Kanomax 6332 Operation Manual
Read Online
Read the Kanomax 6332 Operation Manual online using the built-in PDF viewer.
Text of the manual
AIR FLOW TRANSDUCER
MODEL 6332/6332D
Please read this manual carefully and understand the warnings
described in this manual before operating the product.
Keep this manual handy for ready reference
02001
0809
Kanomax 6332 Airflow Transducer Air Velocity Sensor Anemometer
Kanomax 6332D Airflow Transducer Air Velocity Sensor Anemometer
netzerotools.com
netzerotools.com
netzerotools.com
Thank you for purchasing a product of Kanomax, Inc.
Please read this operation manual carefully and operate the instrument
appropriately by following the instructions given in this manual.
netzerotools.com
netzerotools.com
Main Unit (Without Display)
6332
-
Airflow Transducer
Main Unit (With Display)
6332D
-
■ Probe & Cable (Sold Separately)
Item
Model
Remarks
0962-00
0963-00
Uni-directional
0964-01
0964-02
Omni-directional (Needle)
0965-00
0965-01
Omni-directional (Spherical)
0965-03
0965-04
Mini-temperature-compensation-sensor
integrated type
Omni-directional (Spherical)
0965-07
Air Velocity Probe
0965-08
Mini-temperature-compensation-sensor
independent type
Omni-directional (Spherical)
1504-04
Length: 10m
1504-05
Length: 20m
Probe Cable
1504-06
Length: 30m
■ Optional Accessory
Item
Model
Remarks
Display Unit
6332-01
-
AC Adapter
6332-02
-
netzerotools.com
netzerotools.com
Important Safety Information
In this operation manual, warning types and classifications are defined as follows.
[Classifications]
Danger: To Prevent Serious Injury or Death
Warnings in this classification indicate danger that may result in serious injury or
death if not observed.
Caution: To Prevent Damage to the Product
Warnings in this classification indicate risks of damage to the product that may void
the product warranty if not observed.
[Description of Symbols]
This symbol indicates a condition (including danger) that requires caution.
The subject of each caution is illustrated inside the triangle (e.g., high temperature caution
symbol shown on the left).
This symbol indicates prohibition. Do not take a prohibited action shown inside or near this
symbol (e.g., disassembly prohibition symbol shown on the left).
This symbol indicates a mandatory action. A specific action is given near the symbol.
netzerotools.com
netzerotools.com
○ Never bring the probe close to a flammable gas
atmosphere.
--- The heated sensor may cause fire or explosion.
○ Never disassemble, modify or repair the instrument.
--- Failure to observe the above may cause short circuit and
malfunction.
○ Use the specified voltage for power supply.
--- Unspecified voltage may cause electrical shock and fire.
○ Remove dust and any impurities from the terminal block.
--- The dust/impurities may cause fire.
○ Do not use the instrument in a water vapor atmosphere.
--- Failure to observe the above may cause electrical shock,
fire, or damage to the sensor.
○ Never touch the sensor.
--- The sensor is heated during operation. Touching the heated sensor
may cause burns, and also may damage the sensor itself.
Particular attention must be paid to spherical type sensors
(Model: 0965-00/ 0965-01/ 0965-03/ 0965-04/ 0965-07/ 0965-08)
as they are very sensitive. Please Handle with care.
Water
drops
Warning:
High Temperature /
Injury
Do not use
unspecified voltage
Danger
Do not use near
flammable gas
Do not modify /
disassemble
Prohibition
Handle Properly
netzerotools.com
netzerotools.com
○ Do not use or leave the instrument in a high
temperature/humidity environment, or in a dusty
environment. The instrument must also not be left
under direct sunlight for a prolonged period.
--- The instrument may not function properly outside
the specified temperature range of 5 to 40 degrees C.
○ Do not wipe the instrument with a volatile solvent.
--- The body may deform or deteriorate. Use soft dry cloth to remove stains.
If stains persist, soak the cloth in a neutral detergent and wipe the instrument
with the soft cloth.
Never use volatile solvents such as thinner and benzine.
○ Do not apply strong shock to the instrument
and probe.
--- Applying strong shock may cause damage and
malfunction to the instrument and probe.
Caution
Prohibited
Installation
Prohibition
Prohibition
netzerotools.com
netzerotools.com
Table of Contents
� Names and Dimensions of Components......................................................1
� System Configuration Example....................................................................5
� Connecting the Probe Cable to the Main Unit .............................................6
� Connecting the Probe Cable to the Probe.....................................................6
� Installing the Data ROM...............................................................................7
� Switching Output (Setting Current/Voltage and Output Range).................8
� Connecting Output and Power Supply.......................................................10
� Measurement Method.................................................................................11
� Optional Accessory.....................................................................................12
Display Unit ....................................................................................................................12
AC Adapter ....................................................................................................................13
� Cleaning the Probe ......................................................................................14
� Specification of Main Unit..........................................................................15
� Specification of Probes (Sold Separately)..................................................16
� Troubleshooting...........................................................................................18
� Product Warranty and After Service...........................................................19
� Contact Information ....................................................................................20
netzerotools.com
netzerotools.com
Names and Dimensions of Components
(1) Model 6332 View inside the Case
Probe Cable Connector
Output Changeover
Switch
Range Changeover
Switch
ROM Socket
Output and Power Terminal Blocks
netzerotools.com
netzerotools.com
(2) Model 6332D View inside the Case
Probe Cable Connector
Output Changeover
Switch
Range Changeover
Switch
ROM Socket
Output and Power Terminal Blocks
Display Substrate
netzerotools.com
netzerotools.com
(3) Model 6332 View with the Case
72
60
128
116
78
17
103
16
1
30
4-φ4.5 Hole
netzerotools.com
netzerotools.com
(4) Model 6332D View with the Case
72
60
128
116
78
17
103
16
1
30
4-φ4.5 Hole
12
26
40
netzerotools.com
netzerotools.com
System Configuration Example
Probe (Sold Separately)
Probe Cable (Sold Separately)
Display (Only for 6332D)
AC Adapter (Optional)
Output Cable (Not Provided)
netzerotools.com
netzerotools.com
Connecting the Probe Cable to the Main Unit
Installing the Data ROM
Switching Output (Setting Current/Voltage and Output Range)
Connecting Output and Power Supply
1. Using the Uni-directional Probe (Model 0962-00, 0963-00)
These probes have directivity characteristics which require the direction mark to be faced against the
airflow for measurement. When you are not sure of the airflow direction, slowly rotate the probe in the
horizontal direction, and select the point where the air velocity reading is maximum.
2. Using the Omni-directional Probe (Model 0964-01/02, 0965-00, 0965-01/03/04/07/08)
These probes have uniform sensitivity 360 degrees horizontally. They only need to be set vertical to the
airflow direction for measurement, regardless of the orientation in the horizontal direction.
The probe employs a set of air velocity sensor and temperature compensation sensor to compensate the air
velocity change corresponding to the air temperature change.
In order to obtain this compensation effect, it is required that both the air velocity sensor and the
temperature compensation sensor are exposed to the airflow to be measured under the same temperature
condition. (Refer to the dimensional drawings of probes shown on page 16, 17 to locate the air velocity
sensor and the temperature compensation sensor on each probe.)
Airflow
Direction Mark
Airflow
1. Uni-directional Probe
2. Omni-directional Probe
Probe Direction
netzerotools.com
netzerotools.com
1. Display Unit (Model 6332-01)
Number of digits and range of air velocity value to be shown on the display corresponds to the setting of
the air velocity output range as shown below.
No.
Output Range [m/s]
Display Range [m/s]
0
0 ~ 2.00
0.00 ~ 2.00
1
0 ~ 5.00
0.00 ~ 5.00
2
0 ~ 10.00
0.00 ~ 10.00
3
0 ~ 25.0
0.0 ~ 25.0
4 ~ 9
0 ~ 50.0
0.0 ~ 50.0
To add the display substrate to a unit without a display (Model 6332):
-
Position the substrate in the correct orientation, and fix the substrate with the supplied two screws
carefully not to bend the connection pins.
-
Replace the case without the display window with the case equipped with the display window
(supplied with the display unit).
Supplied Screws
Display Substrate
* The side with the number
must come to the right.
* Pay close attention not to bend
the pins when inserting.
netzerotools.com
netzerotools.com
2. AC Adapter (Model 6332-02)
Cleaning the Probe
If any impurities such as dust, soot and oil are attached to the sensor, the amount of heat that the airflow
draws from the sensor surface (heat dissipation rate) will change, thus the air velocity reading will be
affected.
The probe must be cleaned when the sensor is contaminated from use in an unclean environment.
Clean the sensor portion of the probe in an ultrasonic cleaner for approx. 10-20 sec. Do not clean the
sensor longer than required as excess cleaning will lead to sensor damage.
Use tap water (or purified water) for cleaning. The sensor portion can also be cleaned in a vessel
filled with neutral detergent diluted with water, and by stirring it in the vessel.
!) Make sure to TURN OFF the power before cleaning.
!) Dry the probe completely after cleaning. Do not use the probe before it is completely dried.
Cleaning Method
Clean in an ultrasonic cleaner for approx.
10-20 sec.
Do not point the sensor upwards until it is
completely dried. The water drops may get
inside the probe and cause malfunction.
! Caution !
Dry with cold air.
netzerotools.com
netzerotools.com
Specification of Main Unit
Product Name
Airflow Transducer (with / without Display)
Model
6332 / 6332D
Measuring Object
Clean Airflow
Measuring Range
Maximum range 0.1 ~ 50 m/s (Depending on the measurement range of the probe*)
Measuring Accuracy
± (3% of reading + 0.1) m/s
0.1-4.99m/s
5.00-9.99m/s
10.0-24.9m/s
25.0-50.0m/s
5~40℃
±0.25m/s
±0.50m/s
±1.25m/s
±2.50m/s
Temperature
Compensation Range
40~80℃
±0.35m/s
±0.70m/s
±1.75m/s
±3.50m/s
Output
To select either current or voltage output (setting made with the DIP switch).
Current output: DC 4~20mA (Max. load resistance: 250Ω)
Voltage output: DC 0~5V
Setting of
Output Range
To be selected from the followings (setting made with the rotary switch).
0~2, 0~5, 0~10, 0~25, or 0~50 m/s
Display (Optional)
Number of digits and range of value to be displayed change in accordance with the
setting of the output range.
When setting of output range: 0~2, 0~5, 0~10 m/s → Display Resolution: 0.01m/s
When setting of output range: 0~25, 0~50 m/s → Display Resolution: 0.1m/s
Power Supply
DC 12~24V
Power Consumption
(Reference Value)
Approx. 2.0W (Under the following conditions - power supply: 12V, air velocity:
approx. 10m/s, using a unit with a display with probe model 0965-03.)
Power consumption rate is subject to change according to conditions such as air
velocity, probe type and use of display.
Connection Wire Size
0.5 ~ 1.5 mm2
Operating Temperature
Range
5 ~ 40 degrees C
Storage
Temperature Range
-10 ~ 50 degrees C
Dimensions
Approx. 128(W)×78(D)×30(H)
Weight
Approx. 320g
Standard Accessory
Operation Manual : 1
Main Unit Case: 1
Optional Accessory
Probe Cable (10m, 20m, 30m)
Display Unit (Supplied with a case with a display window and 2 installation screws.)
Dedicated AC Adapter (DC12V)
* Refer to “Specification of Probes” on page 16.
netzerotools.com
netzerotools.com
Specification of Probes (Sold Separately)
MODEL
Measuring Range
Sensor Type
0962-00
0963-00
Uni-directional
0964-01
0964-02
0.1~50.0m/s
Omni-directional (Needle)
0965-00
0965-01
0.1~25.0m/s
Omni-directional (Spherical)
0965-03
0965-04
Mini-temperature-compensation-sensor
integrated type
Omni-directional (Spherical)
0965-07
0965-08
0.1~25.0m/s
Mini-temperature-compensation-sensor
independent type
Omni-directional (Spherical)
Air Velocity Sensor
Temp. Compensation Sensor
Air Velocity Sensor
Temp. Compensation Sensor
seSensor
Lead wire: 300mm
Air Velocity Sensor
Temp. Compensation Sensor
netzerotools.com
netzerotools.com
Air Velocity Sensor
Air Velocity Sensor
Temp. Compensation Sensor
seSensor
Temp. Compensation Sensor
I-type
L-type
I-type
L-type
Shielded Cable
Shielded
Cable
Air Velocity Sensor
Temp. Compensation Sensor
00: protruding tip
01: no protrusion
netzerotools.com
netzerotools.com
Please check the following list before requesting a repair:
Symptom
Possible Cause
Solution (& Reference Page)
No Output
The main unit is not turned on.
Supply power to the main unit. (Page 10)
Wrong wiring of the output terminal.
Provide proper wiring. (Page 10)
Probe is not connected properly.
Turn off the power. Reconnect the probe to
the main unit and turn the power back on.
(Page 6)
Contact of the terminal block is dirty.
Clean the contact of the terminal block.
Abnormal Output
Probe is not connected properly.
Turn off the power. Reconnect the probe to
the main unit and turn the power back on.
(Page 6)
The ROM number is not consistent with
the probe number.
Insert the correct ROM that corresponds to
the probe number. (Page 7)
Probe is dirty.
Clean the probe. (Page 14)
Measured velocity is out of the specified
range.
Confirm the probe specifications. (Page 16)
FG terminal is not connected to ground.
Confirm that FG terminal is properly
connected to ground (earthed).
(Page 10)
Influence of noise.
Confirm the output in an environment with
less noise (e.g. outside the office or plant). If
the output there is found to be normal, noise
prevention measures need to be taken at the
measurement location.
For details, please contact our service
center.
netzerotools.com
netzerotools.com
Product Warranty and After Service
� A warranty card is not included in this product.
� This product is warranted against defects in materials and workmanship for a period of one year from
the date of original purchase.
�
When you have a problem with your unit, please check out the “Troubleshooting” section (page 18)
first.
�
If that does not help, please contact your local distributor, or call our service center (See last page for
contact information).
�
During the warranty period, we will repair at no charge a product that probes to be defective due to
material or workmanship under normal use. The limited warranty covers all defects encountered in
normal use of the product, and does not apply in cases such as; loss or damage to the product due to
abuse, mishandling, alternation, or natural disaster. All return shipping charges are the responsibility
of the customer.
�
Repair after warranty expiration:
Upon request, we will repair the instrument at the customer’s expense, if the instrument’s performance
is found to be recoverable by providing the repair.
�
Replacement parts are available for a minimum period of five (5) years after termination of
production. This storage period of replacement parts is considered as the period during which we can
provide repair service. For further information, please contact our service center.
�
When making an inquiry, please provide the following information.
Please inform us:
-
Product Name: Air Transducer
-
Model Number: 6332 or 6332D
-
Serial Number: xxxxxx
-
Probe Model:
Your Probe Model
-
Description of Symptom in detail.
-
Date of Purchase: Month / Year
After Service