Alula RE301 Quick Start Manual
Read Online
Read the Alula RE301 Quick Start Manual online using the built-in PDF viewer.
Text of the manual
Door Window Sensor is a full-featured security transmitter
with industry-leading wireless range and battery life. It is
typically used to sense opening and closing of doors and
windows, but can secure just about anything using its two
external contact zones. It will alarm when the magnet is pulled
away from the sensor or when an external contact is opened.
Features
• Industry-leading wireless range and battery life
• One door window zone and two external contact zones
• Secure encrypted wireless transmissions
• 5 year warranty
Enroll zones by placing panel into wireless enrollment mode.
ESN IDs
• Reed Switch Zone 0 = ESN ends in “0” and is labeled
on the DWS battery bucket
• External Contact Zone 1 = Same as Reed Switch Zone
with last digit replaced by a “1”
• External Contact Zone 2 = Same as Reed Switch Zone
with last digit replaced by a “2”
Install by mounting the sensor and magnet on a door or window
using the mounting screw locations. Make sure to align the
alignment marks on the sensor and magnet when mounting.
Additionally, the sensor can be used with up to two external
contacts.
External Contacts
• Use normally-closed contacts because the door
window sensor will transmit an alarm when it sees an
external contact open
• Do not use end-of-line resistors
• Activate only the zones you need
Mounting Screw Holes
Use the panel installation guide to verify proper system setup.
RE301 Door Window Sensor
DSC® Compatible
I
N
S
T
A
L
L
G
U
I
D
E
I
Resolution Compatibles
Enroll Reed Switch
• Remove battery tab and trip tamper to enroll
• Sensor ID for reed switch ends in “0” and is labeled on
the DWS battery bucket
Enrolling External Sensors
• Trip external sensors to enroll
• External 1 has same ID except it ends in “1”
• External 2 has same ID except it ends in “2”
• Trip only the zones on the DWS you want to enroll
• The two external contact zones must be “activated” in
order to report. Short zones while installing battery to
activate.
all-guide
s.com
3M™ VHB™ Tape works great if the surface is properly prepared and firm pressure is
applied for over 10 seconds.
Surface Preparation
• Clean the surface
• Ensure the mounting surface temperature is above 50 °F
Wireless performance is optimized when mounted near the top of the door in a vertical
orientation.
OK
BEST
WRONG
Wire an external contact by securing one wire to either the external 1 or external 2 port
and the other wire to the common port. If both external contacts are used two wires
will be inserted into the common port.
Battery
-
+
Cover Tamper
rnal 1
m
nal 1
Magnetic Reed Switch
External 1 Terminal
External 2 Terminal
Center Common
Terminal
Tamper
Magnet Gap Specifications
X Axis
Z Axis
Non-Ferromagnetic Surface
Nominal Mounting Distance
X Axis - Make
Break
Y Axis - Make
Break
Z Axis - Make
Break
1.00 inches (2.5 cm)
1.10 inches (2.8 cm)
1.30 inches (3.3 cm)
2.40 inches (6.1 cm)
2.55 inches (6.5 cm)
1.20 inches (3.0 cm)
1.35 inches (3.5 cm)
Ferromagnetic Surface
Nominal Mounting Distance
X Axis - Make
Break
Y Axis - Make
Break
Z Axis - Make
Break
0.50 inches (1.2 cm)
0.60 inches (1.5 cm)
0.65 inches (1.7 cm)
1.70 inches (4.3 cm)
1.75 inches (4.5 cm)
1.05 inches (2.7 cm)
1.10 inches (2.9 cm)
Y Axis
Specifications subject to change without notice
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.25 x 1.40 x 1.05 inches (8.3 x 3.6 x 2.7 cm)
1.90 ounces (54 grams)
Four #6 screws (provided)
Environmental
Operating Temperature
Maximum Humidity
32° to 120 °F (0° to 49 °C)
85% non-condensing relative humidity
Sensor Specifications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Max Wire Length on
External Contacts
433.92 MHz
One Panasonic® CR123A
10 to 15 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Cover Tamper, Low Battery, Supervision
7.5 feet
Certification
RE301
FCC, IC
Specifications
47-0004-03 • REV C • 2018-12-11
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
01
WARRANTY
Alula will replace non-portable products that are defective in their
first five (5) years, and portable products that are defective in their
first two (2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE301
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE301
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
“DSC” is a trademark owned by TYCO.
Alula products will function with DSC systems. However, no Alula
product is produced by, endorsed by, or is officially associated with
DSC. Alula recommends verifying proper enrollment and operation,
per control panel installation instructions, at installation.
3M and VHB are trademarks owned by 3M Company.
Panasonic is a trademark owned by Panasonic Corporation.