Dynacord DCS 412R Quick Start Manual
Read Online
Read the Dynacord DCS 412R Quick Start Manual online using the built-in PDF viewer.
Text of the manual
Dynacord | DCS 412R
DCS 412R
www.dynacord.com
▪ 12 inputs
▪ The polarity for each input can be freely selected
▪ Each input is isolated by separating the wire
jumpers
▪ Pluggable connection terminals for power supply to
the buttons, contacts, and sensors
The module is fitted on the back of the DCS 400 rack
plug-in board. The module is used to connect control
cables, buttons, switches, and sensors in order to
check their status (on, off) in the PROMATRIX 8000
system.
Additional properties:
• Pluggable connection terminals with screwed flange
for all inputs
• A maximum of 5 DCS 412R modules can be cascaded
Parts included
No.
Component
1
DCS 412R
2
Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)
Technical specifications
Operating voltage
24 V DC, -10%/+30%
Operating current, all inputs open
• Standby/Idle/
Announcement/Alert
24 V, 83 mA, 2.00 W
Electromagnetical environment
E1, E2, E3
Operating temperature
-5 °C to 45 °C
Product dimensions (Width by
Height by Depth)
37.5 by 80.6 by 245 mm
Net weight
175 g
Input level
• Input voltage for off (Low)
U_IN < ±5 V
• Input voltage for on (High)
U_IN > ±10 V
• Input current at U_IN = 24 V
I_IN = 4.8 mA
• Input voltage max.
U_IN max = ±31 V
Output source 24 V
• Output current max.
90 mA
CN to Backplane
GND
BR1
BR2
BR3
BR4
BR5
BR6
BR7
BR8
BR9
BR10
BR11
BR12
A13
B28
GND
REF-OUT
+24V
Block diagram
Installation/configuration notes
Installation information
On the DCS 400 rack plug-in board, slots 1–10 must
be occupied in ascending sequence (left to right)
without any gaps. Different module types can
otherwise be arranged in any sequence.
Exception: Slot 1 (far left) must always be occupied
with a DCS 801R control module or DCS 405R
extension module.
When assembling the device and installing the
connections, please comply with the standards VDE
0100 and EN 60065.
Connector
The scope of delivery for the device includes two 15-
pin connectors. Conductor cross-sections of 0.14 mm²
(AWG26) to 1.5 mm² (AWG16) can be used.
Recommended connecting cable: flexible CU strand,
LiY, 0.75 mm².
Position of the bridges on the circuit board
Certifications and approvals
Status as of November 2012:
• EN 50130-4
• EN 54-16
• EN 55103-1
• EN 55103-2
Ordering information
DCS 412R
Order number F.01U.121.788
2 | DCS 412R
Represented by:
Germany:
EVI Audio GmbH
Sachsenring 60
94315 Straubing
Germany
www.dynacord.com
© Bosch Security Systems 2013 | Data subject to change without notice
Document Number | Vs1 | 19. Mar 2013