Optical Systems Design OSD2892 Quick Start Manual
Read Online
Read the Optical Systems Design OSD2892 Quick Start Manual online using the built-in PDF viewer.
Text of the manual
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 3
INDEX 1
1
INTRODUCTION ...................................................................................................................... 4
2
TECHNICAL SUMMARY ........................................................................................................ 4
2.1
BRIEF DESCRIPTION .................................................................................................................. 4
2.2
APPLICATIONS .......................................................................................................................... 4
2.3
FEATURES AND BENEFITS ................................................................................................. 4
2.4
TECHNICAL SPECIFICATIONS ........................................................................................... 4
3
INSTALLATION........................................................................................................................ 6
4
OSD2892 FRONT AND REAR PANELS................................................................................. 7
4.1
FRONT PANEL ....................................................................................................................... 7
4.2
REAR PANEL ............................................................................................................................ 7
5
POWER SUPPLY CONNECTIONS ........................................................................................ 7
6
LED INDICATORS ................................................................................................................... 8
7
FITTING SFP CONNECTORS ................................................................................................ 9
8
CLI OVERVIEW ..................................................................................................................... 10
8.1
CONNECT TO CLI .................................................................................................................... 10
8.2
CLI COMMAND FOR IP CONFIGURATION ................................................................................. 11
GUI OVERVIEW ................................................................................................................................. 13
8.3
DEFAULT SETTING................................................................................................................... 13
8.4
LOG INTO THE SWITCH ............................................................................................................ 13
8.5
GUI OVERVIEW ....................................................................................................................... 13
8.6
IP CONFIGURATION ................................................................................................................. 14
8.7
USERS AUTHENTICATION ........................................................................................................ 15
8.8
SAVE CONFIGURATION TO START-UP ...................................................................................... 16
8.9
PORT SPEED SETTING .............................................................................................................. 16
9
WARRANTY ............................................................................................................................ 17
9.1
WARRANTY PERIOD .......................................................................................................... 17
9.2
REPAIRS ................................................................................................................................ 17
9.2.1
WARRANTY REPAIRS .................................................................................................... 17
9.2.2
OUT-OF-WARRANTY REPAIRS .................................................................................... 17
9.2.3
SITE REPAIRS .................................................................................................................. 17
9.2.4
EXCLUSIONS ................................................................................................................... 17
FIGURE 1: FRONT PANEL .................................................................................................................... 7
FIGURE 2: REAR PANEL ...................................................................................................................... 7
FIGURE 3: POWER CONNECTION ...................................................................................................... 7
FIGURE 4: FITTING/REMOVING SFP CONNECTORS ..................................................................... 9
TABLE 1: TECHNICAL SPECIFICATIONS ......................................................................................... 5
TABLE 2: LED FUNCTION ................................................................................................................... 8
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 4
1 INTRODUCTION
Thank you for choosing the OSD2892 40-Port (36x1G + 4x10G) L2/L3 Managed Ethernet Switch. This Quick
Start Guide is designed to guide you through the installation and basic software functions.
2 TECHNICAL SUMMARY
2.1
BRIEF DESCRIPTION
The OSD2892 is an L2/L3 managed 36 port 10/100/1000BASE-T and 4 port 10G SFP Ethernet Switch. Please see
OSD2892 datasheets for options available.
2.2
APPLICATIONS
▲
Any network utilizing a mix of copper and
fiber
▲
Industrial IP communications
▲
Self-healing Gigabit Ethernet backbone
networks
▲
Four 10G SFP trunk/uplink ports
2.3
FEATURES AND BENEFITS
▲
Complies with IEEE802.3i/802.3u/802.1ab
10/100/1000Base-T, IEEE802.3z 1000Base-
LX, IEEE802.3ae 10GBaseXX standards
▲
Supports RSTP/STP/ ITU-TG.8032
Ethernet Ring Protection Switching for
Ethernet redundancy Supports Loop
Protection
▲
IP Multicast Filtering through IGMP
Snooping V2
▲
Supports port-based VLAN and Private
VLAN
▲
QoS with eight priority levels
▲
Virtual USB console, Telnet, SNMP V1,
V2c & V3 and Web Browser
▲
Full wire-speed forwarding rate
▲
Supports IEEE802.1x Security
▲
IEEE802.3ab Link Layer Discovery
Protocol
▲
Static and LACP link Aggregation
▲
Port speed control and Port mirroring
▲
1000Mbps-Full-duplex, 10/100Mbps-
Full/Half-duplex, Auto-Negotiation, Auto-
MDI/MDIX
▲
Operates over the temperature range of -20
to +60ºC
▲
Redundant DC powering and optional
redundant AC powering
▲
Optional IEEE 802.3af/at PoE (OSD2892P)
▲
System log and remote firmware upgrading
▲
Intelligent thermal protection
▲
L3 compliant switch, including functions
like: Universal Plug and Play (UPnP),
IPv4/IPv6 L3 static routing, RFC2328
OSPFv2 dynamic routing,RFC-1812 L3
checking (version, IHL, checksum), etc.
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 5
2.4
TECHNICAL SPECIFICATIONS
TABLE 1: TECHNICAL SPECIFICATIONS
SPECIFICATION
PERFORMANCE
Electrical Data Interface
IEEE802.3i/802.3u/802.3ab, 10/100/1000Base-T Ethernet
Electrical Data Connector
RJ45 on the fixed copper ports for OSD2892 and OSD2892P
OSD2892P PoE
IEEE802.3af: 47 to 55VDC @ 0.35Amp maximum
IEEE802.3at: 47 to 55VDC @ 0.70Amp maximum
Configuration Connector
Mini USB console Port
Alarms
Four: 2 for Power Supply Status, 2 user definable via the GUI
Alarm Interface
4 opto-isolated relay drivers via two 4-way 3.5mm terminal blocks
Control
System reset
Optical Port Connector
Dual LC on 2-fiber SFP modules or SC on 1-fiber SFP modules
Trunk/Uplink Ports Optical
Interface
IEEE802.3ae for 10GBASE-SR (MM: 300m), 10GBASE-LR (SM: 10km),
10GBASE_ER (SM: 40km), 10GBASE_ZR (SM: 80km), IEEE802.3z
1000Base-Lx/Sx
Operating Mode
Half or full duplex for 10/100
Full duplex for 1G, 2.5G and 10G
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Indicators
1 x power
36 x 10/100/1000Base-T: Link Activity
36 x 10/100/10001000Base-T: Speed
4 x 10G Link/Activity/Speed
36 x 10/100/1000Base-T: PoE (OSD2892P only)
SFP Options
See OSD Datasheets #1010000X and #10210G00X for full details on available
optical SFP modules
Operating Temperature
-20°C to +60°C
Relative Humidity
5 to 95% non-condensing
Power
Requirements
OSD2892DC
10 to 36VDC @ 45VA Max via one 4-way 5.08mm terminal block
OSD2892AC
90 to 264VAC @ 50VA Max via integrated IEC power inlet module
OSD2892DAC 90 to 264VAC @ 55VA Max via two integrated IEC power inlet modules
OSD2892P
47-57 VDC @ 50VA Max (without PoE) & @ 450VA Max (with PoE0 via one
4-way 5.08mm terminal block
OSD2892P PoE Power Budget
750W maximum
Dimensions of Module (mm)
440W x 300D x 44H
Weight (kg)
4.9 for OSD2892, 5.1 for OSD2892P
102289205
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 6
3 INSTALLATION
ELECTROMAGNETIC COMPATIBILITY
WARNING: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
OPTICAL OUTPUT OPERATION
WARNING: Laser Safety: Class 1 Laser Product (SFP) per IEC 60825-1:2014 standard.
Class 1
The OSD2892 is a Class 1 laser product when SFP are
fitted
PRECAUTIONS
▲ All service personnel should be provided training as to the hazards of direct viewing of laser
radiation and of the precautionary measures during servicing of equipment
▲ Areas where laser products are installed should be restricted in access to trained service
personnel only and appropriate warning signs posted in the work area.
▲ All laser apertures should be covered by protective covers when not connected to optical
fibers. Never leave outputs uncovered.
▲ Laser equipment should be positioned above or below eye level where possible. Apertures
should be positioned away from personnel.
▲ Protective eyewear should be worn in the vicinity of laser equipment.
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 7
4 OSD2892 FRONT AND REAR PANELS
4.1
FRONT PANEL
FIGURE 1: FRONT PANEL
1. PSU1 Status LED
2. PSU2 Status LED
3. Status LED
4. USB Console Port
5. View LED Mode button
6. View mode LEDs indicators
7. 36 x 10/100/1000M COPPER ports with Link/Speed/Status LED
8. 4 x 10G Trunk/Uplink SFP ports with Link/Speed/Status LED
9. Reset Button
4.2
REAR PANEL
FIGURE 2: REAR PANEL
10. PSU Alarm Output connector
11. Programmable Alarm Output Connector
12. Earth/Ground screw
13. PSU 1 Power Supply Input/Fuse/Switch
5 Power Supply Connections
There are various power options for the OSD2892. Refer to Table 1 Power Options (Figure 3 has
OSD2892AC version shown). Power is connected to the rear of the unit.
Fuse: 1A 250V Anti-Surge, 5x20mm.
FIGURE 3: POWER CONNECTION
1
2
3
10 11
12
13
4 5 6
7
8 9
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 8
6 LED Indicators
TABLE 2: LED FUNCTION
LED
Function
PSU 1
• Red – PSU 1 Not connected or faulty
• Green – PSU 1 On
PSU 2
• Red – PSU 2 Not connected or faulty
• Green – PSU 2 On
• Off – PSU 2 not available/fitted
Status
• Red – Standby/Initialization Mode
• Green – Normal status
View Mode LED
Indicators
Controlled by View LED Mode Button. Pressing the Mode button cycles the
Copper Port Status LED indication.
Speed Mode Duplex Mode Status Mode Reserved
Copper Port Status
LED
The Copper Port Status LED will indicate different information.
Speed Mode:
• Green – 1Gbps
• Yellow – 100MBps
• Off – No Connection
• Blinking – Traffic
Duplex Mode:
• Green – Full Duplex
• Yellow – Half Duplex
• Off – No Connection
Status Mode:
• Green – Connection established
• Off – No Connection
Fiber Port Status
LED
The Fiber Port Status LED will indicate different information.
Speed Mode:
• Green – 1Gbps or 10Gbps
• Yellow – 100MBps
• Off – No Connection
Duplex Mode:
• Green – Full Duplex
• Off – No Connection
Status Mode:
• Green – Connection established
• Off – No Connection
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 9
7 Fitting SFP Connectors
Care should be taken when inserting/removing the SFP connectors from the SFP port as SFP modules
are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) precautions should be taken when
installing. Ensure that the SFP is fully engaged and latched into position.
Inserting SFP – Ensure that the SFP lever is in the locked position and insert into appropriate SFP
port. Gently push the SFP until it locks into place. Remove plastic/rubber dust cap and fit appropriate
fiber cable.
Removing SFP – Remove fiber connector. Pull the SFP lever down to unlock SFP from housing.
Using the lever, gently pull the SFP out.
Fiber SFP
FIGURE 4: FITTING/REMOVING SFP CONNECTORS
Inserting
SFP
Removing
SFP
1
2
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 10
8 CLI OVERVIEW
8.1
CONNECT TO CLI
The Silicon Laboratories CP210x VCP Drivers is required to be installed on the PC before connecting
the switch.
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 11
1. Connect the Console Port on OSD2892 (Mini USB) to PC with USB cable.
2. Using HyperTerminal or similar, set up the following parameters.
•
Baud Rate: 115200
•
Data Bits: 8
•
Parity: None
•
Stop Bits: 1
•
Flow Control: None
3. Check the link by pressing . The line should jump to the next line.
4. Using the Username and password to login the switch
•
Default Username: admin
•
Default Password: (None)
8.2
CLI COMMAND FOR IP CONFIGURATION
The Command Line Interface (CLI) is a useful tool for checking link status and debugging link
connections. To enable the use of CLI the OSD2892 must be connected to a PC with a USB port using
a Mini-USB cable. Using a terminal emulation program such as Hyperterminal, a number of command
lines specific to the OSD2892 can be implemented
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 12
•
show ip interface brief: Displays the current IP address and subnet mask.
•
configure terminal -> interface vlan 1 -> ip address : Setup the
switch IP address. The following picture is an example of how to configure the device IP into
192.168.16.88
•
copy running-config startup- config: Save the current configuration to start-up configuration.
The configuration will be saved into Flash so that the desired configuration setup will be in
effect at the next startup.
PS: All configuration changes must be saved otherwise all the changes will be lost after
rebooting!
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 13
GUI Overview
8.3
DEFAULT SETTING
• IP Address: 192.168.0.99
• Subnet Mask: 255.255.255.0
• Gateway: 192.168.0.1
• User Name: admin
• Password: (None)
8.4
LOG INTO THE SWITCH
• Connect an Ethernet cable to any switch port from a PC. It may be necessary to change the
PC’s network IP address to connect to the switch. (i.e.: 192.168.0.2). Make sure the IP
address of the PC and the switch in the same subnet.
• In a web browser, enter the URL 192.168.0.99.
• Enter the username (admin) and password (none/blank) and click “Sign In”.
8.5
GUI OVERVIEW
This Quick Start Guide will only show a few main or important features to get the user running the
OSD2892 successfully. On the top right hand of the GUI screen there are a few icons available to
quickly navigate or obtain help for each GUI menu items.
Home Logout Help
HOME: Clicking the Home button will exit any GUI current screen and display the panel status.
LOGOUT: Clicking the Logout button will logout the current user and close the windows session
HELP: Clicking the Help button will open a help window for the current open menu window and
display all functions and input arguments for that page.
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 14
8.6
IP CONFIGURATION
In the treemap on the left of the GUI, expand the Configuration System IP.
Enter the IPv4 address and Mask Length in the table.
Choose the management VLAN ID to access that IP in VLAN table if VLAN function is required.
If multiple IP addresses are required, click Add Interface to add more IP interfaces.
Click Save to save the configuration.
Use new IP address to access the switch.
PS: All configuration changes must be saved otherwise all the changes will be lost after
rebooting!
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 15
8.7
USERS AUTHENTICATION
In the tree map on the left, expand the Configuration Security Switch Users
Click admin to change the current admin account setting.
If multiple users are required, click Add New User
PS: All configuration changes must be saved otherwise all the changes will be lost after
rebooting!
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 16
8.8
SAVE CONFIGURATION TO START-UP
In the treemap below, expand the Maintenance Configuration
Save startup-config
Click Save Configuration to save the configuration on start-up.
8.9
PORT SPEED SETTING
The port speed settings for the OSD2892 is auto mode for copper port and 10G for SFP port. On the
tree map below expand Configuration Ports.
OPTICAL SYSTEMS DESIGN
DOC ID: 10118602
OSD2892 QUICK START GUIDE
PAGE 17
9 WARRANTY
Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design
(OSD). OSD warrants that at the time of shipment, its products are free from defects in material and
workmanship and conforms to specifications. Our Warranty conditions are outlined below:
9.1
WARRANTY PERIOD
For warranty period, please call your local OSD distributor.
9.2
REPAIRS
Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a
“Return Material Authorisation” (RMA) form and number before returning goods.
Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its
nominated authorised representative, for all repairs.
9.2.1
WARRANTY REPAIRS
Return shipments to OSD shall be at customer's expense and freight back to the customer will be at
OSD expense.
9.2.2
OUT-OF-WARRANTY REPAIRS
OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both
journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the
date of dispatch.
9.2.3
SITE REPAIRS
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be
charged.
9.2.4
EXCLUSIONS
This warranty does not apply to defects caused by unauthorized modifications, misuse, abuse or
transport damage to the equipment. All modifications to OSD’s standard product will need written
authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD
Technicians. Warranty is void if unauthorized removal and/or tampering with serial number and/or
repair labels is evident.
Optical Systems Design Pty. Ltd.
7/1 Vuko Pl. Warriewood 2102
P.O. Box 891 Mona Vale
N.S.W. Australia 2103
Telephone: +61 2 9913 8540
Facsimile: +61 2 9913 8735
Email: [email protected]
Web Site: www.osd.com.au
OPTIC
L
SYSTEMS
DESIGN
PTY LTD
A.B.N. 83 003 020 504
Printed in Australia