Danfoss vlt series Operating Instructions Manual
Read Online
Read the Danfoss vlt series Operating Instructions Manual online using the built-in PDF viewer.
Text of the manual
1 General Information
3
1.1 Important Safety Warnings
3
1.2 Copyright
3
1.3 Product Names and Trademarks
3
1.4 Disclaimer
3
1.5 Approvals
3
1.6 Service and Support
4
2 Introduction
5
2.1 System Overview
5
2.2 Terminology
6
2.3 Purpose of the Operating Instructions
6
2.4 Additional Resources
6
3 Safety
7
3.1 Symbols used in this Manual
7
3.2 General
7
3.3 Safety Instructions and Precautions for the ISD 410 Servo System
7
3.4 Qualified Personnel
9
3.5 Due Diligence
9
3.6 Intended Use
9
3.7 Foreseeable Misuse
10
4 Introduction
11
5 Mechanical Installation
12
5.1 Cooling
12
5.2 Mounting
12
6 Electrical Installation
14
6.1 Earth (Grounding) Requirements
14
6.2 Overview
15
6.3 Installation Procedure
16
7 Troubleshooting
17
8 Specifications
18
8.1 Nameplate
18
8.2 Input
18
8.3 Output
19
8.4 Control and Signalling
20
8.5 LEDs
21
Contents
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
1
8.7.1 Input Connection X1
22
8.7.2 Output Connection X2
22
8.7.3 Signal Connection X3
23
8.7.4 CAN-Bus Connection X4
23
8.8 CAN-Bus Interface
24
8.9 Mechanical Data
24
8.10 Dimensions
25
8.10.1 Front View
25
8.10.2 Side View
26
9 Appendix
27
9.1 Glossary
27
Index
30
Contents
VLT® ISD Power Supply Module Operating Instructions
2
MG75H102 - VLT® is a registered Danfoss trademark
1 General Information
1.1 Important Safety Warnings
WARNING
HIGH VOLTAGE
The ISD 410 servo system contains components which
operate at a high voltage when connected to the electrical
supply network. A hazardous voltage is present on the
servomotors, the power supply module and the
connection box whenever they are connected to the mains
network. There are no indicators on the servomotor that
indicate the presence of mains voltage. This indication is
provided on the connection box. Installation, commis-
sioning and maintenance may only be performed by
qualified staff. Incorrect installation, commissioning or
maintenance can lead to death or serious injury.
WARNING
UNINTENDED START
The ISD 410 servo system contains servomotors which are
connected to the electrical supply network and can start
running at any time. This may be caused by an external
switch, a CAN bus command, a reference signal, or clearing
a fault condition. Servomotors and all connected devices
must be in good operating condition. A deficient operating
condition may lead to death, serious injury, damage to
equipment or other material damage when the unit is
connected to the electrical supply network. Take suitable
measures to prevent unintended starts.
WARNING
DISCHARGE TIME
The servomotors, the connection box and the power
supply module contain DC link capacitors, that remain
charged for some time after the mains supply is switched
off at the power supply module.
To avoid electrical shock, fully disconnect the power
supply module from the mains before carrying out any
maintenance on the ISD servo system or its components.
Wait for at least the time listed below before carrying out
maintenance work:
Number
Minimum waiting time (discharge time)
1-60 servomotors
10 minutes
Note: High voltage may still be present even if the LED on the
ISD connection box is not lit!
Table 1.1 Discharge Time
1.2 Copyright
Disclosure, duplication and sale of this document, as well
as communication of its content, are prohibited unless
explicitly permitted. Infringement of this prohibition incurs
liability for damages. All rights reserved with regard to
patents, utility patents and registered designs.
ISD is a registered trademark.
1.3 Product Names and Trademarks
VLT® and ISD® are registered trademarks of Danfoss. All
other product names and trademarks used in this
documentation are trademarks or registered trademarks of
their respective titleholders.
1.4 Disclaimer
No liability is assumed for any damage or breakdown
resulting from:
•
Failure to observe the information in the
instruction manuals
•
Unauthorised modifications to the ISD servo
system or its components
•
Operator error
•
Improper work on or with the ISD servo system
or its components.
1.5 Approvals
1.5.1 ISD 410 Servomotor, ISD Encoder Box
and ISD Connection Box
Table 1.2 Approvals for the ISD 410 Servomotor, ISD Encoder Box
and ISD Connection Box
General Information
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
3
1 1
1.5.2 ISD Power Supply Module
R
C
US
Table 1.3 Approvals for the ISD Power Supply Module
1.6 Service and Support
Contact your local service representative for service and
support:
www.danfoss.com/Contact/Worldwide/
General Information
VLT® ISD Power Supply Module Operating Instructions
4
MG75H102 - VLT® is a registered Danfoss trademark
1
1
2.1 System Overview
130BC480.11
1
2
3
4
5
6
7
8
9
10
11
12
ISD Connection Box
Failure
Warning
Output (300V) OK
Stand-By
Output (90V) OK
Enable
Error
300V OK
90V OK
300V
Signal Outputs
10A
Signal Inputs
ISD Power Supply Module
AC/DC Power Supply 300VDC 8/10A
Run/Err
UZK
24V
Safe
Warn
Err
CAN-ID
5V
CAN
RS232
Service
Set
2
8
6
4
Safety I
Safety II
Fuse L I
CAN 1.In
CAN 2.In
CAN 3.In
CAN 4.In
CAN 5.In
X11
X12
X13
X14
X15
Fuse L II
CAN 1.Out
CAN 2.Out
CAN 3.Out
CAN 4.Out
CAN 5.Out
X21
X22
X23
X24
X25
0
Illustration 2.1 ISD Servo System with 3 Servomotors
Number
Description
Number
Description
1
Ethernet
7
Master encoder
2
Power supply module
8
Terminating resistor
3
Connection box
9
ISD servomotor
4
Master
10
Hybrid cable (DC & CAN)
5
CAN line
11
DC line
6
Encoder box
12
AC line
Table 2.1 Legend to Illustration 2.1
The servomotors are self-contained distributed drives,
which means that the drive electronics is housed together
with the motor in the same casing. The motion control
software also runs independently in the servomotor; which
reduces the load on the higher-level control system.
A master system controls the servomotors. In this system
servomotors operated in a DC group are controlled by a
master system.
Introduction
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
5
2 2
Several motors can be operated in a group using a hybrid
cable. This cable carries the DC supply voltage and the
CAN bus signals. The ISD 410 servo system is designed to
accommodate up to 60 ISD 410 servomotors and consists
of:
•
1 Power supply module
•
1 Connection box
•
1 Encoder Box
•
Servomotors
•
1 Master
•
Hybrid cables
NOTE
The ISD 410 servomotors cannot be used in other servo
systems from other manufacturers!
Motors from other manufacturers cannot be used in the
Danfoss ISD 410 servo system!
2.2 Terminology
ISD
Integrated Servo Drives
ISD servo system
Complete system including all components.
ISD master
Control system hardware
ISD master system
Control system hardware and software
ISD servo drive
ISD servomotor with hybrid cable
Table 2.2 Terminology
2.3 Purpose of the Operating Instructions
The purpose of these operating instructions is to describe
the Danfoss ISD power supply module exclusively in the
context of a Danfoss ISD 410 servo system.
These operating instructions contain information about:
•
Installation
•
Commissioning
•
Operation
•
Troubleshooting
•
Maintenance and repair
These operating instructions are intended for use by
qualified personnel. Read these operating instructions in
full in order to use the servo system safely and profes-
sionally, and pay particular attention to the safety
instructions and general warnings. These operating
instructions are an integral part of the ISD power supply
module. Keep these operating instructions available with
the servo system at all times.
Compliance with the information in the operating
instructions is a prerequisite for:
•
Trouble-free operation
•
Recognition of product liability claims
Therefore, read these operating instructions before
working with the power supply module!
The operating instructions also contain important service
information. The operating instructions should therefore be
kept close to the power supply module.
2.4 Additional Resources
Available documents for the ISD 410 servo system:
Document
Contents
VLT® ISD 410
Servomotor Operating
Instructions
Information about the commissioning
and operation of the servomotors
VLT® ISD Encoder Box
Operating Instructions
Information about the commissioning
and operation of the encoder box
VLT® ISD Connection Box
Operating Instructions
Information about the commissioning
and operation of the connection box
VLT® ISD Power Supply
Module Operating
Instructions
Information about the commissioning
and operation of the power supply
module
VLT® ISD 410 Design
Guide
Information about the construction
and commissioning of the ISD 410
servo system
Table 2.3 Available Documents for the ISD 410 Servo System
Technical literature for Danfoss drives is also available
online at http://www.danfoss.com/BusinessAreas/DrivesSo-
lutions/Documentations/Technical+Documentation.htm.
Firmware updates may be available. When firmware
updates are available, they can be downloaded from the
www.danfoss.com website. For further information see the
VLT® ISD 410 Design Guide.
Introduction
VLT® ISD Power Supply Module Operating Instructions
6
MG75H102 - VLT® is a registered Danfoss trademark
2
2
3.1 Symbols used in this Manual
The following symbols are used in this document.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
CAUTION
Indicates a situation that may result in equipment or
property-damage-only accidents.
NOTE
Indicates highlighted information that should be regarded
with attention to avoid mistakes or operate equipment at
less than optimal performance.
3.2 General
The following safety instructions and precautions relate to
the ISD 410 servo system. The number of servomotors in
the servo system is not significant.
Read the safety instructions carefully before starting to
work in any way with the servo system.
Pay particular attention to the safety instructions in the
relevant sections of this instruction manual.
Also observe the safety instructions and precautions in the
instruction manuals for the other system components.
WARNING
HIGH VOLTAGE
The ISD 410 servo system contains components which
operate at a high voltage when connected to the electrical
supply network.
A hazardous voltage is present on the servomotors, the
power supply module and the connection box whenever
they are connected to the mains network.
There are no indicators on the servomotor that indicate
the presence of mains voltage. This indication is provided
at the connection box. Installation, commissioning and
maintenance may only be performed by qualified staff.
Incorrect installation, commissioning or maintenance can
lead to death or serious injury.
WARNING
HAZARDOUS SITUATION
If the servomotor or the bus lines is/are incorrectly
connected, there is a risk of death, serious injury or
damage to the unit.
Always comply with the instructions within these operating
instructions, as well as national and local safety
regulations. Also read the operating instructions for the
other components of the servo system.
3.3 Safety Instructions and Precautions for
the ISD 410 Servo System
Read the safety instructions carefully before starting to
work in any way with the servo system. Compliance with
the safety instructions and precautions is necessary at all
times.
•
Orderly and proper transport, storage, fitting and
installation, as well as careful operation and
maintenance, are essential for the trouble-free
and safe operation of this servo system and its
components.
•
Only suitably trained and qualified staff may work
on the servo system and its components or in its
vicinity. See chapter 3.4 Qualified Personnel.
•
Use only accessories and spare parts approved by
the manufacturer.
•
Comply with the specified ambient conditions.
•
The information in these operating instructions
about the use of available components is
provided solely by way of examples of
applications and suggestions.
•
The plant engineer or system engineer is
personally responsible for checking the suitability
of the supplied components and the information
provided in this document for the specific
application concerned:
-
for compliance with the safety
regulations and standards relevant to
the specific application concerned.
-
for implementing the necessary
measures, changes and extensions.
•
Commissioning the servo system and its
components is not allowed until it has been
ascertained that the machine, system or plant in
which they are installed conforms to the statutory
provisions, safety regulations and standards that
apply in the country of use to that application.
Safety
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
7
3 3
Operation is allowed only in compliance with the
national EMC regulations for the application
concerned.
•
See the VLT® ISD 410 Design Guide for information
regarding EMC-compliant installation of the servo
system.
•
Compliance with the limit values specified by
national regulations is the responsibility of the
producer of the plant, system or machine.
•
Compliance with the specifications, connection
conditions and installation conditions in this
instruction manual is mandatory.
•
The safety regulations and safety provisions of
the country in which the equipment is used must
be observed.
•
Care must be taken to ensure that orderly
protective earthing of the equipment, which
protects the user against the supply voltage and
protects the power supply module against
overload, is performed in accordance with local
and national regulations.
•
Overload protection for the servomotor can be
programmed using the master system. For more
information, see Programming in the VLT® ISD 410
Design Guide.
•
Do not remove or replace the SD card on the
encoder box during operation, otherwise the
contents of the SD card could be destroyed.
Switch the encoder box off and wait 10 seconds
before removing the SD card.
WARNING
EARTHING HAZARD
For reasons of operator safety, the components of the
servo system must be earthed correctly in accordance with
national or local electrical regulations and the information
in these operating instructions. The earth leakage current
is greater than 3.5 mA. Improper earthing of the
servomotor may result in death or serious injury.
Operational Safety
•
Safety-related applications are allowed only if
they are explicitly and unambiguously mentioned
in the VLT® ISD 410 Design Guide. Otherwise they
are not allowed.
•
All applications that can cause hazards to people
or damage to property are safety-related
applications.
•
The stop functions implemented in the software
of the master system do not interrupt the mains
voltage supply to the power supply module and
are therefore not allowed to be used as safety
switches for the servo system.
•
The motor can be brought to a stop by a
software command or a zero speed setpoint, but
DC voltage remains present on the servomotor
and/or mains voltage in the power supply
module. If personal safety considerations (e.g. risk
of personal injury caused by contact with moving
machine parts after an unintended start) make it
necessary to ensure that an unintended start
cannot occur, these stop functions are not
sufficient. In this case the servo system must be
detached from the mains network or a suitable
stop function must be implemented.
•
When the servomotor is stopped, it may start up
again on its own if the circuitry of the servomotor
is defective or after the elimination of a
temporary overload, a problem with the supply
voltage or a problem with the servomotor. If
personal safety considerations (e.g. risk of
personal injury caused by contact with moving
machine parts after an unintentional start) make
it necessary to ensure that an unintended start
cannot occur, the normal stop functions of the
servomotor are not sufficient. In this case the
servo system must be disconnected from the
mains network or a suitable stop function must
be implemented.
•
The servomotor may start running unintentionally
during parameter configuration or programming.
If this can pose a risk to personal safety (e.g. risk
of personal injury due to contact with moving
machine parts), unintended motor starting must
be prevented, for example by using the Safe Stop
function or by safe disconnection of the
servomotors.
•
Do not disconnect the cables from the
servomotor while the servo system is connected
to mains voltage. Ensure that the mains supply is
disconnected and the required waiting time has
elapsed before disconnecting or connecting the
hybrid cable or disconnecting cables from the
connection box and/or the power supply module.
Safety
VLT® ISD Power Supply Module Operating Instructions
8
MG75H102 - VLT® is a registered Danfoss trademark
3
3
In addition to the L1, L2 and L3 supply voltage
inputs on the power supply module, the servo
system has other supply voltage inputs, including
external DC 24 V. Before commencing repair
work, check that all supply voltage inputs have
been switched off and that the necessary
discharge time for the intermediate circuit
capacitors has elapsed.
•
The supply of power to the servo system must be
switched off for repair work. Before disconnecting
or connecting the hybrid cable or disconnecting
cables from the connection box and/or the power
supply module, ensure that the mains supply is
disconnected and the necessary discharge time
has elapsed.
WARNING
DISCHARGE TIME
The servomotors, the connection box and the power
supply module contain DC link capacitors, that remain
charged for some time after the mains supply is switched
off at the power supply module.
To avoid electrical shock, fully disconnect the power
supply module from the mains before carrying out any
maintenance on the ISD servo system or its components.
Wait for at least the time listed below before carrying out
maintenance work:
Number
Minimum waiting time (discharge time)
1-60 servomotors
10 minutes
Note: High voltage may still be present even if the LED on the
ISD connection box is not lit!
Table 3.1 Discharge Time
CAUTION
Never connect or disconnect the hybrid cable to or from
the servomotor when voltage is present. Doing so will
damage the electronic circuitry. Observe the discharge
time for the DC link capacitors.
3.4 Qualified Personnel
Installation, commissioning and maintenance of the
ISD 410 servo system may only be carried out by qualified
personnel.
For the purposes of this document and the safety
instructions in this document, qualified staff are trained
staff who are authorised to fit, install, commission, earth
and label equipment, systems and circuits in accordance
with the standards for safety technology and who are
familiar with the safety concepts of automation
engineering.
Additionally, the personnel must be familiar with all the
instructions and safety measures described in these
operating instructions.
They must have suitable safety equipment and be trained
in first aid.
3.5 Due Diligence
The operator and/or fabricator must ensure that:
•
the servo system and its components are used
only as intended
•
the components are operated only in a perfect
operational condition
•
the operating instructions are always available
near the servo system in complete and readable
form
•
the servo system and its components are fitted,
installed, commissioned and maintained only by
adequately qualified and authorised personnel
•
these personnel are regularly instructed on all
relevant matters of occupational safety and
environmental protection, as well as the contents
of the operating instructions and in particular the
instructions it contains
•
the product markings and identification markings
applied to the components, as well as safety and
warning instructions, are not removed and are
always kept in a legible condition
•
the national and international regulations
regarding the control of machinery and
equipment, that are applicable at the place of use
of the servo system, are complied with
•
the users always have all current information
relevant to their interests about the servo system
and its use and operation
3.6 Intended Use
The components of the ISD servo system are intended to
be installed in machines used in commercial and industrial
environments.
To ensure that the product is used as intended, the
following conditions must be fulfilled before use:
•
Everyone who uses Danfoss products in any
manner must read and understand the
corresponding safety regulations and the
description of the intended use
•
Hardware must be left in its original state, which
means that no structural changes may be made
to the hardware
Safety
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
9
3 3
Software products may not be reverse-engineered
and their source code may not be altered
•
Damaged or faulty products may not be installed
or put into service
•
It must be ensured that the products are installed
in conformance with the regulations mentioned
in the documentation
•
Any specified maintenance and service intervals
must be observed
•
All protective measures must be complied with
•
Only the components described in these
operating instructions may be fitted or installed.
Third-party devices and equipment may be used
only in consultation with Danfoss
•
The documentation must be read completely and
correctly followed
The servo system may not be used in the following
application areas:
•
Areas with potentially explosive atmospheres
•
Mobile or portable systems
•
Floating or airborne systems
•
Inhabited facilities
•
Sites where radioactive materials are present
•
Areas with extreme temperature variations or in
which the maximum rated temperatures may be
exceeded
•
Under water
3.7 Foreseeable Misuse
Any use not expressly approved by Danfoss constitutes
misuse. This also applies to failure to comply with the
specified operating conditions and applications.
Danfoss assumes no liability of any sort for damage attrib-
utable to improper use.
Safety
VLT® ISD Power Supply Module Operating Instructions
10
MG75H102 - VLT® is a registered Danfoss trademark
3
3
The power supply module delivers the required DC 300 V
power supply to the ISD servo system. The DC 300 V
power supply is delivered to all servo drives installed in
the system via a hybrid cable. It is a controlled power
supply module, whereby the maximum rated output
current is 10 A, and the rated power is 3.0 kW. The LEDs
on the front of the unit display the operating status and
warnings.
CAUTION
The power supply module has an IP-rating of IP20. It is
only designed for use within a control cabinet. The unit
may be damaged if exposed to fluids.
Introduction
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
11
4 4
5 Mechanical Installation
5.1 Cooling
NOTE
•
To provide cooling airflow, mount the unit to a
solid flat surface or to the optional back plate.
•
Top and bottom clearance for air cooling must be
provided. Generally, 100-225 mm is required.
•
Improper mounting can result in over-heating
and reduced performance.
5.2 Mounting
•
Mount the unit vertically.
•
Ensure that the strength of the mounting location
will support the unit weight.
•
Mount the unit to a solid flat surface to provide
cooling airflow.
•
Improper mounting can result in over heating
and reduced performance.
•
Use the slotted mounting holes on the unit for
wall mounting.
Mechanical Installation
VLT® ISD Power Supply Module Operating Instructions
12
MG75H102 - VLT® is a registered Danfoss trademark
5
5
Mount the power supply module in the control cabinet
according to the following graphic.
•
All dimensions are in mm.
•
Recommended screws: Cylinder-head screw M5
130BD041.10
130
268
5.5
11
10
110
10
110
7
257
Illustration 5.1 Dimensions
Mechanical Installation
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
13
5 5
6 Electrical Installation
6.1 Earth (Grounding) Requirements
WARNING
GROUNDING HAZARD!
For operator safety, it is important to ground the power
supply module properly in accordance with national and
local electrical codes as well as instructions contained
within these operating instructions. Ground currents are
higher than 3.5 mA. Failure to ground the power supply
module properly could result in death or serious injury.
Electrical Installation
VLT® ISD Power Supply Module Operating Instructions
14
MG75H102 - VLT® is a registered Danfoss trademark
6
6
Illustration 6.1 Connections
1
Signal plug X3
2
Power input plug AC-In X1
3
CAN dip switch
4
Power output plug DC-Out X2
5
CAN bus plug X4
Table 6.1 Legend to Illustration 6.1
Electrical Installation
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
15
6 6
6.3 Installation Procedure
WARNING
HIGH VOLTAGE!
The power supply module contains high voltage when
connected to AC mains input power. Installation, start up,
and maintenance should be performed by qualified
personnel only. Failure to perform installation, start up, and
maintenance by qualified personnel could result in death
or serious injury.
WARNING
INCORRECT VOLTAGE!
Connecting the incorrect voltage to the power supply
module can result in death or serious injury and damage
to the unit.
•
Only connect voltages of AC 400-480 V, 50/60 Hz,
3-phase and PE.
•
Only TN mains are allowed.
1.
Wire and connect the power input plug to “AC-In:
-X1”
PE
AC-In
L1
L3
L2
130BD043.10
Illustration 6.2 Power Input Plug
2.
Wire and connect the power output plug to “DC-
Out: -X2”
130BD044.10
PE
+Uo.1
+Uo.2
-Uo.1
-Uo.2
Illustration 6.3 Power Output Plug
3.
Wire and connect the signal plug to “Signals: -X3”
to enable the hardware.
The pin assignment is detailed in chapter
8.7.3 Signal Connection X3.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
130BD045.10
Illustration 6.4 Signal Plug
4.
Wire and connect the CAN bus plug to “CAN: -X4”
CAN-
GND
CAN
_L
(NC)
CAN
_H
(CAN
+5V)
130BD046.10
Illustration 6.5 CAN Bus Plug
5.
Ensure that the CAN dip switch is set to
“500 kbit/s” (default)
-
-
-
-
on
on
1
2
3
4
on
on
-
-
on
on
-
-
on
on
CAN Node-Id
CAN Bit Rate
0x78 *)
0x79
0x7A
0x7B
125 kbit/s
250 kbit/s
500 kbit/s *)
1 Mbit/s
CAN-Reset Button
*) = default
130BD047.10
Illustration 6.6 CAN Dip Switch
Electrical Installation
VLT® ISD Power Supply Module Operating Instructions
16
MG75H102 - VLT® is a registered Danfoss trademark
6
6
Green LED twinkling
No output voltage
Signal input "Enable"
not active
Apply 10-28 V to signal
input "Enable"
Also possible: connect
12 V auxiliary voltage
directly at the signal
connector (X3).
2
Green LED blinking
Reduced output voltage
Signal input "300V" not
active
Apply 10-28 V to signal
input "300 V", if full
output voltage
(Setpoint Uo nominal) is
desired
Also possible: connect
12 V auxiliary voltage
directly at the signal
connector (X3).
3
No LED active
No output voltage
• No AC input voltage
• Phases missing
Check AC input voltage
If the power supply
module's external fuse
is blown, there is a
failure in the power
supply module. Send
the power supply
module to Danfoss.
4
Red LED blinking
Output voltage possibly
reduced
Output current too high Check if output current
is higher than current Io
limitation
–
5
Red LED blinking
Output voltage possibly
reduced
• Fan blocked
• Fan speed reduced
• Check if fan is
mechanically locked,
e.g. by parts
reaching inside the
power supply (fan)
• Send the power
supply module to
Danfoss for the fan
to be replaced
If the fan is blocked, the
output current is
automatically limited to
4 A.
6
Red LED blinking
Output voltage possibly
reduced
Internal heatsink
temperature too high
• Check if air inlet and
outlet are free
• Check if the ambient
temperature is too
high
If the temperature is
above "Warning Level",
the output current is
limited to 4 A.
7
Red LED active
No output voltage
Internal heatsink
temperature too high
• Check if air inlet and
outlet are free
• Check if the ambient
temperature is ≤ the
rated ambient
temperature of the
specification
If temperature is above
"Fault Level", the output
is switched off
8
Red LED active
No output voltage
Internal failure
Contact Danfoss-Service
If the external fuse is
broken, do not try to
return the mains
voltage to the power
supply module.
Table 7.1 Troubleshooting
Troubleshooting
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
17
7 7
ISD Power Supply Module
Made in Germany
Input: 380...480VAC, 3PH, 50-60Hz / max. 6A
Power Supply BSAB3000-480T-300C-1
Input Fuses: external fuses 3 x 6.3A required
Output: 90 / 300VDC / max. 10A
File: 220234
PART NO: 175G7800
SERIAL NO : 000101M212
*175G700000101M212*
1
2
3
4
5
Illustration 8.1 Nameplate
1
Supply voltage
2
Fuses
3
Output voltage
4
Part number
5
Serial number
Table 8.1 Legend to Illustration 8.1
8.2 Input
Definition
Min.
Type
Max.
Unit
Condition
Remark
Rated input voltage range
380
400
480
VAC
3 Phase + PE,
50/60 Hz
+/- 10%
Input current
–
–
6
Arms
–
Each phase
Fuses
External 3-pole line safety switch, 3 x 6.3 A
–
–
Inrush current
–
–
20
A
After 1 ms
–
Holdup time
5
–
–
ms
At Po nominal
Until output < 90% Uo nominal
Power factor (Pactive / Papparent)
90
94
–
%
At
Ui = AC 400 V;
Uo = DC 300 V;
Io = 10 A
–
Line frequency
47
–
63
Hz
–
–
Table 8.2 Input Data
Specifications
VLT® ISD Power Supply Module Operating Instructions
18
MG75H102 - VLT® is a registered Danfoss trademark
8
8
(0% / 100%
nominal current)
0
-1.5 (default)
-7.5
%
–
Adjustable in 16
steps via
CANopen
interface
Ripple
–
–
1
Vpp
BW = 20 MHz
–
Rated power
Po nominal
–
3000
–
W
–
–
Rated current
Io nominal
–
10
–
A
Control input “10
A” active
–
Current limitation
“10 A”
10.1
10.2
10.5
A
Control input “10
A” active
–
Current limitation
“reduced”
7.5
7.8
7.9
A
–
Control input “10
A” open
Current limitation
at “thermal
warning level”
3.5
–
4.5
A
–
If fan blocked or
heat sink
temperature too
high
Short circuit
rigidity
Yes, continuously
–
–
Efficiency
92
93
–
%
–
–
No load input
power
–
15
–
W
–
–
Parallel operation
Up to 3 units
–
Load sharing
supported by
“downslope”
characteristic
Potential
conditions
Output is floating
Test voltage > DC
1000 V output
against PE
Normally 1 pole of
the output will be
grounded in the
application
Ext. allowed
capacity at Uo
0
–
>15
mF
Output stable
–
Over-voltage
protection
(normal) OVP
305
–
335
VDC
Average value
Non-latching
Table 8.3 Output Data
Specifications
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
19
8 8
8.4 Control and Signalling
Definition
Min.
Type
Max.
Unit
Condition
Remark
Signal output
“300V_OK” (X3:3)
Optocoupler output
Active if control loop Uo with setpoint Uo nominal (300 V) is
operating
Signal output
“Error” (X3:5)
Optocoupler output
Active on failure (error)
All optocoupler
outputs active
–
–
5
V
At 10 mA
Current limitation with PTC
(short-circuit proof up to
28 V)
All optocoupler
outputs inactive
–
–
0.1
mA
At max. 35 V
–
Signal input
“Enable” (X3:7)
Optocoupler input
• Output switched on when active
• Output switched off (standby) when inactive
Signal input
“300V” (X3:9)
Optocoupler input
• Setpoint Uo nominal (300
V) when active
• Setpoint Uo reduced (90 V)
when inactive
Redundant internal circuit
ensures Uo <102 V also in
case of a single internal
component fault
Signal input
“10A”, output
current limitation
limitation setting
Optocoupler input
• Setpoint Io limited nominal
(10.2 A) when active
• Setpoint Io limited reduced
(7.8 A) when inactive
All optocoupler
inputs active
10
–
28
V
max. 10 mA
–
All optocoupler
inputs inactive
–
–
5
V
–
–
Current on
auxiliary output
12 V (X3:13,
X3:14)
–
–
10
mA
Sufficient for supplying the 3 signal inputs
Table 8.4 Control and Signalling
Specifications
VLT® ISD Power Supply Module Operating Instructions
20
MG75H102 - VLT® is a registered Danfoss trademark
8
8
ISD Power Supply Module
Warning
Failure
Output (300V) OK
Output (90V) OK
Stand-By
90V OK
300V OK
Error
Enable
300V
10A
Signal Outputs
Signal Inputs
AC/DC Power Supply 300VDC 8/10A
Illustration 8.2 LEDs
LED Definition
Type
Condition
Remark
1
Failure signalling
Red LED on front of
module
• Continuously on during failure (output is switched off)
• Blinking at warning level (e.g. fan at too low speed, current limit active, heatsink
temperature reached first limit, input voltage too low etc.)
2
OK signalling
Green LED on front of
module
• Continuously on if output voltage Uo at Uo nominal (300 V) and ok
• 50 % blinking if Uo at Uo reduced (90 V) and ok
• Twinkling during standby
3-5
Signalling of all
optocoupler
outputs
Orange LED for each
on front of module
–
LED on when active
6-8
Signalling of all
optocoupler inputs
Orange LED for each
on front of module
–
LED on when active
Table 8.5 Legend to Illustration 8.2
Specifications
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
21
8 8
At +70 °C derating to 50% Io
(in range +50 to 70 °C linear
declining)
Humidity
–
–
95
%
Non-condensing
–
Cooling
Internal fan, temperature controlled
Air flow from bottom to top.
Do not block air intake and allow 100-255 mm air cooling
space at top and bottom of unit.
Protection
category
IP20
Standard
Protection class
1 (with PE-connection)
–
–
Designed
according to
safety standards
CSA C22.2 No. 60950-1:2003 and UL60950-1:2003 and/or IEC 60950-1:2001 (1st Edition) and/or EN 60950-1:2001 and/or
DIN/EN 60950-1:2003 and EN 60950-1 second edition 2006 UL508:2005 and CSA22.2-107. EN 60204:1998
Approvals
CE, CSA
Table 8.6 Environmental Data
8.7 Connections
8.7.1 Input Connection X1
4-pole (coded) Phoenix PCV 4 / 5-G-7.62 with mating plug
(included) PC 5 / 4-STF-7.62 (gauge up to 6 mm2)
PE
L2
L1
L3
1
2
3
4
130BD050.10
Illustration 8.3 Input Connection X1
8.7.2 Output Connection X2
5-pole, can also be used for looping through (max. 20 A).
Phoenix PCV 4 / 5-G-7.62 with mating plug (included)
PC 5 / 5-STF-7.62 (gauge up to 6 mm2)
+Uo.1
PE
+Uo.2
-Uo.1
-Uo.2
1
2
3
4
5
130BD051.10
Illustration 8.4 Input Connection X2
Specifications
VLT® ISD Power Supply Module Operating Instructions
22
MG75H102 - VLT® is a registered Danfoss trademark
8
8
8.7.3 Signal Connection X3
14-pole Phoenix MSTB 2.5 / 14-GF-5.08 with mating plug
(included) MSTB 2.5 / 14-STF-5.08
90 V OK+
300 V OK+
Error+
+12 V in
+12 V in
+12 V in
90 V OK–
300 V OK–
Error–
GND in
GND in
+12 V out
GND in
GND out
Internal Auxiliary Supply (12 V)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Optocoupler active if output
(Not valid for ISD 410)
voltage Uo reduced (90 V) is OK
Optocoupler active if output
voltage Uo nominal (300 V) is OK
Optocoupler active in case of
any failure / error
Output will be switched on if
10-28 V applied here
Setpoint Uo nominal (300 V) if
10-28 V applied here, otherwise
Uo reduced (90 V)
Setpoint Io limited nominal (10.2 A)
if 10-28 V applied here, otherwise
Io limited reduced (7.8 A)
This potential-free 12 V auxiliary
voltage can be used to supply the
above mentioned optocoupler
inputs
130BD052.10
Illustration 8.5 Signal Connection X3
Here is an example of how to wire signal plug X3 in order
to enable the hardware:
•
Pin 13 to 11 to 9 to 7
•
Pin 14 to 12 to 10 to 8
WARNING
HIGH VOLTAGE!
By using the above detailed wiring example the DC 300 V
output voltage is immediately available once the AC 400 V
supply voltage is connected.
Use a relay between pins 9 and 7 to control the output
voltage. The DC 300 V output voltage is enabled when the
relay is closed.
8.7.4 CAN-Bus Connection X4
5-pole Phoenix MSTBA 2.5 / 5-G-5.08 with mating plug
(included) MSTB 2.5 / 5-ST-5.08
CAN_GND
(NC)
CAN_L
CAN_H
(CAN +5 V)
1
2
3
4
5
max. 20 mA
external load
130BD053.10
Illustration 8.6 CAN-Bus Connection X4
Specifications
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
23
8 8
8.8 CAN-Bus Interface
The CAN DIP-switch is located in the underside of the
power supply module.
-
-
-
-
on
on
on
on
-
-
on
on
-
-
on
on
CAN Node-Id
CAN Bit Rate
0x78 *)
0x79
0x7A
0x7B
125 kbit/s
250 kbit/s
500 kbit/s *)
1 Mbit/s
CAN-Reset Button
DIP switches
*) = default
1
2
3
4
130BD054.10
Illustration 8.7 CAN DIP-Switch
Definition
Description
Condition
Potential
relation
CAN-Bus is insulated
Test voltage DC 500 V
CAN against PE
CAN-Baud
rate
125, 250, 500 (default),
1000 kbit/s
Switchable via 2 DIP-
switches
CAN-ID
0x78 (default), 0x79,
0x7A, 0x7B
Switchable via 2 DIP-
switches
Protocol
CANopen (specified by
CAN in Automation
CiA)
According to CiA 401
“Generic I/O”
Table 8.7 CAN-Bus Interface Data
8.9 Mechanical Data
Housing
Steel and aluminium for wall mounting
Dimensions (H x W x D)
Approx. 268 x 130 x 205 mm
Weight
5.5 kg
Mounting
On rear side
Connector arrangement
On underside
Table 8.8 Mechanical Data
Specifications
VLT® ISD Power Supply Module Operating Instructions
24
MG75H102 - VLT® is a registered Danfoss trademark
8
8
8.10.1 Front View
All dimensions are in mm.
130BD056.10
130
254
Illustration 8.8 Front View
Specifications
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
25
8 8
8.10.2 Side View
All dimensions are in mm.
130BD057.10
202.5
205
68
2
5
2
5.2
1
54
2
68
Illustration 8.9 Side View
Specifications
VLT® ISD Power Supply Module Operating Instructions
26
MG75H102 - VLT® is a registered Danfoss trademark
8
8
The A side is the shaft side of the motor.
Ambient temperature
The temperature in the immediate vicinity of the servo
system or component.
Axial force
The force in newton-metres acting on the rotor axis in the
axial direction.
BCD
Binary-coded decimal
Bearings
The ball bearings of the servo drive.
B flange
The rear side of the servomotor with the plug-and-socket
connectors.
BiSS
Bi-directional Synchronous Serial
Brake
Power-off brake of the ISD servomotor, on the A side of
the motor.
CAN
Controller Area Network
CANopen DS301
A standard that specifies the application layer and
communication profile.
CANopen DS402
An object-based CAN standard that specifies the device
profile for drives and motion control.
CANopen DS406
An object-based CAN standard that specifies the device
profile for encoders.
CE
European test and certification mark.
Clamping set
A mechanical device, which, for example, can be used to
secure gears to a motor shaft.
CoDeSys
Controller Development System; a development
environment for programming controller applications,
based on IEC 61131-3 and developed by 3S-Smart Software
Solutions GmbH.
Connection box
The connection box provides the link between the power
supply module and the servo drives.
Connector (M23)
Servomotor connector.
Cooling
ISD servo drives are cooled by convection, which means
without fans.
CRC
Cyclic Redundancy Check
CSA
Canadian test and certification mark.
DC link
Each servomotor has its own DC link, consisting of
capacitors.
DC link voltage
A DC voltage shared by several ISD servomotors connected
in parallel.
DC voltage
A direct constant voltage.
DSP
Digital signal processor; processor IC on an ISD control
board.
Encoder box
The encoder box allows external encoder signals to be
sent to the servo drives over the CAN bus with high
precision.
Feed cable
Hybrid connection cable between connection box and
servomotor, with a connector.
Appendix
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
27
9 9
Feedback systems for servomotors in general.
Fieldbus
Communication bus between controller and servo axis; in
general between controller and field nodes.
Firmware
Software in the unit; runs on the control board.
Flash
Memory IC on the ISD control board; a form of EPROM.
Function block
Device functionalities are accessible via CoDeSys.
Gear ratio
The speed ratio of the input pinion and the output shaft of
the gear unit.
Gear unit
External gear unit used to change the output shaft speed
and the torque on the motor shaft.
Hole circle
The hole patterns of the ISD and IEC flanges.
IEC flange
Industry-standard flange
Installation elevation
Installation elevation above normal sea level, typically
associated with a derating factor.
ISD
Integrated servo drive, integrated servomotor solution.
ISD flange
The standard flange for ISD servo drives; larger than the
IEC flange.
ISD servomotor
Designates the ISD servomotor with hybrid cable.
Loop cable
Hybrid connection cable between two servomotors, with
two connectors.
M12 connector
Input connector for connecting the sensor on the B side of
the servomotor.
Motor shaft
Rotating shaft on the A side of the servomotor, typically
without a key groove.
Multi-turn encoder
Describes a digital absolute encoder, in which the absolute
position remains known after several revolutions.
NMT
Network Management
PELV
Low-voltage directive regarding voltage levels and
distances between lines.
PDO
Process Data Object (see CANopen DS301).
Planetary gear
A specific type of gearing, typically used with servomotors.
Power-off principle
The brake is normally engaged. It is released by applying a
voltage (safety function).
Power supply module
The power supply module provides a regulated DC 300 V
from AC 400 V.
QEP
Quadrature Encoder Pulse
Radial force
The force in newton-metres acting at 90° to the
longitudinal direction of the rotor axis.
Resolver
A feedback device for servomotors, typically with two
analog tracks (sine and cosine).
Safety (STO)
A servomotor safety circuit that switches off the voltages
of the driver components for the IGBTs.
Scope
Used for diagnosis. Enables internal signals to be depicted.
SD Card
Secure Digital Card for encoder box.
SDO
Service Data Object (see CANopen DS301).
Appendix
VLT® ISD Power Supply Module Operating Instructions
28
MG75H102 - VLT® is a registered Danfoss trademark
9
9
A segment refers to a movement within a curve.
SIL 2
Safety Integrated Level II.
Single-turn encoder
Describes a digital absolute encoder, in which the absolute
position for one revolution remains known.
SSI
Synchronous Serial Interface
Toolbox
A software tool used for parameter setting and diagnostics
of ISD servomotors, the ISD connection box and the ISD
encoder box.
Appendix
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
29
9 9
Discharge Time........................................................................................ 3
Documents................................................................................................ 6
Due Diligence........................................................................................... 9
E
Earth Requirements............................................................................. 14
Electrical Installation........................................................................... 15
F
Forseeable Misuse................................................................................ 10
G
Glossary.................................................................................................... 27
Grounding Requirements.................................................................. 14
H
High Voltage............................................................................................. 3
I
Installation, Electrical.......................................................................... 15
Intended Use............................................................................................ 9
Introduction........................................................................................... 11
ISD Servo System.................................................................................... 5
M
Mounting................................................................................................. 12
N
Nameplate............................................................................................... 18
O
Operational Safety.................................................................................. 8
Q
Qualified Personnel................................................................................ 9
S
Safety
Safety...................................................................................................... 7
Discharge Time.................................................................................... 3
High Voltage........................................................................................ 3
Instructions........................................................................................... 7
Unintended Start................................................................................ 3
Warnings................................................................................................ 7
Safety, Operational................................................................................. 8
Symbols...................................................................................................... 7
T
Trademarks................................................................................................ 3
U
Unintended Start..................................................................................... 3
V
Voltage Warning..................................................................................... 3
W
Warning
Discharge Time.................................................................................... 3
High Voltage........................................................................................ 3
Unintended Start................................................................................ 3
Index
VLT® ISD Power Supply Module Operating Instructions
30
MG75H102 - VLT® is a registered Danfoss trademark
VLT® ISD Power Supply Module Operating Instructions
MG75H102 - VLT® is a registered Danfoss trademark
31