Certa CTINV35GENA Operation & User’s Manual
Text of the manual
Please pay attention to the following warnings when you see them in this manual.
WARNING: Indicates a strong possibility of severe personal injury or death if
instructions are not followed.
CAUTION: Indicates a strong possibility of severe personal injury or death if
instructions are not followed. If a problem should arise, or if you have any
questions about the generator, please contact the Kogan customer support team.
CARE: The generator is designed to give safe and dependable service if
operated according to instructions. Read and understand the user manual before
operating the generator. Failure to do so may result in personal injury or
equipment damage.
Safety Instructions
WARNING: Exhaust contains poisonous carbon monoxide. Do not operate the
generator in a confined environment. Only use outdoors, away from open doors,
windows or vents.
WARNING: The muffler becomes extremely hot during operation, and remains
hot for a while after stopping the engine. Be careful not to touch the muffler
while it is hot. Let the engine cool before storing the generator indoors.
WARNING: The engine exhaust system will be heated during operation and will
remain hot immediately after stopping the engine. To prevent scalding, pay
attention to the warning labels on the generator.
CARE: Do not connect other cables to receptacles during use or use a special
jack as it may cause electric shock.
WARNING: Fuel is extremely flammable, and is even explosive under certain
conditions. Refuel unit in a ventilated area with the engine stopped.
WARNING: Keep away from cigarettes, smoke and sparks when refuelling the
generator. Always refuel in a well ventilated location.
WARNING: Connecting the unit to a building electrical system as a standby
power source must be performed by a qualified electrician. The connection must
isolate the generator from utility power, and must comply with all applicable laws
and electrical codes. Improper connections to a building's electrical system can
allow electrical current from the generator to backfeed into the utility lines. Such
backfeed may electrocute utility company workers or others who contact lines
during a power outage, and the generator may explode or catch fire when utility
power is restored.
WARNING: To avoid accidents and equipment damage, check the generator
every time before starting the engine.
WARNING: Keep the generator at least 1 meter away from other equipment
during operation.
WARNING: Keep the generator horizontal when running. If the generator is
tilted, it may cause fuel spillage.
WARNING: Generator operators must be trained, must know how to stop the
generator quickly and understand the purpose and operation of all controllable
parts. Untrained operators must not be allowed to use the equipment.
WARNING: Keep children and pets away from operation area.
WARNING: Keep away from rotating parts during operation.
WARNING: Do not operate unit with wet hands.
WARNING: Do not operate the generator in rain or snow, or let it get wet.
CAUTION: Wipe up any spilled fuel at once.
1
Table of Contents
Warnings......................................................................................................................................................1
Safety Instructions..............................................................................................................................1
Product Layout........................................................................................................................................3
Unit Body...............................................................................................................................................3
Control Panel........................................................................................................................................3
Smart Throttle.....................................................................................................................................3
Safety Label Locations....................................................................................................................3
Pre-operation Checks......................................................................................................................4
Checking the Oil.................................................................................................................................4
Checking the Fuel Level.................................................................................................................4
Check the Air Cleaner......................................................................................................................5
LCD Display Layout..........................................................................................................................6
Attaching the wheels to the generator ..................................................................................7
Using the remote controller & emergency button..............................................................7
Using the Generator..............................................................................................................................8
Starting the Engine...........................................................................................................................8
High Altitude Operation.................................................................................................................9
Generator Use.....................................................................................................................................9
AC Applications................................................................................................................................10
Output and Overload Indicators...............................................................................................10
DC Applications................................................................................................................................12
Starting the Engine..........................................................................................................................13
Oil Alert System................................................................................................................................13
Stopping the Engine.......................................................................................................................14
Maintenance.............................................................................................................................................15
Maintenance Schedule...................................................................................................................15
Changing Oil.......................................................................................................................................15
Air Cleaner service...........................................................................................................................17
Spark Plug Servicing.......................................................................................................................17
Transporting and Storage..................................................................................................................18
Transporting the generator..........................................................................................................19
Before storing the unit for an extended period.................................................................19
Muffler Fire Net Service.................................................................................................................19
Troubleshooting....................................................................................................................................20
Engine will not start.......................................................................................................................20
Deficient AC Output........................................................................................................................21
Equipment connected to generator won't start................................................................21
There is no power in the DC electric outlet..........................................................................21
Specifications.........................................................................................................................................22
Product dimensions........................................................................................................................22
Engine...................................................................................................................................................22
Generator ...........................................................................................................................................22
2
The engine speed is kept at idle automatically when an electrical appliance is
disconnected, and will return again to proper speed when an electrical appliance
is connected. This is designed to minimise fuel consumption during operation.
Safety Label Locations
These labels warn you of potential hazards that can cause serious injury. Read the
labels and safety notes and precautions described in the manual carefully.
3
Air Vent Knob
Fuel
Cap
Top Maintenance
Cover
Control
Panel
Starting Grip
Muffler
Cover
Fuel Valve
Primer Bulb
Maintenance
Access
Overload Indicator
Light
Output Indicator
Light
Oil Alert Indicator Light
Eco Throttle Switch
Engine Switch
DC
Socket
DC Circuit
Breaker
Grounding
Terminal
AC Socket
AC RV
Socket
Avoid Fire
Label
Avoid Burns
Label
Parameter
Label
Ventilation
Label
Primer Bulb
Label
EPA Label
EPA Label
Be sure to check the generator is on a level surface with the engine
stopped.
•
Check the engine oil level.
•
Using 2-stroke engine oil could shorten the engine's service life. Use a
premium quality 4-stroke engine oil.
Checking the Oil
•
Loosen the cover screw and remove the left side maintenance cover.
Remove the oil filer cap, then wipe the dipstick with a rag. Check the oil
level by reinserting the dipstick into the filler hole without screwing it in.
•
If the oil level is below the end of the dipstick, refill up to the top of the oil
filler neck.
Note: The Oil Alert System will automatically stop the engine before the oil level
falls below the safe limit, however to avoid the inconvenience of an unexpected
shut-down, it is still advisable to visually inspect the oil level regularly.
Checking the Fuel Level
•
Turn the fuel cap lever to the “OFF” position before transporting.
•
Use unleaded automotive fuel.
Note: DO NOT use any fuels containing alcohol. Fuel system damage or engine
performance problems resulting from the use of fuels that contain alcohol are not
covered by warranty.
4
Dipstick
Lowest oil
level allowed