marsden MBF-6010 Manual 

Specifications

Brand: marsden
Category: Scales
Model: MBF-6010 (Manual )
File Type: PDF
File Size: —
Pages: 29

Read Online

Read the marsden MBF-6010 Manual  online using the built-in PDF viewer.

Text of the manual

Medical Body Fat Scale

Please keep the instruction manual at hand all the time for future reference. all-guides com

TABLE OF CONTENTS

TABLE OF CONTENTS ........................................................................... 2 PREFACE ................................................................................................... 3 GENERAL INFORMATION.................................................................... 3 NOTES ON SAFETY................................................................................. 3 ENVIROMENTAL..................................................................................... 3 MAINTENANCE ....................................................................................... 4 WARRANTY-LIABILITY ........................................................................ 4 DISPOSING OF THE SCALE.................................................................. 4 SPECIFICATION ...................................................................................... 7 SPECIFICATION ...................................................................................... 8 PRODUCT STRUCTURE ........................................................................ 9 PRODUCT STRUCTURE ...................................................................... 10 PANEL AND KEY FUNCTION...............................................................11 PANEL AND KEY FUNCTION.............................................................. 12 DISPLAY................................................................................................... 13 BEFORE OPERATION........................................................................... 14 SETTING TIME AND DATE................................................................... 15 OPERATION INSTUCTION Body Composition Analysis ..................... 16 OPERATION INSTUCTION Body Composition Analysis ..................... 17 SET UP YOUR DEVICE......................................................................... 19 RS-232 INTERFACE INSTRUCTIONS................................................ 20 FORMAT OF THE PRINT OUT............................................................ 21 ASSEMBLY INSTRUCTION ................................................................. 22 INSTRUCTION FOR REPLACING BATTERIES.............................. 24 MBF-6010 ASSEMBLY ........................................................................... 25 ERROR MESSAGE................................................................................. 26

Thank you for choosing our product. All features of this product were designed to state of the art and are

optimized for simple and straightforward use. If you have any query or experience any problem not addressed in the operating instructions, please contact our sales / service people. GENERAL INFORMATION We strongly recommend you use this device on flat and hard surface. Any soft surface, like carpet will cause inaccuracy. NOTES ON SAFETY Danger: Never use this unit in combination with medical electronic devices such as: � Medical electronic implants such as pacemakers. � Electronic life support systems such as an artificial heart/lung. � Portable electronic medical devices such as an electrocardiograph. This unit may cause the above mentioned medical electronic devices to malfunction. Caution: Before putting the device into use, please read with care the information given in the Operating Instructions. They contain important instructions for installation, proper use and maintenance of the device. The manufacturer shall not be liable for damages arising out of failure to heed the following instructions: � When using electrical components under increased safety requirements, always comply with the appropriate regulations. � Improper installation will render the warranty null and void. � Ensure the voltage marked on the power supply unit matches your main power supply. � This device is designed for use indoors. � Observe the permissible ambient temperatures for use � The device meets the requirements for electromagnetic compatibility. Do not exceed the maximum values specified in the applicable standards. If you have any problem, please contact our sales / service people. ENVIROMENTAL � All batteries contain toxic compounds; disposal of batteries should be delegated to a competent organization, complying with the deposit of Poisonous Waste Regulation 1972.

� Please do not incinerate batteries.

� The optimum operating temperature for the scale is 5℃ to +35℃; although it will operate at higher and lower temperatures the scales battery life will adversely be effected. MAINTENANCE � The scale does not require any routine maintenance. However, we recommend checking the scale’s accuracy at regular intervals. The regularity of these checks is dependent on the level of use and the state of the scale. If any inaccuracies occur, please contact our sales / service people. � WEIGHING OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please read the following important guidelines: � Always be sure that the display shows `0.0` before use, if it does not then please press the ZERO key. � The device is designed to detect when a stable weight is achieved, the indicator will `bleep` twice to indicate a stable weight value, your reading should be taken at this point. WARRANTY-LIABILITY � If a fault or defect is present on receipt of the unit which is within our scope of responsibility, we shall have the right to either repair the fault or supply a replacement unit. Replaced parts shall be the property of CHARDER. Should the fault repairs or replacement delivery not be successful, the statutory provisions shall be valid. The period of warranty shall be two years, beginning on the date of purchase. Please retain your receipt as proof of purchase. Should your scale require servicing, please contact. � No responsibility shall be accepted for damage caused through any of the following reasons: Unsuitable or improper storage or use, incorrect installation or commissioning by the owner or third parties, natural wear, changes or modifications, incorrect or negligent handling, overuse, chemical, electrochemical or electrical interference or humidity, unless this is attributable to negligence on the part of manufacturer. � If operating, climatic or any other influences lead to a major change in conditions or material quality, the treaty for perfect unit functioning shall be rendered null and void. If we provide and individual warranty, this means that the unit supplied will be free of faults for the length of the warranty period. DISPOSING OF THE SCALE � This product is not to be treated as regular household waste, but should be handed into an electrical/electronic equipment recycling centre. � You can obtain further details from your local council, your municipal waste Disposal Company or

the firm which you purchased the product.

WARNING � Individuals with a Pacemaker or Other Internal Medical Devices This equipment sends a weak electrical current through the body during measurement. Individuals who have internally implanted medical devices, such as Pacemakers, should not use this equipment due to the risk of malfunction to the device that may be caused by the weak electrical current. � Inserting and Removing the Power Cord To reduce the risk of electric shock or product damage, never insert or remove the power cord with wet hands. � Do not under any circumstances dismantle or alter the device, as this could result in electric shock or injury as well as adversely affect the precision of measurements. � To prevent fire hazard � Use only a correctly wired (100-240VAC) outlet, and do not use a multiple outlet extension cable. � Measurements for physically disabled persons. Physically disabled persons should not attempt to take measurements alone, but instead should have their caretakers assist them in using the device. � Keep the unit out of the reach of young children. CAUTION � Cross Contamination The Body Composition Analyzer should be used with bare feet. Please be sure to clean the scale platform with appropriate disinfectant after each use. Never pour any liquid directly on the scale platform, as it may leak and cause internal damage. Use a soft cloth and appropriate ethyl alcohol to wipe off platform. Do not wipe the platform with strong chemicals. � Clean We would recommend using alcohol based wipes or similar when cleaning the scales. Please do not use large amounts of water when cleaning the scales as this will cause damage to the scales electronics, you should also refrain from using corrosive liquids or high pressure washers.

Always disconnect the scales from the mains power supply before cleaning.

� Interpretation of Results The data provided by this machine, as well as any supplementary information such as diet or exercise programs based on this data, should be interpreted by a licensed professional. � Please make sure you place the Weighing Platform on a level and stable surface. If the equipment is used when the Weighing Platform is unstable because not all feet are on the surface, there may be a risk of stumbling or inaccurate measurement. Never jump on the Weighing Platform, there may be a risk of stumbling and malfunction of the equipment. � For the MBF-6000; ensure you use the original AC adapter. Using an AC adapter other than the original one may cause malfunction. Do not insert or remove the plug by the cable. Maintenance Since this equipment is accurately manufactured and adjusted, please observe the following instructions. � Never disassemble the equipment as this may cause malfunction. Users must not disassemble or adjust this equipment. � Unplug the unit from the wall outlet when it will not be in use for long periods of time. � Keep the electrodes clean by wiping them with disinfectant. � Do not drop the unit, and avoid locations with constant vibration. � Do not put this equipment in direct sunlight, close to heaters or near direct draughts from air conditioners. all-guides com

300kg x 0.1kg

Weight Unit kg (approval) LCD Display 0.8 inch LCD display (Three row LCD) Key Functions ON/OFF, ZERO, PRE-TARE, BODY TYPE 0~9,CLEAR, ENTER, TIME ,PRINT Weight Measurement Accuracy ±0.15kg Measurement System 4 polar Bioelectrical Impedance Analysis Measurement Current 50kHz 500uA Measurement Style Right leg, Left leg Impedance Measurement Measurement Range 200 ~ 1000Ω / 0.1Ω Gender Male / Female Body Type Standard / Athletic Age 10 ~80 years old Input Items Height 60 ~ 210cm / 2ft ~ 7ft 11.0in

EX: 30/10/2008 10:55

Body Type Standard / Athletic Gender Male / Female Age 10 ~ 80 years old / 1 year increments Height 60 ~ 210cm / 2ft ~ 7ft 11.0in Weight 0 ~ 300kg BMI 0.1 increments BMR 1 kcal increments FAT% 5 ~ 50% / 0.1% increments Fat Mass 0.1kg increments FFM 0.1kg increments Output Items (Display and Print out) TBW 0.1kg increments Platform Dimension 450(L) X 340(W) X 88(H) mm Power Supply 7.2V 2000mA rechargeable battery or AA (1.5X6) 9V batteries. Medical Switch AC adapter 12V 2A Operation Temperature & Humidity 5 ~35 3 ℃ ℃ 5% / 90% RH Storage Temperature & Humidity -20℃~60℃ 25% / 95 % RH (without condensation) OPTION THERMAL PRINT/Height meter RS232 9D CONNECT (FEMAL) FOR PC

A: Remote indicator

B: Digital LCD C: Control Panel D: Posterior Electrodes E: Platform F: Adjustable feet G: Battery Type D A B C E F G

B: Digital LCD

C: Control Panel D: Posterior Electrodes E: Platform F: Adjustable feet G: Battery Type E D A B C F G

PANEL AND KEY FUNCTION

Key Function 1. ON/OFF: Power on or power off. 2. ZERO: Zero the system. 3. PRE-TARE: Deduct the weight of clothing before measuring . TIME: Setting time and date. 4. CLEAR: Press this key to return normal mode. 5. PRINT: When printer or PC is connected to the scale, press this key to print patient’s weight, height, body type, age, FAT, BMI, FAT MASS, BMR, TBW, and FFM all-guides com

PANEL AND KEY FUNCTION

6. ENTER: In setting function mode, this key means,” enter”. In normal mode, this key means “down”. 7. 0-9: Press numeral keys while setting the height and weight. 8. BODY TYPE: � : Standard - Male. � : Standard - Female. � : Athletic. Note. To select the appropriate body type We defines “Athletic” as a person involved in intense physical activity of at least 12 hours per week and who has a resting heart rate of approximately 60 beats per minute or less. Our athletic definition does not include “enthusiastic beginners” who are making a real commitment to exercising at least 12 hours per week but whose bodies have not yet changed to require the Athletic mode.

1. Install Rechargeable battery pack in the battery box of indicator or

plug the connector of AC ADAPTER (12V 2A) in the indicator. 2. Assemble the cable to the printer, then connecting its 9D connector to the indicator. 3. Make sure the paper is installed in the printer.

SETTING TIME AND DATE

1. Press ON/OFF key, switch on the scale. 2. Press TIME key, entering the DATE / TIME SETTING MENU. “Year” of last record will be displayed at the top LCD; the 1st digit will be flash. 3. Change the flash digits by pressing the numerical key of control panel. 4. Press TIME key, entering DATE menu. 5. Change the flash digits by pressing the numerical key of control panel. 6. Press TIME key, entering TIME menu. 7. Change the flash digits by pressing the numerical key of control panel. Format of display: -- YEAR: YYYY -- DATE: MM.DD -- TIME: HR: MIN. 8. Press TIME key to save the setting. LCD displays the updated data by the sequence of YEAR, DATE, and TIME. Return to the weighing mode.

OPERATION INSTUCTION Body Composition Analysis

1. Press ON/OFF key. “0.0” will appear on the top LCD. 2. Connecting the TP-2100 Printer to the scale by the cable supplied in the packaging of printer. Turn on the printer by pressing the I/O switch button which is built at the rear of printer. 3. Press PRE-TARE key. Input the weight of your clothes. A minus weight will be display at the top LCD. 4. Select the body type by pressing one of the buttons. 5. Press ENTER key, entering setting mode of personal data. A height number will be displayed and flash at the 1st digits. Input your height by pressing the numerical key of control panel, or automatically transferred from the HM-201D height measurement. 6. Press ENTER key, an age number displayed and flash at the 1st digits. Input your age. all-guides com

OPERATION INSTUCTION Body Composition Analysis

7. Press ENTER key, a flashing arrow appears next to STEP ON. 8. Step on the four electrodes of platform with bare feet. Stand in a stable position without bending your knees. 9. Weight will be displayed on the top LCD, then will appear and digits running one by one at the bottom for few seconds. 10. BMI and fat% displayed. 11. Press “Print” button of printer, the measurement result will be print out (refer to page 15 for the sample). Tear it from the printer. Heel Toe

P.S.: The following data will be printed on the paper of printer:

BMI, FAT%, FAT MASS, FFM, BMR, TBW, AND IMPEDANCE. 12. Press the ENTER key to switch the monitor of bottom LCD between Height, age and BMI, fat%. 13. Press CLEAR key, return to the weighing mode.

SET UP YOUR DEVICE

When the scale is switched on, hold the [ZERO] key pressed for about 3 seconds until the display shows successively the „SETUP” and „A.OFF” symbols. Selection is carried out with the [TARE] and [HOLD] keys. AUTO-OFF TIME SETUP This enables operator to setup period to shut off device with no operation automatically. When the „End” is selected, the setting can be finished with the [HOLD] key.

RS-232 INTERFACE INSTRUCTIONS

SPECIFICATIONS Communication Standard EIA RS-232 Compatible Communication Method Asynchronous Transmission Signal speed 9600 Data length 8 bits Parity Check None Stop bit 1 bit Handshake None Data Code ASCII SIGNAL LINES AND CONNECTION METHODS Terminal number Signal name 2 TX 3 RX 5 GND Use an RS-232 cross cable when connecting to a personal computer or printer (TP-2100). RS232 Connector

FORMAT OF THE PRINT OUT

MBF-6000 31/03/2009 14:55 BODY TYPE STANDARD GENDER MALE AGE 40 HEIGHT 170.2 cm PRE-TARE 0.0 kg NET WEIGHT 70.0 kg BMI 24.7 FAT% 21.0 % FAT MASS 14.7 kg FFM 55.3 kg BMR 1660 kcal TBW 40.6 kg IMPEDANCE 402.2ohm all-guides com

To install the HM-201D with the MBF-6000

The connection point between the MBF-6000 indicator and HM-201D is illustrated below: Digital Height Measure data cable socket on MBF-6000 Indicator: Insert the HM201D data cable into the socket of MBF-6000 Indicator before use.

Body impedance measurement methods

In the conventional 4-electrode method, current is supplied from the electrodes at the tips of the toes on both feet, with the voltage measured on the heel. This current flows from one lower limb through the lower abdomen and then into the other lower limb, and the bio electrical impedance (hereinafter, impedance,) thus measured is the impedance between the two feet. For reference, the impedance measurement methods for the legs are shown in the diagram below.

INSTRUCTION FOR REPLACING BATTERIES

1. Open the battery housing cover, and take out the battery housing. Reset the rechargeable battery. Make sure the rechargeable battery is properly placed. 2. Place the battery housing back and make sure that the housing pin is connecting to the right point 3. Place the housing back, and close the battery housing cover.

Contact of Sales and after service:

FREEPHONE: 0800 169 2775 HEAD OFFICE: SALES, SERVICE, MARKETING AND ACCOUNTS Anvil House Tuns Lane Henley On Thames Oxon RG9 1SA Telephone: 0845 130 7330 Fax: 0845 130 7440 NORTHERN OFFICE: DESPATCH, PRODUCTION AND TECHNICAL SUPPORT Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Telephone: 01709 364296 Fax: 01709 364293

Manufacturer’s Declaration of Conformity

This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives: 93/42/EEC as amended by 2007/47/EC Medical Device Directive 2009/23/EC Non-automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking. Authorized EU Representative: Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.) IN-1193 【11069A】 01/2011