Da-Lite Cosmopolitan Electrol Instruction Book
Text of the manual
DA-LITE SCREEN COMPANY, INC.
3100 North Detroit Street
Post Office Box 137
Warsaw, Indiana 46581-0137
Phone: 574-267-8101
800-622-3737
Fax: 574-267-7804
Toll Free Fax: 877-325-4832
www.da-lite.com
e-mail: [email protected]
POWER
PRESENTATION PRODUCTS
The
In
Instruction Book for
COSMOPOLITAN® ELECTROL®
For Sizes Up To 9'x12'
There are three methods of mounting to include:
Flush against wall; Suspended from ceiling (use extension brackets); and Recessed above ceiling.
NOTE: Under no circumstances should unit be completely sealed in recessed installation. Allow access for service. Picture surface
is centered in case. Case extends 4" beyond surface on either end. Do not attach anything to screen slat rod or bottom fabric pocket.
1.
Make sure screen is level. Use a carpenter’s level and plumb level.
CAUTION! Do not cut wrapping paper or tape with knife or any sharp tool. Remove by hand.
2.
Remove tape and rubber bands from slat pocket.
3.
Install electrical hook up that applies to your unit. Make sure to review your Electrical Installation Checklists and
wiring diagrams (included) for either 120 volt switch, 220/240 volt switch, or low voltage control.
▲!
1. Carefully unpack screen and remove outer wrapping from case.
2. Do not remove black tape or rubber bands from slat pocket.
3. Always handle screen in upright position.
FIGURE 1
CEILING HANGING
PICTURE SURFACE
PICTURE SURFACE
PICTURE
SURFACE
WALL MOUNTED
CONCEALED (ALLOW ROOM FOR ACCESS)
USE NO. 6 BRACKETS
TO HANG BEHIND
BEAM OR VALANCE
PICTURE
SURFACE
IMPORTANT SAFETY INSTRUCTIONS
When using your video equipment, basic safety precautions should always be followed, including the
following:
1. Read and understand all instructions before using.
2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces.
3. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance
should be used. Cords rated for less amperage than the appliance may overheat.
4. To reduce the risk of electric shock, do not disassemble this appliance. Contact an authorized
service dealer when repair work is required. Incorrect reassembly can cause electric shock when
the appliance is used subsequently.
5. The use of an accessory attachment not recommended by the manufacturer may cause a risk of
fire, electric shock, or injury to persons.
SAVE THESE INSTRUCTIONS
COSMOPOLITAN® ELECTROL® INSTALLATION
A
FABRIC HEIGHT x WIDTH AS ORDERED,
UP TO 12 FEET x 12 FEET.
3/8" DIAMETER FOR
CEILING INSTALLATION
ENCLOSURE COVER
7/8" DIAMETER OPENING
FOR ELECTRICAL FITTINGS
PICTURE SURFACE
3/4" DIAMETER HOLE FOR
WALL INSTALLATION
Overall length A=fabric width + 8".
Length B is the distance between wall mounting holes
at back of end caps and is the fabric width + 6-1/2".
B
4"
4"
4-5/8"
1-7/8"
13/32"
5-7/8"
1"
15/16"
FIGURE 2
MOTOR END
Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly
adjusted at DA-LITE. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the
following manner:
NOTE: Use a screwdriver or allen wrench to make adjustments.
SETTING THE DOWN LIMIT POSITION
TO REDUCE SCREEN DROP:
Turn the white limit switch screw clockwise to decrease the amount of screen drop. Run the screen down to test
the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit switch again.
Repeat until the desired position is set.
TO INCREASE SCREEN DROP:
Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down
to test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit
switch again. Repeat until the desired position is set. Do not adjust for more drop than what was ordered. At least
1-1/2 wraps of fabric must remain on the roller.
SETTING THE UP LIMIT POSITION
CAUTION: Do not allow the slat bar to wrap over the top of the roller when the screen is rolling into the case. The screen could
be damaged.
SCREEN TRAVELS INTO CASE TOO FAR:
Turn the black limit switch screw clockwise to decrease the amount of travel. Run the screen up to test the stop
position. If the screen does not stop properly, lower the screen about one foot and turn the limit switch again.
Repeat until the desired position is set.
SCREEN DOES NOT TRAVEL FAR ENOUGH INTO CASE:
Turn the black limit switch screw counterclockwise to increase the amount of up travel. Run the screen up to test
the stop position. If more travel is desired, lower the screen about one foot and adjust the limit switch again.
Repeat until the desired position is set.
▲!
3
SCREEN ADJUSTMENT FOR 120V SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL
FIGURE 3
COSMOPOLITAN® ELECTROL® INSTALLATION
WIRING ENCLOSURE COVER
UP BLACK
LIMIT SWITCH
ADJUSTMENT
AND DOWN
WHITE LIMIT
SWITCH
ADJUSTMENT
TO JUNCTION BOX, MOUNTED IN
SCREEN CASE, IN WHICH INTERNAL
WIRING TERMINATES IN WHITE,
BLACK AND RED LEADS
IN MULTIPLE CONTROL INSTALLATIONS
THIS SWITCH IS REPLACED BY THE LOW
VOLTAGE CONTROL, OPERATED FROM
PUSH BUTTON STATIONS.
OPERATING SWITCH AND
PLATE FURNISHED WITH
SCREEN. (SPDT WITH
CENTER OFF)
SIDE VIEW
OF SWITCH
AND BOX
THIS SWITCH CANNOT BE USED WITH LVC.
NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.
DOWN
BLACK
BLACK
UP
WHITE
RED
DOWN
AC HOT
OFF
COMMON
WHITE
BLACK WITH
YELLOW
UP
RED
ROCKER
SWITCH
AC COMMON
120 V. 60 HZ. 2.5 MAX. AMP
120V WIRING DIAGRAM
220 / 240V
WIRING DIAGRAM
IN MULTIPLE CONTROL INSTALLATIONS THIS
SWITCH IS REPLACED BY THE LOW VOLTAGE
CONTROL, OPERATED FROM PUSH BUTTON
STATIONS.
OPERATING SWITCH AND
PLATE FURNISHED WITH
SCREEN.
NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.
BLACK (UP)
UP
DOWN
BROWN AC HOT
OFF
ROCKER
SWITCH
BLUE AC COMMON
220/240 V. AC 50 HZ.
2 AMP MAX.
BROWN (DOWN)
BLUE (COMMON)
BROWN /YELLOW
JUNCTION
BOX
BLUE JUMPER WIRE
REAR VIEW OF DPDT,
WITH CENTER OFF.
NOTE:
MUST BE WIRED TO CONFORM TO LOCAL WIRING
CODE. THIS SWITCH CANNOT BE USED WITH L.V.C.
FIGURE 3
WIRING ENCLOSURE COVER
UP RED
LIMIT SWITCH
ADJUSTMENT
AND DOWN
WHITE LIMIT
SWITCH
ADJUSTMENT
TO JUNCTION BOX, MOUNTED IN
SCREEN CASE, IN WHICH INTERNAL
WIRING TERMINATES IN BLUE,
BROWN AND BLACK LEADS
COSMOPOLITAN® ELECTROL® INSTALLATION
Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly
adjusted at DA-LITE. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the
following manner:
NOTE: Use a screwdriver or allen wrench to make adjustments.
SETTING THE DOWN LIMIT POSITION
TO REDUCE SCREEN DROP:
Turn the white limit switch screw clockwise to decrease the amount of screen drop. Run the screen down to test
the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit switch again.
Repeat until the desired position is set.
TO INCREASE SCREEN DROP:
Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down
to test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit
switch again. Repeat until the desired position is set. Do not adjust for more drop than what was ordered. At least
1-1/2 wraps of fabric must remain on the roller.
SETTING THE UP LIMIT POSITION
CAUTION: Do not allow the slat bar to wrap over the top of the roller when the screen is rolling into the case. The screen could
be damaged.
SCREEN TRAVELS INTO CASE TOO FAR:
Turn the red limit switch screw clockwise to decrease the amount of travel. Run the screen up to test the stop
position. If the screen does not stop properly, lower the screen about one foot and turn the limit switch again.
Repeat until the desired position is set.
SCREEN DOES NOT TRAVEL FAR ENOUGH INTO CASE:
Turn the red limit switch screw counterclockwise to increase the amount of up travel. Run the screen up to test the
stop position. If more travel is desired, lower the screen about one foot and adjust the limit switch again. Repeat
until the desired position is set.
▲!
SCREEN ADJUSTMENT FOR 220/240V SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL