Pioneering for You

2 133 933-Ed.02 / 2013-11-Wilo de Einbau- und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

200 mm min.

100 mm min. 5 1 7 2 2% 6 4 3 7 12 13 Fig. 2: 8 7 3 4 6 2 7 2 A 4 11 10 9 5 HC B A(B) 3

Einbau- und Betriebsanleitung

4 en Installation and operating instructions 18 fr Notice de montage et de mise en service 32 nl Inbouw- en bedieningsvoorschriften 48

WILO SE 11/2013

Installation and operating instructions 1 General About this document The language of the original operating instructions is English. All other languages of these instructions are translations of the original oper- ating instructions. These installation and operating instructions are an integral part of the product. They must be kept readily available at the place where the product is installed. Strict adherence to these instructions is a precondition for the proper use and correct operation of the product. The installation and operating instructions correspond to the relevant version of the product and the underlying safety regulations and standards valid at the time of going to print. EC declaration of conformity: A copy of the EC declaration of conformity is a component of these operating instructions. If a technical modification is made on the designs named there with- out our agreement or the declarations made in the installation and operating instructions on the safety of the product/personnel are not observed, this declaration loses its validity. 2 Safety These operating instructions contain basic information which must be adhered to during installation, operation and maintenance. For this reason, these operating instructions must, without fail, be read by the service technician and the responsible specialist/operator before installation and commissioning. It is not only the general safety instructions listed under the main point “safety” that must be adhered to but also the special safety instructions with danger symbols included under the following main points. 2.1 Indication of instructions in the operating instructions Symbols General danger symbol Danger from electrical voltage NOTE Signal words DANGER! Acutely dangerous situation Non-observance results in death or the most serious of injuries. WARNING! The user can suffer (serious) injuries. “Warning” implies that (seri- ous) injury to persons is probable if this information is disregarded. CAUTION! There is a risk of damaging the product/unit. “Caution” implies that damage to the product is likely if this information is disregarded. NOTE: Useful information on handling the product. It draws attention to possible problems.

Installation and operating instructions Wilo-BAC

19 Information applied directly to the product, such as: • Arrows indicating the direction of rotation, • Identification for fluid connections, • Rating plates and • Warning stickers, must be strictly complied with and kept in a fully legible condition. 2.2 Personnel qualifications The installation, operating and maintenance personnel must have the appropriate qualifications for this work. The area of accountability, responsibility and personnel monitoring are to be ensured by the operator. If the personnel are not in possession of the necessary knowledge, they are to be trained and instructed. This can be accom- plished if necessary by the manufacturer of the product at the request of the operator. 2.3 Danger in the event of non- observance of the safety instructions Non-observance of the safety instructions can result in risk of injury to persons and damage to the product/unit as well as environmental hazards. Non-observance of the safety instructions results in the loss of any claims to damages. In particular, lack of care may lead to problems such as: • Danger to persons from electrical, mechanical and bacteriological influences. • Pollution of the environment due to leakage of hazardous materials • Damage to property • Failure of important product/unit functions • Failure of required maintenance and repair procedures 2.4 Safety consciousness on the job The safety instructions included in these installation and operating instructions, the existing national regulations on accident prevention together with any internal working, operating and safety regulations of the operator are to be complied with. 2.5 Safety instructions for the operator This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of expe- rience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. • If hot or cold components on the product/unit cause hazards, meas- ures must be taken by the customer to prevent them from being touched. • Guards which prevent moving components (such as the coupling) from being touched must not be removed whilst the product is in operation. • Leakages (e.g. from a shaft seal) of hazardous fluids (e.g. explosive, toxic or hot) must be led away so that no danger to persons or to the environment arises. National statutory provisions are to be observed. • Danger from electrical current must be eliminated. Local directives or general directives [e.g. IEC, VDE etc.] and local power supply compa- nies must be adhered to. 2.6 Safety instructions for installation and maintenance work The operator must ensure that all installation and maintenance work is carried out by authorised and qualified personnel, who are sufficiently informed from their own detailed study of the operating instructions. Work on the product/unit must only be carried out when at a stand- still. It is mandatory that the procedure described in the installation and operating instructions for shutting down the product/unit be complied with.

WILO SE 11/2013

Immediately on conclusion of the work, all safety and protective devices must be put back in position and/or recommissioned. 2.7 Unauthorised modification and manufacture of spare parts Unauthorised modification and manufacture of spare parts will put the safety of the product/personnel at risk and invalidate the state- ments on safety made by the manufacturer. Modifications to the product are only permissible after consultation with the manufacturer. Original spare parts and accessories author- ised by the manufacturer ensure safety. The use of other parts can nullify the liability from the results of the usage. 2.8 Improper use The operating safety of the supplied product is only guaranteed when used properly in accordance with the section in the operating instruc- tions titled “Intended use”. The limit values must on no account fall under or exceed those specified in the catalogue/data sheet. 3 Transport and interim storage 3.1 Shipping The pump is delivered from the factory packaged in a cardboard box or secured to a pallet and protected against dust and moisture. Transport inspection On arrival, inspect the pump immediately for any transport damage. If damage is found, the necessary procedure involving the forwarding agent must be taken within the specified period. Storage Before installation, the pump must be kept dry, frost-free and pro- tected from mechanical damage. CAUTION! Risk of damage due to incorrect packaging! If the pump is transported again at a later time, it must be packaged so that it cannot be damaged during transport. • Use the original packaging for this, or select equivalent packaging Handling Handle the pump with care to avoid any damage of the product before installing it. 3.2 Transport for installation/removal purposes WARNING! Risk of personal injury! Improper transport can lead to personal injury. • The pump must be transported using approved load-bearing equipment (e.g. block and tackle, crane, etc.). This must be secured to the pump flanges and, if necessary, to the external diameter of the motor (protection against slipping is required!). • Never stand underneath a suspended load. • Make sure the pump is securely positioned and is stable during storage and transport as well as prior to all installation and other assembly work. 4 Intended use Purpose BAC pumps are single-stage centrifugal pumps that are used for fluid circulation in buildings, agriculture and industry. Fields of application They may be used for: • Cooling systems • Cold and hot water systems • Industrial water systems • Industrial circulation systems

Installation and operating instructions Wilo-BAC

21 Restrictions The pumps are exclusively intended for installation and operation in enclosed rooms. Typical installation locations are technical rooms within the building with other domestic installations. No provision has been made for direct installation of the device in rooms used for other purposes (residential and work rooms). The following is not permitted: • Outdoor installation and operation outdoors CAUTION! Risk of property damage! Unpermitted substances in the fluid can destroy the pump. Abra- sive solids (e.g. sand) increase pump wear. Pumps without an Ex certificate are not suitable for use in poten- tially explosive areas. • The correct use of the pump/installation also includes following these instructions. • Any other use is considered to be incorrect use. 5 Product information 5.1 General Minimum efficiency index MEI: The benchmark for most efficient water pumps is MEI ≥ 0,70. NOTE For detailed information on the MEI values of the pump types, see: Wilo online catalogue, available at www.wilo.com The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system. Information on benchmark efficiency is available at www.europump.org/efficiencycharts 5.2 Type key The type key consists of the following elements: Beispiel: BAC 40-134/2,2/2-DM/R BAC Bloc Air Conditioning Single-stage horizontal pump in monobloc construc- tion 40 Diameter of pressure port [mm] -134 Impeller diameter [mm] /2,2 Rated motor power P2 [kW] /2 Number of poles -DM Three-phase /R R = Victaulic coupling S = Screwed connection

WILO SE 11/2013

5.3 Technical data When ordering spare parts be sure to state all the information given on the pump and motor type plates. Fluids If water/glycol mixtures are used (or fluids with a viscosity other than that of pure water), an increase in power consumption of the pump is to be taken into account. Only use mixtures with corrosion inhibitors. The respective manufacturer's instructions are to be observed. • The fluid must be sediment-free. • Wilo's approval must be obtained for use of other media. • Mixtures with a proportion of glycol of > 10 % influence the Δp-v pump curve and the flow calculation. NOTE Always read and follow the material safety data sheet for the fluid being pumped! 5.4 Scope of delivery • Pump BAC • Installation and operating instructions 5.5 Accessories Accessories must be ordered separately: • Suction kits • Isolating valves • Non-return valves • Foot valve for strainer Property Value Remarks Pipe connections BAC 40.../S: Nominal diameter G2/G 1½ or Victaulic connec- tions BAC 40.../R: 60.3/48.3 mm BAC 70.../R: 76.1/76.1 mm Permissible min./max. fluid temperature -15 °C to +60 °C Ambient temperature max. +40 °C Permissible humidity < 95 %, non-condensing Max. admissible operating pressure 6,5 bar Max. admissible suction pressure 4,0 bar Suction Head depends on NPSH value of the pump Approved fluids Cooling/cold water Water/glycol mixture up to 40 % vol. Heating water according to VDI 2035 Other fluids on request Heating water up to +60 °C Permissible chloride content of fluid Cl <150 mg/l Viscosity of fluid 1 cSt bis 50 cSt pH values of fluid 6 bis 8 Permissible solid grain size in medium Ø max. 0,5 mm Motor efficiency IE2 for 3-phase motor according to IEC 60034-30 Protection class IP 55 Insulation class F Electrical connection Electrical voltage and frequency see rating plate of motor Voltage tolerance ±10% Section of the power cable (cable with 4 wires) 0,75/1,1 kW: 1,5 mm2 - 2,5 mm2 1,5/2,2/3/4 kW: 2,5 mm2 - 4,0 mm2 Acoustic pressure level 68 dB(A) Value at 50 Hz

Installation and operating instructions Wilo-BAC

23 • Bladder or galvanised tanks • Vibrationless sleeves • Motor protection circuit-breaker • Dry-running protection • Device for ON/OFF control and dry-running protection • Victaulic coupling typ 6 Description and function 6.1 Product description Legend, see (Fig. 1/2): 1 Foot valve for strainer (max. passage cross-section of 1 mm) 2 Pump suction valve 3 Pump discharge valve 4 Non-return valve 5 Filling plug 6 Drain plug 7 Pipe support 8 Strainer 9 Storage tank 10 Town water supply 11 Motor protection relay for three-phase motor HA Suction head HC Discharge head 6.2 Design of product BAC pumps are non self-priming, single-stage centrifugal pumps in a horizontal monobloc construction. The suction port is arranged in an axial orientation and the pressure port is arranged in a radial orienta- tion. They are equipped with an air cooled motor. The pump housing is made of composite, and depending on the power, the pumps are fitted with “Victaulic” and/or threaded unions. The shaft is sealed with a mechanical seal that does not need any maintenance.. 7 Installation and electrical connection Safety DANGER! Danger of death! Incorrect installation and improper electrical connections can result in a risk of fatal injury. • Have the electrical connections established by approved electri- cians only, in compliance with the applicable regulations. • Accident prevention regulations must be observed! CAUTION! Risk of property damage! Danger of damage due to incorrect handling. • Have the pump installed by qualified personnel only. 7.1 Commissioning • Unpack the pump and dispose of the packaging in an environmen- tally-responsible manner. 7.2 Installation CAUTION! Risk of damage to the pump! Dirt can cause pump failure. • The pump should only be installed after completion of all welding and soldering work and, if necessary, flushing of the pipe system. WARNING! Risk of burns to the pump when body parts come into contact with the pump! Depending on the pump or system operating conditions (fluid tem- perature), the entire pump can become very hot. • The pump must be positioned in a way that nobody will come into contact with the hot pump surfaces during operation.

WILO SE 11/2013

WARNING! Risk of fall! • The pump must be firmly fixed on the ground. CAUTION! Risk of remaining parts in the pump! • Remove all cover plugs from the pump housing before installation. • The pump must be installed in an easily accessible position to facili- tate inspection or replacement. • The pumps must be protected from the weather and installed in a frost/dust-free, well-ventilated atmosphere which is not potentially explosive. The pump must not be installed outdoors. • The air access to the motor fan must be free. There must be a mini- mum distance of 0.3 m between the pump and the wall. • Pumpe vorzugsweise auf einer glatten Zementoberfläche aufstellen. • The pump must be fixed with at least two studs of Ø M8 or Ø M10, depending on the pump. • The motor is provided with a condensate drain (under the motor). The drain is plugged in the factory to guarantee the IP55 protection. For use in air-conditioning or cooling applications, this plug must be removed to allow the evacuation of the condensate water. NOTE If the caps are removed, protection class IP 55 is no longer ensured! 7.3 Pipe connection General NOTE A settling section must be provided before and after the pump, in the form of a straight pipe. The length of this settling section should be at least 5 x DN of the pump flange (Fig. 4). This measure serves to avoid flow cavitation. Connection variants There are two standard variants: 1 Pump in suction mode (Fig. 1) 2 Pump in pressure mode (Fig. 2), from storage tank (Fig. 2, Item 9) or municipal water supply (Fig. 2, Item 10) with dry-running pro- tection system. CAUTION! Risk of possible damage of the pump! Tightening of screws or bolts must not exceed 10daNm. Use of impact wrench is prohibited. • The circulation direction of the fluid is indicated on the pump housing. • The pipes and pump must be free of mechanical stress when installed. • The pump must be installed in a way that it does not carry the weight of the pipework. NOTE It is recommended that isolation valves are installed on the suction and pressure side of the pump. • Use expansion rubbers to reduce noise and vibrations of the pump. • Provide a suction pipe with a nominal cross-section which is at least as large as the pump connection. • A non-return valve can be fitted on the pressure pipe to protect the pump against fluid hammer. • For a direct connection to a public drinking water system, the suction pipe must also have a non-return valve and a guard valve. Fig. 4: Settling section before and after the pump r 5 x DN d s r  2,5 · (d · 2s)

Installation and operating instructions Wilo-BAC

25 • For an indirect connection via a tank, the suction pipe must have a strainer to keep any impurities out of the pump, as well as a non- return valve. • If the pump is operated in suction mode (Fig. 1): immerse the strainer into the fluid (at least 200 mm) and, if necessary, put weights on the flexible hose. Limit the length of the suction pipe and avoid all features that cause losses of head (tapers, bends, etc.). No air must get into this pipe which rises upwards (by 2%). CAUTION Risk of leak! The alignment of the pipes and the pump ports is important. • If a “Victaulic” pipe union is used, an angular deviation of max. 3° of 2’’ pumps is allowed, and an angular deviation of max. 2° of 3’’ od pumps is allowed • If screwed unions are used, the alignment of the pump ports must not have any deviation and the tightening must not exceed 4daNm. • Carefully seal the pipes with suitable products. Nominal connection diameter (DN) of the pump: 7.4 Electrical connection Safety DANGER! Risk of fatal injury! A fatal shock may occur if the electrical connection is not made correctly. • Only allow the electrical connection to be made by an electrician approved by the local electricity supplier and in accordance with the local regulations in force. • Check to ensure all connections (including potential-free contacts) are voltage-free. • For a safe installation and operation, a proper grounding of the pump to the grounding terminals of the power supply is required. • Observe the installation and operating instructions for the acces- sories! • Make sure that the operating current, the voltage and the frequency comply with the rating plate data of the motor. • The pump must be connected to the power supply by a solid cable that is equipped with a grounded plug-connection or a main power switch. • Three-phase motors must be connected to an approved safety switch. The nominal current must correspond to the electrical data on the rating plate of the motor. • The supply cable must be laid in a way that it never touches the pipe- work and/or the pump and motor housing. • The pump/installation must be grounded in compliance with local regulations. A ground fault interrupter can be used as an extra protec- tion. • The connection to the network must be in accordance with the con- nection plan. Port type Port ND (tapped): Suction Discharge Victaulic ≤ 2,2 kW 2" (Ø 60,3 mm) 11/2" (Ø48,3 mm) Victaulic > 2,2 kW 3" od (Ø 76,1 mm) 3" od (Ø 76,1 mm) Threaded ≤ 2,2 kW 2" (50-60 mm) 11/2" (40-49 mm)

WILO SE 11/2013

7.5 Operation with Wilo control devices The power of the pumps can be continuously controlled in combina- tion with a control device (Wilo-VR-System or Wilo-CC-System). This allows an optimised pump output in a given installation and is also economically efficient. 7.6 Operation with frequency converter (of other manufacturers) Motors from Wilo/Salmson can generally be operated with external frequency converters if these frequency converters comply with the demands specified in the application guideline IEC /TS 60034-17 and IEC/TS 60034-25. The impulse voltage of the converter (without filter) must be below the limiting curve shown in (Fig. 5). This concerns the voltage at the motor terminals. This is not only determined by the frequency converter, but also e.g. by the motor cable used (type, cross-section, screening, length, ... • Strictly follow the instructions provided by the manufacturer of the frequency converter. The rise times and peak voltages for different cable lengths are specified in the corresponding installation and oper- ating instructions. • Take to following points into account: • use suitable cables with a sufficient cross-section (max. 5% voltage loss) • connect the correct screening according to the manufacturer's rec- ommendation of the frequency converter • pass data lines (e.g. PTC-evaluation) separately from the mains cable • possibly use of a sinusoidal filter (LC) in agreement with the manu- facturer of the converter Operation is possible from 12.5 Hz up to 50 Hz. In case of low fre- quency operation, it is recommended to start with 50 Hz and then turn down to the selected value. 8 Commissioning 8.1 System filling and venting CAUTION! Possible damage of the pump! Dry running destroys the mechanical seal • Make sure that the pump does not run dry. • The system must be filled before starting the pump. If a venting procedure is necessary (according to chapter 8.1.1 “Vent- ing procedure – pump in pressure mode” on page 27 and chapter 8.1.2 “Venting procedure – pump in suction mode” on page 27), observe the following instructions. DANGER! Risk of burns or freezing to the pump when body parts come into contact with the pump! Depending on the pump or system operating conditions (fluid tem- perature), the entire pump can become very hot or very cold. • Keep a safe distance during operation! • In the case of high water temperatures and system pressures, allow the pump to cool down before all work. • Always wear protective clothing, protective gloves and protective goggles when working. WARNING! Danger due to extremely hot or extremely cold pressu- rised fluid! Depending on the temperature of the fluid and the system pres- sure, when the vent screw is opened completely, extremely hot or extremely cold fluid in liquid or vapour form may escape or shoot out at high pressure. • Always exercise caution when opening the venting plug. Fig. 5: Limit curve for the permitted impulse voltage Upk (including voltage reflection and damping), measured between the terminals of two branches, depending on the rise time tr 0 0,4 0,8 1,2 1,6 2 2,4 0 0,2 0,4 0,6 0,8 1 1,2 tr [µs] Upk [kV] 400V (IEC 60034-17) 500V (IEC 60034-25, Level A) 690V (IEC 60034-25, Level B) 1,56 kV 1,35 kV 2,15 kV

Installation and operating instructions Wilo-BAC

27 WARNING! Risk of injury! If the pump/system is installed improperly, liquid may be ejected during commissioning. Individual components may also become loose. • Keep a safe distance from the pump during commissioning. • Wear protective clothing, protective gloves and protective gog- gles. 8.1.1 Venting procedure – pump in pressure mode See (Fig. 2): • Close the discharge valve (Fig. 2, Item 3). • Unscrew the filling plug (Fig. 2, Item 5) (on the upper part of hydrau- lics). • Open the suction valve slowly (Fig. 2, Item 2) and completely fill the pump. • Only screw the filling plug back in after water has flown out and all air has been eliminated. • Open the suction valve completely (Fig. 2, Item 2). • Check if the direction of rotation is correct according to the arrow on the pump housing by briefly starting the pump. If the direction of rotation is not correct, invert 2 phases on the motor terminal board. • Open the discharge valve (Fig. 2, Item 3). 8.1.2 Venting procedure – pump in suction mode Two cases are possible. First case, see (Fig. 1): • Open the discharge valve (Fig. 1, Item 3). • Open the suction valve (Fig. 1, Item 2). • Unscrew the filling plug (Fig. 1, Item 5) (on the upper part of hydrau- lics). • Put a funnel into the port and slowly and completely fill the pump and the suction pipe. • Filling is complete when water has flown out and all air has been elim- inated. Screw the plug back in. • Check if the direction of rotation is correct according to the arrow on the pump housing by briefly starting the pump. If the direction of rotation is not correct, invert 2 phases on the motor terminal board. Second case, see (Fig. 1/3): • To make the filling process easier, install a vertical pipe (minimum length 25 cm), fitted with a stopcock and a funnel, on the pump suc- tion pipe (see Fig. 3) • Open the discharge valve (Fig. 1, Item 3) • Open the suction valve (Fig. 1, Item 2). • Unscrew the filling plug (Fig. 1, Item 5) (on the upper part of the hydraulics). • Fill the pump and the suction pipe completely until water flows out. • Close the stopcock (which can be left in place), remove the pipe, and screw the filling plug back in. CAUTION! Risk of wrong evacuation of air! A check is always required in both cases mentioned above. After screwing in again of the filling plug, it is necessary to: • Start the motor by a brief impulse. • Unscrew again the filling plug and complete the filling until the final water level is reached in the pump. • If necessary, repeat this operation. • Check if the direction of rotation is correct according to the arrow on the pump housing by briefly starting the pump. If the direction of rotation is not correct, invert 2 phases on the motor terminal board.

WILO SE 11/2013

NOTE To prevent the pump from accidentally priming while the full water level has not been reached, we recommend protecting it with a suit- able device (dry running protection or float switch). 8.2 Commissioning WARNING! Risk of injury! • Installation must be designed in order that no one could be hurt in case of fluid leakage (mechanical seal failure…). CAUTION! Possible damage of the pump! The pump must not be operated at zero flow (closed discharge valve) for more than ten minutes. • We recommend establishing a minimum flow of about 10 % of the rated capacity of the pump, to avoid the formation of a gas pocket. • Use a pressure gauge to check the stability of the discharge pressure; if it is unstable, vent the pump again or perform the filling operation. CAUTION! Risk of motor overload! • Check that the input current does not exceed the value marked on the motor rating plate. 9 Maintenance/Service Maintenance and repairs may only be carried out by qualified experts! It is recommended to have the pump serviced and checked by Wilo- Customer Service. DANGER! Risk of fatal injury! There is a mortal danger through shock when working on electrical equipment. • Work on electrical equipment may only be done by electricians approved by the local electricity supplier. • Before working on electrical equipment, switch it off and prevent it from being switched on again. • Any damage to the connecting cable should always be rectified by a qualified electrician only. • Follow the installation and operating instructions for the pump, level control device and other accessories. • After maintenance, all safety devices such as terminal box cover that were removed must be reinstalled! DANGER! Risk of fatal injury! The pump itself and the parts of pump can be extremely heavy. Falling parts pose a risk of cuts, crush injuries, bruises or impacts, which may lead to death. • Always use suitable lifting equipment and secure parts against fall- ing. • Never stand underneath a suspended load. • Make sure the pump is securely positioned and is stable during storage and transport as well as prior to all installation and other assembly work. DANGER! Risk of burns or freezing to the pump when body parts come into contact with the pump! Depending on the pump or system operating conditions (fluid tem- perature), the entire pump can become very hot or very cold. • Keep a safe distance during operation! • In the case of high water temperatures and system pressures, allow the pump to cool down before all work. • Always wear protective clothing, protective gloves and protective goggles when working. • No special servicing while the pump is in operation.

Installation and operating instructions Wilo-BAC

29 • Always keep the pump perfectly clean. • To avoid any blocking of the shaft and the hydraulic system in frosty periods, empty the pump by removing the drain plug (on the lower part of hydraulic) and the filling plug. Screw the 2 plugs back in with- out tightening them. • If there is no risk of frost, do not drain the pump. 10 Faults, causes and remedies Only qualified personnel is allowed to repair. Observe the safety instructions as described in chapter 9 “Maintenance/Service” on page 28. • If a fault cannot be remedied, contact a specialist, the after-sales department or the nearest sales office. Fault Cause Remedy The Pump runs but no delivery Pump obstructed by the internal parts Check and clean the pump Suction pipe obstructed Check and clean the pipe Water level/suction pressure is insuf- ficient Fill the storage tank, vent the pump The suction pressure is too low; this is generally accompanied by cavitation noise Loss of head on suction or suction height too great (check the NPSH of the pump installed) Wrong direction of rotation Invert two phase wires on the motor ter- minal block or circuit-breaker The supply voltage to the motor is too low Check the voltage and the wire sections of the cable The pump is vibrating The pump is installed loosely on its foundation Check and tighten completely the nuts of the stud bolts Foreign bodies inside the pump Have the pump dismantled and clean it The pump runs with difficulty, dam- aged bearing Have the pump repaired by the after- sales Electrical connection of the pump is wrong Check and correct the pump connection The pump overheats Voltage supply is too low Check the voltage on the terminals of the motor; it should be within ±10 % of the rated voltage Particles obstructing the pump Have the pump dismantled and clean it Ambient temperature above 40 °C The motor is designed to operate at an ambient temperature of not more than +40 °C, if necessary, install a cooling sys- tem The pump fails to run No power Check the power supply, fuses, cables Turbine is blocked Clean the pump Motor protection has triggered Check and adjust the motor protection No sufficient flow The motor speed is not high enough (caused by particles or too low volt- age) Clean the pump, check the electrical sup- ply The motor is defective Call the after-sales service, replace the motor Water level/suction pressure is insuf- ficient Fill the storage tank, vent the pump Wrong direction of rotation Invert two phases wires on the motor ter- minal block or circuit-breaker Wear of the internal parts Have the pump repaired by the after- sales service

WILO SE 11/2013

11 Spare parts Spare parts can be ordered from your local specialist and/or via Wilo customer service. To avoid queries and incorrect orders, all details on the rating plate should be submitted for each order. CAUTION! Risk of property damage! Trouble-free pump operation can only be guaranteed when origi- nal spare parts are used. • Only use original Wilo spare parts. • Each component is identified in the table below. Information to be provided when ordering spare parts: • Spare part number • Name/description of the spare part • All data on the pump and motor rating plate NOTE: List of genuine spare parts: see Wilo spare parts documentation. Spare parts catalogue is available at: www.wilo.com. 12 Disposal Proper disposal and recycling of this product prevents damage to the environment and risks to personal health. Proper disposal requires the drainage and cleaning and the disman- tling of the pump unit. Lubricants must be collected. The pump components are to be sepa- rated according to material (metal, plastic, electronics). 1. Use public or private disposal organisations when disposing of all or part of the product. 2. For more information on proper disposal, please contact your local council or waste disposal office or the supplier from whom you obtained the product. Subject to change without prior notice. The motor protection triggers The setting of the thermal relay is too low Check the current with an amperemeter, or set to the current rating marked on the motor data plate The voltage is too low Check that the conductor cross-sections of the power cable are adequate One phase is open-circuit Check it and, if necessary, replace the power cable Motor protection switch is defective Replace the motor protection switch The motor is defective Call the after-sales service, replace the motor Flow rate too high because of too low system resistance Reduce pump on outlet side The flow is irregular The suction height (HA) is exceeded Reread the installation conditions and recommendations in this instruction manual The diameter of the suction pipe is smaller than that of the pump The suction pipe must have the same diameter as the pump suction port The strainer and suction pipe are par- tially obstructed Remove the filter and clean it Fault Cause Remedy

D EG – Konformitätserklärung

GB EC – Declaration of conformity F Déclaration de conformité CE (gemäß 2006/42/EG Anhang II,1A und 2004/108/EG Anhang IV,2, according 2006/42/EC annex II,1A and 2004/108/EC annex IV,2, conforme 2006/42/CE appendice II,1A et 2004/108/CE l’annexe IV,2) Hiermit erklären wir, dass die Pumpenbauarten der Baureihe: BAC Herewith, we declare that the pump types of the series: Par le présent, nous déclarons que les types de pompes de la série : (Die Seriennummer ist auf dem Typenschild des Produktes nach Punkten b) & c) von §1.7.4.2 und §1.7.3 des Anhanges I der Maschinenrichtlinie angegeben. / The serial number is marked on the product site plate according to points b) & c) of §1.7.4.2 and §1.7.3 of the annex I of the Machinery directive 2006/42/EC. / Le numéro de série est inscrit sur la plaque signalétique du produit en accord avec les points b) & c) du §1.7.4.2 et du §1.7.3 de l’annexe I de la Directive Machines 2006/42/CE) in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entsprechen: in their delivered state comply with the following relevant provisions: sont conformes aux dispositions suivantes dont ils relèvent: EG-Maschinenrichtlinie 2006/42/EG EC-Machinery directive Directive CE relative aux machines Die Schutzziele der Niederspannungsrichtlinie 2006/95/EG werden gemäß Anhang I, Nr. 1.5.1 der 2006/42/EG Maschinenrichtlinie eingehalten. / The protection objectives of the low-voltage directive 2006/95/EC are realized according annex I, No. 1.5.1 of the EC-Machinery directive 2006/42/EC. / Les objectifs de protection de sécurité de la directive basse-tension 2006/95/CE sont respectés conformément à l’annexe I, no1.5.1 de la directive CE relatives aux machines 2006/42/CE. Elektromagnetische Verträglichkeit - Richtlinie 2004/108/EG Electromagnetic compatibility - directive Directive compatibilité électromagnétique Richtlinie energieverbrauchsrelevanter Produkte 2009/125/EG Energy-related products - directive Directive des produits liés à l’énergie Die verwendeten 50Hz Induktionselektromotoren - Drehstrom, Käfigläufer, einstufig - entsprechen den Ökodesign - Anforderungen der Verordnung 640/2009 und der Verordnung 547/2012 für Wasserpumpen. This applies according to eco-design requirements of the regulation 640/2009 to the versions with an induction electric motor, squirrel cage, three-phase, single speed, running at 50 Hz and of the regulation 547/2012 for water pumps. Qui s’applique suivant les exigences d’éco-conception du règlement 640/2009 aux versions comportant un moteur électrique à induction à cage d’écureuil, triphasé, mono-vitesse, fonctionnant à 50 Hz et, du règlement 547/2012 pour les pompes à eau, und entsprechender nationaler Gesetzgebung, and with the relevant national legislation, et aux législations nationales les transposant, angewendete harmonisierte Normen, insbesondere: EN 809+A1 EN ISO 12100 EN 60034-1 EN 60204-1 as well as following relevant harmonized standards: ainsi qu’aux normes européennes harmonisées suivantes : Bevollmächtigter für die Zusammenstellung der technischen Unterlagen ist: Division Pumps and Systems Quality Manager – PBU Multistage & Domestic Pompes Salmson 80 Bd de l’Industrie - BP0527 F-53005 Laval Cedex Authorized representative for the completion of the technical documentation: Personne autorisée à constituer le dossier technique est : Dortmund, 15. Januar 2013 Holger HERCHENHEIN Group Quality Manager WILO SE Nortkirchenstraße 100 44263 Dortmund Germany Document: 2117789.2 CE-AS-Sh. Nr. 4138791

EG-verklaring van overeenstemming

Dichiarazione di conformità CE Declaración de conformidad CE Hiermede verklaren wij dat dit aggregaat in de geleverde uitvoering voldoet aan de volgende bepalingen: Con la presente si dichiara che i presenti prodotti sono conformi alle seguenti disposizioni e direttive rilevanti: Por la presente declaramos la conformidad del producto en su estado de suministro con las disposiciones pertinentes siguientes: EG-richtlijnen betreffende machines 2006/42/EG Direttiva macchine 2006/42/EG Directiva sobre máquinas 2006/42/EG De veiligheidsdoelstellingen van de laagspanningsrichtlijn worden overeenkomstig bijlage I, nr. 1.5.1 van de machinerichtlijn 2006/42/EG aangehouden. Gli obiettivi di protezione della direttiva macchine vengono rispettati secondo allegato I, n. 1.5.1 dalla direttiva macchine 2006/42/CE. Se cumplen los objetivos en materia de seguridad establecidos en la Directiva de Baja tensión según lo especificado en el Anexo I, punto 1.5.1 de la Directiva de Máquinas 2006/42/CE. Elektromagnetische compatibiliteit 2004/108/EG Compatibilità elettromagnetica 2004/108/EG Directiva sobre compatibilidad electromagnética 2004/108/EG Richtlijn voor energieverbruiksrelevante producten 2009/125/EG Direttiva relativa ai prodotti connessi all'energia 2009/125/CE Directiva 2009/125/CE relativa a los productos relacionados con el consumo de energía De gebruikte 50 Hz inductie-elektromotoren – draaistroom, kooianker, ééntraps – conform de ecodesign-vereisten van de verordening 640/2009. I motori elettrici a induzione utilizzati da 50 Hz – corrente trifase, motore a gabbia di scoiattolo, monostadio – soddisfano i requisiti di progettazione ecocompatibile del regolamento 640/2009. Los motores eléctricos de inducción de 50 Hz utilizados (de corriente trifásica, rotores en jaula deardilla, motores de una etapa) cumplen los requisitos relativos al ecodiseño establecidos en el Reglamento 640/2009. Conform de ecodesign-vereisten van de verordening 547/2012 voor waterpompen. Ai sensi dei requisiti di progettazione ecocompatibile del regolamento 547/2012 per le pompe per acqua. De conformidad con los requisitos relativos al ecodiseño del Reglamento 547/2012 para bombas hidráulicas. gebruikte geharmoniseerde normen, in het bijzonder: zie vorige pagina norme armonizzate applicate, in particolare: vedi pagina precedente normas armonizadas adoptadas, especialmente: véase página anterior PT SV NO Declaração de Conformidade CE CE- försäkran EU-Overensstemmelseserklæring Pela presente, declaramos que esta unidade no seu estado original, está conforme os seguintes requisitos: Härmed förklarar vi att denna maskin i levererat utförande motsvarar följande tillämpliga bestämmelser: Vi erklærer hermed at denne enheten i utførelse som levert er i overensstemmelse med følgende relevante bestemmelser: Directivas CEE relativas a máquinas 2006/42/EG EG–Maskindirektiv 2006/42/EG EG–Maskindirektiv 2006/42/EG Os objectivos de protecção da directiva de baixa tensão são cumpridos de acordo com o anexo I, nº 1.5.1 da directiva de máquinas 2006/42/CE. Produkten uppfyller säkerhetsmålen i lågspänningsdirektivet enligt bilaga I, nr 1.5.1 i maskindirektiv 2006/42/EG. Lavspenningsdirektivets vernemål overholdes i samsvar med vedlegg I, nr. 1.5.1 i maskindirektivet 2006/42/EF. Compatibilidade electromagnética 2004/108/EG EG–Elektromagnetisk kompatibilitet – riktlinje 2004/108/EG EG–EMV–Elektromagnetisk kompatibilitet 2004/108/EG Directiva relativa à criação de um quadro para definir os requisitos de concepção ecológica dos produtos relacionados com o consumo de energia 2009/125/CE Direktivet om energirelaterade produkter 2009/125/EG Direktiv energirelaterte produkter 2009/125/EF Os motores eléctricos de indução de 50 Hz utilizados – corrente trifásica, com rotor em curto-circuito, monocelular – cumprem os requisitos de concepção ecológica do Regulamento 640/2009. De använda elektriska induktionsmotorerna på 50 Hz – trefas, kortslutningsmotor, enstegs – motsvarar kraven på ekodesign för elektriska motorer i förordning 640/2009. De 50 Hz induksjonsmotorene som finner anvendelse – trefasevekselstrøms kortslutningsmotor, ettrinns – samsvarer med kravene til økodesign i forordning 640/2009. Cumprem os requisitos de concepção ecológica do Regulamento 547/2012 para as bombas de água. Motsvarande ekodesignkraven i förordning 547/2012 för vattenpumpar. I samsvar med kravene til økodesign i forordning 547/2012 for vannpumper. normas harmonizadas aplicadas, especialmente: ver página anterior tillämpade harmoniserade normer, i synnerhet: se föregående sida anvendte harmoniserte standarder, særlig: se forrige side FI DA HU CE-standardinmukaisuusseloste EF-overensstemmelseserklæring EK-megfelelségi nyilatkozat Ilmoitamme täten, että tämä laite vastaa seuraavia asiaankuuluvia määräyksiä: Vi erklærer hermed, at denne enhed ved levering overholder følgende relevante bestemmelser: Ezennel kijelentjük, hogy az berendezés megfelel az alábbi irányelveknek: EU–konedirektiivit: 2006/42/EG EU–maskindirektiver 2006/42/EG Gépek irányelv: 2006/42/EK Pienjännitedirektiivin suojatavoitteita noudatetaan konedirektiivin 2006/42/EY liitteen I, nro 1.5.1 mukaisesti. Lavspændingsdirektivets mål om beskyttelse overholdes i henhold til bilag I, nr. 1.5.1 i maskindirektivet 2006/42/EF. A kisfeszültség irányelv védelmi elírásait a 2006/42/EK gépekre vonatkozó irányelv I. függelékének 1.5.1. sz. pontja szerint teljesíti. Sähkömagneettinen soveltuvuus 2004/108/EG Elektromagnetisk kompatibilitet: 2004/108/EG Elektromágneses összeférhetség irányelv: 2004/108/EK Energiaan liittyviä tuotteita koskeva direktiivi 2009/125/EY Direktiv 2009/125/EF om energirelaterede produkter Energiával kapcsolatos termékekrl szóló irányelv: 2009/125/EK Käytettävät 50 Hz:n induktio-sähkömoottorit (vaihevirta- ja oikosulkumoottori, yksivaiheinen moottori) vastaavat asetuksen 640/2009 ekologista suunnittelua koskevia vaatimuksia. De anvendte 50 Hz induktionselektromotorer - trefasestrøm, kortslutningsmotor, et-trins - opfylder kravene til miljøvenligt design i forordning 640/2009. A használt 50 Hz-es indukciós villanymotorok – háromfázisú, kalickás forgórész, egyfokozatú – megfelelnek a 640/2009 rendelet környezetbarát tervezésre vonatkozó követelményeinek. Asetuksessa 547/2012 esitettyjä vesipumppujen ekologista suunnittelua koskevia vaatimuksia vastaava. I overensstemmelse med kravene til miljøvenligt design i forordning 547/2012 for vandpumper. A vízszivattyúkról szóló 547/2012 rendelet környezetbarát tervezésre vonatkozó követelményeinek megfelelen. käytetyt yhteensovitetut standardit, erityisesti: katso edellinen sivu. anvendte harmoniserede standarder, særligt: se forrige side alkalmazott harmonizált szabványoknak, különösen: lásd az elz oldalt CS PL RU Prohlášení o shod ES Deklaracja Zgodnoci WE           Prohlašujeme tímto, že tento agregát vdodaném provedení odpovídá následujícím píslušným ustanovením: Niniejszym deklarujemy z pe n odpowiedzialno ci , e dostarczony wyrób jest zgodny z nast puj cymi dokumentami:   ,  !" #$#  # &' *  + $! : Smrnice ES pro strojní zaízení 2006/42/ES dyrektyw maszynow WE 2006/42/WE    EC     2006/42/EG Cíle týkající se bezpe;nosti stanovené ve sm!  $ * ? *$>+, &++ # *$>+ I, @ 1.5.1 $!  J J 2006/42/QG. Smrnice o elektromagnetické kompatibilit 2004/108/ES dyrektyw dot. kompatybilnoci elektromagnetycznej 2004/108/WE      !" 2004/108/EG Smrnice pro výrobky spojené se spotebou energie 2009/125/ES Dyrektywa w sprawie ekoprojektu dla produktów zwizanych z energi 2009/125/WE.      # , $   %  &  2009/125/( Použité 50Hz tífázové induk;ní motory, s klecovým rotorem, jednostupTové – vyhovují požadavkUm na ekodesign dle naízení 640/2009 Stosowane elektryczne silniki indukcyjne 50 Hz – trójfazowe, wirniki klatkowe, jed- nostopniowe spe niaj wymogi rozporz dzenia 640/2009 dotycz ce ekoprojektu X*?! Z$! [$# 50 \] – $Z^# , $! *! + $&  [" požadavkUm na ekodesign dle naízení 640/2009. nostopniowe – spe niaj wymogi rozporz dzenia 640/2009 dotycz ce ekoprojektu. $!, *! – + $&  [" Vyhovuje požadavkUm na ekodesign dle naízení 547/2012 pro vodní ;erpadla. Spe niaj wymogi rozporz dzenia 547/2012 dotycz cego ekoprojektu dla pomp wodnych. _ $&  [" *$* 547/2012  !Z . použité harmoniza;ní normy, zejména: viz pedchozí strana stosowanymi normami zharmonizowanymi, a w szczególno ci: patrz poprzednia strona X*?! #! $!  $!,   : . *$!+ $] EL TR RO )*+37; 7<==>?@37;B J;B QQ CE Uygunluk Teyid Belgesi EC-Declara[ie de conformitate `{|}~€‚ ƒ„… „ †‡ˆƒ~ ‰€„ƒ Š’ ‰€„Œ „{~ ‰„ŽŠ„‰Š{ †‰‡ŽŠ{ …‰~†…‚‘ „… ‰ƒ|€’‚ …‰„Ž“‚… : Bu cihaz”n teslim edildi•i –ekliyle a–a•”daki standartlara uygun oldu•unu teyid ederiz: Prin prezenta declar—m c— acest produs a–a cum este livrat, corespunde cu urm—toarele prevederi aplicabile: \];^_`B Ex ^{| =;}|~*=|J| 2006/42/Ex AB-Makina Standartlar 2006/42/EG Directiva CE pentru ma€ini 2006/42/EG ˜… ‰†‰…„ŒŠ‚… †‡Š„‰Š‘‰ „{ {™‘‰ š‰{|Œ „ŽŠ{ „{‡›~„‰… Š›œ~‰ ‚ „ †‰‡Ž‡„{‰ I, ‰‡. 1.5.1 „{ {™‘‰ Šš‚„…Ž ‚ „‰ {š‰~Œ‰„‰ 2006/42/EG. Alçak gerilim yönergesinin koruma hedefleri, 2006/42/AT makine yönergesi Ek I, no. 1.5.1'e uygundur. Sunt respectate obiectivele de protec ie din directiva privind joasa tensiune conform Anexei I, Nr. 1.5.1 din directiva privind ma–inile 2006/42/CE. +`‚J?ƒ=|^~;J{‚* 7<=„|J>J;J| Ex-2004/108/Ex Elektromanyetik Uyumluluk 2004/108/EG Compatibilitatea electromagnetic… – directiva 2004/108/EG Q=`~| =` J;~ `~ˆ?^`{| †?ƒ‡>~J| 2009/125/Ex Enerji ile ilgili ürünlerin çevreye duyarl tasarmna ili€kin yönetmelik 2009/125/AT Directiv… privind produsele cu impact energetic 2009/125/CE ˜… š‡{Š…†…›‚~… ‚†‰™™…‘ {|‚„‡…~{„Œ‡‚ 50 Hz – „‡…œ‰Š…‘, ‡¡‰ |¢›, ~¢Ž’…… – ‰~„‰†‡‘~~„‰… Š„… ‰†‰…„ŒŠ‚… …|™…› Šš‚…‰Š› „€ ‰~~…Ё› 640/2009. Kullan”lan 50 Hz indüksiyon elektromotorlar” – trifaze ak”m, sincap kafes motor, tek kademeli – 640/2009 Düzenlemesinde ekolojik tasar”mla ilgili gerekliliklere uygundur. Electromotoarele cu induc ie, de 50 Hz, utilizate – curent alternativ, motor în scurtcircuit, cu o treapt— – sunt în conformitate cu parametrii ecologici cuprin–i în Ordonan a 640/2009. £›œ~‰ ‚ „… ‰†‰…„ŒŠ‚… …|™…› Šš‚…‰Š› „€ ‰~~…Ё› 547/2012 ™…‰ €‡‰~„|‘‚. Su pompalar” ile ilgili 547/2012 Düzenlemesinde ekolojik tasar”ma ili–kin gerekliliklere uygun. În conformitate cu parametrii ecologici cuprin–i în Ordonan a 547/2012 pentru pompe de ap—. ¤~‰‡~…Ё¡~‰ š‡{Š…†…›‚~‰ †‡ƒ„€†‰, ……‰‘„‚‡‰: ¥|¡†‚ †‡{™›‚~{ Š‚|‘‰ k”smen kullan”lan standartlar için: bkz. bir önceki sayfa standarde armonizate aplicate, îndeosebi: vezi pagina precedent— ET LV LT EÜ vastavusdeklaratsioon EC - atbilst‰bas deklarŠcija EB atitikties deklaracija Käesolevaga tõendame, et see toode vastab järgmistele asjakohastele direktiividele: Ar šo m¦s apliecin§m, ka šis izstr§d§jums atbilst sekojošiem noteikumiem: Šiuo pažymima, kad šis gaminys atitinka šias normas ir direktyvas: Masinadirektiiv 2006/42/EÜ Maš‰nu direkt‰va 2006/42/EK Mašin‹ direktyv 2006/42/EB Madalpingedirektiivi kaitse-eesmärgid on täidetud vastavalt masinate direktiivi 2006/42/EÜ I lisa punktile 1.5.1. Zemsprieguma direktªvas drošªbas m¦r«i tiek iev¦roti atbilstoši Mašªnu direktªvas 2006/42/EK Pielikumam I, Nr. 1.5.1. Laikomasi Žemos ­tampos direktyvos keliam® saugos reikalavim® pagal Mašin® direktyvos 2006/42/EB I priedo 1.5.1 punkt . Elektromagnetilise ühilduvuse direktiiv 2004/108/EÜ ElektromagnŒtiskŠs savietojam‰bas direkt‰va 2004/108/EK Elektromagnetinio suderinamumo direktyv 2004/108/EB Energiamõjuga toodete direktiiv 2009/125/EÜ Direkt‰va 2009/125/EK par ar eneiju saist‰tiem produktiem Su energija susijusi‹ produkt‹ direktyva 2009/125/EB Kasutatud 50 Hz vahelduvvoolu elektrimootorid (vahelduvvool, lühisrootor, üheastmeline) vastavad määruses 640/2009 sätestatud ökodisaini nõuetele. Izmantotie 50 Hz indukcijas elektromotori – mai¯str§va, ªssl¦guma rotora motors, vienpak§pes – atbilst Regulas Nr. 640/2009 ekodizaina prasªb§m. Naudojami 50 Hz indukciniai elektriniai varikliai – trifaz°s ­tampos, su narveliniu rotoriumi, vienos pakopos – atitinka ekologinio projektavimo reikalavimus pagal Reglament 640/2009. Kooskõlas veepumpade määruses 547/2012 sätestatud ökodisaini nõuega. Atbilstoši Regulas Nr. 547/2012 ekodizaina prasªb§m ±denss±k¯iem. Atitinka ekologinio projektavimo reikalavimus pagal Reglament 547/2012 d°l vandens siurbli®. kohaldatud harmoneeritud standardid, eriti: vt eelmist lk piem¦roti harmoniz¦ti standarti, tai skait§: skatªt iepriekš¦jo lappusi pritaikytus vieningus standartus, o b±tent: žr. ankstesniame puslapyje SK SL BG ES vyhlásenie o zhode ES – izjava o skladnosti EŽ-  $  Týmto vyhlasujeme, že konštrukcie tejto konštruk;nej série v dodanom vyhotovení vyhovujú nasledujúcim príslušným ustanoveniam: Izjavljamo, da dobavljene vrste izvedbe te serije ustrezajo slede;im zadevnim dolo;ilom: ²$$,  *$' #$   : Stroje - smernica 2006/42/ES Direktiva o strojih 2006/42/ES   #   2006/42/EO Bezpe;nostné ciele smernice o nízkom napätí sú dodržiavané v zmysle prílohy I, ;. 1.5.1 smernice o strojových zariadeniach 2006/42/ES. Cilji Direktive o nizkonapetostni opremi so v skladu s prilogo I, št. 1.5.1 Direktive o strojih 2006/42/EG doseženi. ³    $*$&   *$>  ' '# ´$> I, @ 1.5.1  ²$  J 2006/42/E_. Elektromagnetická zhoda - smernica 2004/108/ES Direktiva o elektromagnetni združljivosti 2004/108/ES E      – #   2004/108/EŽ Smernica 2009/125/ES o energeticky významných výrobkoch Direktiva 2009/125/EG za okoljsko primerno zasnovo izdelkov, povezanih z energijo    $  # ,  $     &  2009/125/Ž Použité 50 Hz induk;né elektromotory – jednostupTové, na trojfázový striedavý prúd, s rotormi nakrátko – zodpovedajú požiadavkám na ekodizajn uvedeným v nariadení 640/2009. Uporabljeni 50 Hz indukcijski elektromotorji – trifazni tok, kletkasti rotor, enostopenjski – izpolnjujejo zahteve za okoljsko primerno zasnovo iz Uredbe 640/2009. X* ] $# 50 Hz – $^ , '$  #$, '* – #$    "  ¶# 640/2009. V súlade s požiadavkami na ekodizajn uvedenými v nariadení 547/2012 pre vodné ;erpadlá. izpolnjujejo zahteve za okoljsko primerno zasnovo iz Uredbe 547/2012 za vodne ;rpalke. _'#   "  ¶# 547/2012   **. používané harmonizované normy, najmä: pozri predchádzajúcu stranu uporabljeni harmonizirani standardi, predvsem: glejte prejšnjo stran ·$$ $: >. *$ $] MT HR SR Dikjarazzjoni ta’ konformità KE EZ izjava o sukladnosti EZ izjava o uskla“enosti B'dan il-mezz, niddikjaraw li l-prodotti tas-serje jissodisfaw id-dispo izzjonijiet relevanti li ¸ejjin: Ovim izjavljujemo da vrste konstrukcije serije u isporu;enoj izvedbi odgovaraju sljede¹im važe¹im propisima: Ovim izjavljujemo da vrste konstrukcije serije u isporu;enoj verziji odgovaraju slede¹im važe¹im propisima: Makkinarju - Direttiva 2006/42/KE EZ smjernica o strojevima 2006/42/EZ EZ direktiva za mašine 2006/42/EZ L-objettivi tas-sigurta tad-Direttiva dwar il-Vulta¸¸ Baxx huma konformi mal- Anness I, Nru 1.5.1 tad-Direttiva dwar il-Makkinarju 2006/42/KE. Ciljevi zaštite smjernice o niskom naponu ispunjeni su sukladno prilogu I, br. 1.5.1 smjernice o strojevima 2006/42/EZ. Ciljevi zaštite direktive za niski napon ispunjeni su u skladu sa prilogom I, br. 1.5.1 direktive za mašine 2006/42/EZ. Kompatibbiltà elettromanjetika - Direttiva 2004/108/KE Elektromagnetna kompatibilnost - smjernica 2004/108/EZ Elektromagnetna kompatibilnost - direktiva 2004/108/EZ Li j G id 2009/125/KE d d tti l t ti l ” t l •ij S j i i d l t l d t š j ij 2009/125/EZ Di kti i d l t l d t š j ij 2009/125/EZ Linja Gwida 2009/125/KE dwar prodotti relatati mal-u”u tal-ener•ija Smjernica za proizvode relevantne u pogledu potrošnje energije 2009/125/EZ Direktiva za proizvode relevantne u pogledu potrošnje energije 2009/125/EZ Il-muturi elettri»i b’induzzjoni ta’ 50 Hz u ati- tliet fa ijiet, squirrel-cage, singola - jissodisfaw ir-rekwi iti tal-ekodisinn tar-Regolament 640/2009. Korišteni 50 Hz-ni indukcijski elektromotori – trofazni, s kratko spojenim rotorom, jednostupanjski – odgovaraju zahtjevima za ekološki dizajn iz uredbe 640/2009. Koriš¹eni 50 Hz-ni indukcioni elektromotori – trofazni, s kratkospojenim rotorom, jednstepeni – odgovaraju zahtevima za ekološki dizajn iz uredbe 640/2009. b'mod partikolari: ara l-pa¸na ta' qabel primijenjene harmonizirane norme, posebno: vidjeti prethodnu stranicu primenjeni harmonizovani standardi, a posebno: vidi prethodnu stranu

Wilo – International (Subsidiaries)

Argentina WILO SALMSON ¼½¾¿ÀÁÂÃÁÄÅÆ½Æ¼ C1295ABI Ciudad Autónoma de Buenos Aires T+ 54 11 4361 5929 ÃÁÈÉÊËÄÌÍËÉÁÆÏÉÍÆÄ¾ Australia WILO Australia Pty Limited Murrarrie, Queensland, 4172 T +61 7 3907 6900 ÏѾÃËÆÒÄÓÂÉÁÊÔÃÌÉÆÏÉÍÆÄÕ Austria WILO Pumpen ÖËÂÀ¾¾ÀÃÏÑ×ÍØÙ 2351 Wiener Neudorf T +43 507 507-0 ÉÈÈÃÏÀÊÔÃÌÉÆÄ Azerbaijan WILO Caspian LLC 1014 Baku T +994 12 5962372 ÃÁÈÉÊÔÃÌÉÆÄÚ Belarus WILO Bel OOO 220035 Minsk T +375 17 2535363 ÔÃÌÉÊÔÃÌÉÆØÓ Belgium WILO SA/NV ÛÝÞß¼×ÄÁËÑɾÀÁ T +32 2 4823333 ÃÁÈÉÊÔÃÌÉÆØÀ Bulgaria àâèê¼ëÕ̿ľÃļèÂÒÆ 1125 Sofia T +359 2 9701970 ÃÁÈÉÊÔÃÌÉÆØ¿ Brazil WILO Brasil Ltda Jundiaí – São Paulo – Brasil ðâò¼ôÉÒÀ÷¼Û߯ùÛßûÛÝþ T +55 11 2923 (WILO) 9456 ÔÃÌÉÊÔÃÌÉûؾÄËÃÌÆÏÉÍÆØ¾ Canada àâèê¼ôÄÁÄÒļâÁÏÆ¼ Calgary, Alberta T2A 5L4 T +1 403 2769456 ØÃÌÌÆÌÉÔÀÊÔÃÌÉûÁÄÆÏÉÍ China àâèê¼ôÑÃÁļèÂÒÆ 101300 Beijing T +86 10 58041888 ÔÃÌÉØÿÊÔÃÌÉÆÏÉÍÆÏÁ Croatia àÃÌɼپÄÂËÄ¼ÒÆÉÆÉÆ 10430 Samobor T +38 51 3430914 ÔÃÌÉûѾÄÂËÄÊÔÃÌÉÆÑ¾ Czech Republic àâèê¼ôżËƾÆÉÆ ùþÛÝÛ¼ôÀËÂÌÃÏÀ T +420 234 098711 ÃÁÈÉÊÔÃÌÉÆÏÚ Denmark WILO Danmark A/S 2690 Karlslunde T +45 70 253312 ÔÃÌÉÊÔÃÌÉÆÒ Estonia WILO Eesti OÜ 12618 Tallinn T +372 6 509780 ÃÁÈÉÊÔÃÌÉÆÀÀ Finland WILO Finland OY 02330 Espoo T +358 207401540 ÔÃÌÉÊÔÃÌÉÆÈà France àâèê¼ÅƽÆÅÆ ÞßݼëÉÃ˼Ò½¾ÏÓ T +33 1 30050930 ÃÁÈÉÊÔÃÌÉÆÈ¾ Great Britain àâèê¼ Æ Æ ¼èÂÒÆ Burton Upon Trent DE14 2WJ T +44 1283 523000 ËÄÌÀËÊÔÃÌÉÆÏÉÆÕ Greece àâèê¼ÙÀÌÌÄ˼½× 14569 Anixi (Attika) T +302 10 6248300 ÔÃÌÉÆÃÁÈÉÊÔÃÌÉÆ¿¾ Hungary àâèê¼ Ä¿ÓľɾËÚ ¿¼ È ùÝþ¼¾Ø ÌÃÁ¼ (Budapest) T +36 23 889500 ÔÃÌÉÊÔÃÌÉÆÑÕ India àâèê¼âÁÒÃļ ÄÂÑÀ¾¼ÄÁÒ¼ òÌļòÕÍ˼èÂÒÆ Pune 411019 T +91 20 27442100 ËÀ¾ÃÏÀËÊÍÄÂÑÀ¾ÌÄÂÂÆÏÉÍ Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T +62 21 7247676 ÏþÄÔÃÌÉÊÏØÁÆÁÀÂÆÃÒ Ireland WILO Ireland èÃÍÀ¾ÃÏ T +353 61 227566 ËÄÌÀËÊÔÃÌÉÆÃÀ Italy àâèê¼âÂÄÌÃÄ¼ËÆ¾ÆÌÆ ùÝÝÞ¼òÀËÏÑÃÀ¾Ä¼ Borromeo (Milano) T +39 25538351 ÔÃÌÉÆÃÂÄÌÃÄÊÔÃÌÉÆÃ Kazakhstan WILO Central Asia 050002 Almaty T +7 727 2785961 ÃÁÈÉÊÔÃÌÉÆÚ Korea àâèê¼òÕÍ˼èÂÒÆ¼ ÛÞûùùݼ×ÄÁ¿ËÀɼëÕËÄÁ T +82 51 950 8000 ÔÃÌÉÊÔÃÌÉÆÏÉÆ¾ Latvia àâèê¼ëÄÌÂÃϼÅâ½ 1019 Riga T +371 6714-5229 ÃÁÈÉÊÔÃÌÉÆÌ Lebanon WILO LEBANON SARL ÒÀÃÒÀѼÛùÝù¼ùÝßݼ Lebanon T +961 1 888910 ÃÁÈÉÊÔÃÌÉÆÏÉÍÆÌØ Lithuania àâèê¼èÃÀÂÕļ ½ë 03202 Vilnius T +370 5 2136495 ÍÄÃÌÊÔÃÌÉÆÌ¼ Morocco WILO MAROC SARL 20600 CASABLANCA T + 212 (0) 5 22 66 09 24/28 ÏÉÁÂÄÏÂÊÔÃÌÉÆÍÄ The Netherlands àâèê¼ÀÒÀ¾ÌÄÁÒ¼ØÆÆ ÛþþÛ¼½¼àÀËÂÚÄÄÁ T +31 88 9456 000 ÃÁÈÉÊÔÃÌÉÆÁÌ Norway WILO Norge AS 0975 Oslo T +47 22 804570 ÔÃÌÉÊÔÃÌÉÆÁÉ Poland àâèê¼òÉÌËļÅÆ¼ÚÆÉÆÉÆ ÝþûþݼèÀËÚÁÉÔÉÌÄ T +48 22 7026161 ÔÃÌÉÊÔÃÌÉÆÌ Portugal Bombas Wilo-Salmson òɾÂÕ¿Ä̼èÒÄÆ 4050-040 Porto T +351 22 2080350 ØÉÍØÄËÊÔÃÌÉÆ Romania àâèê¼ÉÍÄÁÃÄ¼ËÆ¾ÆÌÆ ÝÝݼôÉÍÆ¼ôÑÃÄÿÁļ ÕÒÆ¼âÌÈÉ T +40 21 3170164 ÔÃÌÉÊÔÃÌÉÆ¾É Russia WILO Rus ooo Ûùßþù¼ ÉËÏÉÔ T +7 495 7810690 ÔÃÌÉÊÔÃÌÉÆ¾Õ Saudi Arabia àâèê¼ ¼û¼ÃÓÄÒÑ ÃÓÄÒѼÛÛþ T +966 1 4624430 ÔËÑÉÕÌÄÊÔÄÂÄÁÃÄÃÁÒÆÏÉÍ Serbia and Montenegro àâèê¼ëÀÉ¿¾ÄÒ¼ÒÆÉÆÉÆ 11000 Beograd T +381 11 2851278 ÉÈÈÃÏÀÊÔÃÌÉÆ¾Ë Slovakia àâèê¼ôÅ¼ËÆ¾ÆÉƼɾ¿Æ¼ðÌÉÄ ÞßÛݼë¾ÄÂÃËÌÄÄ T +421 2 33014511 ÃÁÈÉÊÔÃÌÉÆË Slovenia àâèê¼½Ò¾ÃÄÂÃÏ¼ÒÆÉÆÉÆ 1000 Ljubljana T +386 1 5838130 ÔÃÌÉÆÄÒ¾ÃÄÂÃÏÊÔÃÌÉÆËà South Africa ÅÄÌÍËÉÁ¼ÅÉÕÂѼ½È¾ÃÏÄ ÛÛݼÒÀÁÄÌÀ T +27 11 6082780 À¾¾ÉÌÆÏɾÁÀÌÃÕËÊ ËÄÌÍËÉÁÆÏÉÆÚÄ Spain àâèê¼âؾÃÏļů½Æ ùÞÞݼ½ÌÏÄÌ ¼ÒÀ¼ÙÀÁľÀ˼ (Madrid) T +34 91 8797100 ÔÃÌÉÆÃØÀ¾ÃÏÄÊÔÃÌÉÆÀË Sweden àâèê¼ÅÀ¾Ã¿À¼½ë 35246 Växjö T +46 470 727600 ÔÃÌÉÊÔÃÌÉÆËÀ Switzerland  ë¼òÕÍÀÁ¼½× ßÛݼÑÀÃÁÈÀÌÒÀÁ T +41 61 83680-20 ÃÁÈÉÊÀÍØûÕÍÀÁÆÏÑ Taiwan àâèê¼ÄÃÔÄÁ¼ôÉÍÄÁÓ¼èÂÒÆ ÅÄÁÏÑÉÁ¿¼ÃËÂÆ¼ÀÔ¼ÄÃÀü City 24159 T +886 2 2999 8676 ÁÀÌËÉÁÆÔÕÊÔÃÌÉÆÏÉÍÆÂÔ Turkey WILO Pompa Sistemleri ÅÄÁƼÀ¼ÃÏÆ¼½ÆÅÆ ßþ¼ËÂÄÁØÕÌ T +90 216 2509400 ÔÃÌÉÊÔÃÌÉÆÏÉÍÆÂ¾ Ukraina àâèê¼ ¾ÄÃÁÄ¼ÂÆÉÆÔÆ ÝÛÝßß¼ ÃÀÔ T +38 044 2011870 ÔÃÌÉÊÔÃÌÉÆÕÄ United Arab Emirates WILO Middle East FZE ÀØÀ̼½Ìü¾ÀÀ¼ðÉÁÀÅÉÕÂÑ PO Box 262720 Dubai T +971 4 880 91 77 ÃÁÈÉÊÔÃÌÉÆÄÀ USA WILO USA LLC Rosemont, IL 60018 T +1 866 945 6872 ÃÁÈÉÊÔÃÌÉûÕËÄÆÏÉÍ Vietnam àâèê¼ÃÀÂÁÄͼôɼèÂÒÆ ÙɼôÑü ÃÁѼôÃÂÓ¼ÃÀÂÁÄÍ T +84 8 38109975 ÁÍÃÁÑÊÔÃÌÉÆÁ May 2013 Õ¾ÂÑÀ¾¼ËÕØËÃÒÃľÃÀ˼¾À¾ÀËÀÁÂÄÂÃÉÁ¼ÄÁÒ¼ËÄÌÀ˼ÉÈÈÃÏÀ˼ÉÁ¼ÔÔÔÆÔÃÌÉÆÏÉÍ