 120418

AMI Sample Sequencer Product Description Step 2b  The mixing zone [E] flows through the photometer [A] – No valid measuring value is available. A B C Photometer 6-way valve Peristaltic pump D E Sample 1 Mixing zone Sample 1 and 2 1 1 2 3 4 5 6 3 4 5 7 6 2 B C A E D

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 19 Step 3  The instrument has finished flushing the photometer with sample stream 2. – Sample stream 2 is selected and measured. A B Photometer 6-way valve C D Peristaltic pump Flow cell block 1 1 2 3 4 5 6 3 4 5 7 6 2 B C A D

A-96.250.661 / 120418

AMI Sample Sequencer Product Description 2.3. Instrument Specification Power supply Available as an AC or DC model. Voltage: 100–240 VAC (± 10%) 50/60 Hz (± 5%) or 24 VDC (± 10%) Power consumption: max. 8 VA Sample requirements Flow rate: according to the attached analyzer plus min. 5 l/h per stream Sample pressure inlet: 0.5–3 bar (2–43 PSI) Sample temperature: 5–45 °C (41–122 °F) NOTICE: The sample must not contain any oil, grease, or sand. On-site requirements The analyzer site must permit connections to: Sample inlet (6): Tube 4 x 6 mm Sample outlet (1): Tube 4 x 6 mm Sample overflow (3): each 15 x 20 mm (1/2” hose nozzle) Outlet pressure: atmospheric. Electronics housing Aluminum with a protection degree of IP 66 / NEMA 4X Ambient temperature: -10 to +50 °C Limit range of operation: -25 to +65 °C Storage and transport: -30 to +85 °C Humidity.: 10 to 90 % relative, non condensing Display: backlit LCD, 75 mm x 45 mm

AMI Sample Sequencer

Product Description A-96.250.661 / 120418 21 Dimensions Dimensions: 280 x 850 x200 mm Distance between mounting holes: 254 x 824 mm Screws: 8 mm diam. Panel material: Stainless steel Weight: 8 kg AMI Sample Sequencer Exit Enter 824 mm / 32 7/16” 850 mm / 33½” 13 mm 254 mm / 10” 280 mm / 11” 13 mm 4x dia. 10 mm

A-96.250.661 / 120418

AMI Sample Sequencer Product Description 2.4. Instrument Overview A B C D E F AMI Transmitter Panel 6-way valve control unit 6-way valve Flow cell block sample stream 1 and 2 Flow cell block sample stream 3 and 4 G H I J K Flow cell block sample stream 5 and 6 Flow meter Sample outlet Sample inlet 1 to 6 Hose nozzles for waste connection D E F G H I J K C B A

AMI Sample Sequencer

Installation A-96.250.661 / 120418 23 3. Installation 3.1. Installation Check List Check Instrument’s specification must conform to your power ratings. Do not turn on power until instructed to do so. On-site requirements  AC model: 100–240 VAC (10%), 50/60 Hz (5%), DC model: 24 VDC (±10%)  isolated power outlet with ground connection and 8 VA  Sample line with min. 5 l/h and 0.5–3 bar  Waste line with atmospheric drain Installation  Install the AMI Sample Sequencer, p. 24  Connect Sample and Waste, p. 25  Install the connection tube to the AMI analyzer  Replace the flow regulating valve of the AMI analyzer with a blind plug Electrical Wiring  Connect the AMI analyzer to the AMI Sample Sequencer  Connect the AMI Sample Sequencer to the mains; do not switch on power yet! See Power Supply, p. 43 Power-up Perform exactly in this order: – Turn on the sample flow. See Instrument Setup, p. 45 – Adjust the sample flow on all connected sample inlets of the sample sequencer – Switch on power. See Instrument Setup, p. 45 Instrument Setup Program all parameters for operation (sequence, alarms).

A-96.250.661 / 120418

AMI Sample Sequencer Installation 3.2. Install the AMI Sample Sequencer The first part of this chapter describes the preparing and placing of the system for use.  The analyzer must only be installed by trained personnel.  Mount the instrument in vertical position.  For ease of operation mount it so that the display is at eye level.  For the installation a kit containing the following installation material is available: – 4 Screws 8x60 mm – 4 Dowels – 4 Washers 8.4/24 mm Mounting re- quirements The instrument is only intended for indoor installation. For dimensions see picture Dimensions, p. 21.

AMI Sample Sequencer

Installation A-96.250.661 / 120418 25 3.3. Connect Sample and Waste Sample inlet Use plastic tube (FEP, PA, or PE 4 x 6 mm) to connect the sample line. Mounting of SERTO fitting Waste Connect the 1/2” tubes to the nozzle of the waste funnels and place them into an atmospheric drain of sufficient capacity. A B C D Screw connection Compression ferrule Knurled nut Flexible tube B C D A A B C Flow cell blocks sample inlet 1 to 6) Hose nozzles 1/2” Tube to atmospheric drain 1 2 3 4 5 6 A A A B B B C C C

A-96.250.661 / 120418

AMI Sample Sequencer Installation Connecting example with AMI Silica A B C Sample inlet 1 to 6 Hose nozzles for waste connection Sample outlet of AMI Sample Sequencer D E F G Connection tube Blind plug Flow regulating valve Sample inlet of AMI Silica Exit Enter Exit Enter 1 2 3 4 5 6 Level 2L 2L 2L 2L OXYCON ON-LINE SILCA AMI SILICA REAGENT 1 OXYCON ON-LINE SILCA AMI SILICA REAGENT 2 OXYCON ON-LINE SILCA AMI SILICA REAGENT 3 OXYCON ON-LINE SILCA AMI SILICA REAGENT 4 A B C D E F G

AMI Sample Sequencer

Installation A-96.250.661 / 120418 27 Connecting example with AMI Silitrace A B C Sample inlet 1 to 6 Hose nozzles for waste connection Sample outlet of AMI Sample Sequencer D E F G Connection tube Sample inlet of AMI Silitrace Flow regulating valve Blind plug Exit Enter 1 2 3 4 5 6 2L 2L 2L OXYCON ON-LINE SILCA AMI SILICA REAGENT 1 OXYCON ON-LINE SILCA AMI SILICA REAGENT 2 OXYCON ON-LINE SILCA AMI SILICA REAGENT 3 OXYCON ON-LINE SILCA AMI SILICA REAGENT 4 2L Exit Enter A B C D E F G

A-96.250.661 / 120418

AMI Sample Sequencer Installation Connecting example with AMI Phosphate HL A B C Sample inlet 1 to 6 Hose nozzles for waste connection Sample outlet of AMI Sample Sequencer D E F G Connection tube Blind plug Flow regulating valve Sample inlet of AMI Phosphate HL Exit Enter Exit Enter 1 2 3 4 5 6 2L OXYCON ON-LINE KI-Lösung KI-Solution Level A B C D E F G

AMI Sample Sequencer

Installation A-96.250.661 / 120418 29 Connecting example with AMI Sodium A / P A B C Sample inlet 1 to 6 Hose nozzles for waste connection Sample outlet of AMI Sample Sequencer D E F G Connection tube Blind plug Flow regulating valve Sample Inlet of AMI Sodium Exit Enter 1 2 3 4 5 6 Exit Enter A B C D F E G

A-96.250.661 / 120418

AMI Sample Sequencer Installation Sample Connection Examples see  Connecting example with AMI Silica, p. 26  Connecting example with AMI Silitrace, p. 27  Connecting example with AMI Phosphate HL, p. 28  Connecting example with AMI Sodium A / P, p. 29 To connect the AMI Sample Sequencer to an AMI analyzer proceed as follows: 1 Connect the 1/2” tubes to the hose nozzles [B] and put them into an atmospheric drain. 2 Connect the sample streams 1 to 6 to the sample inlets 1 to 6 [A] of the AMI Sample Sequencer. 3 Replace the flow regulating valve [F] at the flow cell block of the AMI analyzer with the blind plug [E]. 4 Connect the connecting tube [D] from the sample outlet of the AMI Sample Sequencer [C] to the sample inlet of the AMI ana- lyzer [G]. 5 Adjust sample flow, see Instrument Setup, p. 45. 6 Set the firmware according to chapter  Firmware Settings (Mode ), p. 40 or  Firmware Settings (Mode ), p. 35.

AMI Sample Sequencer

Installation A-96.250.661 / 120418 31 3.4. Connect the Instrument (Mode ) The following instruction applies for the:  AMI Silica  AMI Silitrace  AMI Phosphate HL hereinafter referred to as AMI analyzer. 3.4.1 Connect the I2C Bus The AMI analyzers listed above require an I2C bus connection, which allows communication between the two instruments. WARNING Risk of electrical shock Do not perform any work on electrical components if the trans- mitter is switched on. Failure to follow safety instructions could result in serious injury or death.  Stop sample flow.  Shut off power of the analyzer. Connect the AMI analyzer and the Sample Sequencer as follows: 1 Switch off the Instrument. 2 Open the transmitter cover. 3 Feed one cable end through a PG 7 cable gland into the trans- mitter housing of the AMI analyzer and the other one into the transmitter housing of the Sample Sequencer. 4 Connect the cable to the plugs according to the following table. NOTICE: Due to technical reasons the data signal wires green and white of the I2C bus need to be connected to the plug in inverse order if the transmitter of the AMI analyzer is equipped with main board V2.4.

A-96.250.661 / 120418

AMI Sample Sequencer Installation 5 Insert the plugs into the sockets on the main boards according the picture below. AMI analyzer with 2nd Sample Stream Option If an AMI analyzer is already equipped with a 2nd Sample Stream option the 2nd Sample Stream option is deactivated if an AMI Sam- ple Sequencer is connected to the AMI analyzer and the solenoid valve is switched to the sample inlet 1. NOTICE: Generally SWAN does not recommend to connect an AMI Sample Sequencer to an AMI analyzer equipped with a 2nd Sample Stream option. If it is not possible to remove the 2nd Sample Stream option for any reasons, proceed according to Sample Connection, p. 30 steps 1 to 3 then:  Close the flow regulating valve of the sample inlet 2.  Connect the connecting tube [D] from the sample outlet [C] of the AMI Sample Sequencer to the sample inlet 1 of the 2nd Sample Stream option.  Then continue to Sample Connection, p. 30 with step 5. Terminal Number Plug Plug AMI Analyzer Wire Color AMI Sample Sequencer Main board V2.3 Main board V2.4 Main board V2.5 green 1 1 2 1 white 2 2 1 2 brown 3 3 3 3 black 4 4 4 4 A Plug AMI Sample Sequencer B Plug AMI analyzer A B

AMI Sample Sequencer

Installation A-96.250.661 / 120418 33 3.4.2 Sample Sequencer Inputs Unused signal inputs: The following signal inputs of the AMI Sample Sequencer are not applicable if an AMI analyzer is connected: Signal inputs from PLC device: Each sample stream is assigned to an input channel of the AMI Sample Sequencer. The sample stream number corresponds with the channel number. The functionality of the inputs depends on the settings of the Mode of the AMI analyzer. Mode Internal If the AMI analyzer is set to Mode Internal, the programmed num- ber of sample streams is sequentially measured. Any sample inlet can be deactivated by closing one or more of the contacts 9 to 14 (6 inputs from PLC) via a PLC. In the example below, the channels highlighted in red will not be measured. NOTICE: If all contacts are closed, the AMI analyzer switches to standby mode. Terminals Signal 23/25 Mark end of measurement 27/29 System Alarm 34/32 Signal Input 1 31/32 Signal Input 2 CH1 SEQUENCER Processor CH2 CH3 CH4 CH5 6 Inputs from PLC 1 mA sink, 5 V open CH6 GND 9 10 11 12 13 14 15

A-96.250.661 / 120418

AMI Sample Sequencer Installation Mode External If the AMI analyzer is set to mode external, each sample stream to be measured has to be activated by closing the respective contact. In the example below, the sample stream 3 (CH3) highlighted in green will be measured as soon as the AMI analyzer has finished the previous measurement. NOTICE: • Closing more than one of the inputs will cause an undefined state. • If all inputs are open the AMI analyzer switches to standby mode. Connect the signal inputs according to the connection diagram. Mode Fieldbus The same function as External but using Profibus or Modbus proto- col. Further information concerning see Manual of the corresponding AMI analyzer. NOTICE: The AMI Sample Sequencer can not be connected to a Profibus or Modbus system. Install the Profibus or Modbus interface on the AMI analyzer. CH1 SEQUENCER Processor CH2 CH3 CH4 CH5 6 Inputs from PLC CH6 GND 9 10 11 12 13 14 15 1 mA sink, 5 V open

AMI Sample Sequencer

Installation A-96.250.661 / 120418 35 3.4.3 Sample Sequencer Outputs Current outputs The current outputs 17 to 22 can be used to display the measuring values on a remote location. Each sample stream is assigned to an output channel on the termi- nal of the AMI Sample Sequencer. The sample stream number cor- responds with the channel number. NOTICE: Max. burden: 510 Ω. If signals are sent to two different receivers, use signal isolator (loop isolator). Signal outputs 1 to 6 to PLC The Outputs 1 to 6 to a PLC are used to transfer the current posi- tion of the AMI Sample Sequencer’s 6-way valve to a PLC. The PLC needs this information to:  control the measuring cycles if the AMI analyzer is set to ex- ternal Mode.  assign the current outputs of the AMI analyzer to the mea- sured sample stream. 3.4.4 Firmware Settings (Mode ) AMI Sample Sequencer In menu 5.1.1 set Mode to , further information see chapter 9 Program List and Explanations, p. 58, Section 5.1 Sequence, p. 60. AMI Analyzer If the AMI Sample Sequencer is connected correctly, it is recog- nized automatically by the firmware of the AMI analyzer. Set the Firmware:  In menu 5 // program the number of samples you have connected to the AMI Sam- ple Sequencer.  In menu 5 // set the Channel Selection to: – Internal – External – Fieldbus Further information about settings of AMI analyzer can be found in the corresponding manual.

A-96.250.661 / 120418

AMI Sample Sequencer Installation 3.5. Connect the Instrument (Mode ) The following instruction applies for the:  AMI Sodium A  AMI Sodium P hereinafter referred to as AMI analyzer. 3.5.1 Connect the Two-Wire Signal Cable The instruments listed above do not need any communication with the AMI Sample Sequencer, therefore they are connected to the AMI Sample Sequencer via a two wire signal cable from the signal outputs of the AMI analyzer to the signal inputs of the AMI Sample Sequencer. NOTICE: If an AMI analyzer is already equipped with a 2nd Sample Stream option, it is not possible to operate it with an AMI Sample Sequencer. Before connecting an AMI Sample Sequencer remove the 2nd Sample Stream option. WARNING Risk of electrical shock Do not perform any work on electrical components if the trans- mitter is switched on. Failure to follow safety instructions could result in serious injury or death.  Stop sample flow.  Shut off power of the analyzer. 1 Feed one cable end through a PG 7 cable gland into the trans- mitter housing of the AMI analyzer and the other one into the transmitter housing of the AMI Sample Sequencer. 2 Connect the cable to the terminals for signal output 1 and 2 of the AMI analyzer according to the Connection Diagram, p. 42. 3 Connect the cable to the terminals for signal input 1 and 2 of the AMI Sample Sequencer according to the Connection Diagram, p. 42.

AMI Sample Sequencer

Installation A-96.250.661 / 120418 37 3.5.2 Sample Sequencer Inputs Signal inputs from AMI analyzer The values of the AMI analyzer are transferred via signal output 1 and 2 to the AMI Sample Sequencers signal inputs 1 and 2. From there the measuring values can be transferred and displayed at a remote location. Connect the signal inputs according to the table below. Signal inputs from External Devices Signal inputs from PLC device Each sample stream is assigned to an input channel of the AMI Sample Sequencer. The sample stream number corresponds with the channel number. If a PLC device is connected to the signal inputs 9 to 14 any sample stream can be switched off or on by the PLC device. 3.5.3 Sample Sequencer Outputs Current Out- puts The current outputs 17 to 22 can be used to display the measuring values on a remote location. The assignment of the terminals to the sample streams depends on the selected parameter  Signal Inputs = 1  Signal Inputs = 2 (only up to 3 sample streams) in the menu , of the AMI Sample Sequencer. NOTICE: Max. burden: 510 Ω. If signals are sent to two different receivers, use signal isolator (loop isolator). Terminals Signal Use 34/32 Signal Input 1 Measuring value 1 31/32 Signal Input 2 Measuring value 2 Terminals Signal Use 23/25 Mark end of measurement Not applicable 27/29 System Alarm Flow alarm

A-96.250.661 / 120418

AMI Sample Sequencer Installation If Signal Inputs = 1 If Signal Inputs = 1 is selected, 6 sample streams can be mea- sured. 1 signal (measuring value) can be transmitted from the transmitter of the AMI analyzer to the transmitter of the sample se- quencer. The signal outputs are connected to the terminals according the ta- ble below. If Signal Inputs = 2 If Signal Inputs = 2 is selected, 3 sample streams can be mea- sured. 2 signals (e.g. measuring value and temperature) can be transmitted from the transmitter of the analyzer to the transmitter of the sample sequencer. The signal outputs are connected to the terminals according the fol- lowing table: Channel Terminals for Signal 1 CH 1 22/16 CH 2 21/16 CH 3 20/16 CH 4 19/16 CH 5 18/16 CH 6 17/16 CH1 SEQUENCER A/D SIG 1 IN SIG 2 IN CH2 CH3 CH4 CH5 CH6 RTN 22 21 20 19 18 17 16 34 32 31 Channel Terminals for Signal 1 Terminals for Signal 2 CH 1 22/16 19/16 CH 2 21/16 18/16 CH 3 20/16 17/16 CH1 22 34 32 31 21 20 19 18 17 16 SEQUENCER A/D SIG 1 IN SIG 2 IN CH2 CH3 CH1 CH2 CH3 RTN

AMI Sample Sequencer

Installation A-96.250.661 / 120418 39 Deactivate channels If signal inputs = 1: In the example below, the channels highlighted in red will not be measured. NOTICE: If all contacts are closed, the AMI analyzer remains in stand by mode. Deactivate channels If signal inputs = 2: In the example below, the channel highlighted in red will not be measured. NOTICE: If all contacts are closed, the AMI analyzer remains in stand by mode. CH1 SEQUENCER Processor CH2 CH3 CH4 CH5 6 Inputs from PLC 1 mA sink, 5 V open CH6 GND 9 10 11 12 13 14 15 CH1 SEQUENCER Processor CH2 CH3 CH4 CH5 6 Inputs from PLC CH6 GND 9 10 11 12 13 14 15 1 mA sink, 5 V open

A-96.250.661 / 120418

AMI Sample Sequencer Installation Signal outputs 1 to 6 to PLC The Outputs 1 to 6 to a PLC are used to transfer the current posi- tion of the AMI Sample Sequencer’s 6-way valve. 3.5.4 Firmware Settings (Mode ) AMI Sample Sequencer In menu 5.1.1 set Mode to , further information see chapter 9 Program List and Ex- planations, p. 58, Section 5.1 Sequence, p. 60. In menu 5.1.2 Signal Inputs can be set to:  1 or  2 Further information see Current Outputs, p. 37. AMI analyzer No firmware settings necessary.

AMI Sample Sequencer

Installation A-96.250.661 / 120418 41 3.6. Electrical Connections WARNING Risk of electrical shock. Do not perform any work on electrical components if the trans- mitter is switched on. Failure to follow safety instructions could result in serious injury or death.  Always turn off AC power before manipulating electric parts.  Grounding requirements: Only operate the instrument from an power outlet which has a ground connection.  Make sure the power specification of the instrument corre- sponds to the power on site. Cable thicknesses In order to comply with IP66, use the following cable thicknesses NOTICE: Protect unused cable glands Wire  For Power and Relays: Use max. 1.5 mm2 / AWG 14 stranded wire with end sleeves.  For Signal Outputs and Input: Use 0.25 mm2 / AWG 23 stranded wire with end sleeves. A B C PG 11 cable gland: cable Øouter 5–10 mm PG 7 cable gland: cable Øouter 3–6.5 mm PG 9 cable gland: cable Øouter 4–8 mm A B C

A-96.250.661 / 120418

AMI Sample Sequencer Installation 3.7. Connection Diagram CAUTION Use only the terminals shown in this diagram, and only for the mentioned purpose. Use of any other terminals will cause short circuits with possible corresponding consequences to material and personnel.

AMI Sample Sequencer

Installation A-96.250.661 / 120418 43 3.8. Power Supply WARNING Risk of electrical shock Do not perform any work on electrical components if the trans- mitter is switched on. Failure to follow safety instructions could result in serious injury or death.  Always turn off AC power before manipulating electric parts.  Installation and maintenance of electrical parts must be per- formed by professionals NOTICE: The protective earth wire (Ground) has to be connected to the grounding terminal. Installation requirements The installation must meet the following requirements.  Fuse 1 AT  Mains cable to comply with standards IEC 60227 or IEC 60245; flammable rating FV1  Mains equipped with an external switch or circuit-breaker – near the analyzer – easily accessible to the operator – marked as interrupter for AMI Sample Sequencer A B C D Power supply connector Neutral conductor, Terminal 2 Phase conductor, Terminal 1 Protective earth PE C A B D

A-96.250.661 / 120418

AMI Sample Sequencer Installation 3.9. Communication, Error Handling 3.9.1 Mode The I2C connection allows a communication between the AMI ana- lyzer and the AMI Sample Sequencer. Sample Switch Command The AMI analyzer sends a command to the AMI Sample Sequencer to switch the 6-way valve to the next sample stream. Sample Flow Error in Mode Internal If the Sample Sequencer detects a flow error on a sample stream, it immediately switches to the next sample stream until it finds a sam- ple stream with sample flow. The flow error is indicated on the re- spective sample stream on the AMI analyzer display with a tilde. During this time the AMI analyzer detects sample flow from the con- stant head, therefore no flow alarm is triggered. Sample Flow Error in Mode External If the Sample Sequencer detects a flow error on a sample stream, it is waiting for the command to switch to the next sample stream. A flow alarm is issued via relay contact 7 “ALARM” of the outputs to PLC. 3.9.2 Mode The signal outputs 1 and 2 of the AMI analyzer can be connected to the signal inputs 1 and 2 of the AMI Sample Sequencer. This allows to transfer the measuring values of each measured sample stream to a remote device. There is no communication between the AMI analyzer and the AMI Sample Sequencer! Sample Switch Command The command to switch to the next channel is triggered by the AMI Sample Sequencer according to its programmed cycle time. Sample Flow Error If the Sample Sequencer detects a flow error on a sample stream it remains on this sample stream until the cycle time is over. During this time it displays a flow alarm.

AMI Sample Sequencer

Instrument Setup A-96.250.661 / 120418 45 4. Instrument Setup After the installation according to checklist has been finished, ad- just the sample flow. Without back pressure regulator 1 Open all main sample taps. 2 Open all flow regulating valves at the sample inlets of the AMI Sample Sequencer. 3 Adjust the sample flow of each sample inlet to min. 5 l/h. 4 Check all sample inlets for leakage. 5 If leakage occurs, stop sample flow and repair it. 6 Repeat step 1 to 4. 7 Switch on power. With back pressure regulator The SWAN Back Pressure Regulator is used to stabilize, reduce and control the flow rate of sample for water analyzing systems. If a back pressure regulator is installed adjust the sample flow as fol- lows: 1 Open all main sample taps. 2 Open all flow regulating valves at the sample inlets of the AMI Sample Sequencer. 3 Open the shut off valves on the back pressure regulators. 4 The sample flow of each sample inlet should be min. 5 l/h. 5 Check all sample inlets for leakage. 6 If leakage occurs, stop sample flow and repair it. 7 Repeat step 1 to 5. 8 Switch on power. 4.1. Programming Programming Program all parameters for instrument operation (sequence, alarms). See Program Overview, S. 55 and Program List and Ex- planations, S. 58.

A-96.250.661 / 120418

AMI Sample Sequencer Operation 5. Operation 5.1. Keys Program Access, Exit A Exit to exit a menu or command (rejecting any changes) to move back to the previous menu level B to move DOWN in a menu list and to decrease digits C to move UP in a menu list and to increase digits D Enter to open a selected sub-menu to accept an entry Exit Enter B C D A RUN 15:20:18 8.0 l/h 1 Installation Diagnostics Messages Maintenance Main Menu Enter Exit

AMI Sample Sequencer

Operation A-96.250.661 / 120418 47 5.2. Display A RUN normal operation HOLD AMI Sample Sequencer on hold B ERROR Error Fatal Error C Time D Sample Flow E Status of channels 1 to 6 Sample line inactive Sample line active Underlined square: Last valid measurement RUN 15:20:18 8.0 l/h A B D E C

A-96.250.661 / 120418

AMI Sample Sequencer Operation 5.3. Software Structure The menu structure depends on the settings of the AMI transmitter. Therefore the following examples are only applicable with certain configurations. Menu 1 Messages Reveals pending errors as well as an event history (time and state of events that have occurred at an earlier point of time). It contains user relevant data. Menu 2 Diagnostics Provides user relevant instrument and sample data. Menu 3 Maintenance For instrument calibration, relay and signal output simulation, and to set the instrument time. It is used by the service personnel. Menu 4 Operation Not applicable. Menu 5 Installation For initial instrument set up by SWAN authorized person, to set all instrument parameters. Can be protected by means of password. 1 Messages Maintenance Diagnostics Main Menu Installation 1.1 Pending Errors Messages Message List 2.1 Signal Outputs Identification Sensors Diagnostics 3.1 Signal Outputs Maintenance Set Time 01.01.05 16:30:00 Rotary Valve 5.1 Miscellaneous Sequence Sample Flow Installation

AMI Sample Sequencer

Operation A-96.250.661 / 120418 49 5.4. Changing Parameters or Values Changing parameters The following example shows how to change the cycle time: 1 Select the parameter you want to change. 2 Press . 3 Press [ ] or [ ] key to highlight the required parameter. 4 Press to confirm the se- lection or to keep the previ- ous parameter).  The selected parameter is indicated (but not saved yet). 5 Press .  Yes is highlighted. 6 Press to save the new pa- rameter.  The system reboots, the new parameter is set. 5.1.5.1 Cycle Time Channel 1 30 Mlin Channel 2 30 Min Channel 3 30 Min Channel 4 30 Min Channel 5 30 Min 5.1.5.1 Cycle Time Channel 2 30 Min Channel 3 30 Min Channel 4 30 Min Channel 5 30 Min Channel 1 15 Min 5.1.5.1 Cycle Time Channel 1l 15 Min Channel 2 30 Min Channel 3 30 Min Channel 4 30 Min Channel 5 30 Min 5.1.5.1 Cycle Time Channel 1 15 Min Channel 4 30 Min Channel 5 30 Min Channel 2 30 Min No Save ? Channel 3Yes 30 Min

A-96.250.661 / 120418

AMI Sample Sequencer Maintenance 6. Maintenance 6.1. Maintenance Schedule This Instrument does not require any maintenance. It is however recommended to check the sample flow daily. WARNING Stop operation before maintenance.  Stop sample flow.  Shut off power of the instrument. 6.2. Stop of Operation for Maintenance 1 Stop sample flow 2 Shut off power of the instrument. Monthly Check sample flow By occurrence Replace tubes Clean flow meter

AMI Sample Sequencer

Maintenance A-96.250.661 / 120418 51 6.3. Tube connections The connection tubes between the flow cell block outlet and the 6-way valve inlet are not numbered. If you replace the tubes make sure that the numbering of the flow cell block outlets corresponds to the numbering of the 6-way valve inlets. 1 1 2 3 4 5 6 3 4 5 7 6 2 A B

A-96.250.661 / 120418

AMI Sample Sequencer Maintenance 6.4. Replacing Fuses WARNING Risk of electrical shock Do not perform any work on electrical components if the trans- mitter is switched on. Failure to follow safety instructions could result in serious injury or death.  Disconnect the instrument from the mains before opening the cover. Find and repair the cause for the short circuit before replacing the fuse. Use tweezers or needle-nosed pliers to remove the defective fuse. Use original fuses provided by SWAN only. 6.5. Longer Stop of Operation 1 Stop sample flow. 2 Shut off power of the instrument. A 1 AT/250V Instrument power supply A

AMI Sample Sequencer

Error List A-96.250.661 / 120418 53 7. Error List Error Non-fatal Error. Indicates an alarm if a programmed value is ex- ceeded. Such Errors are marked E0xx (bold and black). Fatal Error (blinking symbol) The indicated measured values are possibly incorrect. Fatal Errors are divided in the following two categories:  Errors which disappear if correct measuring conditions are re- covered (e.g. Sample Flow low). Such Errors are marked E0xx (bold and orange)  Errors which indicate a hardware failure of the instrument. Such Errors are marked E0xx (bold and red) Error or fatal Error Error not yet acknowledged. Check Pending Errors 1.1.5 * and take corrective action. Press [ENTER]. Navigate to menu Messages. Press [ENTER]. Navigate to menu Pending Errors. Press [ENTER]. Press [ENTER] to acknowledge the Pending Errors. The Error is reset and saved in the Message List. RUN 15:20:18 0.0 l/h 1 Installation Diagnostics Messages Maintenance Main Menu 1.1 Pending Errors Message List Messages 1.1.5 Pending Errors Error Code E010 Sample Flow low to Acknowledge

A-96.250.661 / 120418

AMI Sample Sequencer Error List Error Description Corrective action E009 Sample Flow high – check Inlet pressure – readjust sample flow – check programmed value, see 5.2.1, p. 61 E010 Sample Flow low – check Inlet pressure – readjust sample flow – clean instrument – check programmed value, see 5.2.2, p. 61 E031 Calibration Recout – call service E049 Power-on – none, normal status E050 Power-down – none, normal status

AMI Sample Sequencer

Program Overview A-96.250.661 / 120418 55 8. Program Overview For explanations about each parameter of the menus see Program List and Explanations, S. 58.  Menu 1 Messages is always accessible for everybody. No password protection. No settings can be modified.  Menu 2 Diagnostics is always accessible for everybody. No password protection. No settings can be modified.  Menu 3 Maintenance is for service: Calibration, simulation of outputs and set time/date. Please protect with password.  Menu 4 Operation not applicable.  Menu 5 Installation: Defining operating parameters. Menu for the system engineer. Password strongly recommended. 8.1. Messages (Main Menu 1) Pending Errors Pending Errors 1.1.5* * Menu numbers 1.1* Message List Number 1.2.1* 1.2* Date, Time

A-96.250.661 / 120418

AMI Sample Sequencer Program Overview 8.2. Diagnostics (Main Menu 2) 8.3. Maintenance (Main Menu 3) 8.4. Operation (Main Menu 4) Not applicable Identification Designation AMI Sequencer * Menu numbers 2.1* Version V5.00 - 12/16 Version ROVALVE 1.50 Factory Test Instrument 2.1.4.1 2.1.4* Motherboard Operating Time Years / Days / Hours / Minutes / Seconds 2.1.5.1* 2.1.5* Sensors Miscellaneous Case Temp. 2.2.1.1* 2.2* 2.2.1 Signal Outputs Signal Output 1–6 2.3.1* 2.3* Signal Inputs Signal Input 1 2.4.1* 2.4 Signal Input 2 Signal Outputs Signal Output 1–6 3.1.1 * Menu numbers 3.1* 3.1.1* Rotary Valve 3.2* Set Time (Date), (Time) 3.5*

AMI Sample Sequencer

Program Overview A-96.250.661 / 120418 57 8.5. Installation (Main Menu 5) Sequence Mode 5.1.1* * Menu numbers 5.1* Signal Inputs 5.1.2* only at continuous measurement Flush Time 5.1.3* only at continuous measurement Valid After 5.1.4* only at continuous measurement Cycle Time Channel 1–6 only at continuous measurement 5.1.5 Sample Flow Alarm High 5.2.1* 5.2* Alarm Low 5.2.2* Hysteresis 5.2.3* Delay 5.2.4* Miscellaneous Language 5.3.1* 5.3* Set defaults 5.3.2* Load Firmware 5.3.3* Password Messages 5.3.4.1* 5.3.4* Maintenance 5.3.4.2* Operation 5.3.4.3* Installation 5.3.4.4*

A-96.250.661 / 120418

AMI Sample Sequencer Program List and Explanations 9. Program List and Explanations 1 Messages 1.1 Pending Errors 1.1.5 Provides the list of active errors with their status (active, acknowl- edged). If an active error is acknowledged, the alarm relay opens again. Cleared errors are moved to the Message list. 1.2 Message List 1.2.1 Shows the error history: Error code, date / time of issue and status (active, acknowledged, cleared). 65 errors are memorized. Then the oldest error is cleared to save the newest error (circular buffer). 2 Diagnostics In diagnostics mode, the values can only be viewed, not modified. 2.1 Identification Designation: View the Designation of instrument. Version: Firmware of instrument (e.g. V5.00-12/16) Version: ROVALVE 1.50 2.1.4 Factory Test: Test date of the Instrument and Motherboard. 2.1.5 Operating Time: Years / Days / Hours / Minutes / Seconds 2.2 Sensors 2.2.1 Miscellaneous: 2.2.1.1 Case Temp: Shows actual temperature in [°C] inside the transmit- ter. 2.3 Signal Outputs 2.3.1 Signal Output 1 to 6: Review the actual measured value in mA. 2.4 Signal Inputs 2.4.1 Signal Input 1 and 2: Review the actual measured value in mA.

AMI Sample Sequencer

Program List and Explanations A-96.250.661 / 120418 59 3 Maintenance 3.1 Signal Outputs 3.1.1 Signal Output 1 to 6: Possibility to simulate a current output manually for test purposes. To simulate a value proceed as follows: 1 Select one of the 6 signal outputs with the [ ] or [ ] key. 2 Press [Enter]. 3 Change the value with the [ ] or [ ] key. Range: 0–20 mA 4 Press [Enter].  The value is simulated at the corresponding signal output. 3.2 Rotary Valve Possibility to switch the 6-way valve manually to any channel for test purposes. To switch the 6-way-valve to a certain position proceed as follows: 1 Press [Enter]. 2 Select the position you want to switch to with the [ ] or [ ] key. 3 Press [Enter].  The 6-way-valve rotates to the defined position. 3.5 Set Time Adjust date and time. 4 Operation Not Applicable.

A-96.250.661 / 120418

AMI Sample Sequencer Program List and Explanations 5 Installation 5.1 Sequence 5.1.1 Mode: Internal, AMI Mode Internal: Set Mode to Internal if the AMI Sample Sequencer is connected to an AMI Sodium A or an AMI Sodium P. In this Mode the AMI Sample Sequencer automatically switches from sample 1 to max. 6. Mode AMI: Set Mode to AMI if the AMI Sample Sequencer is con- nected to an AMI Silica, AMI Silitrace or AMI Phosphate HL. In this Mode the AMI Sample Sequencer works as a slave of the AMI ana- lyzer. No further settings are available in the Mode AMI. NOTICE: Do not set the AMI Sample Sequencer to Mode Internal if it is connected to an AMI Silica, AMI Silitrace or AMI Phosphate HL. 5.1.2 Signal Inputs: The signal inputs are used to receive the measuring signal(s) from the current output of the AMI Sodium A or an AMI Sodium P. The signal(s) are then transferred to a remote device where the measuring value(s) are displayed.  If one signal input is selected, six sample channels are avail- able.  If two signal inputs are selected, three sample channels are available. Range: 1 or 2 5.1.3 Flush Time: Set the flush time duration after channel switching. Range: 10–3600 sec 5.1.4 Valid after: Set the remaining measuring time for channel x after the 6-way valve has switched to the next channel. Range: 0–3600 sec 5.1.5 Cycle Time Set the cycle time of each Channel (1 to max. 6). If the cycle time is set to 0, the channel is switched off. Range: 0–600 min

AMI Sample Sequencer

Program List and Explanations A-96.250.661 / 120418 61 5.2 Sample Flow 5.2.1 Alarm High: If the measured value rises above the alarm high val- ue, the alarm relay is activated and E009 is displayed in the mes- sage list. Range: 0.00–50.00 l/h 5.2.2 Alarm Low: If the measured value falls below the alarm low value, the alarm relay is activated and E010 is displayed in the message list. Range: 0.00–50.00 l/h 5.2.3 Hysteresis: Within the hyst. range, the relay does not switch. This prevents damage of relays contacts when the measured value fluc- tuates around the alarm value. Range: 0.5–5 l/h 5.2.2 Delay: Duration, the activation of the alarm relay is retarded after the messuring value has risen above/fallen below the programmed alarm. Range: 0–28‘800 sec 5.3 Miscellaneous 5.3.1 Language: Set the desired language. Available settings: German/English/French/Spanish 5.3.2 Set defaults: Reset the instrument to factory default values in three different ways:  calibration  in parts  completely 5.3.3 Load Firmware: Firmware updates should be done by instructed service personnel only. 5.3.4 Password: Select a password different from 0000 to prevent unau- thorized access to the menus , and . Each menu may be protected by a different password. If you forgot the passwords, contact the closest SWAN representa- tive.

A-96.250.661 / 120418

AMI Sample Sequencer Default Values 10. Default Values Installation: Sequence: Mode:....................................................................................Internal Signal Inputs:..................................................................................1 Flush Time: ............................................................................ 60 sec Valid After:................................................................................ 0 sec Sequence: Cycle Time: Channel 1–6 ....................................15 min Sample Flow Alarm high:...............................................................................25 l/h Alarm low:..................................................................................5 l/h Hysteresis:..............................................................................0.5 l/h Delay:.....................................................................................10 Sec Miscellaneous Language:.............................................................................English Set default:....................................................................................no Load firmware:..............................................................................no Password:........................................................... for all modes 0000

A-96.250.661 / 120418

63 AMI Sample Sequencer Index 11. Index A AMI Phosphate HL Electrical Connection . 31 Firmware Settings . . . 35 Sample Connection . . 28 AMI Silica Electrical Connection . 31 Firmware Settings . . . 35 Sample Connection . . 26 AMI Silitrace Electrical Connection . 31 Firmware Settings . . . 35 Sample Connection . . 27 AMI Sodium A/P Electrical Connection . 36 Firmware Settings . . . 40 Sample Connection . . 29 C Cable thicknesses. . . . . . 41 Changing parameters. . . . 49 Connecting Example AMI Phosphate HL. . . 28 AMI Silica . . . . . . . . 26 AMI Silitrace . . . . . . 27 AMI Sodium P . . . . . 29 Current . . . . . . . . . . . . 37 Current Outputs . . . . . . . 37 D Deactivate channels. . . . . 39 Default Values . . . . . . . . 62 Dimensions. . . . . . . . . . 21 E Electrical wiring . . . . . . . 23 F Fluidics . . . . . . . . . . . . . 8 I Instrument Setup . . . . . . 23 O On-site requirements . . 20, 23 P Power Supply . . . . . . . . 20 R Relay . . . . . . . . . . . . . . 7 S Sample flow error Mode External . . . . . 44 Mode Internal. . . . . . 44 Sample requirements . . . . 20 Sample Switch Command . 44 Signal inputs AMI Sodium. . . . . . . 37 External Devices . . . . 37 PLC device . . . . . . . 37 Signal Outputs . . . . . . 35, 37 T Terminals. . . . . . . . . . . 42 W Wire . . . . . . . . . . . . . . 41

A-96.250.661 / 120418

AMI Sample Sequencer SWAN is represented worldwide by subsidiary companies and distributors. cooperates with independent representatives all over the world. SWAN Products Analytical Instruments for: High Purity Water Feedwater, Steam and Condensate Potable Water Pool and Sanitary Water Cooling Water Waste Water and Effluents Made in Switzerland

Other Recording Equipment Manuals