Einbau- und Betriebsanleitung
GB
Installation and operating instructions
F
Notice de montage et de mise en service
NL
Inbouw- en bedieningsvoorschriften
E
Instrucciones de instalación y funcionamiento
I
Istruzioni di montaggio, uso e manutenzione
P
Manual de instalação e funcionamento
4 090 996-Ed. 01/2008-07-GRD
Einbau- und Betriebsanleitung
3
GB
Installation and operating instructions
15
F
Notice de montage et de mise en service
26
NL
Inbouw- en bedieningsvoorschriften
38
E
Instrucciones de instalación y funcionamiento
50
I
Istruzioni di montaggio, uso e manutenzione
62
P
Manual de instalação e funcionamento
74
Installation and operating instructions MHIE 1~
14
1 General
1.1 Applications
Pumps for pumping clear liquids in the residential
sector, in agriculture and in industry. Intake from
wells, springs, water streams, ponds ... not to be
used with Abyssinian wells (driven wells).
1.2 Technical data
• Maximum operating pressure:
10 bar
• Minimum intake pressure:
6 bar
• Temperature range:
- Version with seals and inserts made of EPDM*:
-15° to +110°C
- Version with seals and inserts made of VITON*:
-15° to +90°C
• Suction head:
depending on the Net Positive Suction Head
(NPSH) of the pump
• Ambient temperature (standard):
+40°C (in cases of higher temperatures, please
consult Wilo after-sales service)
*Application in potable water sector: WRAS: English standard,
KTW: German standard.
2 Safety
These Installation and operating instructions con-
tain basic information which must be adhered to
during installation and commissioning. For this
reason, these Installation and operating instruc-
tions must, without fail, be read by the service
technician and the responsible operator before
installation and commissioning. It is not only the
general safety instructions which are listed here
under the main heading of Safety which must be
complied with, but rather also the special safety
instructions which are listed under the following
main headings.
2.1 Identification of notes in the Installation and
operating instructions
The safety instructions contained in these
Installation and operating instructions which, if
they are not observed, could endanger personnel,
are specially marked with the General danger
symbol,
and with
in cases of warnings against electrical voltage.
The word
is included with safety instructions which, if they
are not observed, could endanger the installation
and its function.
2.2 Personnel qualifications
The personnel responsible for installation must be
in possession of the respective qualifications
required for this work.
2.3 Danger in the event of nonobservance of the
safety instructions
The failure to observe the safety instructions
could result in dangers to personnel and
pump/installation. Nonobservance of the safety
instructions can result in the loss of any claims to
damages.
In particular, the failure to observe these instruc-
tions could lead to the following hazards:
• Failure of important functions of the pump/instal-
lation.
• Hazards to personnel resulting from electrical,
mechanical or bacteriological actions,
• Property damage.
2.4 Safety instructions for the operator
The existing regulations regarding accident pre-
vention are to be complied with.
Hazards connected with electrical energy are to
be excluded. The regulations of the VDE (Verband
der Elektrotechnik Elektronik und Informations-
technik e.V.) and of the local energy supply com-
panies are to be complied with.
2.5 Safety instructions for inspection and installa-
tion work
It is the responsibility of the operator to ensure
that all inspection and installation work is carried
out by authorised and qualified professionals who
have acquired sufficient information from a
detailed study of the Installation and operating
instructions.
As a fundamental principle, work may only be car-
ried out on the pump/installation when it/they are
at a standstill.
2.6 Customer's own conversions and spare parts
manufacture
Modifications to the pump/installation are not
permitted except after consultation with the
manufacturer. The use of original spare parts and
manufacturer-authorised accessories promotes
safety. The use of other parts could lead to the
cancellation of liability for the results of such
substitutions.
2.7 Improper use
The operating safety of the supplied pump/instal-
lation is only guaranteed for conventional use in
accordance with Section 1 of the Installation and
operating instructions. It is not permitted to
exceed or fail to meet the limit values specified
in the catalogue/data sheet under any circum-
stances.
3 Transport, handling and storage
The pump/installation is to be checked at once
upon delivery for any damage that may have
occurred in transit. If any damages are found, then
they are to be reported to the transport company
immediately within the time periods specified.
If the material is to be installed later,
then it must be stored in a dry location.
The material must be protected against
impact shocks and all external influ-
ences (moisture, frost, etc.).
Handle the pump carefully so that the geometry
and alignment of the installation are not altered.
The pump is not permitted under any
circumstances to be raised on the fre-
quency converter.
ATTENTION!
ATTENTION!
ATTENTION!
WILO SE 05/2008
15
4 Products and accessories
4.1 Description (see Fig. 1-9):
1 : Foot valve with suction strainer (maximum free-
flowing cross-section 1 mm)
2 : Stop valve; on suction side
3 : Stop valve; on the pressure side
4 : Non-return valve
5 : Inlet/bleeder screw
6 : Drainage screw
7 : Pipe bracket
8 : Suction strainer
9 : Replenishment reservoir
10 : Tap water network
11 : Switch, switch amplifier with fuses
12 : Cock
13 : Pedestal
14 : Pressure sensor
15 : Diaphragm pressure vessel
16 : Gate valve for diaphragm pressure vessel
17 : Red LED
18 : Green LED
19 : Potentiometer
20 : Connection terminal
21 : Protection against low water level
HA : Maximum suction head
HC : Minimum suction head
4.2 The pump
Horizontal centrifugal pump.
Multistage, not self-priming.
Suction/outlet openings with thread.
Axial suction, radial outlet upwards.
Sealing on shaft passage by means of standard
mechanical seal.
4.3 The motor with frequency converter
Three-phase AC motor, two-pole, with frequency
converter.
Protection class: IP 54.
Insulation class: F
4.4 Accessories (optional)
• Suction kit
• Shut-off device
• Diaphragm pressure vessel
• Tank
• Non-return valve
• Foot valve with suction strainer
• Compensator
• Protection against low water level
(potable water network)
(see Fig. 5, Pos. 21)
• Pressure sensor control kit (sensor precision:
1%; utilisation between 30% and 100% of the
reading range).
5 Installation
Two types:
• see Fig 1: Suction mode.
• see Fig. 2: Pressure operation from replenish-
ment vessel (Pos. 9) or potable water network
(Pos. 10).
5.1 Installation
Install the pump at a readily accessible location
which is protected against external influences
(excessive rain or sunlight, frost) and which is as
near as possible to the extraction point.
Place the pump on a pedestal (Pos. 13) or directly
on a smooth, level base. Fixation of the pump
with 2 holes for Ø M8 bolts.
Note that the height of the installation
location and the temperature of the
fluid will diminish the suction capacity
of the pump.
Installation should be carried out in
pressure operation when temperatures
exceed 80°C.
5.2 Pipe connections
The installation must be sufficient for
the pressure that the pump generates
at maximum frequency and zero flow
volume.
- Connection with spiral-reinforced flexible hoses
or rigid pipe.
- Seal the pipe connections well with suitable
products. No air is permitted to enter the suc-
tion line; lay the suction line with a continuous
rise (2%) (see Fig. 1).
- In the case of rigid pipes, take care to ensure that
the weight of the lines is not borne by the pump
alone. Utilise supports and/or pipe brackets (see
Figs. 1 + 2, Pos. 7).
Pump
MHIE
type
200
400
800
Suction
1"1/4 -
1"1/2 -
opening
1" - (26-34)
(33-42)
(40-49)
Outlet
1" -
1"1/4 -
opening
1" - (26-34)
(26-34)
(33-42)
Pipe connections
Height
Height loss
Temperature Height loss
meter
0.00 m 0.00 mCL
20°C
0.20 mCL
500 m 0.60 mCL
30°C
0.40 mCL
1000 m 1.15 mCL
40°C
0.70 mCL
50°C
1.20 mCL
60°C
1.90 mCL
70°C
3.10 mCL
80°C
4.70 mCL
90°C
7.10 mCL
100°C
10.30 mCL
110°C
14.70 mCL
120°C
20.50 mCL
ATTENTION!
ATTENTION!
ATTENTION!
Frequency
50 Hz
60 Hz
Voltages
1~230 V (±10%)
1~220 V (±6%)
Operational voltages and frequencies
- The diameter of the suction line is never permit-
ted to be smaller than the suction/pumping open-
ing of the pump.
- Limit the horizontal length of the suction line and
avoid all possible sources of pressure losses
(elbows, valves, neckings, etc.).
Possible damage to the pump!
In order to protect the pump against
fluid hammers, install the non-return
valve on the pressure side.
In the frequency converter, the testing current
circuits are shielded from the performance cir-
cuits with the aid of a simple insulation
(CEI664-1).
The installer must ensure that the external
testing current circuits (e.g.: pressure sensors,
external control of the setpoint…) are shielded
against any possible contact with people. If the
testing current circuits are to be connected to
the electric circuits corresponding to the safe-
ty specifications of the SELV (TBTS), then an
additional insulation must be installed in order
to comply with the SELV (TBTS) classification.
5.3 Electrical connections
The electrical connections and testing must be
carried out by a licensed electrician and in
accordance with locally applicable standard
specifications.
The electrical properties (frequency, voltage,
nominal current) of the motor frequency convert-
er are indicated on the name plate of the motor/
of the pump. A check is to be made as to whether
the motor frequency converter matches the cur-
rent supply network to which it is intended to be
attached.
The frequency converter is equipped with a motor
protection feature. Constant protection of the
motor and of the pump are ensured by a continu-
ous nominal/actual comparison of the current and
stored data.
In the event of excessively great resistance on the
part of the neutral conductor, a corresponding
protection device must be installed upstream
from the motor frequency converter.
As a basic rule, provide switch amplifiers with
fuses (Type GF) for the protection of the network
(see Figs. 1 + 2, Pos. 11).
If a residual-current-operated protection switch
needs to be installed for personnel protection,
then use a selective universal-current-sensitive
residual-current-operated protection switch
with VDE certificate!
Adjust the safety switch in accordance with the
data specified on the name plate of the fre-
quency converter.
Use connecting cables that meet applicable stan-
dards.
Earth the pump/installation in accordance with
regulations.
English
Installation and operating instructions MHIE 1~
16
ATTENTION!
The electrical connection of the frequency con-
verter must correspond to the diagrams contained
in the following table:
The frequency converter could be dam-
aged if connected incorrectly.
The electric cable is never to be allowed to
come into contact with either the pipe or the
pump. Furthermore, it must be completely
shielded against moisture.
Property damage is possible!
Because of operational settings, an incor-
rectly disconnected core in the connec-
tion area could damage the frequency
converter.
• Disconnect the core at both of its end
points from electrical connection
• Pull it off
English
WILO SE 05/2008
17
Details concerning the electrical connections - loosen screws and remove upper cover of the frequency converter.
Mains connection
Connect three lines of the cable to the
3 connection terminals of the board.
(Phase + Neutral+ Earth).
Connecting the inputs/outputs
3 operating modes exist:
(see Chapter 6: Commissioning)
manual mode:
Mode 1
Pressure regulation:
Mode 2
Operation by external control:
Mode 3
NOTE: The configuration at the time of
delivery is either Mode 1-3 or Mode 2,
depending on the desired type of pump
control unit. A programming key is used
to switch from Mode 1-3 to Mode 2 (or vice-
versa); an after-sales service employee must
be called in.
Cores
Ø 2.5 mm2
Connection terminal
Main fuse 20 A
Connection terminals
inputs/outputs
(see
Fig. 3,
Pos. 20)
(see
Fig. 3)
+24 V DC max. 30 mA
+10 V DC max. 30 mA
Zero Volt
External ON/OFF
Error relays
potential-free contact: 250 V–1 A
1
2
3
4
5
6
7
8
9 10 11 12 13 14
L
N
ATTENTION!
PE
+24 V
+24 V
0 V
+10 V
ATTENTION!
Installation and operating instructions MHIE 1~
18
1 - Connection of the pressure sensor
Connection of the inputs/outputs
Connection terminals Inputs/outputs of the frequency converter
Diagram
Pressure sensor 4-20 mA (*)
• 2 cores (4-20 mA / +24 V)
• 3 cores (0 V / 4-20 mA / +24 V)
or
Pressure sensor 0-10 V (**)
• 3 cores (0 V / 0-10 V / +24 V)
1
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
0 V
4-20 mA
+24 V
*
0 V
0-10 V
+24 V
**
2 - Connection of the potentiometer
Connection terminals Inputs/outputs of the frequency converter
Diagram
Adjusting the setpoint with the
aid of the potentiometer
Adjusting the setpoint via
external control
•
0-20 mA (*)
or
•
0-10 V (**)
2
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
3
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
0-20 mA
0 V
*
0-10 V
0 V
**
1
2
3
4
5
6
7
WILO SE 05/2008
19
3 - Settings of the control terminals (Terminals 7 to 14)
Connection terminals of the inputs/outputs of the frequency converter
Diagram
4
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
5
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
6
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
7
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
4 - Possible connections
It is possible to start or stop the pump with the
external control(*) (potential-free contact);
this function takes precedence over the other
functions.
This external control can be removed by bridging
the terminals (11 and 12).
Examples: Float switches,
low water pressure switches, etc.
The frequency converter is equipped with an
error relay with normally open contact (**):
Contact open = frequency converter is receiving
no voltage or is defective
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
*
1
10 V
0 V
+24 V
+24 V
2
3
4
5
6
7
8
9
10
11
12
13
14
**
Property damage is possible!
The cover of the frequency converter
must be easy to close.
• Put plug connections carefully in place
in the interior of the frequency con-
verter before sealing it.
English
Installation and operating instructions MHIE 1~
20
Operating modes and diagrams
Diagrams
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
2
4
3
6
3
2
1
4
2
1
5
3
1
6
3
1
4
3
1
7
3
1
5
4
ATTENTION!
Operating modes
Mode 1
Mode 3 – 0-20 mA
Mode 3 – 0-10 V
Mode 2 – PI control – sensor: 4-20 mA
Mode 2 – PI control – sensor: 0-10 V
Mode 2 – PI control – sensor: 4-20 mA – External control of the setpoint:
0-20 mA
Mode 2 – PI control – sensor: 4-20 mA – External control of the setpoint:
0-10 V
Mode 2 – PI control – sensor: 0-10 V
– External control of the setpoint:
0-20 mA
Mode 2 – PI control – sensor: 0-10 V
– External control of the setpoint:
0-10 V
WILO SE 05/2008
21
Control regulations in Mode 2
External control of the setpoint in Mode 2
External control of the frequency in Mode 3
Value in % of the maxi-
mum pressure measure-
ment range of the sensor
100%
0
4
20
Sensor 4-20 mA
Between 0 and 4 mA it is assumed that the
cable is disconnected.
Input current level (mA)
Value in % of the maximum
pressure measurement range
of the sensor
100%
0
10
Sensor 0-10 V
Input voltage (V)
Pressure in % of the
sensor measurement
range
100%
0
2
20
Setpoint 0-20 mA
Range in which the frequency converter stops.
Input current level (mA)
Pressure in % of the
sensor measurement
range
100%
0
1
10
Setpoint 0-10 V
Range in which the frequency converter stops.
Input voltage (V)
Frequency of the
frequency
converter
100%
40%
0
2
20
External signal 0-20 mA
Range in which the frequency converter stops.
Input current level (mA)
Frequency of the
frequency
converter
100%
40%
0
1
10
External signal 0-10 V
Range in which the frequency converter stops.
Input voltage (V)
10%
10%
Installation and operating instructions MHIE 1~
22
6 Commissioning
If the pump is supplied separately, i.e. if
it is not integrated in a system that has
been mounted by us, then the configu-
ration type at the time of delivery is
either Mode 1-3 or Mode 2, depending
on the type of pump control desired.
As a reminder: A programming key is
used to switch from Mode 1-3 to Mode 2
(or vice-versa); an after-sales service
employee must be called in.
6.1 Settings
- In manual mode: Mode 1 (see Figs. 1, 2).
The duty point of the pump is reached with the
aid of the potentiometer (see Fig. 9, Pos. 19) by
setting the speed of the motor between 40% and
100% of the maximum speed.
We recommend that the motor speed be set to
70 % for commissioning.
- The pump can be brought to a standstill (frequen-
cy converter under tension) with the remote con-
trol unit (switch).
- In pressure regulation operating mode: Mode 2
(see Figs. 6, 7, 8).
It is possible to regulate the pressure of the
pump through the addition of a pressure sensor
and a diaphragm pressure vessel. The sensor
must exhibit an accuracy of <1% and be used in
a range between 30% and 100% of its measure-
ment range; the reservoir has a useable volume
of at least 8 litres.
No water in the diaphragm pressure vessel.
Pump up the diaphragm pressure vessel to a
pressure that is 0.3 bar less than the control
pressure of the pump (diaphragm pressure ves-
sel and sensor kit included as accessories in the
scope of delivery).
The setpoint for the pressure regulation is speci-
fied in two types:
• The setting of the potentiometer indicates for
the setpoint for a value between 0 and 100% of
the measurement range of the sensor. We rec-
ommend that the potentiometer be set to
100% for commissioning.
• An external signal can be connected (0-10 V or
0-20 mA) for setting the setpoint by remote
control (see Chapter 5.3 - Electrical connec-
tions).
NOTE: The function "Detection of zero volume
flow" makes it possible to stop the pump.
- Via external control per frequency: Mode 3 (see
Fig. 10).
The potentiometer has no function in Mode 3, but
it must nonetheless be set to 100%. The pump is
controlled by an external signal.
Specifications concerning commissioning: see
instruction manual for the pressure boosting sys-
tem.
During normal operation, the status of the LEDs
is as follows: (see Fig. 9, Pos. 17 + 18)
6.2 Preparatory flushing
Because our pumps are hydraulically tested in
the factory, it is possible that there is still water
in their interiors. For reasons of hygiene, it is
therefore recommended that they be flushed
out prior to use in a potable water network.
6.3 Filling - bleeding
Never permit the pump to run dry, not
even for a brief moment.
Pump in intake mode (see Fig. 2)
- Close the stop valve on the pressure side (Pos. 3),
open the inlet/bleeder screw (Pos. 5).
- Gradually open the valve that is located on the
pipework at the entry to the pump (Pos. 2) and
carry out the complete filling of the pump.
Retighten the screw firmly after water begins to
emerge and ventilation is complete.
Danger of injury to personnel!
A jet of water can escape from the ventilation
opening when hot water is being pumped.
Initiate all necessary precautionary measures to
ensure that personnel and the motor/frequency
converter are protected!
Pump in suction mode (see Fig. 1) Two different
cases are possible.
1st case (see Fig. 4.1)
- Close the stop valve on the pressure side
(see Fig. 1, Pos. 3).
- Open the stop valve on suction side (see Fig. 1,
Pos. 2).
- Unscrew the inlet/bleeder screw (see Fig. 1, Pos. 5),
that is located on the pump housing.
- Fill the pump and suction line completely with the
aid of a funnel inserted into the opening.
- The filling procedure is finished when water
escapes and ventilation is complete.
- Screw the inlet/bleeder screw back on.
2nd case (see Fig. 4.2)
The filling can be made easier if a pipe equipped
with a cock (Pos. 12) Ø 1/2" and a funnel
is mounted perpendicularly on the suction line
of the pump.
- Close the stop valve on the pressure side
(see Fig. 1, Pos. 3).
- Open the stop valve on suction side (see Fig. 1,
Pos. 2).
- Open cock (see Fig. 4, Pos. 12) and inlet/bleeder
screw (see Fig. 1, Pos. 5).
- Fill pump and suction line completely, until bub-
ble-free water escapes from the filling opening.
- Close the cock (see Fig. 4, Pos. 12) (it can remain
mounted on the pipe), remove the pipe and screw
the inlet/bleeder screw back in.
Frequency converter voltage
on
off
load/pump in operation
Frequency converter voltage
on
off
load/pump in standstill
Status of the LEDs
green LED
red LED
ATTENTION!
ATTENTION!
WILO SE 05/2008
23
6.4 Starting
Depending on the temperature of the fluid and
on the operating cycles of the pump, the sur-
face temperature (pump, motor) may exceed
68°C: mount suitable personnel protection
apparatus as needed.
The pump should not be permitted to be
operated longer than ten minutes with
zero flow when the gate valve is closed
on the pressure side.
We recommend that a minimum flow level of
approximately 10% of the nominal throughput of
the pump be maintained in order to ensure that
no blow hole forms in the upper part of the pump.
- Open the stop valve on the pressure side and start
the pump.
- Check the uniformity of the pressure on the dis-
charge side with the aid of a pressure gauge;
bleed the pump again or refill it in the event of
deviations.
- Check current consumption. The current con-
sumption may not exceed the specification on
the pump shield.
7 Maintenance
The pump(s) must be de-energised and
all non-authorised restarts must be pre-
vented before any maintenance work is
done.
Never undertake maintenance work while the
pump is running. Always keep pump and
motor/frequency converter in clean condition.
When set up in frost-free locations, the pump
should not be emptied, even with prolonged
decommissioning.
To prevent blockage of the shaft and of the
hydraulic apparatus, the pump is to be emptied
during periods of potential frost by unscrewing
the drainage and inlet/bleeding screw (Fig. 1+2,
Pos. 5+6). Screw both screws back in without
tightening them.
Replacement frequencies
NOTE: These can only be regarded as recommen-
dations, because the frequency of replacement is
dependent on operating conditions within the
group involving
• Temperature, pressure and quality of the fluid for
the mechanical seal.
• Pressure and ambient temperature for the motor
and other components.
• Frequency of start-up: continuous or intermittent
operation.
ATTENTION!
ATTENTION!
Installation and operating instructions MHIE 1~
8 Operating faults
De-energise the pump before each
intervention and secure against non-
authorised restarts!
All of the incidents listed below will lead to
a switch-off via the error relay.
De-energise the pump before each intervention.
If the fluid is toxic, corrosive or hazardous for
personnel, then WILO or the authorised repair
company must be informed of the situation.
Clean the pump in such cases in order to ensure
absolute safety for the craftsmen performing
the repairs.
If the pump is at a complete standstill and an intervention is required, disconnect the power supply, wait until the LEDs have gone out completely, eliminate the fault
and reconnect the power supply. If a major fault is present, then an after-sales service employee must be called in.
If the operating fault cannot be rectified, then please
contact your local professional tradesmen or the Wilo
after-sales service in your vicinity.
ATTENTION!
Display
Frequency converter
behaviour
Fault/possible causes
Elimination
Green
LED
Red
LED
Reaction time
up to standstill
Frequency
converter
Waiting time
before
switching
back on
Relay status
Contact
Off
On
No standstill
/
Open
a) Frequency converter sup-
ply has undervoltage.
- Check voltage at the
terminals of the
frequency converter.
Off
On
Immediate
No switching
back on
Open
b) Frequency converter
supply has overvoltage.
- Check voltage at the
terminals of the
frequency converter.
Off
On
Immediate
No switching
back on
Open
c) The motor has a short-
circuit.
- Dismantle motor/
frequency converter
of the pump and have
it checked or replace
it.
Off
On
<10 s
No switching
back on
Open
d) The pump is overloaded.
- excessive density and/
or viscosity of the
pumped fluid.
Off
On
<60 s
No switching
back on
Open
e) The sensor cable
(4-20 mA) is disconnected
(only Mode 2).
- Check correct current
supply and cabling of
the sensor.
Other, pump-specific faults not detectable by
the frequency converter.
English
WILO SE 05/2008
25
9 Spare parts
Spare parts must be ordered from the local
authorised dealer and/or from Wilo after-sales
service. In order to avoid unnecessary inquiries or
incorrect orders, specify at the time of your order
all of the data listed on the name plate.
Subject to technical changes without prior
notice!
Faults
Causes
Elimination
8.1 The pump is
running but does
not pump
anything
8.2 The pump is
vibrating
8.3 The pump does
not provide
sufficient pressure
8.4 The delivery rate
is irregular
a) The pump is not running fast
enough:
b) Interior parts are blocked by foreign
matter:
c) Suction line is blocked:
d) Air intake through suction line:
e) The pump has run empty:
f) The suction pressure is too weak,
cavitation noise is occurring
generally:
a) Poorly mounted to the pedestal:
b) Foreign matter is blocking the
pump:
c) Difficult pump rotation:
a) Insufficient motor speed:
b) The motor is defective:
c) Insufficient pump filling:
d) The drainage screw is not screwed in
all the way:
a) The suction head (Ha) has not been
maintained:
b) The suction line has a smaller circ-
umference than that of the pump:
c) Suction strainer and suction line are
partially blocked:
a) Check correct setting of the nominal values (setpoints)
(matching of the nominal value points).
b)Dismantle pump, replace defective parts, perform
cleaning.
c) Clean the entire pipework.
d)Check the impermeability of the entire pipe up to the
pump and seal.
e)Refill the pump. Check the impermeability of the foot
valve.
f) Excessively large suction pressure losses or excessively
large suction head. (check the Net Positive Suction
Head of the installed pump and of the installation).
a) Check and tighten the nuts on the pedestal bolts.
b)Dismantle and clean the pump.
c) Check whether the pump rotates freely without
encountering abnormal resistance.
a) Check correct setting of the nominal values (setpoints)
(matching of the nominal value points).
b)Have the motor/frequency converter replaced.
c) Open the drain cock of the pump and bleed until there
is a complete absence of bubbles.
d)Check drainage screw and screw in as needed.
a) Consult the installation conditions and recommen-
dations contained in these Installation and operating
instructions.
b)The suction line must have the same diameter as the
suction inlet of the pump.
c) Dismount and clean.
EG - Konformitätserklärung
GB
EC – Declaration of conformity
F
Déclaration de conformité CEE
Hiermit erklären wir, dass die Bauarten der Baureihe :
MVIE 1ph
Herewith, we declare that this product:
MHIE 1ph
Par le présent, nous déclarons que cet agrégat :
in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entspricht:
in its delivered state comply with the following relevant provisions:
est conforme aux dispositions suivants dont il relève:
EG-Maschinenrichtlinie
98/37/EG
EC-Machinery directive
Directives CEE relatives aux machines
Elektromagnetische Verträglichkeit - Richtlinie
2004/1008/EG
Electromagnetic compatibility - directive
Compatibilité électromagnétique- directive
Niederspannungsrichtlinie
2006/95/EG
Low voltage directive
Direction basse-tension
Angewendete harmonisierte Normen, insbesondere:
EN 809
Applied harmonized standards, in particular:
EN 60204-1
Normes harmonisées, notamment:
EN 61800-3
Bei einer mit uns nicht abgestimmten technischen Änderung der oben genannten Bauarten, verliert diese Erklärung ihre Gültigkeit.
If the above mentioned series are technically modified without our approval, this declaration shall no longer be applicable.
Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité.
Dortmund, 05.09.2008
Erwin Prieß
Quality Manager
WILO SE
Nortkirchenstraße 100
44263 Dortmund
Document: 2089935.2
NL EG-verklaring van overeenstemming
Hiermede verklaren wij dat dit aggregaat in de
geleverde uitvoering voldoet aan de volgende
bepalingen:
EG-richtlijnen betreffende machines 98/37/EG
Elektromagnetische compatibiliteit
2004/1008/EG
EG-laagspanningsrichtlijn 2006/95/EG
Gebruikte geharmoniseerde normen, in het
bijzonder: 1)
I
Dichiarazione di conformità CE
Con la presente si dichiara che i presenti prodotti
sono conformi alle seguenti disposizioni e
direttive rilevanti:
Direttiva macchine 98/37/CE
Compatibilità elettromagnetica 2004/1008/EG
Direttiva bassa tensione 2006/95/EG
Norme armonizzate applicate, in particolare: 1)
E
Declaración de conformidad CE
Por la presente declaramos la conformidad del
producto en su estado de suministro con las
disposiciones pertinentes siguientes:
Directiva sobre máquinas 98/37/CE
Directiva sobre compatibilidad electromagnética
2004/1008/EG
Directiva sobre equipos de baja tensión
2006/95/EG
Normas armonizadas adoptadas, especialmente: 1)
P
Declaração de Conformidade CE
Pela presente, declaramos que esta unidade no
seu estado original, está conforme os seguintes
requisitos:
Directivas CEE relativas a máquinas 98/37/CE
Compatibilidade electromagnética 2004/1008/EG
Directiva de baixa voltagem 2006/95/EG
Normas harmonizadas aplicadas, especialmente: 1)
S
CE- försäkran
Härmed förklarar vi att denna maskin i levererat
utförande motsvarar följande tillämpliga
bestämmelser:
EG–Maskindirektiv 98/37/EG
EG–Elektromagnetisk kompatibilitet –
2004/1008/EG
EG–Lågspänningsdirektiv 2006/95/EG
Tillämpade harmoniserade normer, i synnerhet: 1)
N
EU-Overensstemmelseserklæring
Vi erklærer hermed at denne enheten i utførelse
som levert er i overensstemmelse med følgende
relevante bestemmelser:
EG–Maskindirektiv 98/37/EG
EG–EMV–Elektromagnetisk kompatibilitet
2004/1008/EG
EG–Lavspenningsdirektiv 2006/95/EG
Anvendte harmoniserte standarder, særlig: 1)
FIN CE-standardinmukaisuusseloste
Ilmoitamme täten, että tämä laite vastaa
seuraavia asiaankuuluvia määräyksiä:
EU–konedirektiivit: 98/37/EG
Sähkömagneettinen soveltuvuus 2004/1008/EG
Matalajännite direktiivit: 2006/95/EG
Käytetyt yhteensovitetut standardit, erityisesti: 1)
DK EF-overensstemmelseserklæring
Vi erklærer hermed, at denne enhed ved levering
overholder følgende relevante bestemmelser:
EU–maskindirektiver 98/37/EG
Elektromagnetisk kompatibilitet: 2004/1008/EG
Lavvolts-direktiv 2006/95/EG
Anvendte harmoniserede standarder, særligt: 1)
H
EK. Azonossági nyilatkozat
Ezennel kijelentjük,hogy az berendezés az
alábbiaknak megfelel:
EK Irányelvek gépekhez: 98/37/EG
Elektromágneses zavarás/türés: 2004/1008/EG
Kisfeszültségü berendezések irány-Elve:
2006/95/EG
Felhasznált harmonizált szabványok, különösen: 1)
CZ Prohlášení o shodě EU
Prohlašujeme tímto, že tento agregát v dodaném
provedení odpovídá následujícím příslušným
ustanovením:
Směrnicím EU–strojní zařízení 98/37/EG
Směrnicím EU–EMV 2004/1008/EG
Směrnicím EU–nízké napětí 2006/95/EG
Použité harmonizační normy, zejména: 1)
PL Deklaracja Zgodności CE
Niniejszym deklarujemy z pełną odpowiedzialnoscią
że dostarczony wyrób jest zgdony z następującymi
dokumentami:
EC–dyrektywa dla przemysłu maszynowego
98/37/EG
Odpowiedniość elektromagnetyczna
2004/1008/EG
Normie niskich napięć 2006/95/EG
Wyroby są zgodne ze szczegółowymi normami
zharmonizowanymi: 1)
RUS Деклация о соответствии Европейским
нормам
Настоящим документом заявляем, что данный
агрегат в его объеме поставки соответствует
следующим нормативным документам:
Директивы EC в отношении машин 98/37/EG
Электромагнитная устойчивость
2004/1008/EG
Директивы по низковольтному напряжению
2006/95/EG
Используемые согласованные стандарты и
нормы, в частности : 1)
GR
Δήλωση προσαρ ογής της Ε.Ε.
Δηλώνου ε ότι το προϊόν αυτό σ’ αυτή την
κατάσταση παράδοσης ικανοποιεί τις ακόλουθες
διατάξεις :
Οδηγίες EG για ηχανή ατα 98/37/EG
Ηλεκτρο αγνητική συ βατότητα -2004/1008/EG
Οδηγία χα ηλής τάσης 2006/95/EG
Εναρ ονισ ένα χρησι οποιού ενα πρότυπα,
ιδιαίτερα: 1)
TR CE Uygunluk Teyid Belgesi
Bu cihazın teslim edildiği ºekliyle aºağıdaki
standartlara uygun olduğunu teyid ederiz:
AB-Makina Standartları 98/37/EG
Elektromanyetik Uyumluluk 2004/1008/EG
Alçak gerilim direktifi 2006/95/EG
Kısmen kullanılan standartlar: 1)
1) EN 809
EN 60204-1
EN 61800-3
Erwin Prieß
Quality Manager
WILO SE
Nortkirchenstraße 100
44263 Dortmund
T +49 231 4102-0
F +49 231 4102-7363
[email protected]
www.wilo.com
Algeria
Bad Ezzouar, Dar El Beida
T +213 21 247979
[email protected]
Armenia
375001 Yerevan
T +374 10 544336
[email protected]
Bosnia and Herzegovina
71000 Sarajevo
T +387 33 714510
[email protected]
Georgia
0177 Tbilisi
T +995 32317813
[email protected]
Macedonia
1000 Skopje
T +389 2 3122058
[email protected]
Moldova
2012 Chisinau
T +373 2 223501
[email protected]
Rep. Mongolia
Ulaanbaatar
T +976 11 314843
[email protected]
Tajikistan
734025 Dushanbe
T +992 37 2232908
[email protected]
Turkmenistan
744000 Ashgabad
T +993 12 345838
[email protected]
Uzbekistan
700046 Taschkent
[email protected]
August 2008
Wilo – International (Subsidiaries)
Wilo – International (Representation offices)
Argentina
WILO SALMSON
Argentina S.A.
C1270ABE Ciudad
Autónoma de Buenos Aires
T +54 11 43015955
[email protected]
Austria
WILO Handelsges. m.b.H.
1230 Wien
T +43 507 507-0
[email protected]
Azerbaijan
WILO Caspian LLC
1065 Baku
T +994 12 5962372
[email protected]
Belarus
WILO Bel OOO
220035 Minsk
T +375 17 2503393
[email protected]
Belgium
WILO SA/NV
1083 Ganshoren
T +32 2 4823333
[email protected]
Bulgaria
WILO Bulgaria Ltd.
1125 Sofia
T +359 2 9701970
[email protected]
Canada
WILO Canada Inc.
Calgary, Alberta T2A 5L4
T +1 403 2769456
[email protected]
China
WILO China Ltd.
101300 Beijing
T +86 10 80493900
[email protected]
Croatia
WILO Hrvatska d.o.o.
10090 Zagreb
T +38 51 3430914
[email protected]
Czech Republic
WILO Praha s.r.o.
25101 Cestlice
T +420 234 098711
[email protected]
Denmark
WILO Danmark A/S
2690 Karlslunde
T +45 70 253312
[email protected]
Estonia
WILO Eesti OÜ
12618 Tallinn
T +372 6509780
[email protected]
Finland
WILO Finland OY
02330 Espoo
T +358 207401540
[email protected]
France
WILO S.A.S.
78390 Bois d'Arcy
T +33 1 30050930
[email protected]
Great Britain
WILO (U.K.) Ltd.
DE14 2WJ Burton-
Upon-Trent
T +44 1283 523000
[email protected]
Greece
WILO Hellas AG
14569 Anixi (Attika)
T +302 10 6248300
[email protected]
Hungary
WILO Magyarország Kft
2045 Törökbálint
(Budapest)
T +36 23 889500
[email protected]
Ireland
WILO Engineering Ltd.
Limerick
T +353 61 227566
[email protected]
Italy
WILO Italia s.r.l.
20068 Peschiera
Borromeo (Milano)
T +39 25538351
[email protected]
Kazakhstan
WILO Central Asia
050002 Almaty
T +7 727 2785961
[email protected]
Korea
WILO Pumps Ltd.
621-807 Gimhae
Gyeongnam
T +82 55 3405800
[email protected]
Latvia
WILO Baltic SIA
1019 Riga
T +371 67 145229
[email protected]
Lebanon
WILO SALMSON
Lebanon
12022030 El Metn
T +961 4 722280
[email protected]
Lithuania
WILO Lietuva UAB
03202 Vilnius
T +370 5 2136495
[email protected]
The Netherlands
WILO Nederland b.v.
1948 RC Beverwijk
T +31 251 220844
[email protected]
Norway
WILO Norge AS
0901 Oslo
T +47 22 804570
[email protected]
Poland
WILO Polska Sp. z.o.o.
05-090 Raszyn
T +48 22 7026161
[email protected]
Portugal
Bombas Wilo-Salmson
Portugal Lda.
4050-040 Porto
T +351 22 2080350
[email protected]
Romania
WILO Romania s.r.l.
077040 Com. Chiajna
Jud. Ilfov
T +40 21 3170164
[email protected]
Russia
WILO Rus ooo
123592 Moscow
T +7 495 7810690
[email protected]
Saudi Arabia
WILO ME - Riyadh
Riyadh 11465
T +966 1 4624430
[email protected]
Serbia and Montenegro
WILO Beograd d.o.o.
11000 Beograd
T +381 11 2851278
[email protected]
Slovakia
WILO Slovakia s.r.o.
82008 Bratislava 28
T +421 2 45520122
[email protected]
Slovenia
WILO Adriatic d.o.o.
1000 Ljubljana
T +386 1 5838130
[email protected]
South Africa
Salmson South Africa
1610 Edenvale
T +27 11 6082780
errol.cornelius@
salmson.co.za
Spain
WILO Ibérica S.A.
28806 Alcalá de Henares
(Madrid)
T +34 91 8797100
[email protected]
Sweden
WILO Sverige AB
35246 Växjö
T +46 470 727600
[email protected]
Switzerland
EMB Pumpen AG
4310 Rheinfelden
T +41 61 83680-20
[email protected]
Taiwan
WILO-EMU Taiwan Co. Ltd.
110 Taipeh
T +886 227 391655
nelson.wu@
wiloemutaiwan.com.tw
Turkey
WILO Pompa Sistemleri
San. ve Tic. A.S¸.
34530 Istanbul
T +90 216 6610211
[email protected]
Ukraina
WILO Ukraina t.o.w.
01033 Kiew
T +38 044 2011870
[email protected]
Vietnam
Pompes Salmson Vietnam
Ho Chi Minh-Ville Vietnam
T +84 8 8109975
[email protected]
United Arab Emirates
WILO ME - Dubai
Dubai
T +971 4 3453633
[email protected]
USA
WILO-EMU USA LLC
Thomasville,
Georgia 31792
T +1 229 5840097
[email protected]
USA
WILO USA LLC
Melrose Park, Illinois 60160
T +1 708 3389456
mike.easterley@
wilo-na.com
T 0231 4102-0
F 0231 4102-7363
[email protected]
www.wilo.de
G1 Nord
WILO SE
Vertriebsbüro Hamburg
Beim Strohhause 27
20097 Hamburg
T 040 5559490
F 040 55594949
[email protected]
G2 Ost
WILO SE
Vertriebsbüro Berlin
Juliusstraße 52–53
12051 Berlin-Neukölln
T 030 6289370
F 030 62893770
[email protected]
G3 Sachsen/Thüringen
WILO SE
Vertriebsbüro Dresden
Frankenring 8
01723 Kesselsdorf
T 035204 7050
F 035204 70570
[email protected]
G4 Südost
WILO SE
Vertriebsbüro München
Landshuter Straße 20
85716 Unterschleißheim
T 089 4200090
F 089 42000944
[email protected]
G5 Südwest
WILO SE
Vertriebsbüro Stuttgart
Hertichstraße 10
71229 Leonberg
T 07152 94710
F 07152 947141
[email protected]
G6 Rhein-Main
WILO SE
Vertriebsbüro Frankfurt
An den drei Hasen 31
61440 Oberursel/Ts.
T 06171 70460
F 06171 704665
[email protected]
G7 West
WILO SE
Vertriebsbüro Düsseldorf
Westring 19
40721 Hilden
T 02103 90920
F 02103 909215
[email protected]
Kompetenz-Team
Gebäudetechnik
WILO SE
Nortkirchenstraße 100
44263 Dortmund
T 0231 4102-7516
T 01805 R•U•F•W•I•L•O*
7•8•3•9•4•5•6
F 0231 4102-7666
Kompetenz-Team
Kommune
Bau + Bergbau
WILO EMU GmbH
Heimgartenstraße 1
95030 Hof
T 09281 974-550
F 09281 974-551
Werkskundendienst
Gebäudetechnik
Kommune
Bau + Bergbau
Industrie
WILO SE
Nortkirchenstraße 100
44263 Dortmund
T 0231 4102-7900
T 01805 W•I•L•O•K•D*
9•4•5•6•5•3
F 0231 4102-7126
Erreichbar Mo–Fr von
7–17 Uhr.
Wochenende und feiertags
9–14 Uhr elektronische
Bereitschaft mit
Rückruf-Garantie!
–Kundendienst-Anforderung
–Werksreparaturen
–Ersatzteilfragen
–Inbetriebnahme
–Inspektion
–Technische Service-Beratung
–Qualitätsanalyse
Wilo-International
Österreich
Zentrale Wien:
WILO Handelsgesellschaft mbH
Eitnergasse 13
1230 Wien
T +43 507 507-0
F +43 507 507-15
Vertriebsbüro Salzburg:
Gnigler Straße 56
5020 Salzburg
T +43 507 507-13
F +43 507 507-15
Vertriebsbüro Oberösterreich:
Trattnachtalstraße 7
4710 Grieskirchen
T +43 507 507-26
F +43 507 507-15
Schweiz
EMB Pumpen AG
Gerstenweg 7
4310 Rheinfelden
T +41 61 83680-20
F +41 61 83680-21
Standorte weiterer
Tochtergesellschaften
Argentinien, Aserbaidschan,
Belarus, Belgien, Bulgarien,
China, Dänemark, Estland,
Finnland, Frankreich,
Griechenland, Großbritannien,
Irland, Italien, Kanada,
Kasachstan, Korea, Kroatien,
Lettland, Libanon, Litauen,
Niederlande, Norwegen,
Polen, Portugal, Rumänien,
Russland, Saudi-Arabien,
Schweden, Serbien und
Montenegro, Slowakei,
Slowenien, Spanien,
Südafrika, Taiwan,
Tschechien, Türkei, Ukraine,
Ungarn, Vereinigte Arabische
Emirate, Vietnam, USA
Die Adressen finden Sie unter
www.wilo.de oder
www.wilo.com.
Stand August 2008
Erreichbar Mo–Fr von 7–18 Uhr.
–Antworten auf
– Produkt- und Anwendungsfragen
– Liefertermine und Lieferzeiten
–Informationen über Ansprechpartner vor Ort
–Versand von Informationsunterlagen
* 14 Cent pro Minute aus dem deutschen Festnetz
der T-Com. Bei Anrufen aus Mobilfunknetzen
sind Preisabweichungen möglich.
Wilo-Vertriebsbüros in Deutschland