Dexing DHP400 Operation & User’s Manual

Text of the manual

Head-end Processor User Manual

SW Version: 2.21 Build 141.00 Apr 29 2016 HW version: 0.10.0.8 Web NMS version: 2.1 20142014 DEXIN DIGITAL TECHNOLOGY CORP. LTD.

About This Manual

Intended Audience This user manual has been written to help people who have to use, to integrate and to install the product. Some chapters require some prerequisite knowledge in electronics and especially in broadcast technologies and standards. Disclaimer No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. DEXIN shall have no liability for any error or damage of any kind resulting from the use of this document. Copy Warning This document includes some confidential information. Its usage is limited to the owners of the product that it is relevant to. It cannot be copied, modified, or translated in another language without prior written authorization from DEXIN. �

Chapter 1 Product Overview.......................... 1

1.1 Outline ........................................................ 1 1.2 Features ...................................................... 1 1.3 Specifications.............................................. 1 Chapter 2 Physical Presentational Statement2 2.1 Appearance and Description .................... 2 Chapter 3 Installation Guide.......................... 5 3.1 Acquisition Check...................................... 5 3.2 Installation Preparation............................ 5 3.3 Wire’s Connection..................................... 7 Chapter 4 Web NMS Management................ 9 4.1 Login ........................................................... 9 4.2 Operation.................................................. 10 Chapter 5 Troubleshooting........................... 50 Chapter 6 Packing list................................ 52

DHP400 Head-end Processor User Manual 1

Chapter 1 Product Overview 1.1 Outline DHP400 DTV head-end processor is the new generation of intelligent headend processing equipment. This 1-U case comes with 6 independent module slots. Each module can be configured individually based on the applications including encoding, decoding, trans-coding, multiplexing, descrambling and modulating processing and the combination of all these functions. It supports multiple input and output interfaces and signal formats. With its powerful performance and low cost, DHP400 is especially adequate for the new generation CATV system. 1.2 Features  Support Web management, Updates via web  Support flexible combination of different type of modules  Support up to 6 modules  Redundancy power supply (optional)  Support 1 ASI output (MPTS2)  Support 2 GE output, 512 SPTS (UDP, RTSP/RTP) output from GE1, 8 MPTS (UDP,RTP) output from GE2, Unicast/Multicast, RJ45/SFP interface  Support Web management, Updates via web 1.3 Specifications (For each module’s parameters, please see DHP400 Head-end processor SPEC)

DHP400 Head-end Processor User Manual 2

Chapter 2 Physical Presentational Statement 2.1 Appearance and Description Front Panel Illustration 2 3 4 5 6 7 1 1 Air Vent 2 ASI output port 3 GE1/GE2 Output: IP signal output, SFP connector 4 Reset: Reset webmaster IP address, recover it to default IP address 5 GE1/GE2 Output: IP signal output, RJ45 connector 6 NMS: network management system /CA communication, Ethernet interface 7 Indicators 1U chassis support up to 6 modules, users can freely select different module types and freely exchange modules’ position, and here we just take one case as an example. Rear Panel Illustration

DHP400 Head-end Processor User Manual 3

Module Illustration: DX504 4 ASI/IP Multiplexing Module DX505 5 ASI Multiplexing Module DX214 4 CVBS Encoding Module DX202A 2 HDMI Encoding/Transcoding Module DX202A-D 2 SDI Encoding/Transcoding Module DX224 4 HDMI Encoding Module

DHP400 Head-end Processor User Manual 4

DX202 2 IP Transcoding Module DX702 2 HD-SDI Decoding Module DX316/332 16/32 QAM Modulating Module DX308T 8 DVB-T Modulating Module DX308C 8 ATSC Modulating Module DX306I 6 ISDB-Tb Modulating Module DX902 2 Tuner(DVB-S/S2) Descrambling Module DX912 2 Tuner(DVB-C) Descrambling Module DX904 4 FTA Tuner(DVB-S/S2) Module DX914 4 FTA Tuner(DVB-C) Module DX944 4 FTA Tuner(DVB-T/T2) Module

DHP400 Head-end Processor User Manual 5

Chapter 3 Installation Guide 3.1 Acquisition Check When user opens the package of the device, it is necessary to check items according to packing list. Normally it should include the following items:  DHP400 Head-end processor  User’s Manual  Power Cord If any item is missing or mismatching with the list above, please contact local dealer. 3.2 Installation Preparation When users install device, please follow the below steps. The details of installation will be described at the rest part of this chapter. Users can also refer rear panel chart during the installation. The main steps of the installation include:  Checking the possible device missing or damage during the transportation  Preparing relevant environment for installation  Installing DHP400 head-end processor  Connecting signal cables  Connecting communication port (if it is necessary) 3.2.1 Device’s Installation Flow Chart Illustrated as follows:

DHP400 Head-end Processor User Manual 6

3.2.2 Environment Requirement Item Requirement Machine Hall Space When user installs machine frame array in one machine hall, the distance between 2 rows of machine frames should be 1.2~1.5m and the distance against wall should be no less than 0.8m. Machine Hall Floor Electric Isolation, Dust Free Volume resistivity of ground anti-static material: 1X107~1X1010, Grounding current limiting resistance: 1M (Floor bearing should be greater than 450Kg/㎡) Environment Temperature 5~40℃(sustainable ), 0~45℃(short time) installing air-conditioning is recommended Relative Humidity 20%~80% sustainable 10%~90% short time Pressure 86~105KPa Door & Window Installing rubber strip for sealing door-gaps and dual level glasses for window Wall It can be covered with wallpaper, or brightness less paint. Fire Protection Fire alarm system and extinguisher Power Requiring device power, air-conditioning power and lighting power are independent to each other. Device power requires AC power 220V ±10% 50/60Hz or 110V ±10% 50/60Hz. Please carefully check before running. 3.2.3 Grounding Requirement

DHP400 Head-end Processor User Manual 7

 All function modules’ good grounding is the basis of reliability and stability of devices. Also, they are the most important guarantee of lightning arresting and interference rejection. Therefore, the system must follow this rule.  Coaxial cables’ outer conductor and isolation layer should keep proper electric conducting with the metal housing of device.  Grounding conductor must adopt copper conductor in order to reduce high frequency impedance, and the grounding wire must be as thick and short as possible.  Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.  It is prohibited to use any other device as part of grounding electric circuit  The area of the conduction between grounding wire and device’s frame should be no less than 25mm2. 3.2.4 Frame Grounding All the machine frames should be connected with protective copper strip. The grounding wire should be as short as possible and avoid circling. The area of the conduction between grounding wire and grounding strip should be no less than 25mm2. 3.2.5 Device Grounding Connecting the device’s grounding rod to frame’s grounding pole with copper wire. 3.3 Wire’s Connection

DHP400 Head-end Processor User Manual 8

3.3.1 Power cord connection The power socket is located on the right of rear panel, and the power switch is on the left of front panel. User can plug one end of the power cord to the socket and insert the other end to AC power. When the device solely connects to protective ground, it should adopt independent way, say, share the same ground with other devices. When the device adopts united way, the grounding resistance should be smaller than 1Ω. Caution: Before connecting power cord to DHP400 head-end proccesor, user should set the power switch to “OFF”. 3.3.2 Signal and NMS Cable Connection The signal connections include the connection of input signal cable and the connection of output signal cable.

DHP400 Head-end Processor User Manual 9

Chapter 4 Web NMS Management This device does not support the LCD operation, and the modification can only be operated under Web NMS. 4.1 Login The factory default IP address is 192.168.000.136 and users can connect the device and web NMS through this IP address. Connect the PC (Personal Computer) and the device with a net cable, and use ping command to confirm they are on the same network segment. For instance, the PC IP address is 192.168.000.252, we then change the device IP to 192.168.000.xxx (xxx can be 0 to 255 except 252 to avoid IP conflict). Launch the web browser an input the device IP address in the browser’s address bar and press Enter. It will display the Login interface as Figure-1. Input the Username and Password (Both the default Username and Password are “admin”. And then click “Sign In” to start the device setting. Figure-1

DHP400 Head-end Processor User Manual 10

4.2 Operation 4.2.1 Summary When we confirm the login, it displays the SUMMARY interface as Figure-2. Indicators—Green light indicates the TS is normal, which otherwise the run indicator turns to red. User can click any item here to enter the corresponding interface to check information or set the parameters. Figure-2 Parameters → Module1-6: From the menu on left side of the webpage, clicking “Module1-6”, it displays the interface as below. Different module has different interface for parameter setting. 1. DX504 4 ASI/IP Multiplexing Module DX504 module has 4 ASI input or output through 4 ASI bi-direction port, and 2 GE input or output port, each GE port support 256 IP input. Users click “input CH” to set DX504 modules parameters and it display the interface as below (Figure-3):

DHP400 Head-end Processor User Manual 11

Users click here to set the corresponding parameters Figure-3 Users click “Batch” to set the IP input and general mux parameters for this module, and it display the interface as below (Figure-4):

DHP400 Head-end Processor User Manual 12

Figure-4 Users click “Mux” to set the mux parameters, and it display the interface as below (Figure-5): Note: “module export” indicates that the TS will be exported to main board, and “Connector” indicate that the TS from main board after processing.

DHP400 Head-end Processor User Manual 13

Programs from ASI1-4 and connector Input Area Programs which output CH 1 received Output Area Operation Area Select mux-output channel, there are 5 options: CH 1/2/3/4 and 1 module export Users can select the programs input port Figure-5 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the CA filter : To enable/disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure-6) where users can input new information.

DHP400 Head-end Processor User Manual 14

Figure-6 From the menu on up side of the webpage, clicking “General”, user can set the parameters of the each output carriers. It displays the interface as Figure-7. Figure-7 From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which needs pass through. (Figure-8)

DHP400 Head-end Processor User Manual 15

Click this button to generate more rows to add PIDs. Figure-8 DX504 also supports TS output with 4 channels through the two GE port. Each channel for GE1 and GE2 has independent IP address and IP number. Click ‘IP Stream’, it will display the interface as Figure-9 where to set IP out parameters. Figure-9 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-10) where users can check and set this module’s system information.

DHP400 Head-end Processor User Manual 16

Figure-10 2. DX505 5 ASI Multiplexing Module DX505 module has 5 ASI bi-direction port for input and output. Users click “In-Out” to set the 5ASI direction and it display the interface as below (Figure-11): Click here to select the ASI direction Figure-11 Users click “Mux” to set the mux parameters, and it display the interface as below (Figure-12): Note: “module export” indicates that the TS will be exported to main board, and

DHP400 Head-end Processor User Manual 17

“Connector” indicate that the TS from main board after processing. Select mux-output channel, there are 5 options: ASI 1/2/3/4/5 and 1 module Programs from ASI1-4 and connector Input Area Output Area Programs which output CH 1 received Operation Area Figure-12 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the CA filter : To enable/disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure-13) where users can input new information.

DHP400 Head-end Processor User Manual 18

Figure-13 From the menu on up side of the webpage, clicking “General”, user can set the parameters of the each output carriers. It displays the interface as Figure-14. Figure-14 From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which needs pass through. (Figure-15)

DHP400 Head-end Processor User Manual 19

Click this button to generate more rows to add PIDs. Figure-15 From the menu on up side of the webpage, clicking “PID Monitor”, it displays the interface where to set the PID parameters. (Figure-16) Figure-16 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-17) where users can check and set this module’s system information.

DHP400 Head-end Processor User Manual 20

Figure-17 3. DX214 4 CVBS Encoding Module DX214 has 24 CVBS input interfaces and 24 pairs of unbalanced analogue stereo audio input interfaces, Users click “Encoding CH1-CH4” to set the encoding parameters and it display the interface as below (Figure-18): Each channel’s information and modules’ system information Figure-18 Click this button to apply the modified parameters. Users click “System” to check the system information for each module, and it display the

DHP400 Head-end Processor User Manual 21

interface as below (Figure-19): Figure-19 4. DX202A 2 HDMI Decoding Module DX202A module has 2 HDMI input, and this module can be used as transcoding module or encoding module. Users click “Encoder/Transcoder 1/2” to set the parameters and it display the interface as below (Figure-20): Figure-20 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-21) where users can check and set DX202A module’s system information.

DHP400 Head-end Processor User Manual 22

Figure-21 5. DX202A-D 2 SDI Encoding/Transcoding Module DX202A-D module has 2 SDI input, and this module can be used as transcoding module or encoding module. Users click “Encoder/Transcoder 1/2” to set the parameters and it display the interface as below (Figure-22): Figure-22

DHP400 Head-end Processor User Manual 23

From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-23) where users can check and set DX202A-D module’s system information. Figure-23 6. DX224 4 HDMI Encoding Module DX224 support 4 HDMI input channel, Users click “Tuner1-2” to configure the input tuner parameters to receive satellite signals and it display the interface as below (Figure-24): Each channel’s information and modules’ system information Figure-24 Click this button to apply the modified parameters. Users click “System” to check the system information for each module, and it display the interface as below (Figure-25):

DHP400 Head-end Processor User Manual 24

Figure-25 7. DX202 2 IP Transcoding Module DX202 module is a transcoding module which supports video and audio transcoding, and because of DX202 without input or output port, it should be used combine with other module. Users click “CH1/CH2” to set parameters and it display the interface as below(Figure-26): Figure-26 Users click “System” to check the system information, and it display the interface as below (Figure-27):

DHP400 Head-end Processor User Manual 25

Figure-27 8. DX702 2 HD-SDI Decoding Module DX702 module has 2ASI input and 2 SDI output. DX702 ASI port can be used as input or output port, and users click “In-Out” to select the ASI direction and it display the interface as below (Figure-28): Figure-28

DHP400 Head-end Processor User Manual 26

Users click “Mux” to set the mux parameters, and it display the interface as below (Figure-29): Input Area Output Area Operation Area There are 4 options Figure-29 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the CA filter : To enable/disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure-30) where users can input new information.

DHP400 Head-end Processor User Manual 27

Figure-30 From the menu on up side of the webpage, clicking “General”, user can set the ASI output1, ASI output2 and module1 export general parameters of this module. It displays the interface as Figure-31. Figure-31 From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which needs pass through. (Figure-32)

DHP400 Head-end Processor User Manual 28

Click this button to generate more rows to add PIDs. Figure-32 DX702 module supports to decode up to 2 programs to output simultaneously through the SDI ports. From the menu on up side of the webpage, clicking “Decoder”, it displays the interface where users can configure the Video/Audio output parameters respectively (Figure-33). Figure-33 Operation steps are as below: 1) Specify the decoding channel. 2) Click button to parse out all the input programs available. 3) Configure V/A parameters and select the target program to be decoded out.

DHP400 Head-end Processor User Manual 29

4) Click button at last to confirm. Wait for a moment until the status light turns to green. From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-34) where users can check and set DX702 module’s system information. Figure-34 9. DX316/332 16/32 QAM Modulating Module 10. DX308T 8 DVB-T Modulating Module 11. DX308C 8 ATSC Modulating Module 12. DX306I 6 ISDB-Tb Modulating Module DX316/332/308T/308C/306I is modulating modules which support IP to DVB-C/T/T2/ATSC/ISDB-Tb modulate. DX316/332/308T/308C/306I has a similar NMS interface, so here we just take one as an example. From the menu on up side of the webpage, clicking “Mux-Output CH X”, it displays the interface as Figure-35. Users can select the output TS channels.

DHP400 Head-end Processor User Manual 30

Figure-35 From the menu on up side of the webpage, clicking “General”, it displays the interface where users can set parameters for each output channel. (Figure-36) Figure-36 Users click the interface is display as below, and click to apply the modified parameters.(Figure-37)

DHP400 Head-end Processor User Manual 31

Figure-37 From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which need pass through. (Figure-38) Figure-38 DX306I supports TS to output in IP (6*MPTS) format through the DATA port. Click ‘IP Stream’, it will display the interface as Figure-39 where to set IP out parameters. Figure-39 From the menu on left side of the webpage, clicking ‘Modulator’, it will display the interface as Figure-40 where to set RF output parameters.

DHP400 Head-end Processor User Manual 32

Click to set all channels RF output parameters Click to set each channel RF output parameters Figure-40 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-41) where users can check and set DX306I module’s system information.

DHP400 Head-end Processor User Manual 33

Figure-41 13. DX902 2 Tuner(DVB-S/S2) Descrambling Module 14. DX912 2 Tuner(DVB-C) Descrambling Module DX902/912 module has 2 DVB-S/S2/DVB-C tuner inputs. Users click “Tuner1-2” to configure the input tuner parameters to receive satellite signals and it display the interface as below (Figure-42): Input right information in this area as per the source signal, and then click ‘Apply’ button below to receive satellite signals. Figure-42 DX902/912 supports 2 CI cards to descramble programs from Tuner input. Users can click and enter ‘CI Card’ to configure the 2 cards respectively. (Figure-43)

DHP400 Head-end Processor User Manual 34

Card Selection Area Figure-43 One CI card can be applied to descramble programs from the 2 Tuner input signal sources. ‘Skip CI card’ means to skip the card which is used for FTA stream. Users can decide whether to enable the card error check function by checking the box. After configuring CI card parameters, click button to apply the input data and then click button to parse programs from the channel selected in ‘Input TS Mode’. The searched out programs will be listed in the ‘Descramble’ box below: (Figure-44)

DHP400 Head-end Processor User Manual 35

Program list from the channel selected in ‘Input TS Mode’ Figure-44 Check the program(s) to be descrambled and click button to start descrambling the checked program(s). The program quantity to be descrambled will depend on the CAM/CI performance you apply to. Number behind slash indicates the whole programs from the selected channel. Number before slash indicates the programs which have been descrambled. Users can also read the program information by clicking ‘+’ symbol. From the menu on up side of the webpage, clicking “BISS”, it displays the interface where users can configure 2 BISS and descramble the input channels and it displays the interface as below (Figure-45):

DHP400 Head-end Processor User Manual 36

Figure-45 From the menu on up side of the webpage, clicking “Mux”, it displays the interface where users can choose the programs from 2 Tuner and connect input to Mux out. (Figure-46) Output Area Input Area Operation Area Figure-46 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the CA filter : To enable/disable the PID remapping

DHP400 Head-end Processor User Manual 37

To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure-47) where users can input new information. Figure-47 Input new data and click ‘Save’ button at last to confirm the modification. From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which needs pass through. (Figure-48)

DHP400 Head-end Processor User Manual 38

Click this button to generate more rows to add PIDs. Figure-48 From the menu on up side of the webpage, clicking “General”, user can set the parameters of the each output carriers. It displays the interface as Figure-49. Figure-49 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-50) where users can check and set this module’s system information.

DHP400 Head-end Processor User Manual 39

Figure-50 15. DX904 4 FTA Tuner(DVB-S/S2) Module 16. DX914 4 FTA Tuner(DVB-C) Module 17. DX944 4 FTA Tuner(DVB-T/T2) Module DX904/914/944 module has 4 DVB-S/S2/DVB-C/DVB-T/T2 tuner inputs. Users click “Tuner1-4” to set the RF parameters and it display the interface as below (Figure-51): Figure-51

DHP400 Head-end Processor User Manual 40

Because of DX904/914/944 module without output port, it should be used combine with other module. Users click “Mux” to set the mux parameters, and it display the interface as below (Figure-52): Programs from 4 tuners Input Area Output Area Operation Area Figure-52 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the CA filter

DHP400 Head-end Processor User Manual 41

: To enable/disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure 53) where users can input new information. Figure-53 From the menu on up side of the webpage, clicking “PID Pass”, it displays the interface where to add the PIDs which needs pass through. (Figure-54)

DHP400 Head-end Processor User Manual 42

Click this button to generate more rows to add PIDs. Figure-54 From the menu on up side of the webpage, clicking “General”, user can set the general parameters of this module. It displays the interface as Figure-55. Figure-55 From the menu on up side of the webpage, clicking “System”, it displays the interface (Figure-56) where users can check and set DX904 module’s system information.

DHP400 Head-end Processor User Manual 43

Figure-56 Parameters →Stream Connect: From the menu on left side of the webpage, clicking “Stream Connect”, user can select programs from each module and mux to connector X. DHP400 support 6 module output, 8 MPTS (only output via GE2) and 512 SPTS (only output via GE1), and ASI output programs are same as MPTS2.It displays the interface as Figure-57. Input Area Output Area Figure-57 Here “Module X export indicates” the TS from module X, “Connector X” indicates the TS will be output via moduleX.

DHP400 Head-end Processor User Manual 44

Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To enable/disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output. Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure 58) where users can input new information. Figure-58 From the menu on up side of the webpage, clicking “General”, user can set the general parameters of the corresponding connector. It displays the interface as Figure-59.

DHP400 Head-end Processor User Manual 45

Figure-59 Note: users can only click “Stream Select ” to check the stream connect status when stay on “General” web page.( Figure-60) Figure-60 Parameters → IP Stream: DHP400 supports TS to output in IP format through the DATA port. Click ‘IP Stream’, it will display the interface as Figure-61 where to set IP out parameters.

DHP400 Head-end Processor User Manual 46

Figure-61 Parameters → General: users can only click “General ” to debug module.( Figure-62) Figure-62 System → Network: Click ‘Network’, it will display the interface as Figure-63 where to set network parameters.

DHP400 Head-end Processor User Manual 47

Figure-63 System → Password: From the menu on left side of the webpage, clicking “Password”, it will display the screen as Figure-64 where to set the login account and password for the web NMS. Figure-64 System → Configuration: From the menu on left side of the webpage, clicking “Configuration”, it will display the screen as Figure-65 where to set your configurations for the device.

DHP400 Head-end Processor User Manual 48

Select areas Figure-65 System → Firmware: From the menu on left side of the webpage, clicking “Firmware”, it will display the screen as Figure-66 where to update firmware for the device. Figure-66 System → Log: From the menu on left side of the webpage, clicking “Log”, it will display the screen as Figure-67 where to check the “Log”.

DHP400 Head-end Processor User Manual 50

Chapter 5 Troubleshooting DEXIN’s ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All DEXIN products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by DEXIN. To prevent potential hazard, please strictly follow the operation conditions. Prevention Measure  Installing the device at the place in which environment temperature between 0 to 45 °C  Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores if necessary  Checking the input AC voltage within the power supply working range and the connection is correct before switching on device  Checking the RF output level varies within tolerant range if it is necessary  Checking all signal cables have been properly connected  Frequently switching on/off device is prohibited; the interval between every switching on/off must greater than 10 seconds. Conditions need to unplug power cord  Power cord or socket damaged.  Any liquid flowed into device.

DHP400 Head-end Processor User Manual 51

 Any stuff causes circuit short  Device in damp environment  Device was suffered from physical damage  Longtime idle.  After switching on and restoring to factory setting, device still cannot work properly.  Maintenance needed

DHP400 Head-end Processor User Manual

52 Chapter 6 Packing list  DHP400 Head-end processor  User’s Manual  Power Cord