Kintech Engineering Geovane Quick Start Manual

Specifications

Brand: Kintech Engineering
Category: Measuring Instruments
Model: Geovane (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Kintech Engineering Geovane Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Wind direction measurements reinvented

Avda. Anselmo Clavé nº 37-45 - 50004, Zaragoza - Spain Tel. (+34) 976 221 789 [email protected] www.geovane360.com / www.kintech-engineering.com SENSOR PIN DESCRIPTION DATA LOGGER INPUT CHANNEL 1 Out (V1+) Analog Inputs 1 2 RS-485 A 3 Supply (+) BAT (+) 4 RS-485 B 5 Out (V2+) Analog Inputs 2 6 Out (Hz) Anemometer Inputs 1 7 Supply (-) BAT (-) 8 Out (-) Analog Inputs (-) - Shield BAT GND BAT GSM GPS OUT DIGITAL INPUT 1 ANEMOMETER INPUTS DIR 1 DIR 2 EXTRA ANALOG INPUTS DIGITAL INPUT 2 ANALOG INPUTS 1 2 3 4 5V 5V 5 6 7 8 9 10 3 2 1 3 2 1 6 5 8 7 4 5V 1 2 3 SIG SIG 4 5 2�5 � 1 2 3 4 5 6 7 8 3 2 1 6 5 8 7 4 OUT DIGITAL INPUT 1 DIR 1 DIR 2 EXTRA ANALOG INPUTS DIGITAL INPUT 2 ANALOG INPUTS 3 2 1 3 2 1 6 5 8 7 4 1 2 3 SIG SIG 4 5 2�5 � 1 2 3 4 5 6 7 8 3 2 1 6 5 8 7 4 INSTRUCTIONS Use the following input channels on the logger to connect this sensor. See highligted input channels marked here below. The wire colors used in the connection diagram below only applies in case the cable is supplied by Kintech Engineering. Depending on the number of pins to be used, the number of necessary wires can range from three (frequency output) to eight. See section 3.2 of the manual for detailed pinout and section 8 of the manual for how to configure. BAT OUT DIGITAL INPUT 1 ANEMOMETER INPUTS DIR 1 DIR 2 EXTRA ANALOG INPUTS DIGITAL INPUT 2 ANALOG INPUTS 1 2 3 4 5V 5V 5 6 7 8 9 10 3 2 1 3 2 1 6 5 8 7 4 5V 1 2 3 SIG SIG 4 5 2�5 � 1 2 3 4 5 6 7 8 3 2 1 6 5 8 7 4 OUT DIGITAL INPUT 1 ANEMOMETER INPUTS DIR 1 DIR 2 DIGITAL INPUT 2 1 2 3 4 5V 5V 5 6 7 8 9 10 3 2 1 3 2 1 6 5 8 7 4 5V SIG SIG 3 2 1 6 5 8 7 4

HOW TO CONFIGURE THIS SENSOR IN EOL MANAGER

Keep in mind that the configuration of a Geovane in EOL Manager has to be done according to its outputs configuration. Open EOL Manager and go to the data logger you are working on. Open the “inputs” tab and select the following type and model: Section: Anemometers/Frequency Type: Geovane Model: True North Offset Last modified: 12.03.2018 IMPORTANT After configuring the sensor in EOL Manager make sure to upload the configuration file to your EOL Zenith data logger. See the “Quick User Guide” how to upload confi- guration files to the data logger. All sensor wire shields must be connected to the data logger GND terminal. The data logger should always be connected to a se- parated ground rod. Not to the lightning rod of the tower. For a precise measurement of the True North Offset, the wind wane coupled to the Geovane must have, at all times, its internal angular reference perfectly aligned with the Geovane’s angular reference. See section 4 of the manual. It is recommended to always keep the RS-485 cores (pins 2 and 4) accessible from the ground so the Geova- ne can be re-configured and updated without having to dismount it. STANDARD CALIBRATION SENSOR SELECTION DATASHEET DOWNLOAD MODEL SELECTION Metallic measurement mast, grounded Drawing of anemometer incl. isolator The shield should be connected to both the Geovane side and the data logger side Data logger should always be connected to ground Metallic measurement mast, grounded Drawing of anemometer without isolator The shield should only be connected on the data logger side Not on the Geovane Data logger should always be connected to ground Section: Analog Inputs Type: Geovane Model: True North Offset STANDARD CALIBRATION SENSOR SELECTION DATASHEET DOWNLOAD MODEL SELECTION GEOVANE | WIND DIRECTION MEASUREMENTS REINVENTED [email protected] www.kintech-engineering.com

Other Measuring Instruments Manuals