Marson MT10 Integration Manual
Text of the manual
MT10 Linear Image Barcode Scan Engine, Integration Guide, V1.9
MT10
MT10
(3.3V
(3.3V Linear
Linear Image
Image Barcode
Barcode Scan
Scan Engine)
Engine)
Integration
Integration Guide
Guide
Version 1.9
DATE: 2018/09/03
MT10 Linear Image Barcode Scan Engine, Integration Guide, V1.9
TABLE OF CONTENTS
1.
1. INTRODUCTION
INTRODUCTION.....................................................................................................11
1-1.
1-1. MT10
MT10 Block
Block Diagram
Diagram................................................................................ 11
1-2.
1-2. Electric
Electric Interface
Interface........................................................................................22
1-2-1.
1-2-1. Pin
Pin Assignment
Assignment.............................................................................. 22
1-2-2.
1-2-2. Electric
Electric Characteristics
Characteristics................................................................55
1-2-3.
1-2-3. Flex
Flex Cable
Cable........................................................................................ 55
1-3.
1-3. Operational
Operational Timing
Timing................................................................................... 66
1-3-1.
1-3-1. Power
Power Up
Up..........................................................................................66
1-3-2.
1-3-2. Sleep
Sleep (Idle)
(Idle) Mode
Mode........................................................................... 66
1-3-3.
1-3-3. Decode
Decode Timing
Timing................................................................................66
1-3-4.
1-3-4. Summary
Summary of
of Operation
Operation Timings
Timings.................................................77
2.
2. SPECIFICATIONS
SPECIFICATIONS.................................................................................................. 77
2-1.
2-1. Introduction
Introduction................................................................................................ 77
2-2.
2-2. Technical
Technical Specifications
Specifications......................................................................... 77
2-3.
2-3. Interface
Interface....................................................................................................... 99
2-3-1.
2-3-1. UART
UART Interface
Interface............................................................................... 99
2-3-2.
2-3-2. USB
USB Interface
Interface................................................................................10
10
2-4.
2-4. Operation
Operation Method
Method....................................................................................11
11
2-5.
2-5. Mechanical
Mechanical Dimension
Dimension...........................................................................11
11
2-6.
2-6. Scanning
Scanning Range
Range...................................................................................... 12
12
2-6-1.
2-6-1. Typical
Typical Scanning
Scanning Range
Range............................................................ 12
12
2-6-2.
2-6-2. Guaranteed
Guaranteed Scanning
Scanning Range
Range................................................... 13
13
2-7.
2-7. Pitch
Pitch Angle,
Angle, Roll
Roll Angle
Angle and
and Skew
Skew Angle
Angle.......................................... 14
14
2-8.
2-8. Specular
Specular Dead
Dead Zone
Zone............................................................................... 15
15
2-9.
2-9. Curvature
Curvature Degree
Degree.................................................................................... 16
16
2-10.
2-10. Flex
Flex Cable
Cable Specification
Specification..................................................................... 16
16
2-11.
2-11. Connector
Connector Specification
Specification......................................................................17
17
3.
3. INSTALLATION
INSTALLATION.................................................................................................... 18
18
3-1.
3-1. Electrostatic
Electrostatic Discharge
Discharge Cautions
Cautions.......................................................18
18
3-2.
3-2. Mechanical
Mechanical Dimension
Dimension.......................................................................... 18
18
3-3.
3-3. Window
Window Materials
Materials....................................................................................19
19
3-4.
3-4. Window
Window Specifications
Specifications.......................................................................... 20
20
3-5.
3-5. Window
Window Care
Care............................................................................................ 22
22
4.
4. REGULATIONS
REGULATIONS.................................................................................................... 22
22
5.
5. DEVELOPMENT
DEVELOPMENT KIT
KIT........................................................................................... 23
23
6.
6. SLEEP
SLEEP (IDLE)
(IDLE) MODE
MODE.......................................................................................... 24
24
7.
7. PARAMETER
PARAMETER SETUP
SETUP..........................................................................................25
25
8.
8. VERSION
VERSION HISTORY
HISTORY............................................................................................ 26
26
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
1
1.
1. INTRODUCTION
INTRODUCTION
The MT10 Linear Image Barcode Scan Engine is designed for 1D barcode middle
range reading, and high performance barcode scanning with optimal performance and
easy integration. MT10 is ideal for integration into data terminals and other small
mobile devices.
The MT10 consists of 2 illumination LEDs, a high-quality linear image sensor and a
microprocessor that contains powerful firmware to control all aspects of operations
and enable communication with the host system over the standard set of
communication interfaces.
Two interfaces, UART & USB, are available. UART interface communicates with the
host system over TTL-level RS232 communication; USB interface emulates a USB
Keyboard device and communicates with the host system over USB.
1-1
1-1.. MT10
MT10 Block
Block Diagram
Diagram
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
2
1-
1-22.. Electric
Electric Interface
Interface
1-2-1.
1-2-1. Pin
Pin Assignment
Assignment
(Back View of MT10)
Pin#
UART
USB
I/O
Description
Schematic Example
1
VCC
VCC
------------
Supply voltage input.
Must always be
connected to a 3.3V
power supply.
+3V3
2
GND
GND
------------
Power and signal
ground.
3
RXD
------------
Input
UART TTL data input.
Sipex® Vendor P/N: SP232ACT
4
TXD
------------
Output
UART TTL data output.
Sipex® Vendor P/N: SP232ACT
Pin13
Pin1
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
3
Pin#
UART
USB
I/O
Description
Schematic Example
5
CTS
Input
When handshaking is
enabled, host
authorizes MT10 to
transmit data on TXD
line.
Sipex® Vendor P/N: SP232ACT
USB D+
Bidirectional Differential Signal
Transmission
------------------------------------------
6
RTS
Output
When handshaking is
enabled, MT10
requests permission
from host to transmit
data on TXD line.
Sipex® Vendor P/N: SP232ACT
USB D-
Bidirectional Differential Signal
Transmission
------------------------------------------
7
Power
down
Power
down
Output
Active high, it indicates
that the MT10 is in
Sleep Mode (See
Chapter 6 for details)
------------------------------------------
8
Buzzer
Buzzer
Output
Active high: Power-Up
or a successful
barcode decoded.
PWM controlled signal
can be used to drive an
external buzzer for a
successful barcode
decoded (Good Read).
R3
10R
Buzzer
Q1
2N3904
Q2
2N3904
R6
2K7
R7
6K8
R8
3K3
BZ
BZ1
BZ_2.7K
2
1
HD1
1N 4148
1
2
+ C8
10uF
+
-
VCC
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
4
Pin#
UART
USB
I/O
Description
Schematic Example
9
LED
LED
Output
Active high, it indicates
the status of Power-Up
or a successful
barcode decoded
(Good Read).
LED1
GREEN
1
2
Q4
2N3904
R11
330R
R13
4K7
Decode LED
VCC
10
Boot 0
Boot 0
Input
Reserved for
production only.
------------------------------------------
11
Trigger
Trigger
Input
High: Power-up/Standby
Low: Scanning Operation
*Note:
1. Scanning operation
continues until a barcode
is successfully decoded
or the trigger is released
(pull high). To proceed to
the next scanning
operation, release (pull
high) first and press (pull
low) the trigger again.
2. Pull low at power-up
will prompt the scan
engine into firmware
update mode.
12
Reset
Reset
Input
Reserved for
production only.
------------------------------------------
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
5
1-2-2.
1-2-2. Electric
Electric Characteristics
Characteristics
Symbol
Ratings
Min
Max
Unit
VIH
Input high level
2.0
3.6
V
VIL
Input low level
0
1.1
V
VOH
Output high level
2.9
V
VOL
Output low level
0.4
V
|△VDDx|
Variations between different VDD
power pins
50
mV
*Note:
1. Power Supply: VDD=3.3
2. Exposure to maximum rating conditions for extended periods may affect device reliability.
1-2-
1-2-33.. Flex
Flex Cable
Cable
The flex cable is used to connect MT10 to the host side. There are 13
pins on the MT10 (engine) side and 12 pins on the host side. Please
see 2-10 for more details of flex cable.
Flex cable
(P/N: 6351-0501113)
Pin#
Pin Assignment To Host
1
VCC
2
GND
3
RXD
4
TXD
5
USB D+ / CTS
6
USB D- / RTS
7
Power Down
8
Buzzer
9
LED
10
Boot0
11
Trigger
12
Reset
*Note: Conforms to MARSON MT700/MT710D’s pin assignment.
1
12
12
1
(contact)
(contact)
Host
Engine
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
6
1-3.
1-3. Operational
Operational Timing
Timing
This chapter describes the timing associated with the various operating modes of
the MT10 including Power Up, Sleep Mode, and Decode Timing.
1-3-
1-3-11.. Power
Power Up
Up
When power is initially applied, the MT10 is activated and begins the
process of initialization. Once initialization (duration ≦ 10mS) is
completed, the MT10 enters Standby Mode and is ready for barcode
scanning.
1-3-
1-3-22.. Sleep
Sleep (Idle)
(Idle) Mode
Mode
The MT10 will enter Sleep (Idle) Mode and output a Power Down signal
(Active high) after a programmable time period has elapsed without any
activity. Please see Chapter 6 for more details about Sleep Mode.
1-3-
1-3-33.. Decode
Decode Timing
Timing
In Standby Mode, The MT10 is activated by the Trigger signal which MUST
be kept low for at least 20 ms until the successful scan is achieved, as
indicated by the Buzzer/LED signals.
In Sleep Mode, the MT10 can be waken up by the Trigger signal which
MUST be kept low for at least 20 mS until the successful scan is achieved,
as indicated by the Buzzer/LED signal.
The total scan and decode time is approximately equal to the time from the
Trigger signal going low to the Buzzer/LED signal going high. This time will
vary slightly based on several factors including barcode quality, barcode
type and the distance between MT10 and the barcode scanned.
Upon a successful scan, the MT10 outputs the Buzzer/LED signal and
keeps this signal for the duration of the transmission of the data decoded to
the host side. The duration is about 75 ms.
Therefore, the total duration of a typical scanning operation (from Trigger
turning low to the end of Buzzer PWM signal) is also approximately 120mS.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
7
1-3-
1-3-44.. Summary
Summary of
of Operation
Operation Timings
Timings
1. The maximum duration of initialization is 10mS.
2. The maximum duration of scanning operation in Standby Mode is 120mS.
3. The minimum duration of waking up MT10 from Sleep Mode by
Trigger signal is about 2 ms.
4. The maximum duration of waking up MT10 from Sleep Mode by Trigger
signal and completing decode (when barcode is within optimal focus) is
about 120ms
2.
2. SPECIFICATIONS
SPECIFICATIONS
2-1.
2-1. Introduction
Introduction
This chapter provides technical specifications of the MT10 scan engine.
Operating method, scanning range and scan angle are also presented.
2-2.
2-2. Technical
Technical Specifications
Specifications
Optic & Performance
Light Source
625nm visible red LED
Sensor
Linear Image Sensor
Scan Rate
650 Scans/ sec
Resolution
4mil/ 0.1mm
Scan Angle
41°
Print Contrast Ratio
30%
Width of Field
140mm (13Mil Code39)
Typical
Depth Of Field
(Environment: 800 lux)
4 Mil Code39: 36 ~ 70mm (4 digits)
5 Mil Code39: 30 ~ 95mm (4 digits)
10 Mil Code39: 21 ~ 201mm (4 digits)
15 Mil Code39: 35 ~ 285mm (4 digits)
13 Mil UPC/ EAN: 34 ~ 239mm (13 digits)
Guaranteed
Depth Of Field
(Environment: 800 lux)
4 Mil Code39: 45 ~ 70mm (4 digits)
5 Mil Code39: 40 ~ 95mm (4 digits)
10 Mil Code39: 35 ~ 195mm (4 digits)
15 Mil Code39: 45 ~ 275mm (4 digits)
13 Mil UPC/ EAN: 40 ~ 230mm (13 digits)
Physical Characteristics
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
8
Dimension
W14 x L11.9 x H7 mm
Weight
1g
Color
Black
Material
PC
Cable
13pin to 12pin flex cable
Electrical
Operation Voltage
3.3VDC±0.15VDC
Working Current
< 75mA (UART) ; < 85mA (USB)
Standby Current
< 35mA (UART) ; < 45mA (USB)
Idle Current
(Sleep Mode)
< 300uA (UART) ; < 500uA (USB)
Surge Current
< 500 mA
Connectivity
Interface
UART (TTL-level RS232)
USB (HID Keyboard)
User Environment
Operating Temperature
-20°C ~ 60°C
Storage Temperature
-20°C ~ 60°C
Humidity
0% ~ 95%RH (Non-condensing)
Drop Durability
1.5M ()
Ambient Light
100,000 Lux (Sunlight)
Symbologies
UPC-A/ UPC-E
EAN-8/ EAN-13
Matrix 2 of 5
China Postal Code (Toshiba Code)
Industrial 2 of 5
Interleaved 2 of 5
Standard 2 of 5 (IATA Code)
Codabar
Code 11
Code 32
Standard Code 39
Full ASCII Code 39
Code 93
Code 128
EAN/ UCC 128
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
9
MSI Plessey Code
UK Plessey Code
Telepen Code
GS1 Databar
Regulatory
ESD
Functional after 4KV contact, 8KV air discharge
(it requires housing that is designed for ESD
protection and stray from electric fields.)
EMC
FCC – Part15 Subpart B (Class B)
CE – EN55022, EN55024
Safety Approval
IEC 62471 (Exempt Group)
Environmental
WEEE, RoHS 2.0
2-
2-33.. Interface
Interface
2-3-1.
2-3-1. UART
UART Interface
Interface
Below default values of communication parameters apply to both
Standard mode and Command mode firmware.
Baud rate: 9600
Data Bits: 8
Parity: None
Stop Bit: 1
Handshaking: None
Flow Control Timeout: None
ACK/NAK: OFF
BCC: OFF
A. Standard Mode
Firmware version: SM3-d-x.xx (MT10 P/N: 110P-A000000)
Characteristics:
(1) Configurable by scanning configuration barcodes or
Ez Utility® (a PC-based software utility, available for download at
www.marson.com.tw)
(2) Supports hardware trigger only
Interface Configuration Barcode:
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
10
UART
Scanning above barcode will set your MT10 to UART interface.
B. Command Mode
Firmware version: SM3-d-x.xx.CMD (MT10 P/N: 110P-4000000)
Characteristics:
(1) Configurable by commands sent from host or
BEO® (a PC-based software utility, available for download at
www.marson.com.tw)
(2) Supports both hardware and software triggers
Interface Configuration Barcode:
Not supported.
2-3-2.
2-3-2. USB
USB Interface
Interface
Firmware version: SM3-d-x.xx (MT10 P/N: 110P-A000000)
Characteristics:
(1) Configurable by scanning configuration barcodes or
Ez Utility® (a PC-based software utility, available for download at
www.marson.com.tw)
(2) Supports hardware trigger only
(3) Emulates a USB Keyboard device
Interface Configuration Barcode:
USB HID
Scanning above barcode will set your MT10 to USB interface.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
11
22--4.
4. Operat
Operation
ion Method
Method
1.
At power-up, the MT10 sends the Power-Up signals over Buzzer and LED
pins as an indication that the MT10 enters into Standby Mode and is ready
for operation.
2.
Once the MT10 triggered by either hardware or software method, it will emit a
narrow, horizontal slab of light which is aligned with the sensor’s field of view.
3.
The linear image sensor captures the linear image of barcode and produces
an analog waveform, which is sampled and analyzed by the decoder
firmware running on the MT10.
4.
Upon a successful barcode decoded, the MT10 turns off the illumination
LEDs, sends the Good Read signals over Buzzer and LED pins and transmits
the decoded data to the host.
5.
The MT10 may enter into Sleep Mode (Please see Chapter 6 for more
details) after a period of inactivity in order to reduce power consumption.
2-
2-55.. Mechanical
Mechanical Dimension
Dimension
Front View
Side View
Top View
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
12
2-
2-66.. SScanning
canning RRange
ange
2-
2-66-1
-1.. Typical
Typical SScanning
canning RRange
ange
Test Condition:
Barcode Length:
Code39 – 4 characters
EAN/UPC – 13 characters
Bar & Space Ratio:
1 to 2.5
Ambient Light:
> 500 lux
Minimum & Maximum Scan Distance
Symbology
Resolution
Distance
No. of Encoded Characters
Standard
Code 39
(w/o checksum)
4 Mil
36 ~ 70 mm
4 char.
5 Mil
30 ~ 95 mm
10 Mil
21 ~ 201 mm
15 Mil
35 ~ 285 mm
EAN 13
13 Mil
34 ~ 239 mm
13 char.
Maximum Scan Width
Symbology
Resolution
Barcode Length
No. of Encoded Characters
Standard
Code 39
(w/o checksum)
13 mil
140 mm
27 char.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
13
2-
2-66-2
-2.. Guaranteed
Guaranteed SScanning
canning RRange
ange
Test Condition:
Barcode Length:
Code39 – 4 characters
EAN/UPC – 13 characters
Bar & Space Ratio:
1 to 2.5
Ambient Light:
> 500 lux
Minimum & Maximum Scan Distance
Symbology
Resolution
Distance
No. of Encoded Characters
Standard
Code 39
(w/o checksum)
4 Mil
45 ~ 70 mm
4 char.
5 Mil
35 ~ 95 mm
10 Mil
35 ~ 195 mm
15 Mil
45 ~ 275 mm
EAN 13
13 Mil
40 ~ 230 mm
13 char.
Maximum Scan Width
Symbology
Resolution
Barcode Length
No. of Encoded Characters
Standard
Code 39
(w/o checksum)
13 mil
140 mm
27 char.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
14
22--7.
7. PPitch
itch AAngle,
ngle, Roll
Roll AAngle
ngle and
and Skew
Skew AAngle
ngle
Be aware of the tolerance for the pitch, roll and skew angle of bar code you are
trying to scan.
Pitch Angle: ± 30°
Roll Angle: ± 20°
Skew Angle: ± 40°
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
15
22--8.
8. Specular
Specular Dead
Dead Zone
Zone
Do not place the MT10 directly over the barcode. The light reflecting directly
back into the MT10 from the barcode is known as specular reflection, which can make
decoding difficult. The specular dead zone of MT10 is up to 5° depending on target
distance and substrate glossiness.
Specular Dead Zone: ± 5°
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
16
22--9.
9. Curvature
Curvature Degree
Degree
The curvature degree of a scanned barcode is specified as below:
22--10.
10. Flex
Flex CCable
able Specification
Specification
Below is the drawing of the flat cable(P/N: 6351-0501113) that comes with MT10.
Barcode
Code 39 (L=32 mm)
Code 39 (L=43 mm)
Resolution
13 mil (0.33 mm)
20 mil (0.51 mm)
R
R ≧ 15 mm
R ≧ 20 mm
d
40 mm
PCS
0.9 (printed on photographic paper)
Bottom View
Top View
Top View
Bottom View
(Stiffener)
(Contact)
(Contact)
(Stiffener)
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
17
22--11.
11. Connector
Connector Specification
Specification
12-pin Molex® FPC Connector (Molex P/N: 54548-1229), to be installed on Host
side.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
18
33.. INSTALLATION
INSTALLATION
The MT10 scan engine is designed specifically for integration into customer's housing
for OEM applications. However, the MT10’s performance will be adversely affected or
permanently damaged when mounted into an unsuitable enclosure.
Warning: The limited warranty is void if the following recommendations are not
adhered to when mounting the MT10.
3-1.
3-1. Electrostatic
Electrostatic Di
Discharge
scharge Cautions
Cautions
All MT10s are shipped in ESD protective packaging due to the sensitive nature of
the exposed electrical components.
1.
ALWAYS use grounding wrist straps and a grounded work area when
unpacking and handling the MT10.
2.
Mount the MT10 in a housing that is designed for ESD protection and stray
electric fields.
3-2.
3-2. Mechanical
Mechanical Dimension
Dimension
When securing the MT10 by utilizing the self-forming screws:
1.
Leave sufficient space to accommodate the maximum size of the MT10.
2.
Do not exceed 1kg-cm (0.86 lb-in) of torque when securing the MT10 to the
host.
3.
Use safe ESD practices when handling and mounting the MT10.
Front View
Side View
Top View
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
19
3-3
3-3.. Window
Window Material
Materialss
Following are descriptions of three popular window materials:
1.
Poly-methyl Methacrylic (PMMA)
2.
Allyl Diglycol Carbonate (ADC)
3.
Chemically tempered float glass
Cell Cast Acrylic (ASTM: PMMA)
Cell cast Acrylic, or Poly-methyl Methacrylic is fabricated by casting acrylic
between two precision sheet of glass. This material has very good optical quality,
but is relatively soft and susceptible to attack by chemicals, mechanical stress
and UV light. It is strongly recommended to have acrylic hard-coated with
Polysiloxane to provide abrasion resistance and protection from environmental
factors. Acrylic can be laser-cut into odd shapes and ultrasonically welded.
Cell Cast ADC, Allyl Diglycol Carbonate (ASTM: ADC)
Also known as CR-39TM, ADC, a thermal setting plastic widely used for plastic
eyeglasses, has excellent chemical and environmental resistance. It also has an
inherently moderate surface hardness and therefore does not require
hard-coating. This material cannot be ultrasonically welded.
Chemically Tempered Float Glass
Glass is a hard material which provides excellent scratch and abrasion
resistance. However, un-annealed glass is brittle. Increased flexibility strength
with minimal optical distortion requires chemical tempering. Glass cannot be
ultrasonically welded and is difficult to cut into odd shapes.
Property
Description
Spectral Transmission
85% minimum from 635 to 690 nanometers
Thickness
< 1 mm
Coating
Both sides to be anti-reflection coated to provide 1%
maximum reflectivity from 635 to 690 nanometers at
nominal window tilt angle. An anti-reflection coating can
reduce the light that is reflected back to the host case.
Coatings will comply with the hardness adherence
requirements of MIL-M-13508.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
20
3-4.
3-4. Window
Window Specifications
Specifications
Window Specifications for MT10 Integration
Distance
Tilt Angle (a)
Minimum Window Size
Horizontal (h)
Vertical (v)
Thickness (t)
< 0.5mm (b)
0
0
18 mm
5.5 mm
< 1 mm
10 mm (c)
> +20° < -20°
32 mm
6 mm
20 mm (c)
> +17° < -17°
48 mm
6.5 mm
30 mm (c)
> +15° < -15°
64 mm
7 mm
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
21
The window size must increase as it is moved away from MT10 and should be
sized to accommodate the field of view and illumination envelopes shown
below:
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
22
3-5.
3-5. Window
Window Care
Care
In the aspect of window, the performance of MT10 will be reduced due to any
kind of scratch. Thus, reducing the damage of window, there are few things
have to be noticed.
1. Avoid touching the window as much as possible.
2. When cleaning the window surface, please use non-abrasive cleaning cloth,
and then gently wipe the host window with the cloth that is already sprayed
with glass cleaner.
4.
4. REGULATIONS
REGULATIONS
The MT10 scan engine conforms to the following regulations:
1.
Electromagnetic Compliance – CE EN55022, EN55024
2.
Electromagnetic Interference – FCC Part15 Subpart B (Class B)
3.
Photobiological Safety – IEC 62471 (Exempt Group)
4.
Environmental Regulations – RoHS 2.0, WEEE
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
23
5.
5. DEVELOPMENT
DEVELOPMENT KIT
KIT
MARSON MB100 Demo Kit (P/N: 11A0-9801A20) enables the development of products
and systems using the MT10 on the MS Windows OS platform. Besides the Multi I/O
board (P/N: 2006-1007X00), the MB100 Demo Kit provides the software and hardware
tools required for testing the MT10 applications before integrating it into the host
device. Please contact your sales representative for ordering information.
MB100 Multi I/O Board (P/N: 2006-1007X00)
MB100 Demo Kit Accessories
O: Supported
X : Not Supported
Interface
Cable
RS232
USB HID
USB VCP
External Y-cable
o
o
o
(P/N: 7090-1583A00)
Internal Y-cable
o
o
o
(P/N: 5300-1315X00)
Micro USB Cable
x
o
o
(P/N: 7005-9892A50)
Due to the advantage of its small size, MB100 Multi I/O board is also suitable for being
installed inside the host system, as an interface board connecting MT10 to the host
device.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
24
6.
6. SLEEP
SLEEP ((IDLE
IDLE)) MODE
MODE
The Sleep (Idle) Mode is disabled by default. To enable Sleep (Idle) Mode, simply
follow below instruction to configure the “Pre-Idle Time”, or the period of inactivity
before MT10 enters Sleep (Idle) Mode, as appropriate.
A. Standard Mode
Firmware version: SM3-d-x.xx (MT10 P/N: 110P-A000000)
Steps:
1. Scan SET MINUTE [.B030$] or SET SECOND [.B029$]
2. Scan two digit from the numeric barcode table below.
3. Scan SET MINUTE [.B030$] or SET SECOND [.B029$]
Notes:
Pre-Idle Time - Min: 10 sec, Max: 60 min & 60 sec
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
25
B. Command Mode
Firmware version: SM3-d-x.xx.CMD (MT10 P/N: 110P-4000000)
Property
Option
Remark
Sleep (Idle) Mode
{MC11WT1}
0 Off
1 On
Default : Off
When enabled, scanner will automatically enter
Sleep Mode after a period of inactivity(Sleep Mode
timeout).
Pre-Idle Time
{MC11WT,1,0}
A number from
0~60 (Minute)
A number from
0~60 (Second)
Default : 1 minute
Sleep Mode timeout(10 sec ~ 60 min & 60 sec), the
period of inactivity before the scanner enters Sleep
Mode.
Steps:
1.
Send {MC11WT1} & {MC11WT,1,0} to the MT10 if you want to enable Sleep (Idle)
Mode and set Pre-Idle Time as 1 minute.
2.
The MT10 will return {MC11,OK} and {MC11,1,1,0} respectively as confirmation.
3.
If you want above settings to be saved permanently in Flash ROM, send
{MCMDWT1} to the MT10. Otherwise MT10 will be reset to default after wake up
from sleep.
Notes:
Curly braces “{ }” must be included at both ends of each command.
7.
7. PARAMETER
PARAMETER SETUP
SETUP
You can set up your MT10 using one of the following methods:
1.
Standard Mode (F/W ver.: SM3-d-x.xx):
Scan configuration barcodes from the Universal User’s Manual, or use Ez Utility®,
both of which are available for download at www.marson.com.tw
2.
Command Mode (F/W ver.: SM3-d-x.xx.CMD):
Send software commands from the host, or use BEO®, which is available for
download at www.marson.com.tw. Full list of software commands can be found in
the Help File of BEO program, on the chapter Test Window/ Command Operation.
MT10 Linear Image Scan Engine, Integration Guide, V1.9
___________________________________________________________________________________
26
8.
8. VERSION
VERSION HISTORY
HISTORY
Rev.
Date
Description
Issued
Checked
1.0
2016.05.09 Preliminary Draft Release
Shaw
Jou
1.1
2016.05.11
Revised D.O.F
Shaw
Jou
1.2
2016.07.06
Revised Electric & Flex
Cable Specification
Shaw
Jou
1.3
2016.10.31
Revised Sleep Mode
command in Chapter 6
Shaw
Jou
1.4
2017.06.21
Deleted Red Cell-Cast
Acrylic Description
Shaw
Hus
1.5
2018.03.06 Revised P/N on page10&24
Shaw
Jou
1.6
2018.03.15
Updated Chapter 1 and 1-1
on MCU.
Updated Chapter 6 on
Command Mode settings.
Shaw
Jou & Hus
1.7
2018.06.19
Updated Working
Temperature.
Shaw
Jou
1.8
2018.07.23
Added Typical D.O.F &
Guaranteed D.O.F
Shaw
Hus
1.9
2018.09.03 Updated Chapter 3-4
Shaw
Hus
Marson Technology Co., Ltd.
9F., 108-3, Mincyuan Rd., Sindian Dist., New Taipei City, Taiwan
TEL: 886-2-2218-1633
FAX: 886-2-2218-6638
E-mail: [email protected]