DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 3 INDEX 1 1 INTRODUCTION ...................................................................................................................... 4 2 TECHNICAL SUMMARY ........................................................................................................ 4 2.1 BRIEF DESCRIPTION .................................................................................................................. 4 2.2 APPLICATIONS .......................................................................................................................... 4 2.3 FEATURES AND BENEFITS ................................................................................................. 4 2.4 TECHNICAL SPECIFICATIONS ........................................................................................... 4 3 INSTALLATION........................................................................................................................ 6 4 OSD2892 FRONT AND REAR PANELS................................................................................. 7 4.1 FRONT PANEL ....................................................................................................................... 7 4.2 REAR PANEL ............................................................................................................................ 7 5 POWER SUPPLY CONNECTIONS ........................................................................................ 7 6 LED INDICATORS ................................................................................................................... 8 7 FITTING SFP CONNECTORS ................................................................................................ 9 8 CLI OVERVIEW ..................................................................................................................... 10 8.1 CONNECT TO CLI .................................................................................................................... 10 8.2 CLI COMMAND FOR IP CONFIGURATION ................................................................................. 11 GUI OVERVIEW ................................................................................................................................. 13 8.3 DEFAULT SETTING................................................................................................................... 13 8.4 LOG INTO THE SWITCH ............................................................................................................ 13 8.5 GUI OVERVIEW ....................................................................................................................... 13 8.6 IP CONFIGURATION ................................................................................................................. 14 8.7 USERS AUTHENTICATION ........................................................................................................ 15 8.8 SAVE CONFIGURATION TO START-UP ...................................................................................... 16 8.9 PORT SPEED SETTING .............................................................................................................. 16 9 WARRANTY ............................................................................................................................ 17 9.1 WARRANTY PERIOD .......................................................................................................... 17 9.2 REPAIRS ................................................................................................................................ 17 9.2.1 WARRANTY REPAIRS .................................................................................................... 17 9.2.2 OUT-OF-WARRANTY REPAIRS .................................................................................... 17 9.2.3 SITE REPAIRS .................................................................................................................. 17 9.2.4 EXCLUSIONS ................................................................................................................... 17 FIGURE 1: FRONT PANEL .................................................................................................................... 7 FIGURE 2: REAR PANEL ...................................................................................................................... 7 FIGURE 3: POWER CONNECTION ...................................................................................................... 7 FIGURE 4: FITTING/REMOVING SFP CONNECTORS ..................................................................... 9 TABLE 1: TECHNICAL SPECIFICATIONS ......................................................................................... 5 TABLE 2: LED FUNCTION ................................................................................................................... 8

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 4 1 INTRODUCTION Thank you for choosing the OSD2892 40-Port (36x1G + 4x10G) L2/L3 Managed Ethernet Switch. This Quick Start Guide is designed to guide you through the installation and basic software functions. 2 TECHNICAL SUMMARY 2.1 BRIEF DESCRIPTION The OSD2892 is an L2/L3 managed 36 port 10/100/1000BASE-T and 4 port 10G SFP Ethernet Switch. Please see OSD2892 datasheets for options available. 2.2 APPLICATIONS ▲ Any network utilizing a mix of copper and fiber ▲ Industrial IP communications ▲ Self-healing Gigabit Ethernet backbone networks ▲ Four 10G SFP trunk/uplink ports 2.3 FEATURES AND BENEFITS ▲ Complies with IEEE802.3i/802.3u/802.1ab 10/100/1000Base-T, IEEE802.3z 1000Base- LX, IEEE802.3ae 10GBaseXX standards ▲ Supports RSTP/STP/ ITU-TG.8032 Ethernet Ring Protection Switching for Ethernet redundancy Supports Loop Protection ▲ IP Multicast Filtering through IGMP Snooping V2 ▲ Supports port-based VLAN and Private VLAN ▲ QoS with eight priority levels ▲ Virtual USB console, Telnet, SNMP V1, V2c & V3 and Web Browser ▲ Full wire-speed forwarding rate ▲ Supports IEEE802.1x Security ▲ IEEE802.3ab Link Layer Discovery Protocol ▲ Static and LACP link Aggregation ▲ Port speed control and Port mirroring ▲ 1000Mbps-Full-duplex, 10/100Mbps- Full/Half-duplex, Auto-Negotiation, Auto- MDI/MDIX ▲ Operates over the temperature range of -20 to +60ºC ▲ Redundant DC powering and optional redundant AC powering ▲ Optional IEEE 802.3af/at PoE (OSD2892P) ▲ System log and remote firmware upgrading ▲ Intelligent thermal protection ▲ L3 compliant switch, including functions like: Universal Plug and Play (UPnP), IPv4/IPv6 L3 static routing, RFC2328 OSPFv2 dynamic routing,RFC-1812 L3 checking (version, IHL, checksum), etc.

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 5 2.4 TECHNICAL SPECIFICATIONS TABLE 1: TECHNICAL SPECIFICATIONS SPECIFICATION PERFORMANCE Electrical Data Interface IEEE802.3i/802.3u/802.3ab, 10/100/1000Base-T Ethernet Electrical Data Connector RJ45 on the fixed copper ports for OSD2892 and OSD2892P OSD2892P PoE IEEE802.3af: 47 to 55VDC @ 0.35Amp maximum IEEE802.3at: 47 to 55VDC @ 0.70Amp maximum Configuration Connector Mini USB console Port Alarms Four: 2 for Power Supply Status, 2 user definable via the GUI Alarm Interface 4 opto-isolated relay drivers via two 4-way 3.5mm terminal blocks Control System reset Optical Port Connector Dual LC on 2-fiber SFP modules or SC on 1-fiber SFP modules Trunk/Uplink Ports Optical Interface IEEE802.3ae for 10GBASE-SR (MM: 300m), 10GBASE-LR (SM: 10km), 10GBASE_ER (SM: 40km), 10GBASE_ZR (SM: 80km), IEEE802.3z 1000Base-Lx/Sx Operating Mode Half or full duplex for 10/100 Full duplex for 1G, 2.5G and 10G Store-and-Forward Half-duplex back-pressure and IEEE802.3x full-duplex flow control Indicators 1 x power 36 x 10/100/1000Base-T: Link Activity 36 x 10/100/10001000Base-T: Speed 4 x 10G Link/Activity/Speed 36 x 10/100/1000Base-T: PoE (OSD2892P only) SFP Options See OSD Datasheets #1010000X and #10210G00X for full details on available optical SFP modules Operating Temperature -20°C to +60°C Relative Humidity 5 to 95% non-condensing Power Requirements OSD2892DC 10 to 36VDC @ 45VA Max via one 4-way 5.08mm terminal block OSD2892AC 90 to 264VAC @ 50VA Max via integrated IEC power inlet module OSD2892DAC 90 to 264VAC @ 55VA Max via two integrated IEC power inlet modules OSD2892P 47-57 VDC @ 50VA Max (without PoE) & @ 450VA Max (with PoE0 via one 4-way 5.08mm terminal block OSD2892P PoE Power Budget 750W maximum Dimensions of Module (mm) 440W x 300D x 44H Weight (kg) 4.9 for OSD2892, 5.1 for OSD2892P 102289205

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 6 3 INSTALLATION ELECTROMAGNETIC COMPATIBILITY WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. OPTICAL OUTPUT OPERATION WARNING: Laser Safety: Class 1 Laser Product (SFP) per IEC 60825-1:2014 standard. Class 1 The OSD2892 is a Class 1 laser product when SFP are fitted PRECAUTIONS ▲ All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures during servicing of equipment ▲ Areas where laser products are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area. ▲ All laser apertures should be covered by protective covers when not connected to optical fibers. Never leave outputs uncovered. ▲ Laser equipment should be positioned above or below eye level where possible. Apertures should be positioned away from personnel. ▲ Protective eyewear should be worn in the vicinity of laser equipment.

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 7 4 OSD2892 FRONT AND REAR PANELS 4.1 FRONT PANEL FIGURE 1: FRONT PANEL 1. PSU1 Status LED 2. PSU2 Status LED 3. Status LED 4. USB Console Port 5. View LED Mode button 6. View mode LEDs indicators 7. 36 x 10/100/1000M COPPER ports with Link/Speed/Status LED 8. 4 x 10G Trunk/Uplink SFP ports with Link/Speed/Status LED 9. Reset Button 4.2 REAR PANEL FIGURE 2: REAR PANEL 10. PSU Alarm Output connector 11. Programmable Alarm Output Connector 12. Earth/Ground screw 13. PSU 1 Power Supply Input/Fuse/Switch 5 Power Supply Connections There are various power options for the OSD2892. Refer to Table 1 Power Options (Figure 3 has OSD2892AC version shown). Power is connected to the rear of the unit. Fuse: 1A 250V Anti-Surge, 5x20mm. FIGURE 3: POWER CONNECTION 1 2 3 10 11 12 13 4 5 6 7 8 9

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 8 6 LED Indicators TABLE 2: LED FUNCTION LED Function PSU 1 • Red – PSU 1 Not connected or faulty • Green – PSU 1 On PSU 2 • Red – PSU 2 Not connected or faulty • Green – PSU 2 On • Off – PSU 2 not available/fitted Status • Red – Standby/Initialization Mode • Green – Normal status View Mode LED Indicators Controlled by View LED Mode Button. Pressing the Mode button cycles the Copper Port Status LED indication. Speed Mode  Duplex Mode  Status Mode  Reserved Copper Port Status LED The Copper Port Status LED will indicate different information. Speed Mode: • Green – 1Gbps • Yellow – 100MBps • Off – No Connection • Blinking – Traffic Duplex Mode: • Green – Full Duplex • Yellow – Half Duplex • Off – No Connection Status Mode: • Green – Connection established • Off – No Connection Fiber Port Status LED The Fiber Port Status LED will indicate different information. Speed Mode: • Green – 1Gbps or 10Gbps • Yellow – 100MBps • Off – No Connection Duplex Mode: • Green – Full Duplex • Off – No Connection Status Mode: • Green – Connection established • Off – No Connection

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 9 7 Fitting SFP Connectors Care should be taken when inserting/removing the SFP connectors from the SFP port as SFP modules are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) precautions should be taken when installing. Ensure that the SFP is fully engaged and latched into position. Inserting SFP – Ensure that the SFP lever is in the locked position and insert into appropriate SFP port. Gently push the SFP until it locks into place. Remove plastic/rubber dust cap and fit appropriate fiber cable. Removing SFP – Remove fiber connector. Pull the SFP lever down to unlock SFP from housing. Using the lever, gently pull the SFP out. Fiber SFP FIGURE 4: FITTING/REMOVING SFP CONNECTORS Inserting SFP Removing SFP 1 2

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 10 8 CLI OVERVIEW 8.1 CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers is required to be installed on the PC before connecting the switch.

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 11 1. Connect the Console Port on OSD2892 (Mini USB) to PC with USB cable. 2. Using HyperTerminal or similar, set up the following parameters. • Baud Rate: 115200 • Data Bits: 8 • Parity: None • Stop Bits: 1 • Flow Control: None 3. Check the link by pressing . The line should jump to the next line. 4. Using the Username and password to login the switch • Default Username: admin • Default Password: (None) 8.2 CLI COMMAND FOR IP CONFIGURATION The Command Line Interface (CLI) is a useful tool for checking link status and debugging link connections. To enable the use of CLI the OSD2892 must be connected to a PC with a USB port using a Mini-USB cable. Using a terminal emulation program such as Hyperterminal, a number of command lines specific to the OSD2892 can be implemented

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 12 • show ip interface brief: Displays the current IP address and subnet mask. • configure terminal -> interface vlan 1 -> ip address : Setup the switch IP address. The following picture is an example of how to configure the device IP into 192.168.16.88 • copy running-config startup- config: Save the current configuration to start-up configuration. The configuration will be saved into Flash so that the desired configuration setup will be in effect at the next startup. PS: All configuration changes must be saved otherwise all the changes will be lost after rebooting!

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 13 GUI Overview 8.3 DEFAULT SETTING • IP Address: 192.168.0.99 • Subnet Mask: 255.255.255.0 • Gateway: 192.168.0.1 • User Name: admin • Password: (None) 8.4 LOG INTO THE SWITCH • Connect an Ethernet cable to any switch port from a PC. It may be necessary to change the PC’s network IP address to connect to the switch. (i.e.: 192.168.0.2). Make sure the IP address of the PC and the switch in the same subnet. • In a web browser, enter the URL 192.168.0.99. • Enter the username (admin) and password (none/blank) and click “Sign In”. 8.5 GUI OVERVIEW This Quick Start Guide will only show a few main or important features to get the user running the OSD2892 successfully. On the top right hand of the GUI screen there are a few icons available to quickly navigate or obtain help for each GUI menu items. Home Logout Help HOME: Clicking the Home button will exit any GUI current screen and display the panel status. LOGOUT: Clicking the Logout button will logout the current user and close the windows session HELP: Clicking the Help button will open a help window for the current open menu window and display all functions and input arguments for that page.

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 14 8.6 IP CONFIGURATION In the treemap on the left of the GUI, expand the Configuration  System  IP. Enter the IPv4 address and Mask Length in the table. Choose the management VLAN ID to access that IP in VLAN table if VLAN function is required. If multiple IP addresses are required, click Add Interface to add more IP interfaces. Click Save to save the configuration. Use new IP address to access the switch. PS: All configuration changes must be saved otherwise all the changes will be lost after rebooting!

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 15 8.7 USERS AUTHENTICATION In the tree map on the left, expand the Configuration  Security  Switch  Users Click admin to change the current admin account setting. If multiple users are required, click Add New User PS: All configuration changes must be saved otherwise all the changes will be lost after rebooting!

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 16 8.8 SAVE CONFIGURATION TO START-UP In the treemap below, expand the Maintenance  Configuration     Save startup-config Click Save Configuration to save the configuration on start-up. 8.9 PORT SPEED SETTING The port speed settings for the OSD2892 is auto mode for copper port and 10G for SFP port. On the tree map below expand Configuration  Ports.

OPTICAL SYSTEMS DESIGN

DOC ID: 10118602 OSD2892 QUICK START GUIDE PAGE 17 9 WARRANTY Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design (OSD). OSD warrants that at the time of shipment, its products are free from defects in material and workmanship and conforms to specifications. Our Warranty conditions are outlined below: 9.1 WARRANTY PERIOD For warranty period, please call your local OSD distributor. 9.2 REPAIRS Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a “Return Material Authorisation” (RMA) form and number before returning goods. Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its nominated authorised representative, for all repairs. 9.2.1 WARRANTY REPAIRS Return shipments to OSD shall be at customer's expense and freight back to the customer will be at OSD expense. 9.2.2 OUT-OF-WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the date of dispatch. 9.2.3 SITE REPAIRS By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be charged. 9.2.4 EXCLUSIONS This warranty does not apply to defects caused by unauthorized modifications, misuse, abuse or transport damage to the equipment. All modifications to OSD’s standard product will need written authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD Technicians. Warranty is void if unauthorized removal and/or tampering with serial number and/or repair labels is evident.

Optical Systems Design Pty. Ltd.

7/1 Vuko Pl. Warriewood 2102 P.O. Box 891 Mona Vale N.S.W. Australia 2103 Telephone: +61 2 9913 8540 Facsimile: +61 2 9913 8735 Email: [email protected] Web Site: www.osd.com.au OPTIC L SYSTEMS DESIGN PTY LTD A.B.N. 83 003 020 504 Printed in Australia