�01] Read carefully these instructions before using the machine.
User instructions
PRO6 Solo
. -------------------------- -·
�Client,
congratulations on your purchase of your Pro6 Solo. This versatile steam
cleaning system was designed for Professional application requirements in
compliance with the strictest standards of safety and efficiency.
You will soon see how easy, simple and safe it is to use PRO6 Solo.
To become acquainted with the possibilities of this device for household and
work maintenance, we recommend that you read these instructions all the way
through carefully and then follow these instructions step by step.
1
GETTING TO KNOW THE Pro6 Solo
1 Safety pressure cap / Boiler
2 Carry handle
3 Steam switch
4 Main switch
5 "No water" warning light
6 "Steam ready" light
7 Pressure gauge
8 Steam regulator knob
9 Monobloc socket
DESCRIPTION OF ACCESSORIES
10 Rectangular brush
1 Oa Carpet Glider
11 Extension tubes
12 Triangular brush
13 Jet Nozzle 1 hole
13a Jet Nozzle 3 holes
14 Extended Nozzle w/
rubber protection
15 Window wiper
16 Small round brush
(nylon)
16a Small round brush
(brass)
16b Small round brush
(stainless steel)
10
19
17 Round brush (nylon)
18 Standard Hose
19 Small triangular brush
for Jet Nozzle (nylon)
21 Fill bottle
18
3
12
�
17
�
15
L 14
�
3HOLE-�
1HOLE-�
13a
13
21
Please test inconspicuous parts of all surfaces and objects to ensure colour-fastness
and heat resistance. We will not be liable for damage caused by failure to test the
surfaces to be cleaned.
1)
Never open the filler cap while the boiler is under pressure. Release the pressure using
the steam button on the pistol grip only.
2)
Do not add detergents or other additives. Use only filtered water- no distilled water.
2) Take care to ensure that the electrical data on the type plate corresponds to the local net
work voltage.
4) Never dip the device in the water.
5) Disconnect plug when the device is not in use or is to be left unattended, or when filling
the tank or cleaning the device.
6) You must only use the PRO6 Solo for the applications described in these instructions.
7) Use only original replacement and accessory parts.
8) Do not pull the electrical cord out of the socket by the cord.
9) Do not allow the electrical cord to come into contact with hot surfaces.
10)
The steam generated by the device can reach very high temperatures (150°C) upon
leaving the device. Avoid all contact with the steam. Do not point the steam spray at per
sons or animals.
11)
This device is not a toy. Special care is required when used by children or in the
vicinity of children.
12)
Never use steam to clean electrical devices, such as radios, televisions.
13)
When using the electric iron, take care to ensure that the iron is safely stowed at all
times (for example, the support base on the table).
14)
Only put the PRO6 Solo away after it has completely cooled off. The tank need not be
emptied unless the device is to remain unused for a long time.
15)
Do not use the device if it has been damaged, steam escaping or if the electrical cord
or any of the accessory parts are damaged. Inspections and repairs of all kinds must
always be performed by our client service department. Unauthorized repair work may be
dangerous and will void the warranty.
4
• Push filler cap (1) downwards, then twist left and
screw open.
• Fill tank with as much water as possible (maximum
filling quantity 2 litres). Use only filtered water .
Do not use distilled water.
• Press filler cap downwards, then twist right and
screw shut.
• Connect electrical cord to the socket.
• Tum on main switch (4). Diode lights up: device is
heating up. As soon as the green control lamp
light on the pressure indicator (6) lights up, the
device is ready for operation.
• Connect hose with spray gun (18). Be sure that the
coupler plug is correctly engaged!
• When device is ready for operation, tum on the
steam supply line switch (3).
• Screw the steam regulator (8) open and adjust
according to the application.
6
LARGE CLEANING BRUSH (10 - 1 OA)
Cleaning hard floors
Stick the extension tube onto the spray pistol and attach the large cleaning brush to the
extension tube. Pass over the floor with even movements.
Pause a bit longer over joints and uneven places, to dissolve deeply-ingrained dirt. Repeat
several times if necessary.
Finally, clamp a dry wipe cloth around the brush and wipe the whole surface clean.
The floor will shine like new.
For linoleum, proceed carefully, using very little steam; or, better yet, use a dry wipe cloth
to retain the floor's natural brilliance.
Cleaning carpets with the brush cover
Using the PRO6 Solo, textile wall-to-wall carpets, rugs and even Persian carpets can be
cleaned and disinfected, eliminating even animal hair and house mites, without chemicals
and additives, restoring the original colour and providing renewed brilliance.
The elimination of deeply ingrained dirt and detergent residues left over from previous cle
aning attempts may require several treatments for the best results.
For after-treatment, simply repeat the process, using a dry wipe cloth clamped over the
brush attachment.
For first-time cleaning following the process, use a vacuum cleaner only.
Slide the brush cover (10a) over the brush (10) and allow it to latch into place. This allows
the attachment to glide easily and smoothly over the floor, without damaging the carpeting,
aspirating away any dirt as a result of the steam vortex effect and resulting under-pressure
generated around the brushes by the brush cover.
8
Depending on the quality, rugs and carpets should be cleaned carefully with very little
steam and then brushed with a clean, dry cloth over the brush attachment.
Cloth carpets, mattresses and bed frames can be cleaned and disinfected in the same way
(house mites, germs, bacteria).
Cleaning of sealed parquet and marble floors
Firmly attach a triple-folded dry wipe cloth to the cleaning brushes and wipe evenly.
Cleaning of walls, ceilings and high glass panes
Extend the tubes according to the height of the room and insert the large cleaning brush
with carpet glider and clip towels over.
Important: Change the cloth when it gets dirty.
Be careful with water-soluble colours!
TRIANGULAR BRUSH (optional 12)
The triangular brush is used wherever working with the large brushes is laborious and
impossible due to lack of room.
Special applications:
• Furniture covers and car seats (not leather)
Cover the triangular brush with a clean, dry cloth and fasten it tight. Treat stubborn stains
carefully with the spray gun. Spray steam from a distance of about 10 cm away, and dab
with a clean, dry cloth or carefully rub dry.
• Textiles
Clothing, blankets, curtains, mattresses and upholstery can not only be cleaned, but freshened
up as well. Cover the triangular brush with a cloth as described above and brush down the texti
les lightly, or steam evenly from a short distance away. The steam penetrates and relaxes the
fibres, restoring the shape of the fabric.
Important: With textiles of any kind, always follow the manufacturer instructions
and/or test for colour fastness on an inconspicuous part of the fabric.
9
WINDOW WIPER {15)
To get dirt and grease off windows has never been easier. Fit the machine with the appro
priate window accessory Direct steam onto the windows and get rid of the dirt with the rub
ber squeegie. Jet nozzle and fogg the window and clean with microfiber towel provides
excellent results
Attention: In winter pre-heat the windows!Start cleaning only after spraying some
steam from a distance of about 5-l0cm.
FILLING THE BOILER
If the steam of the DIAMANT finishes while using the machine, the "water level" warning
light lights up. The boiler must then be refilled with water.
Proceed as follows:
le.
Leave steam switch (3) on
2c. Turn off the main switch 4.
3c.
Operate steam trigger (Gl) on handle
4c.
Disconnect electrical cord from the wall socket (9).
5c. Unscrew safety plug (1) turning it in an anticlockwise direction.
6c. Wait for a few minutes to let the boiler cool down.
7c.
Fill the machine as described in the GETTING STARTED chapter. If filling the tank
when hot, add small quantities of water in order to prevent water from evaporating straight
away. To fill the tank use filler bottle (21).
8c. Close the machine and plug it in again, switch the general switch on and wait for "pres
sure" light (6) to light up.
9c. The PRO6 Solo is ready for use again!
10
Switch boiler switch (4) off
•
Vent the remaining steam using steam button (Gl) or iron (25).
•
Unplug supply cable from the mains (9).
•
Let the machine cool down before putting it away.
11
FINISHING USING THE MACHINE
Switch boiler switch (4) off
Vent the remaining steam using steam button (Gl).
Unplug supply cable from the mains (9).
Let the machine cool down before putting it away.
Since the DIAMANT is operated with mains water, regular decalcification is required to
assure the useful life of the device as ensure proper functioning. The frequency of decalci
fication will depend on water hardness and duration of utilisation.
For average water hardness (10°-15°) and normal use in a private household, we recom
mend that the device be decalcified at least every three months.
Please proceed as follows:
•
Fill the tank half full (approximately I litre of water) and add a commercially available
decalcifier in the appropriate quantity.
•
Screw the filler cap tight
•
Turn on the main switch and steam supply line switch
•
Wait until the diode lights up
•
Turn the main switch off again and fully release the steam pressure to the spray gun
using the steam button
•
Allow the device to cool for a few minutes
•
Empty the device and rinse the tank twice with clear water
• When using cleansing vinegar, allow the device to stand for a few hours or over night
before emptying it, and then rinse it thoroughly several times
Important: The drain screw to empty the tank is located on the bottom of the device.
Do not open before releasing all steam.
After emptying the tank, retighten the screw.
TECHNICAL DATA
Input
Boiler output
Boiler capacity
Steam temperature
Maximum pressure
Profi electric iron
Boiler
120V-60Hz
1500W
21
150°c / 315°F
500 kPa (5 bar)
850W
Stainless
12