Wavetronix Click 112 Quick Start Manual
Text of the manual
Click 112/114 Contact Closure
www.wavetronix.com
801.734.7200
QUICK START GUIDE
2 Understand the device’s configuration features
The following physical features allow you to configure the Click 112/114:
˽
Mode Switch – Allows you to cycle through and select menu and configura-
tion options.
˽
Level 1 LEDs – Light up to indicate menu options while cycling through the
menu. They also have the following functions:
˿
Red – Lights up when the device has power
˿
Blue – Currently has no function
˿
Green – Lights up when the device is transmitting data
˿
Yellow – Lights up when the device is receiving data
˽
Level 2 LEDs – Light up to indicate configuration options. When the de-
vice is not in menu mode, these LEDs are off.
˽
Channel LEDs – The topmost bank of LEDs. These light up to indicate
vehicle detection.
˽
DIP Switches – Located on the lower part of the circuit board (left face of the board, if you’re looking at
the faceplate). These switches allow you to configure the device. This will be covered in greater detail in
Part 4.
www.wavetronix.com
801.734.7200
1 Mount and connect the device
Use the following steps to install the Click 112/114 rack cards:
1
If you’re using hardware configuration, set all DIP switches before
installing Click 112/114 devices (this will be covered in Part 4 of
this document).
2
Insert the cards into the rack.
3
Daisy-chain together all the cards in your installation, using short
RJ-11 jumper cables.
4
Connect the first Click 112/114 card to the SmartSensor via a Click
200 or Click 222 surge protector and a 60” RJ-11 patch cord.
Note. Bus 1 should be used to connect to the sensor, and bus 2 for configuration.
Channel
1
2
3
4
Menu
PWR PU TD RD
Level 1
Mode Switch
Level 2
1
2
3
4
all-guides.c
om
3 Select configuration method
4 Configuration option 1: DIP switches
The DIP switches on the circuit board can be used to change input mapping and the baud rates used for bus
1 and bus 2. These parameters can also be changed using the two other configuration options.
Note. For each parameter, if any of the switches are turned on, that parameter is in Hardware mode. If
Hardware mode is selected, the parameter can only be configured using the switches.
Look at the figure below to see how to set the switches in order to configure the parameter. To turn a switch
on, flip it up.
Channel Input Mapping
This function lets you map two (Click
112) or four (Click 114) of the input data
channels coming from the sensor to the
output channels on the device. The out-
puts are assigned sequentially, so if you se-
lect 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
This function lets you set the baud rate for bus 1 and bus 2. The two buses can be configured separately. Flip
the switches up and down according to the diagram to set the baud rate for each bus.
The Click 112/114 can be configured in three ways: DIP switches, the front panel menu and Click Super-
visor. These three different configuration methods can configure different sets of options; some of these
parameters can be set using multiple configuration methods, and some of them can only be set using one
particular method. This table lists how each
parameter may be accessed and configured.
The final row on the table refers to configu-
ration modes. The DIP switches are used
to choose between Hardware and Software
modes. If any of the switches are on, that
particular parameter is set to Hardware
mode and only the DIP switches can be used
to change its configuration options. If no
switches are on for a particular parameter,
it is in Software mode and the front panel
menu and Click Supervisor must be used to
configure it.
DIP Switch
Front Panel
Menu
Click
Supervisor
Baud Rate
Yes
Yes
Yes
Channel Input Map
Yes
Yes
Yes
Autobaud
No
Yes
No
Reset to Default
No
Yes
Yes
Description
No
No
Yes
Location
No
No
Yes
Device ID
No
No
Yes
To use this
configuration method:
Hardware
Mode
Software
Mode
Software
Mode
SW
SW
1–4
5–8
9–12
13–16
17–20
21–24
25–28
SW
1–2
3–4
5–6
7–8
9–10
11–12
13–14
Click
114
Click
112
SW1
SW2
SW3
SW4
Input Mapping
SW1
SW2
SW3
SW4
Click
112
15–16
17–18
19–20
21–22
23–24
25–26
27–28
SW1
SW2
SW3
SW4
SW5
SW6
Baud Rate
SW
9600
19200
38400
57600
Bus 1
Bus 2
5 Configuration option 2: front panel menu
The front panel menu allows you to configure input mapping and baud rates. It can also reset the device to
factory defaults, and is the only place on the device to access the autobaud function.
Menu and configuration options are displayed on the Level 1 and Level 2 LEDs on the faceplate. Navigate
through the menu using the mode switch:
1
Press and hold the mode switch to enter Menu mode. The Level 1 LEDs will start to light up to indicate
that the device is cycling through all menu options.
2
When the LEDs light up in the way that indicates the menu option you want (see the figure below),
release the mode switch.
3
Quickly press and release the mode switch to select the current menu option. The Level 2 LEDs will
light up to let you configure the options for the selected menu option.
4
Press and hold the mode switch to cycle through available values for the selected menu option. The
Level 2 LEDs display the currently selected value.
5
Press and release the mode switch to accept the displayed value. The device will exit the menu.
Note. If any of the DIP switches are turned on, that parameter will be in Hardware mode and the front
panel menu will only be able to display, not change, that setting.
See the figure to the right for how to use the LEDs to configure the parameter.
Channel Input Mapping
This function lets you map two (Click
112) or four (Click 114) of the input
data channels coming from the sensor to
the output channels on the device. The
outputs are assigned sequentially, so if you
select 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
This function lets you set the baud rate
for bus 1 and bus 2. The two buses can
be configured separately.
Autobaud
This function initiates an autobaud on the RS-485 bus you select. If the autobaud is successful, the LEDs will
display the baud rate found, using the same LED patterns used for the baud rate (see figure above). If it fails,
all four LEDs will flash, and then the device will exit the menu.
Reset to Default
This function will restore all configuration settings to factory defaults (even those not configured using the
front panel menu): baud rate, channel map, description field, location field and device ID.
© 2019 Wavetronix LLC. All rights reserved. Protected in the US by patents viewable at www.wavetronix.com/en/legal. Protected by Canadian Patent Nos. 2461411; 2434756;
2512689; and European Patent Nos. 1435036; 1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Command and all associated
logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective holders. Product specifica-
tions are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.
6 Configuration option 3: Click Supervisor
Install Click Supervisor
Click Supervisor is the third available way to configure the Click 112/114. To
install it:
1
Download the setup file from www.wavetronix.com (under Support).
2
Double-click on the file to run the setup wizard. Follow the steps to install.
Make a connection
1
Make sure there is a connection between the Click 112/114 and the com-
puter that Click Supervisor is on. To do this, there should be a jumper cable
connected from the bus 2 port to a Click device with an RJ-11 jack on the
T-bus, such as a Click 222.
2
Run Click Supervisor and select Communication. This screen lets you pick the type of connection you
want to make, serial or IP. The Click 112/114 will likely be configured using serial communication.
3
Click Settings to make any necessary changes to the settings, such as the port or the baud rate. Click
OK to return to the Communication screen, then click Connect. Keep the Click ID set to 0.
4
In the next screen, Click Supervisor will display all the devices it discovers. When the desired Click
112/114 appears, select it and click Select. Click Supervisor will connect to the device.
Select a driver
Select Setup Click on the main screen. In the next
screen, select the Expert driver and click OK.
Configure the module
The System > General tab has text parameters that
cannot be changed anywhere else. The most important
of these include:
˽
Description/Location – For informational/iden-
tification purposes only. These settings do not
affect the operation of the device.
˽
Device ID – Changes the ID number associated with the device. By default this is the last five digits of the
serial number. The System > Settings tab lets you set certain parameters that can also be changed using the
front panel menu and the DIP switches.
˽
Baud Rate for Bus 1/2 – Changes the baud rates of buses 1 and 2.
˽
Input Mapping – Lets you map two or four of the input data channels coming from the sensor to the
output channels on the device. The outputs are assigned sequentially, so if you select 13–14, then input
13 will be mapped to channel 1, and 14 to channel 2.
Note. If any of the DIP switches are turned on, that parameter will be in Hardware mode and Click Supervi-
sor will only be able to display, not change, that setting.