Titon auralite TP519 Quick Start Manual

Text of the manual

Important: Read these instructions fully before installation.

1. Installation of the appliance and accessories MUST be carried out by a qualified and suitable competent person. 2. All wiring must conform to current I.E.E. Wiring Regulations and all applicable national standards and Building Regula- tions. 3. Installation must be inspected and tested by a suitably quali- fied person after completion. 4. Installation of the appliance must be carried out in clean, dry conditions where dust and humidity are at minimal levels. 5. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 6. Children should be supervised to ensure that they do not play with the appliance. ventilation systems auralite® TP519 B Model LED Status Indicator

auralite® is a low voltage hard wired remote LED ventilation system status indicator,

designed to fit a standard UK patress or recessed backbox. The indicator is for use with specific Titon HRV units. The indicator has six LEDs which display:- y Normal Solid light - Unit is running at Continuous Speed. Flashing light- Unit is running at Setback Speed. y Frost Solid light - Unit is in Automatic Frost Protection mode. Flashing Light - Internal Frost Protection Mode, indoor temperature low, both fans stopped. y Filter Filters require change. y Boost Solid light- Unit is running at Boost Speed. Flashing light - Unit is running at SUMMERboost®/Speed 4. � Summer Unit is in Summer Bypass Mode. y Fault Unit has a fault - Contact the installer. y Normal / Boost Alternate flashing indicates demand control from proportional sensors. Ventilation System auralite® Indicator Panel

DO 5539 Issue 01

Wiring 1. auralite® Communication Cable - Unshielded 4 Core 18-24AWG Stranded, Tinned Copper. 2. Communication cable should not be placed within 50mm or on the same metal cable tray as 230V switched live, lighting or power cables and any cables not intended for use with the HRV. Filter notification reset Following a filter change to HRV the auralite® will require resetting, see below. Ensure the HRV is powered up. To clear the auralite® filter notification press & hold the reset switch with a ball point pen or similar object for 20 seconds. The switch is located behind the small hole in the front of the auralite®. All lights will momentarily be illuminated indicating a successful reset. MARKETING DIVISION 894 The Crescent Colchester Business Park COLCHESTER Essex CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: [email protected] Web: www.titon.com

Other Measuring Instruments Manuals