Kramer Electronics Ltd.

DIP-20 – Contents i Contents Introduction 1 Getting Started 1 Overview 3 About HDBaseT™ Technology 4 Defining the DIP-20 Automatic Video Switcher 5 Connecting the DIP-20 Automatic Video Switcher 7 Connecting the Remote Control Switches 9 Wiring the RJ-45 Connectors 9 Principles of Operation 10 Input Selection 10 Signal Loss and Unplugged Cable Timeouts 10 Audio Signal Control 11 VGA Phase Shift 11 Operating the DIP-20 12 Locking the EDID 12 Resetting the DIP-20 12 Analog Audio Output Volume Control 12 Configuring the DIP-20 13 Setting the Configuration DIP-switch 13 Switching Timeouts 14 Using the Step-in Feature 14 Operating the DIP-20 Remotely Using the Web Pages 15 Accessing the DIP-20 Web Pages 15 Switching Input Signals 17 Setting Device Configurations 18 Defining Control Settings 20 Setting Video and Audio Parameters 25 Setting Authentication 26 Managing EDID 27 Upgrading the Firmware 29 About Us 30 Technical Specifications 31 Default IP Parameters 32 Default RS-232 Communication Parameters 32 Default Logon Credentials 32 Supported HDMI Resolutions 33 Supported VGA Resolutions 33 Default EDID 34 HDMI 34 PC-UXGA 36 Protocol 3000 38 Understanding Protocol 3000 39 Kramer Protocol 3000 Syntax 40 Protocol 3000 Commands 41

Kramer Electronics Ltd.

DIP-20 – Introduction 1 Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Getting Started We recommend that you: • Unpack the equipment carefully and save the original box and packaging materials for possible future shipment. • Review the contents of this user manual. Go to www.kramerav.com/downloads/DIP-20 to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate). Achieving the Best Performance • Use only good quality connection cables (we recommend Kramer high-performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables). • Do not secure the cables in tight bundles or roll the slack into tight coils. • Avoid interference from neighboring electrical appliances that may adversely influence signal quality. • Position your Kramer DIP-20 away from moisture, excessive sunlight and dust. This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building. Safety Instructions Caution: There are no operator serviceable parts inside the unit. Warning: Use only the power cord that is supplied with the unit. Warning: Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. Warning: Disconnect the power and unplug the unit from the wall before installing. Recycling Kramer Products The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any

Kramer Electronics Ltd.

DIP-20 – Introduction 2 costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at www.kramerav.com/support/recycling.

Kramer Electronics Ltd.

DIP-20 – Overview 3 Overview Congratulations on purchasing your Kramer DIP-20 Automatic Video Switcher which are part of the Kramer Audio Distribution System and are ideal for: • Display systems requiring simple, automatic input selection. • Multimedia and presentation source selection. • Video distribution in hotel rooms and schools. The DIP-20 is a 4K UHD, HDBaseT transmitter and Step−in commander for computer graphics video, HDMI, unbalanced stereo audio signals embedding and de−embedding. The DIP-20 accepts HDMI and PC graphics video input, an Ethernet signal, serial data, and an unbalanced stereo audio input (that is embedded into the output signal). It transmits the signal via HDBaseT (twisted pair) cable to a compatible receiver (for example, the TP−588D, TP−580RXR or TP-780RXR). The DIP-20 is a PoE (Power over Ethernet) provider and can power compatible PoE acceptors (for example, the TP−588D or TP-780RXR). It supports resolutions of up to 4K@60 UHD (4:2:0). The DIP-20 provides a range of up to 130m (427ft) in normal mode for 1080p@60Hz @36bpp, and 100m (328ft) for 4K @30Hz. When using an extended range receiver and BC-UNIKAT cables, the range is up to 180m (590ft) for 1080p@60Hz @24bpp. To use the DIP-20 in extended range mode you must edit the EDID. For optimum range and performance, use recommended Kramer cables available at www.kramerav.com/product/DIP-20. Note that the transmission range depends on the signal resolution, graphics card and display used. The distance using non-Kramer CAT 6 and CAT 7 cables may not reach these ranges. The DIP-20 Automatic Video Switcher features: • Support for 4K UHD (data rate of up to 10.2Gbps). • Automatic live input detection based on video clock presence. • Automatic input selection based on priority selection or last connected input. • Manual input selection. • Automatic analog audio detection and embedding. • Power over Ethernet that passes electrical power along with data over Ethernet cabling. This allows a single cable to provide both data connection and electrical power to compatible devices. • Control via Kramer Protocol 3000 and embedded Web pages over a LAN. • HDTV support. • HDMI with Deep Color, x.v.Color™ and 3D. • HDCP compliancy—works with sources that support HDCP repeater mode.

Kramer Electronics Ltd.

DIP-20 – Overview 4 • I-EDIDPro™ Kramer Intelligent EDID Processing™ – Intelligent EDID handling & processing algorithm ensures Plug and Play operation for HDMI systems. • A lockable EDID. • Step-in control when connected to a device that provides step-in support. • Remote control via contact-closure switches. • Equalization and re-clocking of the data. • Support for digital audio formats. About HDBaseT™ Technology HDBaseT™ is an advanced, all-in-one connectivity technology (supported by the HDBaseT Alliance). It is particularly suitable in the ProAV – and also the home – environment as a digital networking alternative, where it enables you to replace numerous cables and connectors by a single LAN cable used to transmit, for example, uncompressed, full high-definition video, audio, IR, as well as various control signals. The products described in this user manual are HDBaseT certified.

Kramer Electronics Ltd.

DIP-20 – Defining the DIP-20 Automatic Video Switcher 5 Defining the DIP-20 Automatic Video Switcher Figure 1 defines the front panel of the DIP-20. Figure 1: DIP-20 Front Panel # Feature Function 1 HDMI IN 1 SELECT Button Press to select the HDMI 1 input. When HDMI 1 is selected, the button: • Lights red when analog Audio In audio is selected • Lights green when embedded audio is selected 2 HDMI 1 Connector Connect to the first HDMI source 3 HDMI IN 2 SELECT Button Press to select the HDMI 2 input. When HDMI 2 is selected, the button: • Lights red when analog Audio In audio is selected • Lights green when embedded audio is selected 4 HDMI 2 Connector Connect to the second HDMI source 5 PC IN SELECT Button Press to select the PC graphics input. When PC graphics is selected, the button: • Lights red when analog Audio In audio is selected • Lights green when embedded audio from embedded HDMI is selected, (see Setting the Configuration DIP- switch on page 13) 6 PC Graphics 15-pin HD Connector Connect to the PC graphics source, (for example, a laptop) 7 AUDIO IN 3.5mm Mini Jack Connect to the unbalanced, stereo audio source, (for example, the audio output of the laptop) 8 Step-In Button Press to take control of the input that this device is connected to on a compatible switcher 9 ON LED The LED indicates the following: • Lights green—power is provided by a power adapter • Lights red—power is provided via PoE to another device

Kramer Electronics Ltd.

DIP-20 – Defining the DIP-20 Automatic Video Switcher 6 Figure 2 defines the rear panel of the DIP-20. Figure 2: DIP-20 Rear Panel # Feature Function 1 AUDIO OUT 3.5mm Mini Jack Connect to the unbalanced, stereo audio acceptor, (for example, active speakers) 2 ETHERNET RJ-45 Connector Connect to the LAN, (Ethernet traffic or PC controller) 3 RS- 232 CONTROL 3-pin Terminal Block Connect to a serial controller or PC 4 DATA 3-pin Terminal Block Connect to a serial data source or acceptor, (RS-232 data over HDBT) 5 PC/HDMI Remote Toggle Switch Terminal Block Connect to a remote switch to toggle between the PC graphics and HDMI inputs 6 Remote Contact-closure 4-pin Terminal Block Connect to remote momentary switches to control input selection, step-in, and volume up and down 7 FACTORY RESET Button Short press to reboot, long press to reset the device to factory default parameters 8 SETUP 4-way DIP-switch Switches for setting the device behavior, (see Setting the Configuration DIP-switch on page 13) 9 PROG Mini USB Connector Connect to a PC to perform a firmware upgrade 10 HDBT OUT RJ-45 TP Connector Connect to a compatible HDBT TP switcher or receiver (for example, the TP-588D / TP-580Rxr / TP-780Rxr) 11 LINK LED Lights green when there is a valid HDBT link 12 48V DC Connector Connect to the supplied power adapter 13 STEP IN Remote Toggle Switch Terminal Block Connect to a remote switch to activate the step in function

Kramer Electronics Ltd.

DIP-20 – Connecting the DIP-20 Automatic Video Switcher 7 Connecting the DIP-20 Automatic Video Switcher Always switch off the power to each device before connecting it to your DIP-20. After connecting your DIP-20, connect the power to each of them and then switch on the power to each device. Figure 3: Connecting the DIP-20 You do not have to connect all the inputs and outputs, connect only those that are required.

Kramer Electronics Ltd.

DIP-20 – Connecting the DIP-20 Automatic Video Switcher 8 To connect the DIP-20 as illustrated in Figure 3: 1. Connect an HDMI source, (for example, a Blu-ray disk player) to the HDMI IN 1 input. 2. Connect a PC graphics source, (for example, a laptop) to the PC In input. 3. Connect an unbalanced stereo audio source, (for example, the audio output from the laptop) to the AUDIO IN 3.5mm mini jack. 4. Connect the HDBT OUT RJ-45 connector on the rear panel of the DIP-20 to an HDBT- compatible receiver (for example, the TP-588D, TP-580Rxr, or TP-780Rxr). 5. Connect the HDMI output of the HDBT acceptor, (for example, the TP-588D, TP- 580Rxr, or TP-780Rxr) to the HDMI acceptor, (for example, a projector). 6. Connect the AUDIO OUT 3-pin terminal block on the rear panel of the DIP-20 to the unbalanced, stereo audio acceptor, (for example, active speakers). 7. Connect the STEP IN 2-way terminal block to a momentary, contact-closure switch, (see Section Connecting the Remote Control Switches on page 9). 8. Connect the PC/HDMI 2-way terminal block to a momentary, contact-closure switch, (see Section Connecting the Remote Control Switches on page 9). 9. Connect the RS-232 DATA 3-pin terminal block to the device to be controlled, (for example, the projector connected in step 5). 10. Connect the power adapter to the DIP-20 and to the mains power, (not shown in Figure 3).

Kramer Electronics Ltd.

DIP-20 – Connecting the DIP-20 Automatic Video Switcher 9 Connecting the Remote Control Switches You can connect remote, momentary-contact contact-closure switches to the terminal block on the rear panel of the DIP-20 to control the device. Figure 4 illustrates the connections from the terminal block to the contact-closure switches. Figure 4: Remote Switches Terminal Block # Feature Function 1 PC/HDMI—input selection/VGA phase shift adjustment Short press—Input toggle Long press—Adjusts the VGA phase shift, (see VGA Phase Shift on page 11) 2 STEP IN Activates the step-in function if relevant 3 VOL UP—analog audio output volume increase control, (see Section Analog Audio Output Volume Control on page 12) Short press—Increases the volume one step Long press—Increases the volume from 0% to 100% in 10 seconds 4 VOL DN—analog audio output volume decrease control, (see Section Analog Audio Output Volume Control on page 12) Short press—Decreases the volume one step Long press—Decreases the volume from 100% to 0% in 10 seconds G GND Connect to the common side of the switches Wiring the RJ-45 Connectors This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors. EIA /TIA 568B Figure 5: TP PINOUT PIN Wire Color 1 Orange / White 2 Orange 3 Green / White 4 Blue 5 Blue / White 6 Green 7 Brown / White 8 Brown

Kramer Electronics Ltd.

DIP-20 – Principles of Operation 10 Principles of Operation The DIP-20 selects video and audio inputs based on the rules described below. Input Selection The video mode selection is set by the DIP-switches (see Setting the Configuration DIP- switch on page 13) to either of the following modes: • Manual • Auto—Last connected or priority mode In manual mode switching occurs whether or not there is a live signal present on the input. You select manually select an input using any of the following methods: • Front panel buttons • Remote input selection switches • RS-232 control • The Web pages In auto mode, the switching selection is performed based on either last connected or priority input. In last connected mode, if the signal on the current input is lost, the DIP-20 automatically selects the last connected input, (the delay depending on a configurable timeout). In priority mode, when the input sync signal is lost for any reason, the input with a live signal and next in priority is selected automatically, (the delay depending on the configurable signal- lost timeout). This priority is configurable; the default setting is HDMI 1 → HDMI 2 → PC. Note: In both last connected and priority modes, manually selecting an input (using the remote input selection switches or any of the above methods) overrides automatic selection. Signal Loss and Unplugged Cable Timeouts In both last connected and priority modes, when the input signal sync is lost (but the cable is not removed) there is a default delay (ten seconds for video, not applicable to the PC input, and five seconds for analog audio) before another input is automatically selected. When an input cable is removed, there is a delay before automatic switching takes place. Both timeouts are configurable, (see Setting the Configuration DIP-switch on page 13). Note: When “Audio Only” mode is enabled, analog audio is not output when there is no display connected. If a display is connected analog audio is output even in the absence of a video signal.

Kramer Electronics Ltd.

DIP-20 – Principles of Operation 11 Audio Signal Control The Option DIP-switches 3 and 4 (see Section Setting the Configuration DIP-switch on page 13) control the manner in which audio is handled. The following table describes which audio signal is embedded in the output. Selected Video Input HDMI Embedded Audio Detected Analog Audio Detected DIP- switch 3 DIP-switch 4 Audio on HDMI Output VGA N/A Yes N/A N/A Analog audio VGA N/A No N/A N/A No audio HDMI N/A N/A Manual Embedded Embedded audio HDMI N/A N/A Manual Analog Analog audio HDMI Yes No Auto N/A Embedded audio HDMI Yes Yes Auto Embedded Embedded audio HDMI Yes Yes Auto Analog Analog audio HDMI No Yes Auto N/A Analog audio HDMI No No Auto N/A No audio When there is an audio signal but no video signal the output is a black video pattern in conjunction with the external analog Audio In signal. Note: The default timeout for audio switching when the input signal is lost is five seconds. This can be changed using either P3000 commands or the Web pages. VGA Phase Shift To minimize phase on the input VGA signal, the VGA sampling phase can be shifted using the following methods: • A long press on the PC IN select button on the front panel. Each long press steps the phase shift up one step, starting from 0 and going to 31. When set to 31, another long press steps the shift to 0 • A remote, contact-closure switch connected to pins PC/HDMI and GND of the Remote terminal block. Each long press steps the phase shift up one step, starting from 0 and going to 31. When set to 31, another long press steps the shift to 0 • Using the Web pages, (see Accessing the DIP-20 Web Pages on page 15) • Protocol 3000 commands over RS-232 (see Protocol 3000 on page 38)

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 12 Operating the DIP-20 The DIP-20 can be operated using any of the following methods: • Front panel buttons • Protocol 3000 command, (see Protocol 3000 on page 38) • Remote contact-closure switch, (see Connecting the Remote Control Switches on page 9) • Web pages, (see Operating the DIP-20 Remotely Using the Web Pages on page 15) Locking the EDID To prevent the stored EDID (either default or read from a device) from being overwritten, either send a Protocol 3000 command or use the Web pages. Resetting the DIP-20 To perform a soft reset of the DIP-20: • Briefly press the Reset button. The device resets To reset the DIP-20 to factory default parameters: • Press and hold the Reset button for five seconds. The device is reset to factory default parameters Analog Audio Output Volume Control The analog audio output volume can be controlled using the Web pages, (see Accessing the DIP-20 Web Pages on page 15) or via the remote, contact-closure switches connected to pins 3 and 4 of the Remote terminal block, (see Connecting the Remote Control Switches on page 9). The volume is adjustable from -83dB to +24dB.

Kramer Electronics Ltd.

DIP-20 – Configuring the DIP-20 13 Configuring the DIP-20 Setting the Configuration DIP-switch The 4-way DIP-switch provides the ability to configure a number of device functions. A switch that is down is on; a switch that is up is off. By default, all the switches are up (off). Figure 6: The Configuration DIP-switch Note: After changing a DIP-switch you must power cycle the device to implement the change. Video Switching Selection DIP- switch 1 DIP- switch 2 Video Input Selection Off (up) Off (up) Automatic—Last connected. Where more than one source is connected the last one connected has priority Off (up) On (down) Automatic—Priority selection. HDMI 1  HDMI 2  PC IN (default, high to low priority) On (down) Off (up) Manual On (down) On (down) Manual Audio Switching Selection DIP- switch 3 DIP- switch 4 Audio Input Selection Off (up) Off (up) Automatic—Priority selection. Embedded HDMI  analog Audio In (high to low priority) Off (up) On (down) Automatic—Priority selection. Analog Audio In  embedded HDMI (high to low priority) On (down) Off (up) Embedded HDMI On (down) On (down) Analog Audio In

Kramer Electronics Ltd.

DIP-20 – Configuring the DIP-20 14 Switching Timeouts When the DIP-20 is configured for auto switching, the timeouts (before a new input is automatically selected) can be changed as shown in the tables below. (For the delay settings on the Web page, see (see Defining Control Settings on page 20). The following switching timeouts are only for HDMI and not VGA. Timeout Minimum Value Default Value Delay switching upon signal loss while cable is plugged in (signal off, 5V power on) 5 seconds 10 seconds for video input 5 seconds for audio input Delay switching upon cable unplug (signal off, power off) 0 seconds 0 seconds Delay 5V power off upon signal loss (delay must be greater than “Delay switching upon signal loss”) Should at least equal the larger of the above two values (signal loss timeout and cable unplug timeout) 900 seconds For example, if: Delay switching upon signal loss = 15 seconds Delay switching upon cable unplug = 30 seconds Then: Delay 5V power off upon signal loss must be >= 30 seconds Using the Step-in Feature To be able to use the Step-in feature, you need to assign the RS-232 signal that is transmitted over the HDBT link to control (see Defining Control Settings on page 20). The Step-in button on the front panel will now operate in conjunction with a compatible receiver, for example, the VS-622DT).

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 15 Operating the DIP-20 Remotely Using the Web Pages The DIP-20 can be operated remotely using the embedded Web pages. The Web pages are accessed using a Web browser and an Ethernet connection. Before attempting to connect: • Ensure that your browser is supported (see Default IP Parameters on page 32) • Ensure that JavaScript is enabled Accessing the DIP-20 Web Pages In the event that a Web page does not update correctly, clear your Web browser’s cache by pressing CTRL+F5. To access the DIP-20 Web pages: 1. Open your Internet browser. 2. Type the IP number of the device (see Default IP Parameters on page 32) in the Address bar of your browser. If authentication is enabled, the following window appears (Figure 7) and you must enter the valid username and password to access the Web pages. For default authentication details, see Default Logon Credentials on page 32. Figure 7: Entering Logon Credentials

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 16 Following a successful logon, the screen shown in Figure 8 is displayed. Figure 8: DIP-20 Web pages • To open / hide the left hand side page navigation panel, click / . • To lock the page, click . • To toggle in and out of full screen mode, click . The following sections describe how to use the Web pages and their functions: • Switching Input Signals (see Switching Input Signals on page 17) • Setting Device Configurations (see Setting Device on page 18) • Defining Control Settings (see Defining Control Settings on page 20) • Setting Video and Audio Parameters (see Setting Video and Audio Parameters on page 25) • Setting Authentication (see Setting Authentication on page 26) • Managing EDID (see Managing EDID on page 27) • Upgrading Firmware (see Upgrading the Firmware on page 29) • About (see About Us on page 30)

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 17 Switching Input Signals The Switching page lets you select a video input manually and adjust the audio volume. Figure 9: Switching Page Item Description HDMI 1 Button Click to select the HDMI 1 input. The button color indicates whether or not there is a live signal on the input HDMI 2 Button Click to select the HDMI 2 input VGA Button Click to select the VGA input VGA Phase change Slider Click and slide to the left or right to adjust the VGA phase change (+1 to +31) Audio Indicator Indicates the source of the audio that is transmitted on the output Volume Slider Click and slide up and down to increase or decrease the audio output volume (- 83dB to +24dB) Mute/Unmute Button Click to mute or unmute the output audio Note: To be able to use the Step-in feature, you need to assign the RS-232 signal that is transmitted over the HDBT link to control (see Defining Control Settings on page 20). The Step-in button on the front panel now operates in conjunction with a compatible receiver, for example, the VS-622DT).

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 18 Setting Device Configurations The Device Settings page enables you to identify your device and: • View some of the device characteristics, (for example, model and firmware version) • Edit Ethernet settings, (for example, DHCP and IP address) • Save and load configurations • Reset the device to factory default settings Note: After making any change to the parameters on the Device Settings page, you must power cycle the device to activate the changes. Figure 10: Device Settings Page

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 19 Item Description Unit name Enter a descriptive, easy to identify name for the DIP-20 Model Displays the model of the device Firmware version Displays the firmware version of the device Serial number Displays the serial number of the device Ethernet Settings DHCP ON/OFF buttons Click ON to turn DHCP on; click OFF to turn DHCP off and use static IP addressing IP address The IP address of the device. To set a new IP address, enter the new valid IP address and click Set Mask address The network mask of the device. To set a new mask address, enter the new valid mask address and click Set Gateway address The network gateway for the device. To set a new gateway address, enter the new valid gateway address and click Set Mac address The MAC address of the device UDP port The UDP port number of the device. To set a new UDP port number, enter the new valid port number or use the spin controls and click Set TCP port The TCP port number of the device. To set a new TCP port number, enter the new valid port number or use the spin controls and click Set All settings Load & Save buttons Click Load to retrieve a previously saved configuration, click Save to save the present configuration (see Loading and Saving Configurations on page 19). Factory reset button Click to reset the device to factory default parameters. After the success message is displayed, power cycle the device (see Resetting the Device on page 20) Loading and Saving Configurations The DIP-20 enables loading and saving device setting configurations. This is especially useful when setting up multiple DIP-20 devices. To load a configuration: 1. Click Load. The File Upload browser window appears. 2. Browse to the required file and click Open. The configuration is retrieved and the success message is displayed. To save the current configuration: 1. Click Save. The Save Configuration success message is displayed. 2. Click Download to either open the file or save it to the required location. Or, Click OK to complete the procedure.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 20 Resetting the Device To reset the DIP-20 to factory default parameters: 1. Click Factory reset. A confirmation message is displayed. Clicking Cancel exits the reset procedure without making any changes. 2. Click OK. A progress message is displayed. Upon completion, a success message is displayed. 3. Click OK. Defining Control Settings The Control Settings page enables specifying how the HDBT Out port and the RS-232 data port (not the control port) can be used for sending data strings, Protocol 3000 control commands, or external device control commands. You can specify this by selecting any of the following in the HDBaseT Serial Settings area: • HDBaseT Tunneling from Data Port – Enables routing all RS-232 data from the RS- 232 data port to the HDBT port. • DIP-20 Control through HDBaseT – Enables controlling the DIP-20 using Protocol 3000 commands received over HDBaseT (for step-in functionality). • Remote Device Control over HDBaseT – Enables sending RS-232 commands over HDBaseT to turn on/off peripheral devices. When using this option, specify the predefined triggers (5V on – connect, 5V off – disconnect) with delays and default RS- 232 parameters.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 21 Figure 11: Control Settings Page The Remote Device Control area in the Control Settings page is divided into four sections: Ports, Commands, Triggers, and Editor. Clicking Ports, Commands, or Triggers enables you to configure that section in the Editor section. The following table describes the elements of the Control Settings page: Item Description Ports Use this section to specify port properties Commands Use this section to select a power on or power off command Triggers Use this section to select trigger conditions that initiate the power on/off actions Editor Use this section to edit information of the selected element Cancel Exit control settings without saving changes Save all Save the current configuration

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 22 To remotely control a device over HDBaseT: 1. In the HDBaseT Serial Settings area, select Remote Device Control over HDBaseT. The Remote Device Control area is enabled. 2. In the Ports section, click the RS-232 port. The port information is displayed in the Editor: Figure 12: Editing an RS-232 Port 3. Edit the port information as necessary and click Save All.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 23 4. In the Commands section, select a command. The command information is displayed in the Editor: Figure 13: Editing a Command 5. Optionally, edit the delay time before the command is triggered, click Test to test the command using the specified port, and click Save All.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 24 6. In the Triggers section, select a trigger. The trigger information is displayed in the Editor: Figure 14: Editing a Trigger 7. Click Enabled. 8. Click Save All.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 25 Setting Video and Audio Parameters Use the Video and Audio Settings page to modify the video, audio and timeout parameters. Figure 15: Video and Audio Settings Page The following table describes the elements of the Video and Audio Settings page: Item Description Video selection mode Indicator Indicates the current video selection mode; manual, auto, or auto last connected Video auto switching priority Buttons Click and drag the buttons to the required priority level to use when in auto mode Audio selection mode Indicator Indicates the current audio selection; manual, auto, or auto last connected Current selection Audio Indicator Indicates the current audio selection; Embedded or analog Audio only mode Buttons Select to enable/disable audio only mode. Disabled—Audio only mode is disabled Enabled—Audio only mode is enabled When enabled, if there is no video signal in the input, the device outputs a black pattern and the analog audio input will continue to input any audio signal. HDCP Support (on HDMI input) Buttons Select HDCP support for HDMI 1 and HDMI 2 Disabled—HDCP encrypted content is not passed Enabled—HDCP support is dictated by the display Delay switching upon signal loss for (leave 5V on) Box Sets the delay for video and audio before switching (in auto mode) because of a signal loss on the currently selected input, while the cable is plugged in. Value in seconds (see Signal Loss and Unplugged Cable Timeouts on page 10) Delay switching input upon cable unplug for Box Sets the delay for video and audio before switching (in auto mode) because the currently selected input cable is unplugged. Value in seconds (see Signal Loss and Unplugged Cable Timeouts on page 10) Delay power off 5V upon signal loss for Box Sets the delay for turning off the 5V output because of a signal loss on the currently selected input. Value in seconds (see Signal Loss and Unplugged Cable Timeouts on page 10)

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 26 Setting Authentication The Authentication page enables activating device security and defining logon authentication details. When device security is enabled, Web page access requires authentication. The default password is Admin. Figure 16: Authentication Page The following table describes the elements of the Authentication page: Item Description Activate Security Button Click to enable/disable security settings. When enabled, the valid username and password must be provided to allow Web page access Change Password Current password box Enter the current password New password box Enter the new password, (up to 15 printable ASCII characters) Retype New password box Retype the new password Change button Click Change to save the new authentication details

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 27 Managing EDID The EDID page lets you copy EDID data to either or all of the inputs from the following sources: • Output • Input • Default EDID • EDID data file From this page you can also lock the EDID on each input independently by pressing the lock icon. Figure 17: EDID Management Page When the status of an EDID changes on the device (caused by outputs being exchanged), the display is not updated automatically. In the browser, click Refresh to update the display.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 28 Item Description Read from Section Input 1 button Click to read the EDID from input 1 (HDMI 1) Input 2 button Click to read the EDID from input 2 (HDMI 2) Input 3 button Click to read the EDID from input 3 (VGA) Output button Click to read the EDID from output DEFAULT EDID button Click to read the default EDID File … Click to open the file browser to select an EDID file on your computer Short Summary Information Section Displays the current selection of EDID source, destination, video resolution, and audio availability Copy to Section Un/Select All selection box Check to select or deselect all inputs Lock button Locks the EDID on the currently selected input Input 1 button Click to select input 1 as the destination (HDMI 1) Input 2 button Click to select input 2 as the destination (HDMI 2) Input 3 button Click to select input 3 as the destination (VGA) COPY Button Click to copy the EDID from the selected source to the selected destination Bytemap Button Click to view the hex code of the EDID To copy EDID data from a source to one or all inputs: 1. In the Read from section, click a source button from which to read the EDID (default, output, input, or EDID file). The button changes color and the EDID summary information reflects the selection and EDID data. 2. In the Copy to section, click an input or select all inputs by checking the Un/Select All check-box. All selected input buttons change color and the EDID summary information reflects the selection and EDID data. 3. Click Copy. The “EDID was copied” success message is displayed and the EDID data is copied to the selected input(s). 4. Click OK. Note: An input must be connected to the device to read the EDID from a connected output. If a video signal is not detected on the input, the output is disabled and the EDID cannot be read.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 29 Upgrading the Firmware As problems are fixed or features are added, new firmware versions are released for downloading on the Kramer website. To upgrade the firmware: 1. Open the Firmware Upgrade page. Figure 18: Firmware Upgrade Page 2. Click Update. The Windows Browser opens. 3. Browse to the required file and click Open. The firmware file name is displayed in the Firmware Upgrade page. 4. Click Start Upgrade. The firmware file is loaded and a progress bar is displayed. Do not interrupt the process or the DIP-20 may be damaged. 5. When the process is complete reboot the device. The firmware is upgraded. You can upgrade firmware for multiple DIP-20 devices installed in the organization via Kramer Network.

Kramer Electronics Ltd.

DIP-20 – Operating the DIP-20 Remotely Using the Web Pages 30 About Us The DIP-20 About Us page displays the Web version and Kramer contact information. Figure 19: About Us Page

Kramer Electronics Ltd.

DIP-20 – Technical Specifications 31 Technical Specifications INPUTS: Video: 2 HDMI on HDMI connectors 1 VGA on a 15-pin HD (F) connector Audio: 1 Unbalanced stereo audio 1V RMS (nominal) on a 3.5mm mini jack OUTPUTS: Video: 1 HDBaseT on an RJ-45 connector Audio: 1 Unbalanced stereo audio 1V RMS (nominal) on a 3.5mm mini jack PORTS: 1 Ethernet on an RJ-45 connector 1 RS-232 3-pin terminal block control port 1 RS-232 3-pin terminal block data port 1 USB on mini USB connector CONTROLS: Remote switches for input switching, step-in, volume control, and device reset switch STANDARDS: HDMI with Deep Color, x.v.Color™ and 3D HDCP—works with sources that support HDCP repeater mode HDBT certified MAXIMUM ANALOG AUDIO LEVELS: 3.1V p-p THD: 0.013% SNR: 75dB SUPPORTED WEB BROWSERS: Windows 7 and higher: Internet Explorer (32/64 bit) version 11 Firefox version 30 Chrome version 35 MAC: Chrome version 35 Firefox version 27 Safari version 7 Android OS: Chrome version 35 iOS: Chrome version 35 Safari version 7 MAXIMUM TRANSMISSION DISTANCE: 180m (590ft) up to 1080p @60Hz @24bpp in extended mode 130m (430ft) up to 1080p @60Hz @36bpp in normal mode POWER CONSUMPTION: 48V DC, 630mA 200mA with CAT5e 24AWG OPERATING TEMPERATURE: 0° to +40°C (32° to 104°F) STORAGE TEMPERATURE: –40° to +70°C (–40° to 158°F) HUMIDITY: 10% to 90%, RHL non-condensing COOLING: Convection ENCLOSURE TYPE: Aluminum DIMENSIONS: 18.75cm x 11.5cm x 2.54cm (7.38” x 4.53” x 1.0”) W, D, H WEIGHT: 0.46kg (1.01lbs) approx. SHIPPING WEIGHT: 1.16kg (2.56lbs) approx. ENVIRONMENTAL REGULATORY COMPLIANCE: Complies with appropriate requirements of RoHs and WEEE INCLUDED ACCESSORIES: Power adapter 48V DC 1.36A WARRANTY: 7 years parts and labor

Kramer Electronics Ltd.

DIP-20 – Technical Specifications 32 Default IP Parameters Parameter Values Default Device Name Any alphanumeric string up to 14 chars (can include hyphen, but not at the beginning or end) KRAMER_ DHCP ON/OFF OFF IP Address Any valid IP address 192.168.1.39 Mask Any valid network mask 255.255.0.0 Gateway Any valid gateway address 192.168.0.1 TCP Port 0 to 65535 5000 UDP Port 0 to 65535 50000 Default RS-232 Communication Parameters Parameter Values Baud Rate 11520 Data Bits 1 Stop Bits 1 Parity None Command Format ASCII Default Logon Credentials Parameter Values Name Admin Password Admin

Kramer Electronics Ltd.

DIP-20 – Technical Specifications 33 Supported HDMI Resolutions Resolution Refresh Rate (Hz) 640x480p 85Hz; 75Hz; 72Hz; 60Hz; 59.95Hz 720x480p 60Hz 720x480i 30Hz 720x576p 50Hz 800x600p 85Hz; 75Hz; 72Hz; 60Hz 848x480p 60Hz 852x480p 60Hz 1024x768p 85Hz; 75Hz; 70Hz; 60Hz 1152x864p 75Hz 1280x768p 60Hz 1280x800p 60Hz 1280x960 60Hz 1280x1024p 75Hz; 60Hz 1360x768p 60Hz 1366x768 60Hz; 50Hz 1400x1050p 60Hz 1440x900p 60Hz 1600x900p 60Hz 1600x1200p 60Hz 1680x1050p 60Hz 1920x1080p 50Hz; 60Hz; 30Hz; 24Hz; 1920x1080i 50Hz; 60Hz; 3840x2160 30Hz 4096x2160 30Hz Supported VGA Resolutions Resolution Refresh Rate 640x480p 60Hz 720x480p 60Hz 800x600p 60Hz 848x480p 60Hz 1024x768p 60Hz 1152x864 75Hz 1280x720p 60Hz; 50Hz 1280x768 60Hz 1280x800 60Hz 1280x960p 60Hz 1280x1024p 60Hz 1360x768 60Hz; 1366x768 60Hz; 50Hz 1400x1050 60Hz 1440x900 60Hz 1920x1080p 60Hz 1920x1200 60Hz

Kramer Electronics Ltd.

DIP-20 – Default EDID 34 Default EDID Each input on the DIP-20 is loaded with a factory default EDID. HDMI Monitor Model name...............DIP-20 Manufacturer............. KMR Plug and Play ID......... KMR1200 Serial number............ n/a Manufacture date......... 2015, ISO week 255 Filter driver............ None ------------------------- EDID revision............ 1.3 Input signal type........ Digital Color bit depth.......... Undefined Display type............. RGB color Screen size.............. 520 x 320 mm (24.0 in) Power management......... Standby, Suspend, Active off/sleep Extension blocs.......... 1 (CEA-EXT) ------------------------- DDC/CI................... n/a Color characteristics Default color space...... Non-sRGB Display gamma............ 2.20 Red chromaticity......... Rx 0.674 - Ry 0.319 Green chromaticity....... Gx 0.188 - Gy 0.706 Blue chromaticity........ Bx 0.148 - By 0.064 White point (default).... Wx 0.313 - Wy 0.329 Additional descriptors... None Timing characteristics Horizontal scan range.... 30-83kHz Vertical scan range...... 56-76Hz Video bandwidth.......... 170MHz CVT standard............. Not supported GTF standard............. Not supported Additional descriptors... None Preferred timing......... Yes Native/preferred timing.. 1280x720p at 60Hz (16:10) Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync Standard timings supported 720 x 400p at 70Hz - IBM VGA 720 x 400p at 88Hz - IBM XGA2 640 x 480p at 60Hz - IBM VGA 640 x 480p at 67Hz - Apple Mac II 640 x 480p at 72Hz - VESA 640 x 480p at 75Hz - VESA 800 x 600p at 56Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 72Hz - VESA 800 x 600p at 75Hz - VESA 832 x 624p at 75Hz - Apple Mac II 1024 x 768i at 87Hz - IBM 1024 x 768p at 60Hz - VESA 1024 x 768p at 70Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1152 x 870p at 75Hz - Apple Mac II 1280 x 1024p at 75Hz - VESA STD 1280 x 1024p at 85Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1024 x 768p at 85Hz - VESA STD 800 x 600p at 85Hz - VESA STD 640 x 480p at 85Hz - VESA STD 1152 x 864p at 70Hz - VESA STD 1280 x 960p at 60Hz - VESA STD EIA/CEA-861 Information

Kramer Electronics Ltd.

DIP-20 – Default EDID 35 Revision number.......... 3 IT underscan............. Supported Basic audio.............. Supported YCbCr 4:4:4.............. Supported YCbCr 4:2:2.............. Supported Native formats........... 1 Detailed timing #1....... 1920x1080p at 60Hz (16:10) Modeline............... "1920x1080" 148.500 1920 2008 2052 2200 1080 1084 1089 1125 +hsync +vsync Detailed timing #2....... 1920x1080i at 60Hz (16:10) Modeline............... "1920x1080" 74.250 1920 2008 2052 2200 1080 1084 1094 1124 interlace +hsync +vsync Detailed timing #3....... 1280x720p at 60Hz (16:10) Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync Detailed timing #4....... 720x480p at 60Hz (16:10) Modeline............... "720x480" 27.000 720 736 798 858 480 489 495 525 -hsync -vsync CE audio data (formats supported) LPCM 2-channel, 16/20/24 bit depths at 32/44/48 kHz CE video identifiers (VICs) - timing/formats supported 1920 x 1080p at 60Hz - HDTV (16:9, 1:1) 1920 x 1080i at 60Hz - HDTV (16:9, 1:1) 1280 x 720p at 60Hz - HDTV (16:9, 1:1) [Native] 720 x 480p at 60Hz - EDTV (16:9, 32:27) 720 x 480p at 60Hz - EDTV (4:3, 8:9) 720 x 480i at 60Hz - Doublescan (16:9, 32:27) 720 x 576i at 50Hz - Doublescan (16:9, 64:45) 640 x 480p at 60Hz - Default (4:3, 1:1) NB: NTSC refresh rate = (Hz*1000)/1001 CE vendor specific data (VSDB) IEEE registration number. 0x000C03 CEC physical address..... 1.0.0.0 Maximum TMDS clock....... 165MHz CE speaker allocation data Channel configuration.... 2.0 Front left/right......... Yes Front LFE................ No Front center............. No Rear left/right.......... No Rear center.............. No Front left/right center.. No Rear left/right center... No Rear LFE................. No Report information Date generated........... 09/08/2015 Software revision........ 2.60.0.972 Data source.............. File Operating system......... 6.1.7601.2.Service Pack 1 Raw data 00,FF,FF,FF,FF,FF,FF,00,2D,B2,00,12,00,00,00,00,FF,19,01,03,80,34,20,78,EA,B3,25,AC,51,30,B4,26, 10,50,54,FF,FF,80,81,8F,81,99,A9,40,61,59,45,59,31,59,71,4A,81,40,01,1D,00,72,51,D0,1E,20,6E,28, 55,00,07,44,21,00,00,1E,00,00,00,FD,00,38,4C,1E,53,11,00,0A,20,20,20,20,20,20,00,00,00,FC,00,44, 49,50,2D,32,30,0A,20,20,20,20,20,20,02,3A,80,18,71,38,2D,40,58,2C,45,00,07,44,21,00,00,1E,01,A0, 02,03,1B,F1,23,09,07,07,48,10,05,84,03,02,07,16,01,65,03,0C,00,10,00,83,01,00,00,02,3A,80,18,71, 38,2D,40,58,2C,45,00,07,44,21,00,00,1E,01,1D,80,18,71,1C,16,20,58,2C,25,00,07,44,21,00,00,9E,01, 1D,00,72,51,D0,1E,20,6E,28,55,00,07,44,21,00,00,1E,8C,0A,D0,8A,20,E0,2D,10,10,3E,96,00,07,44,21, 00,00,18,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,47

Kramer Electronics Ltd.

DIP-20 – Default EDID 36 PC-UXGA Monitor Model name............... DIP-20 Manufacturer............. KMR Plug and Play ID......... KMR1200 Serial number............ n/a Manufacture date......... 2015, ISO week 255 Filter driver............ None ------------------------- EDID revision............ 1.3 Input signal type........ Analog 0.700,0.000 (0.7V p-p) Sync input support....... Separate, Composite, Sync-on-green Display type............. RGB color Screen size.............. 520 x 320 mm (24.0 in) Power management......... Standby, Suspend, Active off/sleep Extension blocs.......... None ------------------------- DDC/CI................... n/a Color characteristics Default color space...... sRGB Display gamma............ 2.20 Red chromaticity......... Rx 0.674 - Ry 0.319 Green chromaticity....... Gx 0.188 - Gy 0.706 Blue chromaticity........ Bx 0.148 - By 0.064 White point (default).... Wx 0.313 - Wy 0.329 Additional descriptors... None Timing characteristics Horizontal scan range.... 30-83kHz Vertical scan range...... 56-76Hz Video bandwidth.......... 170MHz CVT standard............. Not supported GTF standard............. Not supported Additional descriptors... None Preferred timing......... Yes Native/preferred timing.. 1280x720p at 60Hz (16:10) Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync Detailed timing #1....... 1920x1080p at 60Hz (16:10) Modeline............... "1920x1080" 148.500 1920 2008 2052 2200 1080 1084 1089 1125 +hsync +vsync Standard timings supported 720 x 400p at 70Hz - IBM VGA 720 x 400p at 88Hz - IBM XGA2 640 x 480p at 60Hz - IBM VGA 640 x 480p at 67Hz - Apple Mac II 640 x 480p at 72Hz - VESA 640 x 480p at 75Hz - VESA 800 x 600p at 56Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 72Hz - VESA 800 x 600p at 75Hz - VESA 832 x 624p at 75Hz - Apple Mac II 1024 x 768i at 87Hz - IBM 1024 x 768p at 60Hz - VESA 1024 x 768p at 70Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1152 x 870p at 75Hz - Apple Mac II 1280 x 1024p at 75Hz - VESA STD 1280 x 1024p at 85Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1024 x 768p at 85Hz - VESA STD 800 x 600p at 85Hz - VESA STD 640 x 480p at 85Hz - VESA STD 1152 x 864p at 70Hz - VESA STD 1280 x 960p at 60Hz - VESA STD Report information Date generated........... 04/04/2019 Software revision........ 2.90.0.1020 Data source.............. File - NB: improperly installed

Kramer Electronics Ltd.

DIP-20 – Default EDID 37 Operating system......... 10.0.16299.2 Raw data 00,FF,FF,FF,FF,FF,FF,00,2D,B2,00,12,00,00,00,00,FF,19,01,03,6E,34,20,78,EE,B3,25,AC,51,30,B4,26, 10,50,54,FF,FF,80,81,8F,81,99,A9,40,61,59,45,59,31,59,71,4A,81,40,01,1D,00,72,51,D0,1E,20,6E,28, 55,00,07,44,21,00,00,1E,00,00,00,FD,00,38,4C,1E,53,11,00,0A,20,20,20,20,20,20,00,00,00,FC,00,44, 49,50,2D,32,30,0A,20,20,20,20,20,20,02,3A,80,18,71,38,2D,40,58,2C,45,00,07,44,21,00,00,1E,00,AF

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 38 Protocol 3000 The DIP-20 Automatic Video Switcher can be operated using the Kramer Protocol 3000 serial commands. The command framing varies according to how you interface with the DIP-20. For example, a basic video input switching command that routes a layer 1 video signal to HDBT out 1 from HDMI input 2 (ROUTE 1,1,2), is entered as follows: • Terminal communication software, such as Hercules: The framing of the command varies according to the terminal communication software. • K-Touch Builder (Kramer software): • K-Config (Kramer configuration software): All the examples provided in this section are based on using the K-Config software. You can enter commands directly using terminal communication software (e.g., Hercules) by connecting a PC to the serial or Ethernet port on the DIP-20. To enter CR press the Enter key (LF is also sent but is ignored by the command parser). Commands sent from various non-Kramer controllers (e.g., Crestron) may require special coding for some characters (such as, /X##). For more information, refer to your controller’s documentation. For more information about:

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 39 • Using Protocol 3000 commands, see Understanding Protocol 3000 on page 39. • General syntax used for Protocol 3000 commands, see Kramer Protocol 3000 Syntax on page 40. • Protocol 3000 commands available for the DIP-20, see Protocol 3000 Commands on page 41. Understanding Protocol 3000 Protocol 3000 commands are structured according to the following: • Command – A sequence of ASCII letters (A-Z, a-z and -). A command and its parameters must be separated by at least one space. • Parameters – A sequence of alphanumeric ASCII characters (0-9, A-Z, a-z and some special characters for specific commands). Parameters are separated by commas. • Message string – Every command entered as part of a message string begins with a message starting character and ends with a message closing character. A string can contain more than one command. Commands are separated by a pipe (|) character. The maximum string length is 64 characters. • Message starting character: ▪ # – For host command/query ▪ ~ – For device response • Device address – K-NET Device ID followed by @ (optional, K-NET only) • Query sign – ? follows some commands to define a query request • Message closing character: ▪ CR – Carriage return for host messages (ASCII 13) ▪ CR LF – Carriage return for device messages (ASCII 13) and line-feed (ASCII 10) • Command chain separator character – Multiple commands can be chained in the same string. Each command is delimited by a pipe character (|). When chaining commands, enter the message starting character and the message closing character only at the beginning and end of the string. Spaces between parameters or command terms are ignored. Commands in the string do not execute until the closing character is entered. A separate response is sent for every command in the chain.

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 40 Kramer Protocol 3000 Syntax The Kramer Protocol 3000 syntax uses the following delimiters: • CR = Carriage return (ASCII 13 = 0x0D) • LF = Line feed (ASCII 10 = 0x0A) • SP = Space (ASCII 32 = 0x20) Some commands have short name syntax in addition to long name syntax to enable faster typing. The response is always in long syntax. The Protocol 3000 syntax is in the following format: • Host Message Format: Start Address (optional) Body Delimiter # Device_id@ Message CR • Simple Command – Command string with only one command without addressing: Start Body Delimiter # Command SP Parameter_1,Parameter_2,… CR • Command String – Formal syntax with command concatenation and addressing: Start Address Body Delimiter # Device_id@ Command_1 Parameter1_1,Parameter1_2,…| Command_2 Parameter2_1,Parameter2_2,…| Command_3 Parameter3_1,Parameter3_2,…|… CR • Device Message Format: Start Address (optional) Body Delimiter ~ Device_id@ Message CR LF • Device Long Response – Echoing command: Start Address (optional) Body Delimiter ~ Device_id@ Command SP [Param1,Param2 …] result CR LF

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 41 Protocol 3000 Commands This section includes the following commands: • System Commands (see System Commands on page 42) • Authentication Commands (see Authentication Commands on page 54) • Switching/Routing Commands (see Switching/Routing Commands on page 57) • Video Commands (see Video Commands on page 58) • Audio Commands (see Audio Commands on page 59) • Communication Commands (see Communication Commands on page 62) • EDID Handling Commands (see EDID Handling Commands on page 66)

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 42 System Commands Command Description # Protocol handshaking (system mandatory) BUILD-DATE Get device build date (system mandatory) FACTORY Reset to factory default configuration HELP Get command list (system mandatory) MODEL Get device model (system mandatory) PROT-VER Get device protocol version (system mandatory) RESET Reset device (system mandatory) SN Get device serial number (system mandatory) VERSION Get device firmware version (system mandatory) AV-SW-MODE Set/get auto switch mode (system) AV-SW-TIMEOUT Set/get auto switching timeout (system) DISPLAY Get output HPD status (system) DPSW-STATUS Get the DIP-switch status (system) FPGA-VER Get current FPGA version (system) HDCP-MOD Set/get HDCP mode (system) HDCP-STAT Get HDCP signal status (system) NAME Set/get machine (DNS) name (system – Ethernet) NAME-RST Reset machine (DNS) name to factory default (system – Ethernet) PRIORITY Set/get priority for all channels (system) SIGNAL Get input signal lock status (system) # Functions Permission Transparency Set: # End User Public Get: - - - Description Syntax Set: Protocol handshaking #CR Get: - - Response ~nn@SPOKCR LF Parameters Response Triggers Notes Validates the Protocol 3000 connection and gets the machine number Step-in master products use this command to identify the availability of a device K-Config Example “#”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 43 BUILD-DATE Functions Permission Transparency Set: - - - Get: BUILD-DATE? End User Public Description Syntax Set: - - Get: Get device build date #BUILD-DATE?CR Response ~nn@BUILD-DATESPdateSPtimeCR LF Parameters date – Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day time – Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds Response Triggers Notes K-Config Example “#BUILD-DATE?”,0x0D FACTORY Functions Permission Transparency Set: FACTORY End User Public Get: - - - Description Syntax Set: Reset device to factory default configuration #FACTORYCR Get: - - Response ~nn@FACTORYSPOKCR LF Parameters Response Triggers Notes This command deletes all user data from the device. The deletion can take some time. Your device may require powering off and powering on for the changes to take effect. K-Config Example “#FACTORY”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 44 HELP Functions Permission Transparency Set: - - - Get: HELP End User Public Description Syntax Set: - - Get: Get command list or help for specific command 1. #HELPCR 2. #HELPSPCOMMAND_NAMECR Response 1. Multi-line: ~nn@Device available protocol 3000 commands:CR LFcommand,SP command...CR LF 2. Multi-line: ~nn@HELPSPcommand:CR LFdescriptionCR LFUSAGE:usageCR LF Parameters COMMAND_NAME – name of a specific command Response Triggers Notes To get help for a specific command use: HELPSPCOMMAND_NAMECR LF K-Config Example “#HELP”,0x0D MODEL Functions Permission Transparency Set: - - - Get: MODEL? End User Public Description Syntax Set: - - Get: Get device model #MODEL?CR Response ~nn@MODELSPmodel_nameCR LF Parameters model_name – String of up to 19 printable ASCII chars Response Triggers Notes This command identifies equipment connected to Step-in master products and notifies of identity changes to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests K-Config Example “#MODEL?”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 45 PROT-VER Functions Permission Transparency Set: - - - Get: PROT-VER? End User Public Description Syntax Set: - - Get: Get device protocol version #PROT-VER?CR Response ~nn@PROT-VERSP3000:versionCR LF Parameters version - XX.XX where X is a decimal digit Response Triggers Notes K-Config Example “#PROT-VER?”,0x0D RESET Functions Permission Transparency Set: RESET Administrator Public Get: - - - Description Syntax Set: Reset device #RESETCR Get: - - Response ~nn@RESETSPOKCR LF Parameters Response Triggers Notes To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the port was locked, disconnect and reconnect the cable to reopen the port. K-Config Example “#RESET”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 46 SN Functions Permission Transparency Set: - - - Get: SN? End User Public Description Syntax Set: - - Get: Get device serial number #SN?CR Response ~nn@SNSPserial_numberCR LF Parameters serial_number – 11 decimal digits, factory assigned Response Triggers Notes This device has a 14 digit serial number, only the last 11 digits are displayed K-Config Example “#SN?”,0x0D VERSION Functions Permission Transparency Set: - - - Get: VERSION? End User Public Description Syntax Set: - - Get: Get firmware version number #VERSION?CR Response ~nn@VERSIONSPfirmware_versionCR LF Parameters firmware_version – XX.XX.XXXX where the digit groups are: major.minor.build version Response Triggers Notes K-Config Example “#VERSION?”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 47 AV-SW-MODE Functions Permission Transparency Set: Get: AV-SW-MODE? End user Public Description Syntax Set: Get: Get input auto switch mode (per output) #AV-SW-MODE?SPlayer,output_idCR Response ~nn@AV-SW-MODESPlayer,output_id,modeCR LF Parameters layer – 1 (video), 2 (audio) output_id – for video layer: 1 (HDBT Out), for audio layer: 1 (Audio Out) mode – 0 (manual), 1 (priority switch), 2 (last connected switch) Response Triggers Notes K-Config Example Get the input audio switch mode for HDBT Out: “#AV-SW-MODE? 1,1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 48 AV-SW-TIMEOUT Functions Permission Transparency Set: AV-SW-TIMEOUT End User Public Get: AV-SW-TIMEOUT? End User Public Description Syntax Set: Set auto switching timeout #AV-SW-TIMEOUTSPaction,time_outCR Get: Get auto switching timeout #AV-SW-TIMEOUT?SPactionCR Response ~nn@AV-SW-TIMEOUTSPaction,time_outCR Parameters action – event that triggers the auto switching timeout: 0 (video signal lost) 2 (audio signal lost) 4 (disable 5V on video output if no input signal detected) 5 (video cable unplugged) 6 (audio cable unplugged) timeout – timeout in seconds: 0-60000 Response Triggers Notes The timeout must not exceed 60000 seconds. The timeout for video and audio signal lost (0, 2) events must not be less than 5 seconds. The timeout for video and audio cable unplugged (5, 6) events must not exceed the timeout for the disable 5V on video output if no input signal detected (4) event. The timeout for the disable 5V on video output if no input signal detected (4) event must not be less than the timeout for video and audio cable unplugged (5, 6) events. The timeout for the disable 5V on video output if no input signal detected (4) event overlaps with the timeouts for all other events (0, 2, 5, 6). This does not apply to VGA input. K-Config Example Set the auto switching timeout to 5 seconds in the event of video signal lost: “#AV-SW-TIMEOUT 0,5”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 49 DISPLAY Functions Permission Transparency Set: - - - Get DISPLAY? End User Public Description Syntax Set: - - Get: Get output HPD status #DISPLAY?SPout_idCR Response ~nn@DISPLAYSPout_id,statusCR LF Parameters out_id – 1 (HDBT Out) status – HPD status according to signal validation : 0 (Off), 1 (On), 2 (On and all parameters are stable and valid) Response Triggers A response is sent to the com port from which the Get was received, after command execution and: After every change in output HPD status from On to Off (0) After every change in output HPD status from Off to On (1) After every change in output HPD status form Off to On and all parameters (new EDID, etc.) are stable and valid (2) Notes K-Config Example Get the output HPD status of HDBT Out: “#DISPLAY? 1”,0x0D DPSW-STATUS Functions Permission Transparency Set: - - - Get DPSW-STATUS? End User Public Description Syntax Set: - - Get: Get the DIP-switch status #DPSW-STATUS?SPdp_sw_idCR Response ~nn@DPSW-STATUS?SPdp_sw_id,statusCR LF Parameters Dp_sw_id – 1 (video switch), 2 (video switch), 3 (audio switch), 4 (audio switch) status – 0 (up / Off), 1 (down / On) Response Triggers Notes K-Config Example Get the status of DIP-switch 1 (video switch): “#DPSW-STATUS? 1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 50 FPGA-VER Functions Permission Transparency Set: - - - Get: FPGA-VER? End User Public Description Syntax Set: - - Get: Get current FPGA version #FPGA-VER?SPidCR Response ~nn@FPGA-VERSPid,major_ver,minor_verCR LF Parameters id – 1 (FPGA) major_ver – Major FPGA version number for current firmware minor_ver – Minor FPGA version number for current firmware Response Triggers Notes FPGA – field programmable gate array K-Config Example Get the FPGA version number for the current firmware: “#FPGA-VER? 1”,0x0D HDCP-MOD Functions Permission Transparency Set: HDCP-MOD Administrator Public Get: HDCP-MOD? End User Public Description Syntax Set: Set HDCP mode #HDCP-MODSPinp_id,modeCR Get: Get HDCP mode #HDCP-MOD?SPinp_idCR Response Set / Get: ~nn@HDCP-MODSPinp_id,modeCR LF Parameters inp_id – input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In) mode – HDCP mode: 0 (HDCP Off), 3 (Mirror output – MAC mode) Response Triggers A response is sent to the com port from which the set (before execution) / get command was received A response is sent to all com ports after command execution if HDCP-MOD was set by any other external control device (device button, device menu or other) or if the HDCP mode changed Notes Set HDCP working mode on the device input: HDCP not supported - HDCP Off HDCP support changes following detected sink - MIRROR OUTPUT K-Config Example Disable HDCP mode on HDMI In 2: “#HDCP-MOD 2,0”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 51 HDCP-STAT Functions Permission Transparency Set: - - - Get: HDCP-STAT? End User Public Description Syntax Set: - - Get: Get HDCP signal status #HDCP-STAT?SPstage,stage_idCR Response ~ nn@HDCP-STATSPstage,stage_id,statusCR LF Parameters stage – 0 (input), 1 (output) stage_id – for input stage: 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In), for output stage: 1 (HDBT Out) status – signal encryption status: 0 (On), 1 (Off) Response Triggers A response is sent to the com port from which the Get command was received Notes Output stage (1) – get the HDCP signal status of the sink device connected to HDBT Out Input stage (0) – get the HDCP signal status of the source device connected to the specified input K-Config Example Get the HDCP input signal status of the source device connected to HDMI In 1: “#HDCP-STAT? 0,1”,0x0D NAME Functions Permission Transparency Set: NAME Administrator Public Get: NAME? End User Public Description Syntax Set: Set machine (DNS) name #NAMESPmachine_nameCR Get: Get machine (DNS) name #NAME?CR Response Set: ~nn@NAMESPmachine_nameCR LF Get: ~nn@NAME?SPmachine_nameCR LF Parameters machine_name - String of up to 14 alpha-numeric characters (can include hyphens but not at the beginning or end) Response Triggers Notes The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use (with DNS feature on). K-Config Example Set the DNS name of the device to “room-442”: “#NAME room-442”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 52 NAME-RST Functions Permission Transparency Set: NAME-RST Administrator Public Get: - - - Description Syntax Set: Reset machine (DNS) name to factory default #NAME-RSTCR Get: - - Response ~nn@NAME-RSTSPOKCR LF Parameters Response Triggers Notes Factory default of machine (DNS) name is “KRAMER_” K-Config Example Reset the DNS name of the device to the factory default: “#NAME-RST”,0x0D PRIORITY Functions Permission Transparency Set: PRIORITY Administrator Public Get: PRIORITY? Administrator Public Description Syntax Set: Set input priority #PRIORITYSPlayer,PRIORITY1,PRIORITY2, PRIORITY3CR Get: Get input priority # PRIORITY?layerCR Response ~nn@PRIORITYSPlayer,PRIORITY1,PRIORITY2,PRIORITY3CR LF Parameters layer – 1 (video): PRIORITY1 - priority of HDMI In 1: 1 (highest priority), 2 (second priority), 3 (third priority) PRIORITY2 - priority of HDMI In 2: 1 (highest priority), 2 (second priority), 3 (third priority) PRIORITY3 - priority of PC In: 1 (highest priority), 2 (second priority), 3 (third priority) layer – 2 (audio): PRIORITY1 - priority of embedded audio: 1 (highest priority), 2 (second priority) PRIORITY2 - priority of Audio In: 1 (highest priority), 2 (second priority) Response Triggers Notes The number of PRIORITY parameters differs according to the selected layer 1 is the highest priority K-Config Example Set the video input priority of PC In as the highest priority: “#PRIORITY 1,2,3,1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 53 SIGNAL Functions Permission Transparency Set: - - - Get SIGNAL? End User Public Description Syntax Set: - - Get: Get input signal lock status #SIGNAL?SPinp_idCR Response ~nn@SIGNALSPinp_id,statusCR LF Parameters inp_id – input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In) status – lock status according to signal validation: 0 (Off), 1 (On) Response Triggers After execution, a response is sent to the com port from which the Get was received A response is sent after every change in input signal status from On to Off or from Off to On Notes K-Config Example Get the input signal lock status of HDMI In 2: “#SIGNAL? 2”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 54 Authentication Commands Command Description LOGIN Set/get protocol permission LOGOUT Cancel current permission level PASS Set/get password for login level SECUR Set/get current security state LOGIN Functions Permission Transparency Set: LOGIN Not Secure Public Get: LOGIN? Not Secure Public Description Syntax Set: Set protocol permission #LOGINSPlogin_level,passwordCR Get: Get current protocol permission level #LOGIN?CR Response Set: ~nn@LOGINSPlogin_level,passwordSPOKCR LF or ~nn@LOGINSPERRSP004CR LF (if bad password entered) Get: ~nn@LOGINSPlogin_levelCR LF Parameters login_level – level of permissions required: User, Admin password – predefined password (by PASS command). Default password is an empty string Response Triggers Notes When the permission system is enabled, LOGIN enables running commands with the User or Administrator permission level When set, login must be performed upon each connection The permission system works only if security is enabled with the SECUR command. It is not mandatory to enable the permission system in order to use the device K-Config Example Set the protocol permission level to Admin (when the password defined in the PASS command is 33333): “#LOGIN Admin,33333”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 55 LOGOUT Functions Permission Transparency Set: LOGOUT Not Secure Public Get: - - - Description Syntax Set: Cancel current permission level #LOGOUTCR Get: - - Response ~nn@LOGOUTSPOKCR LF Parameters Response Triggers Notes Logs out from User or Administrator permission levels K-Config Example “#LOGOUT”,0x0D PASS Functions Permission Transparency Set: PASS Administrator Public Get: PASS? Administrator Public Description Syntax Set: Set password for login level #PASSSPlogin_level,passwordCR Get: Get password for login level #PASS?SPlogin_levelCR Response ~nn@PASSSPlogin_level,passwordCR LF Parameters login_level – level of login to set: User, Admin password – password for the login_level. Up to 15 printable ASCII chars. Response Triggers Notes The default password is an empty string K-Config Example Set the password for the Admin protocol permission level to 33333: “#PASS Admin,33333”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 56 SECUR Functions Permission Transparency Set: SECUR Administrator Public Get: SECUR? Not Secure Public Description Syntax Set: Start/stop security #SECURSPsecurity_modeCR Get: Get current security state #SECUR?CR Response ~nn@SECURSPsecurity_modeCR LF Parameters security_mode – 1 (On / enable security), 0 (Off / disable security) Response Triggers Notes The permission system works only if security is enabled with the SECUR command K-Config Example Enable the permission system: “#SECUR 0”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 57 Switching/Routing Commands Command Description ROUTE Set/get layer routing ROUTE Functions Permission Transparency Set: ROUTE End User Public Get: ROUTE? End User Public Description Syntax Set: Set layer routing #ROUTESPlayer,dest,srcCR Get: Get layer routing #ROUTE?SPlayer,destCR Response ~nn@ROUTESPlayer,dest,srcCR LF Parameters layer – 1 (video), 3 (data) dest – for video layer: 1 (HDBT Out), for data layer: 1 (HDBT data port), 2 (DIP-20 data port), 3 (DIP-20 internal control port) src – for video layer: 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In), for data layer: 1 (HDBT data port), 2 (DIP-20 data port), 3 (DIP-20 internal control port) Response Triggers Notes The get command identifies input switching on Step-in clients The set command is for remote input switching on Step-in clients (essentially via by the Web) K-Config Example Set the remote input switching of data to control mode: “#ROUTE 3,1,3”,0x0D Set the remote input switching of data to data mode: “#ROUTE 3,1,2”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 58 Video Commands Command Description VGA-PHASE Set/get ADC (VGA) sampling phase VMUTE Set/get video on output mute VGA-PHASE Functions Permission Transparency Set: VGA-PHASE End User Public Get: VGA-PHASE? End User Public Description Syntax Set: Set ADC (VGA) sampling phase #VGA-PHASESPchannel,valueCR Get: Get ADC (VGA) sampling phase #VGA-PHASE?SPchannelCR Response ~nn@VGA-PHASESPchannel,valueCR LF Parameters channel – input number: 3 (PC In) value – phase number in LSB units: 1-30, ++ (increase current value), -- (decrease current value) Response Triggers Notes K-Config Example Increase the current value of the ADC (VGA) sampling phase: “#VGA-PHASE 3,++”,0x0D VMUTE Functions Permission Transparency Set: VMUTE End User Public Get: VMUTE? End User Public Description Syntax Set: Set enable/disable video on output #VMUTESPoutput_id,flagCR Get: Get video on output status #VMUTE?SPoutput_idSP CR Response Set / Get: ~nn@VMUTESPoutput_id,flagCR LF Parameters output_id – 1 (HDBT Out) flag – 0 (disable video on output), 1 (enable video on output), 2 (blank video) Response Triggers Notes K-Config Example Disable the video output on HDBT Out: “#VMUTE 3,0”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 59 Audio Commands Command Description AUD-EMB Get audio in video embedding status AUD-LVL Set/get volume for specific amplifier output AUD-SIGNAL? Get audio input signal status MUTE Set/get audio mute AUD-EMB Functions Permission Transparency Set: Get: AUD-EMB? End User Public Description Syntax Set: Get: Get audio in video embedding status #AUD-EMB?SPin,outCR Response ~nn@AUD-EMBSPin,out,statusCR LF Parameters in – embedded audio input number: 1 (Audio In) out – video output number in which audio is embedded: 1 (HDBT Out) status – embedded status: 1 (On), 0 (Off) Response Triggers A response is sent to the com port from which the get command was received After execution, a response is sent to all com ports if AUD-EMB was set by any other external control device (button press, device menu and similar) Notes K-Config Example “#AUD-EMB? 1,1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 60 AUD-LVL Functions Permission Transparency Set: AUD-LVL End User Public Get: AUD-LVL? End User Public Description Syntax Set: Set volume for specific amplifier output #AUD-LVLSPstage,channel,volumeCR Get: Get volume for specific amplifier output #AUD-LVL?SPstage,channelCR Response ~nn@AUD-LVLSPstage,channel,volumeCR LF Parameters stage – 1 (audio output) channel – output channel number of selected stage: 1 (Audio Out) volume – audio parameter percentage: 0-100 (percent value), ++ (increase current value by 1 percent), -- decrease current value by 1 percent Response Triggers Notes All values are in percentages A minus sign precedes negative values K-Config Example Set the volume of the Audio Out (1) output to 75%: “#AUD-LVL 1,1,75”,0x0D AUD-SIGNAL Functions Permission Transparency Set: - - - Get AUD-SIGNAL? End User Public Description Syntax Set: - - Get: Get audio input signal status # AUD-SIGNAL?SPinp_idCR Response ~nn@AUD-SIGNALSPinp_id,statusCR LF Parameters inp_id – audio input number: 1 (Audio In) status – 0 (Off / no signal), 1 (On / signal present) Response Triggers After execution, a response is sent to the com port from which the get command was received A response is sent to all com ports if the audio status was changed on any input Notes K-Config Example “#AUD-SIGNAL? 1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 61 MUTE Functions Permission Transparency Set: MUTE End User Public Get: MUTE? End User Public Description Syntax Set: Set audio mute #MUTESPchannel,mute_modeCR Get: Get audio mute #MUTE?SPchannelCR Response ~nn@MUTESPchannel, mute_modeCR LF Parameters channel – audio output number: 1 (Audio Out) mute_mode – 0 (Off), 1 (On) Response Triggers Notes K-Config Example Mute the Audio Out output: “#MUTE 1,1”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 62 Communication Commands Command Description ETH-PORT Set/get Ethernet port protocol NET-DHCP Set/get DHCP mode NET-GATE Set/get gateway IP NET-IP Set/get IP address NET-MAC Get MAC address NET-MASK Set/get subnet mask ETH-PORT Functions Permission Transparency Set: ETH-PORT Administrator Public Get: ETH-PORT? End User Public Description Syntax Set: Set Ethernet port protocol #ETH-PORTSPportType,ETHPortCR Get: Get Ethernet port protocol #ETH-PORT?SPportTypeCR Response ~nn@ETH-PORTSPportType,ETHPortCR LF Parameters portType – string of 3 letters indicating the port type: TCP, UDP ETHPort – TCP / UDP port number: 0-65565 Response Triggers Notes If the port number you enter is already in use, an error is returned The port number must be within the following range: 0-(2^16-1) K-Config Example Set the Ethernet port protocol for TCP to port 12457: “#ETH-PORT TCP,12457”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 63 NET-DHCP Functions Permission Transparency Set: NET-DHCP Administrator Public Get: NET-DHCP? End User Public Description Syntax Set: Set DHCP mode #NET-DHCPSPmodeCR Get: Get DHCP mode #NET-DHCP?CR Response ~nn@NET-DHCPSPmodeCR LF Parameters mode – 0 (do not use DHCP. Use the IP address set by the factory or the NET-IP command), 1 (try to use DHCP. If unavailable, use the IP address set by the factory or the NET-IP command) Response Triggers Notes Connecting Ethernet to devices with DHCP may take more time in some networks To connect with a randomly assigned IP by DHCP, specify the device DNS name (if available) using the NAME command. You can also get an assigned IP by direct connection to USB or RS-232 protocol port if available Consult your network administrator for correct settings K-Config Example Enable DHCP mode, if available: “#NET-DHCP 1”,0x0D NET-GATE Functions Permission Transparency Set: NET-GATE Administrator Public Get: NET-GATE? End User Public Description Syntax Set: Set gateway IP #NET-GATESPip_addressCR Get: Get gateway IP #NET-GATE?CR Response ~nn@NET-GATESPip_addressCR LF Parameters ip_address – gateway IP address, in the following format: xxx.xxx.xxx.xxx Response Triggers Notes A network gateway connects the device via another network, possibly over the Internet. Be careful of security problems. Consult your network administrator for correct settings. K-Config Example Set the gateway IP address to 192.168.0.1: “#NET-GATE 192.168.000.001”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 64 NET-IP Functions Permission Transparency Set: NET-IP Administrator Public Get: NET-IP? End User Public Description Syntax Set: Set IP address #NET-IPSPip_addressCR Get: Get IP address #NET-IP?CR Response ~nn@NET-IPSPip_addressCR LF Parameters ip_address – IP address, in the following format: xxx.xxx.xxx.xxx Response Triggers Notes Consult your network administrator for correct settings K-Config Example Set the IP address to 192.168.1.39: “#NET-IP 192.168.001.039”,0x0D NET-MAC Functions Permission Transparency Set: - - - Get: NET-MAC? End User Public Description Syntax Set: - - Get: Get MAC address #NET-MAC?CR Response ~nn@NET-MACSPmac_addressCR LF Parameters mac_address – unique MAC address. Format: XX-XX-XX-XX-XX-XX where X is hex digit Response Triggers Notes K-Config Example “#NET-MAC?”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 65 NET-MASK Functions Permission Transparency Set: NET-MASK Administrator Public Get: NET-MASK? End User Public Description Syntax Set: Set subnet mask #NET-MASKSPnet_maskCR Get: Get subnet mask #NET-MASK?CR Response ~nn@NET-MASKSPnet_maskCR LF Parameters net_mask - format: xxx.xxx.xxx.xxx Response Triggers The subnet mask limits the Ethernet connection within the local network Consult your network administrator for correct settings Notes K-Config Example Set the subnet mask to 255.255.0.0: “#NET-MASK 255.255.000.000”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 66 EDID Handling Commands Additional EDID data functions can be performed via the DIP-20 web pages or a compatible EDID management application, such as Kramer EDID Designer (see www.kramerav.com/product/DIP-20). Command Description CPEDID Copy EDID data from the output to the input EEPROM LOCK-EDID Lock last read EDID CPEDID Functions Permission Transparency Set: CPEDID End User Public Get: - - - Description Syntax Set: Copy EDID data from the output to the input EEPROM #CPEDIDSPsrc_type,src_id,dst_type, dest_bitmapCR Get: - - Response ~nn@CPEDIDSPsrc_type,src_id,dst_type,dest_bitmapCR LF Parameters src_type – EDID source type (usually output): 0 (input), 1 (output), 2 (default EDID) src_id – for input source: 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In), for output source: 1 (HDBT Out), for default EDID source: 0 (default EDID) dst_type – EDID destination type (usually input): 0 (input), 1 (output), 2 (default EDID) dest_bitmap – bitmap representing destination IDs. Format: XXXX…X, where X is hex digit. The binary form of every hex digit represents corresponding destinations. Setting ‘1’ indicates that EDID data is copied to this destination. Setting ‘0’ indicates that EDID data is not copied to this destination. Response Triggers Response is sent to the com port from which the Set was received (before execution) Notes Destination bitmap size depends on device properties (for 64 inputs it is a 64-bit word) Example: bitmap 0x0013 means inputs 1, 2 and 5 are loaded with the new EDID. In this device, if the destination type is input (0), the bitmap size is 3 bits, for example bitmap 0x5 means inputs 1 and 3 are loaded with the new EDID. K-Config Example Copy the EDID data from the HDBT Out output (EDID source) to the HDMI In 1 input: “#CPEDID 1,1,0,0x1”,0x0D Copy the EDID data from the default EDID source to HDMI In 1 and PC In inputs: “#CPEDID 2,0,0,0x5”,0x0D

Kramer Electronics Ltd.

DIP-20 – Protocol 3000 67 LOCK-EDID Functions Permission Transparency Set: LOCK-EDID End User End User Get: LOCK-EDID? End User End User Description Syntax Set: Lock last read EDID #LOCK-EDIDSPinput_id,lock_modeCR Get : Get EDID lock state #LOCK-EDID?SPinput_idCR Response ~nn@LOCK-EDIDSPinput_id,lock_modeCR LF Parameters input_id – 1 (HDMI In 1), 2 (HDMI In 2), 3 (PC In), lock_mode – 0 (Off: unlocks EDID), 1 (On: locks EDID) Response Triggers Notes K-Config Example Lock the last read EDID from the HDMI In 2 input: “#LOCK-EDID 2,1”,0x0D

The warranty obligations of Kramer Electronics Inc. (“Kramer Electronics”) for this product are limited to the terms set forth below:

What is Covered This limited warranty covers defects in materials and workmanship in this product. What is Not Covered This limited warranty does not cover any damage, deterioration or malfunction resulting from any alteration, modification, improper or unreasonable use or maintenance, misuse, abuse, accident, neglect, exposure to excess moisture, fire, improper packing and shipping (such claims must be presented to the carrier), lightning, power surges, or other acts of nature. This limited warranty does not cover any damage, deterioration or malfunction resulting from the installation or removal of this product from any installation, any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this product. This limited warranty does not cover cartons, equipment enclosures, cables or accessories used in conjunction with this product. Without limiting any other exclusion herein, Kramer Electronics does not warrant that the product covered hereby, including, without limitation, the technology and/or integrated circuit(s) included in the product, will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used. How Long this Coverage Lasts The standard limited warranty for Kramer products is seven (7) years from the date of original purchase, with the following exceptions: 1. All Kramer VIA hardware products are covered by a standard three (3) year warranty for the VIA hardware and a standard three (3) year warranty for firmware and software updates. 2. All Kramer fiber optic cables, adapter-size fiber optic extenders, active cables, cable retractors, all Kramer speakers and Kramer touch panels are covered by a standard one (1) year warranty. 3. All Kramer Cobra products, all Kramer Calibre products, all Kramer Minicom digital signage products, all HighSecLabs products, all streaming, and all wireless products are covered by a standard three (3) year warranty. 4. All Sierra Video MultiViewers are covered by a standard five (5) year warranty. 5. Sierra switchers & control panels are covered by a standard seven (7) year warranty (excluding power supplies and fans that are covered for three (3) years). 6. K-Touch software is covered by a standard one (1) year warranty for software updates. 7. All Kramer passive cables are covered by a ten (10) year warranty. Who is Covered Only the original purchaser of this product is covered under this limited warranty. This limited warranty is not transferable to subsequent purchasers or owners of this product. What Kramer Electronics Will Do Kramer Electronics will, at its sole option, provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty: 1. Elect to repair or facilitate the repair of any defective parts within a reasonable period of time, free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition. Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete. 2. Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product. 3. Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty. What Kramer Electronics Will Not Do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products, this product must be insured during shipment, with the insurance and shipping charges prepaid by you. If this product is returned uninsured, you assume all risks of loss or damage during shipment. Kramer Electronics will not be responsible for any costs related to the removal or re- installation of this product from or into any installation. Kramer Electronics will not be responsible for any costs related to any setting up this product, any adjustment of user controls or any programming required for a specific installation of this product. How to Obtain a Remedy Under This Limited Warranty To obtain a remedy under this limited warranty, you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you. For a list of authorized Kramer Electronics resellers and/or Kramer Electronics authorized service providers, visit our web site at www.kramerav.com or contact the Kramer Electronics office nearest you. In order to pursue any remedy under this limited warranty, you must possess an original, dated receipt as proof of purchase from an authorized Kramer Electronics reseller. If this product is returned under this limited warranty, a return authorization number, obtained from Kramer Electronics, will be required (RMA number). You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product. If it is decided that this product should be returned directly to Kramer Electronics, this product should be properly packed, preferably in the original carton, for shipping. Cartons not bearing a return authorization number will be refused. Limitation of Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY. Some countries, districts or states do not allow the exclusion or limitation of relief, special, incidental, consequential or indirect damages, or the limitation of liability to specified amounts, so the above limitations or exclusions may not apply to you. Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW, THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW, THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPLICABLE LAW. IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A “CONSUMER PRODUCT” UNDER THE MAGNUSON-MOSS WARRANTY ACT (15 U.S.C.A. §2301, ET SEQ.) OR OTHER APPLICABLE LAW, THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU, AND ALL IMPLIED WARRANTIES ON THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE, SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW. Other Conditions This limited warranty gives you specific legal rights, and you may have other rights which vary from country to country or state to state. This limited warranty is void if (i) the label bearing the serial number of this product has been removed or defaced, (ii) the product is not distributed by Kramer Electronics or (iii) this product is not purchased from an authorized Kramer Electronics reseller. If you are unsure whether a reseller is an authorized Kramer Electronics reseller, visit our web site at www.kramerav.com or contact a Kramer Electronics office from the list at the end of this document. Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form. Kramer Electronics thanks you for purchasing a Kramer Electronics product. We hope it will give you years of satisfaction.