DSE DSE9462 Installation Instructions

Text of the manual

TYPICAL WIRING DIAGRAM

WARNING!: Ensure the Remote Sensing Wires are connect to the correct battery to prevent damage caused by overcharging. D E E P S E A E L E C T R O N I C S DSE9462 Installation Instructions 053-189 ISSUE 1 DANGER OF DEATH: LIVE PARTS exist within the DSE9462 enclosure. The enclosure cover must not be removed. INSTALLATION The battery charger is designed to be mounted within a control panel, utilising the integral mounting holes. The battery charger is fit-and-forget. It may be permanently connected to the supply and the load, with no requirement to disable the charger during times of heavy load (such as engine cranking) or when in parallel with a charging alternator. BATTERY SUITABILITY The charger is factory set by DSE to suit Lead Acid batteries and may be ordered to suit other battery types. Additionally, configuration is possible using the DSE Configuration Suite PC Software to suit other battery types. Care must be taken to ensure the batteries connected to the charger are of the correct ‘technology’ to suit the setting of the charger. INDICATIONS The DSE9462 Battery Charger features LED indicators to show the battery charger Status. Deep Sea Electronics Plc. Tel:+44 (0)1723 890099 Fax: +44 (0)1723 893303 Email: [email protected] Web: www.deepseaplc.com Deep Sea Electronics Inc. Phone: +1 (815) 316-8706 Fax: +1 (815) 316- 8708 Email: [email protected] Web: www.deepseausa.com

NOTE: This document is intended as a ‘quick start’ guide only. For full

operating instructions and specifications, refer to DSE publication: 057-255 DSE9462 Operator Manual. Description Specification Connection Type Cage clamp terminals Min Cable Size Accepted in Terminal (Battery Connection) 0.08 mm² (AWG 28) Max Cable Size Accepted in Terminal (Battery Connection) 4.0 mm² (AWG 12) Strip Length (Battery Connection) 8 mm to 9 mm (0.31 “ to 0.35 “) Min Cable Size Accepted in Terminal (Other Connections) 0.08 mm² (AWG 28) Max Cable Size Accepted in Terminal (Other Connections) 2.0 mm² (AWG 14) Strip Length (Other Connections) 7 mm to 8 mm (0.28 “ to 0.31 “) Recommended AC Fuse 230 V AC Input 110 V AC Input 10 A anti-surge 10 A anti-surge MAINS SUPPLY CABLE Connection Cable Colour L1 Brown Neutral Blue Earth Green and Yellow STATUS LEDS Each output has its own dedicated LED to show charge status. Status 1: Charge status of Output 1. Status 2: Charge status of Output 2. Condition Status LED Output Not Charging (Due to Fault or Charger Off) Off Battery Detection Mode Green Constant Bulk (Boost) Charge in Progress Yellow Constant Absorption Charge in Progress Yellow Flashing Float Charge in Progress Green Constant Storage Charge in Progress Green Flashing FAULT LEDS Two Fault LEDs, Fault 1 and Fault 2 are used to indicate faults. Output 1 and Output 2 share these indications. Where two alarms are present at the same time, the most critical is displayed. Condition LED Fault 1 Fault 2 DC Over Volts Warning and Trip DC Under Volts Warning Battery Detection Warning DC Over Current Battery Reverse Polarity Short Circuit Protection Battery Detection Warning Red Constant Off Input Fuse Failure AC Under Voltage Warning and Trip AC Over Volts Warning and Trip DC Over Current Warning Cable Voltage Drop Alarm Red Flashing Off Battery Over Temperature Warning and Trip Battery Temperature Sensor (PT1000) Fail Ambient Over Temperature Off Red Constant Battery Charger Failure Red Constant Red Constant Battery Detection Mode - Battery Not Detected Red Flashing Red Flashing DIMENSIONS AND MOUNTING NOTE: The DSE battery charger is designed to be mounted with the base to a vertical surface with the connection terminals at the bottom. Description Dimension Case Dimensions 162 mm x 291 mm x 74 mm (6.4 ” x 11.5 ” x 2.9”) Mounting Holes Dimensions Suitable for M5 (0.2 ” diameter) Mounting Hole Spacing 95 mm x 279 mm (3.7 ” x 11.0 ”) Required Ventilation Spacing 100 mm (3.9 ”) air space around the battery charger.

Other Battery Charger Manuals