Wavetronix SmartSensor Matrix Quick Start Manual
Read Online
Read the Wavetronix SmartSensor Matrix Quick Start Manual online using the built-in PDF viewer.
Text of the manual
SPAN WIRE MOUNT INSTALLATION QUICK START GUIDE
1
Choose a mounting of set
Note. T e mounting location for your SmartSensor Matrix sensor(s) should have already been determined as part of the design pro-
cess. If it has not been, please consult the SmartSensor Matrix User Guide for complete design
and installation guidelines.
Use the table at right to choose a suitable of set (distance from the f rst lane of interest), based
on the height of the span wires you’ll be mounting on.
1
Prepare the sensor while still on the ground: remove the large bolts holding the end knuckle (the
one with four holes) to the mount, then use the four small bolts and lock washers to attach the
removed knuckle to the sensor backplate.
2
Secure a span wire hanger assembly, namely the PELCO SP-1050-FL-L-SP0003 or SP-2045-FL-L,
to the top and bottom span wire. If the hanger assembly is too long for the location and part of it
hangs below the span wire, we recommend that you cut of the excess. If the hanger assembly is
too short for the location, switch to a hanger assembly with a longer extension bar.
3
Use the 5/16 bolts that were included with the Pelco hanger assembly to attach the rest of the
span wire mount to the hanger assembly (the knuckle with six holes is the one that attaches to
the span wire assembly). It’s recommended that you put the mount roughly in the middle of the
extension bar, for stability.
4
Attach the knuckle/sensor you prepared earlier to the mount using the large bolts (the cable
connector should be pointed down). Don’t tighten completely yet, as you still need to align the
sensor to the roadway.
Offset
Height
6–15 ft
12–25 ft
15–50 ft
15–25 ft
> 50 ft
25–60 ft
1
Tilt the sensor down so it is aimed at the center of the lanes of
interest.
2
Adjust the side-to-side angle so that the sensor’s 90º f eld of
view covers the approach.
Note. Make sure the front edge of the sensor’s footprint covers
beyond the stop bar. T is allows you to detect vehicles that do not
stop at or behind the stop bar.
3
Align the sensor to the roadway
2
Mount the sensor
T e SmartSensor Matrix can be installed in two ways:
�
On a pole or mast arm, using the SmartSensor mount.
�
On two vertically aligned span wires, using the SmartSensor span wire mount. T e intersection must conform to certain require-
ments in this case; see the knowledge base article called Using the Span Wire Mount for more information.
T is document will cover installations using the span wire mount. For the regular mount, see the SmartSensor Matrix quick start guide.
© 2019 Wavetronix LLC. All rights reserved. Protected in the US by patents viewable at www.wavetronix.com/en/legal. Protected by Canadian Patent Nos. 2461411; 2434756; 2512689; and European Patent Nos. 1435036;
1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Command and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are
trademarks or registered trademarks of their respective holders. Product specifi cations are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability
related to its use.
1
Tear the tab of the tube of silicon dielectric compound that came with the sensor.
2
Squeeze about half of the compound on the connector at the base of the sensor.
3
Insert the cable connector into the sensor connector. Be aware it’s a keyed connector.
4
Twist the cable connector clockwise until you hear it click into place.
5
Mount a junction box to the span wire hanger assembly.
6
Run the cable to the junction box and terminate it in the terminal blocks there.
Leave a small amount of slack in the cable; this reduces strain, allows you to create a drip loop as shown,
and gives you something to work with should you need to move the sensor in the future.
7
Run the homerun cable from the junction box to the pole—it’s recommended you run it along the messen-
ger (lower) span wire—and from there to the traf c cabinet.
8
Connect a 12 AWG grounding wire between the grounding lug on the bottom of the sensor and the span
wire hanger assembly.
1
Place the Click 65x on a cabinet shelf or mount it to the side of the cabinet.
2
Connect the sensor cable to the Click 65x. (If there are multiple sensors at the intersection, the 65x can accept multiple cables.)
3
Make sure each switch by the sensor port is turned on and the LED is illuminated.
4
If your cabinet is SDLC compatible, connect a cable from the SDLC bus on the Click 65x to the controller. If your cabinet isn’t SDLC
compatible, you can connect from the sensor port RJ-11 jacks to contact closure cards and communicate with the controller that way.
6
Confi gure the Click 65x
7
Check alignment in the SmartSensor Manager Matrix software
4
Attach the cable and ground the sensor
5
Install cabinet equipment
T e Click 65x is designed to be communicated with over Ethernet. Before you can connect it to your network, you need to set the static
IP address, subnet mask and default gateway (these numbers should be determined by your IT personnel).
1
Use the arrow keys and screen on the faceplate to navigate the OLED menu.
2
On the main screen, navigate down to Network Setup and press the Accept (green
check mark) button to open the networking screen (shown at right).
3
Set your desired IP address by following these steps: use the lef and right arrow
keys to highlight a number, then use the up and down arrow keys to change that
number. T en move to the next number. Repeat until all the numbers are changed.
4
Press the right key one last time to navigate down to the subnet mask line.
5
Repeat steps 2 and 3 for the subnet mask and default gateway.
6
When you’re done with all three, push the check sign button to conf rm your changes.
Af er you’re done, connect an Ethernet cable to the RJ-45 jack on the faceplate of the device to connect your Click 65x to your network.
1
Click Communication on the main screen and then click the cloud icon at the top of the screen.
2
Under Network Address, enter the IP address and port number of the Click 65x.
3
Click Search. T e f rst time you connect, use a Full search, which will f nd all the Matrix sensors
on the selected RS-485 control bus. A Quick search can be used for any subsequent connections.
4
Once the list of sensors appears, click on the sensor you would like to conf gure; click Connect.
5
On the main menu, click Sensor Setup. T e screen that opens shows vehicle detections as moving
blue dots, called trackers. If the trackers match traf c on the road, the sensor is working properly.
Note. For conf guration instructions, see the SmartSensor Matrix User Guide.