JOYTECH DMT-4751 Owner's Manual

Specifications

Brand: JOYTECH
Category: Thermometer
Model: DMT-4751 (Owner's Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the JOYTECH DMT-4751 Owner's Manual online using the built-in PDF viewer.

Text of the manual

* The performance of the device may be degraded should one or more of the following occur:

- Operation outside the manufacturer s s tated te mperature a nd h umidity r ange. ’ - Storage outside the manufacturer s s tated te mperature a nd h umidity r ange. ’ - Mechanical shock (for example, drop test) or degraded sensor.. - Patient temperature is below ambient temperature. * Portable and mobile RF communications can affect the device. The device needs special pre-cautions regarding EMC according to the EMC information provided in the accompany documents. 124mm This digital thermometer provides a quick and highly accurate reading of an individual's body temperature. To better understand its functions and to provide years of dependable results, please read all instructions first. This appliance conforms to the following standards: EN 12470-3 Clinical thermometers —Part 3: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device, ISO 80601-2-56 Medical electrical equipment —Part 2-56:Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, EN 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment and complies with the requirements of EN 60601-1-2(EMC), IEC/EN60601-1(Safety) standards. And the manufacturer is ISO 13485 certified. The digital thermometer is intended to measure the human body’s temperature in regular mode orally, rectally or under the arm, and the device is reusable for clinical or home use on people of all ages. PLEASE READ CAREFULLY BEFORE USING CONTENTS OWNER S M ANUAL ’ 1 Thermometer, 1 Owner s Manual, 1 Storage Case ’ Model:DMT-4751 DIGITAL THERMOMETER PRECAUTION Figure 1 Warning : Read instructions thoroughly before using digital thermometer. Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children to use this device without parental supervision. Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only. Do not place thermometer battery near extreme heat as it may explode. Note: Use of the probe cover may result in a 0.01℃(0.02℉) discrepancy from actual temperature. Remove battery from the device when not in operation for a long time. The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions. Do not attempt measurements when the thermometer is wet as inaccurate readings may result. Do not bite the thermometer. Doing so may lead to breakage and/or injury. Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings. After each use, disinfect the thermometer especially in case the device is used by more than one person. Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present. Failure to do so may lead to injury. Do not use thermometer orally after being used rectally. For children who are two years old or younger, please do not use the devices orally. If the unit has been stored at temperatures over 5℃~40℃(41℉~104℉), leave it in 5℃~40℃ (41℉~104℉) ambient temperature for about 15 minutes before using it. 357.00 Figure 2 ℃/℉ SWITCHABLE When finishing measurement or entering into the memory mode, user can change the unit though APP after connecting bluetooth. SPECIFICATIONS ±0.05℃(±0.1℉) during 35.00℃~38.00℃(95.00℉~100.40℉) at 18.00℃~28.00℃(64.40℉~82.40℉) ±0.1℃(±0.2℉) for other measuring and ambient operating range temperature range One 3.0V DC button battery type CR2032 Measure Range: Ambient operating range: Storage and transportation condition: Organic Light Emitting Display , 4 ½ digits. For storing the last 30 measurements. 3 measurements per day about 70 times 104.9mm×33mm×12.8mm(L x W x H) Approx. 24 grams including battery Temperature: ( ) 5℃~40℃ 41℉~104℉ Relative humidity: 15%~95%RH Atmospheric Pressure : 700hPa ~ 1060hPa Temperature: ( ) -20℃~55℃ -4℉~131℉ Relative humidity: 15%~95%RH Atmospheric Pressure : 700hPa ~ 1060hPa Classification: Type: Digital Thermometer (Not Predictive) Type BF Direct Mode Ingress Protection Rating: IP 64 Accuracy: Operating mode: Display: Memory: Battery: Battery life: Dimension: Weight: Expected service life: Three years 32.00℃-43.99℃(89.60℉-111.18℉)(℃ /℉ chosen by user) PRODUCT FUNCTIONS & FEATURES This product has two parts functions : the first function can be used to measure the temperature of the vagina, this function should be used by women to measure basal body temperature. the second function can be used as a normal thermometer ,used to measure and record body temperature data, this function suitable for most people to use . PRODUCT ILLUSTRATION On/Off Button OLED Probe SYMBOL EXPLANATION Direct Current Type BF Applied Part Batch Code Manufacturer Consult Accompanying Documents Storage and Transportation Temperature Limit: -20℃~55℃ (-4℉~131℉) -20℃ 55℃ EC REP European Authorized Representative prevent the measurement from being influenced by inhaled/exhaled air. Normal temperature between 35.70 and 37.30 (96.26 and 99.14 ) b)Vaginal:Place probe tip approximately 1cm (less than 1/2 ") into vaginal. Normal temperature between 36.20 and 37.70 (97.16 and 99.86 ). 4、The thermometer will finish measurement with one short beep after 3 minutes. To make sure the accuracy, do not move the thermometer during the measurement. After finishing the measurements, user can connect bluetooth through APP and upload the data. Remark:When using the thermometer at the first time, pls enter the passkey to connect the bluetooth and APP. 5、To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no action is taken, the unit will automatically shut off after around 30s. *Note: ①. If the measured temperature is less than 32.00 or 89.60 , the OLED will display “Lo” below the graduation lines without scale bar, if the measured temperature is higher than 43.99 or 111.18 , the OLED will display all scale bars with “Hi” above. ②.When connecting the APP via bluetooth, please enter the correct key. .When the OLED display “--.-- ” or “--.-- ”,it means that the thermomenter has no memory. .When bluetooth connects to APP, the LED will light up, and when bluetooth disconnects from APP, the LED will go out. ℃ ℃ ℉ ℉ ℃ ℃ ℉ ℉ ℃ ℉ ℃ ℉ ③ ℃ ℉ ④ TROUBLESHOOTING Problem Solution Error message The system is not functioning properly. Unload the battery, wait for 1 minute and repower it. If the message reappears, contact the retailer for service. Temperature taken is lower than 32.00°C(89.60°F) Turn off, wait 10 minute and take a new temperature via close contact and sufficient rest. Temperature taken is higher than 43.99°C(111.18°F) Dead battery: Battery icon is flashing, can’t be measurable. Suggest to replace the battery. Turn off, wait 10 minute and take a new temperature via close contact and sufficient rest. LIMITED WARRANTY The thermometer is guaranteed for one year from the date of purchase. If the thermometer does not function properly due to defective components or poor workmanship, we will repair or replace it free of charge. All components are covered by this warranty excluding the battery. The warranty does not cover damages to your thermometer due to improper handling. To obtain warranty service, an original or copy of the sales receipt from the original retailer is required. Disposal of this product and used batteries should be carried out in accordance with the national regulations forthe disposal of electronic products. Document No. JDMT-7804-002 Article No.: 001 Version: Z Date of Issue: 2018.11 BATTERY REPLACEMENT 1. Replace battery when “ ” appears in the lower right corner of OLED display. 2. Put a thin board such as a coin on fillister of cover. Turn the battery anti-clockwise until the cover is off (See Figure 3). 3. Use a non-meteal instrument such as a pen to remove old battery from the battery holder (See Figure 4). Discard battery according to local law. 4. Place a new into the chamber with positive side facing up.(See Figure 5). 5. With a thin pin to turn the cover clockwise until the “ ” facing towards “ ”(See Figure 6). 3.0V DC CR2032 Figure 4 Figure 3 Figure 5 Figure 6 JOYTECH HEALTHCARE CO.LTD. No.365, Wuzhou Road, Yuhang Economic Development Zone, Hangzhou city, 311100 Zhejiang,China Tel:+86-571-81957767 CLEANING AND DISINFECTION Wipe the thermometer with a soft clean cloth.For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.For disinfection, 75% Ethanol or Isopropyl alcohol can be used.Observe the following to prevent damage to the thermometer. -Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer. -Do not attempt to disinfect the sensing section (tip) of the thermometer by immersing in alcohol or in hot water (water over 50℃(122℉)). -Do not use ultrasonic washing to clean the thermometer. CALIBRATION The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to the use instruction, periodic readjustment is not required. However, we recommend checking calibration every two years or whenever clinical accuracy of the thermometer is in question. Turn on the thermometer and insert into the water bath and then check the laboratory accuracy of thermometer. Please send the complete device to the dealers or manufacturer. The above recommendations do not supersede the legal requirements. The user must always comply with legal requirements for the control of the measurement, functionality, and accuracy of the device which are required by the scope of relevant laws, directives or ordinances where the device is used. FCC INFORMATION Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: ( *Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the distance between the equipment and the receiver. - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. 1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made in China HOW TO USE THIS PRODUCT 1、Please download and install APP before using this product. 2、Turn on the phone bluetooth through APP and press the on/off button next to OLED display to turn on the device.The display will briefly shows full segment at current unit mode. Show the last stored temperature. When the OLED display “Lo ”or "Lo " , it means that the thermometer is waiting for measurement. 3、Placing thermometer in desired position a) Oral Use: Place thermometer under tongue as indicated by“√”position shown in Figure 2. Close your mouth and breathe evenly through the nose to ℃ ℉

Electromagnetic Compatibility Information

The device satisfies the EMC requirements of the international standard IEC 60601-1-2. The requirements are satisfied under the conditions described in the table below. The device is an electrical medical product and is subject to special precautionary measures with regard to EMC which must be published in the instructions for use. Portable and mobile HF communications equipment can affect the device. Use of the unit in conjunction with non-approved accessories can affect the device negatively and alter the electromagnetic compatibility. The device should not be used directly adjacent to or between other electrical equipment. Table 1 Table 2 Guidance and declaration of manufacturer-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Electromagnetic environmentguidance Compliance level IEC 60601 test level IMMUNITY test N/A 10 V/m 3 Vrms 150 kHz to 80 Mhz 10 V/m 80 MHz to 2.7 Ghz Conducted RF IEC 61000-4-6 Radiated RF IEC 61000- 4-3 Table 3 Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended seperation distance 80 MHz to 800 MHz 800 MHz to 2.7 Ghz where P is the maximum output power rating of the transmitter in watts (W) according to the transm- itter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. Interference may occur in the vicinity of equipment marked with the following symbol: Recommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated therefore disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Table 4 800 MHz to GHz 2.7 0.01 0.1 1 10 100 0.12 0.38 1.2 3.8 0.23 0.73 2.3 7.3 23 Guidance and declaration of manufacturer-electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Electromagnetic environment-guidance Compliance Emissions test The device uses RF energy only for its internal function. Therefore, its emissions are very low and are not likely to cause any interference in nearby electronic equipment. Group 1 RF emissions CISPR 11 The device is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Class B RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 N/A Voltage fluctuations/ flicker emissions IEC 61000-3-3 N/A 12 Separation distance according to frequency of transmitter m 80 MHz to 800 MHz For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE1 At 80 MHz and 800 MHz, the separation distance for the higer frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Guidance and declaration of manufacturer-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Electromagnetic environm entguidance Compliance level 124mm 254mm IEC 60601 test level IMMUNITY test Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. ± 8 kV contact ±2 kV,±4 kV, ±8 kV, ±15 kV air Electrostatic discharge (ESD) IEC 61000-4-2 Electrostatic transient/burst IEC 61000-4-4 ± 2 kV for power supply lines ± 1 kV for input/output lines N/A Surge IEC 61000-4-5 ± 1 kV differential mode ± 2 kV common mode N/A Voltage dips, short interrupti- ons and voltage variations on p- ower supply in- put lines IEC 61000-4-11 < 5% UT (>95% dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycle 70% UT (30% dip in UT) for 25 cycle <5% UT (>95% dip in UT) for 5 secretary Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 Power frequency magnetic fields should be at levels charactertic of a typical location in a typical comme- rcial or hospital environment. N/A ± 8 kV contact ±2 kV,±4 kV, ±8 kV, ±15 kV air 30 A/m; 50Hz or 60Hz 30 A/m; 50Hz or 60Hz 380MHz, 27V /m 450MHz, 28V /m 710MHz,745 MHZ,780MHz 9V/m 810MHz,870 MHZ,930MHz 28V/m 1720MHz,1845 MHZ,1970MHz 28V/m 2450MHz, 28V /m 5240MHz,5500 MHZ,5785MHz 9V/m 380MHz, 27V /m 450MHz, 28V /m 710MHz,745 MHZ,780MHz 9V/m 810MHz,870 MHZ,930MHz 28V/m 1720MHz,1845 MHZ,1970MHz 28V/m 2450MHz, 28V /m 5240MHz,5500 MHZ,5785MHz 9V/m RF Wireless Communication Equipment IEC 61000- 4-3

Other Thermometer Manuals