Mobeye ThermoGuard TwinLog CML2255 Operation & User’s Manual
File Specifications
| Brand: | Mobeye |
| Category: | Measuring Instruments |
| Model: | ThermoGuard TwinLog CML2255 (Operation & User’s Manual), preE/zTdvXLyc |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 40 pages |
Download PDF
Download Mobeye ThermoGuard TwinLog CML2255 Manual (40 pages)Read Online:
Read the Mobeye ThermoGuard TwinLog CML2255 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
4.3 ENTER THE PROGRAM MODE
To activate the unit in the portal, the GSM module needs to be open and connected to the network. In the situation that the CML2255 is connected to an external power supply, the unit is always in program mode. A battery-operated Mobeye CML2255 switches to the program mode after pressing the on/off button for 5 seconds until the LED starts flashing. Alternatively the batteries are re-inserted. While searching for the GSM network connection the outside LED flashes green and red, followed by blinking fast shortly. This process normally takes 10-30 seconds. As soon as ...
5. POSSIBLE SETTINGS
The Mobeye CML2255 has many setting options that influence the behaviour of the module. If connected on the Mobeye Internet Portal, the settings are prepared in the portal (see chapter 4). If your own SIM card is used, programming is done via SMS commands (see chapter 8). 5.1 ALARM PHONE NUMBERS In the event of an alarm, the Mobeye CML2255 can call 5 telephone numbers (TEL1… TEL5). It is possible to confirm a call by picking up the telephone and pressing any key. The following numbers will not be called. When using your own SIM card, it is mandatory to set at least on ...
1. General description
5 2. Standard behaviour 6 2.1 Mobeye CML2255 with Mobeye SIM and Internet Portal 6 2.2 Mobeye CML2255 with own SIM card 7 3. Getting started 9 3.1 Insert the SIM card 9 3.2 Insert the batteries 10 3.3 Connect the temperature sensor 10 3.4 Connect an external power supply (optionally) 10 3.5 Connect a sensor to the inputs (optionally) 11 3.6 Connect a device to the output (optionally) 11 4. Programming when using the Mobeye SIM and portal 13 4.1 Sign up in the Mobeye Internet Portal 13 4.2 Register the Mobeye SIM card 13 4.3 Enter the program mode 14 4.4 Activat ...
The device settings can be changed via the Mobeye Internet Portal. To do this, click
on the "edit" icon and type in the security code (factory setting is "1111"). See chapter 5 for the description per setting. After saving the new settings, they must be retrieved by the device (synchronized). See 4.5 for more information about synchronizing. The device data contain the name and location of the device and can be changed here. These texts are mentioned in every text message and e-mail message to indicate the device. A free text is available as an internal comment field. This i ...
- When the batteries need to be replaced, the Mobeye CML2255 sends a ‘low
battery’ message to the Mobeye Internet Portal. The portal forwards this to the ‘service’ contacts. - The unit will send test messages to the portal as communication check (default: every 7 days). If these are not received in time, the portal sends an exception message to the ‘service’ contacts. Chapter 5 describes how to influence the standard behaviour. As described, the Mobeye CML2255 will, in addition to calling in the event of an alarm, send various messages to the Mobeye Internet Portal. This is done ...
1. GENERAL DESCRIPTION
The Mobeye CML2255 is a GSM module used to monitor the temperature and to send alarm messages once the temperature limits are violated, one of the inputs is activated, or -if powered externally – after a power failure. Two temperature probes can be monitored. If connected to the Mobeye Internet Portal, the temperature values are logged and transferred to the web portal. In order to activate the device, a few steps are to be followed. First of all you’ll have to choose a SIM card to place in the device. You can use the Mobeye SIM card or your own SIM card. The Mobey ...
Mobeye ThermoGuard TwinLog CML2255 user guide recommended for: WaterGuard CM2300, argos i200, CM4000, ThermoGuard TwinLog CML4275, MS100EK.
⚠️ Download Safety
The Measuring Instruments Operation & user’s manual (40 pages) is completely safe to download (last scan date: 26/04/2026).
Related PDF Instructions for Mobeye ThermoGuard TwinLog CML2255:
-
Mobeye ThermoGuard CM2200 Security System Operation & user’s manual
ThermoGuard CM220032 -
Mobeye ThermoGuard TwinLog CML2285 Measuring Instruments Operation & user’s manual
ThermoGuard TwinLog CML228540 -
Mobeye PowerGuard CM4100 Measuring Instruments Operation & user’s manual
PowerGuard CM410032 -
Mobeye WaterGuard CM2300 Kitchen Appliances Operation & user’s manual
WaterGuard CM230014 -
Mobeye CM2500 Security System Portal user manual
CM250032 -
Mobeye MS100E GSM/GPRS Modules Installation manual
MS100E24
Measuring Instruments Equipment: Frequently Requested
-
Michell Instruments Pura Measuring Instruments
10.05.2026Advanced user manual for the Michell Instruments Pura Measuring Instruments. The manual highlights system setup, wiring diagrams, troubleshooting tips.Pura, 48 -
Bosch Rexroth VDP 92.1 Measuring Instruments
22.11.2025User operation guide for the Bosch Rexroth VDP 92.1 Measuring Instruments. This reference manual outlines safety precautions, technical specifications, safety features, maintenance.Rexroth VDP 92.1, 52 -
Sealey TA203.V2 Measuring Instruments
06.03.2026Manual for installation and usage of the Sealey TA203.V2 Measuring Instruments. It details troubleshooting tips and setup validation, troubleshooting guides, cleaning instructions, control functions.TA203.V2, 6 -
Anritsu Site Master S332D Measuring Instruments
29.01.2026Usage and setup manual for the Anritsu Site Master S332D Measuring Instruments. The guide provides instructions on interface navigation, firmware installation, service contacts, safety precautions.Site Master S332D, 174 -
ILX Lightwave OMH-6727B Measuring Instruments
26.01.2026Usage and setup manual for the ILX Lightwave OMH-6727B Measuring Instruments. The document offers guidance on energy usage, device reset instructions, detailing setup, device overview.OMH-6727B, 38 -
GE moisture.IQ Measuring Instruments
10.03.2026Usage and setup manual for the GE moisture.IQ Measuring Instruments. The guide explains setup and performance optimization, warranty information, usage examples, technical specifications.moisture.IQ, 182
Have some Questions about Mobeye ThermoGuard TwinLog CML2255 Device?
Get valuable and actionable advices from other Mobeye ThermoGuard TwinLog CML2255 device users. Describe your problem or question, regarding the using of ThermoGuard TwinLog CML2255, in as much detail as possible, and other users will be able to answer you.