AutoConnect AC200GPS3G Quick Start Manual

Specifications

Brand: AutoConnect
Category: GPS
Model: AC200GPS3G (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 6

Read Online

Read the AutoConnect AC200GPS3G Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Thank-you for your purchase!

You’ve made the decision to have full control of your vehicle. Follow the steps below to begin a new era of vehicle controls. 1. Visit our website and click on the “Activate” tab, 2. Ensure you have the Serial # for your device. Once submitted you will receive a confirmation email from Northsat Distribution with the details of your device activation. and fully complete forn 3. Select YOUR model number (device type) and When installing an Autoconnect device you must first determine the installation type. The following pages will help you determine the type and instructions for installation. Choose the proper IC3 Protocol if applicable before sending any test commands 1 QUICK START GUIDE INSTALLER PORTAL DETERMINE INSTALLATION TYPE Choose proper installation location ensuring to follow instructions on install guide Determine with customer if installation is to be stealth (not visible) Have label facing the sky and clear from any metal above it. Actual location will vary by vehicle year, make and model. 2 INSTALL YOUR AUTOCONNECT GPS MODEM TEST THE DEVICE FUNCTIONS Click on the Customer Log-in icon at the top of any page of the autoconnectgps.com website or download the free App for your mobile device. Each Device comes with “TEST DATA” for you to test all functions. This data will expire a few days after installation. Use the SID# for USERNAME and PASSWORD. 3 TIP WE RECOMMEND AFFIXING THE SID STICKER TO THE DOOR JAMB OF THE VEHICLE TIP autoconnectgps.com 1 855 287 4477 Start, Lock, Unlock, open your trunk (*AC200GPS3G Only) Know the vital statistics of your vehicle(s) Request a vehicle(s) Location On-Demand Monitor vehicle(s) for Aggressive Driving and Excessive Idling Know where your vehicle(s) went, and how they got there TAKE CONTROL OF YOUR VEHICLES LIKE NEVER BEFORE! ON ALL THREE MAJOR PLATFORMS REV030617 Username Password

QUICK INSTALL GUIDE

For Live Tech Support: Call Certified Tracking Solutions at 1-780-391-3800. Toll Free 1-855-287-4477(CTS-4GPS) Monday to Friday 8AM to 5PM MST AutoConnectGPS.com Determine Installation Type and Options Attention: This modem is shipped temporarily pre-activated for the installer to send up to 50 test commands before having to send in the activation form. STEP 1: Complete the wire connections according to the selected Installation Type. STEP 2: Depending upon your requirements, the AC200GPS3G module can be installed in a variety of ways. Fortin EVO-ALL (Standalone FW) Fortin EVO-ONE Please see the following pages for detailed instructions and wiring diagrams. Failure to adhere to these suggestions will result in a weak cellular and/or GPS signal and will affect the performance of the device. - Secure in upper portion of dash in a hidden location with correct side pointing skyward .(label will indicate proper orientation) - Do not cover with metal or position near any source of interference (Vehicle Radio, BCM). Keep a safe distance of at least 24”. Blue: 2 Flashes / Second Connected / Online Green: 1 Flash / Second Valid GPS Each AC200GPS3G device is shipped pre-activated for the installer to send up to 50 test commands before having to complete the online activation form. It is HIGHLY recommended that you follow one of the test procedures below to ensure proper functionality. Alternatively you can call Certified Tracking Solutions and we will perform the test with you. Confrm LED Status STEP 4: Confrm Vehicle Connectivity and GPS location STEP 5: Position the AC200GPS3G Module in an Optimal Location STEP 3: REV022717

QUICK INSTALL GUIDE

A: via the AutoConnect website B: via the AutoConnect Smartphone App a) Go to www.AutoconnectGPS.com and click on “ Customer Login” b) Enter the AC200GPS3G’s Serial# (ESN) for both the User Name and password. c) Click Login. The AutoConnect website dashboard should load and display the Serial number of the AC200GPS3G device that you are installing. a) Download the AutoConnect Smart- phone app by searching “Autoconnect GPS” for iPhone, Android or Blackberry b) Open App and click on “Config ” then “Login” c) Enter the AC200GPS3G’s Serial# (ESN) for both the User Name and password. d) Click “Save” 1) Login to view and test the AC200GPS device Test procedure A: via the AutoConnect website B: via the AutoConnect Smartphone App 2) Test Vehicle GPS Connectivity a) Click on device serial # on the left side of the screen. The asset info box will open on the bottom left corner of the screen. b) Click on the “Asset Commands & Con- trols” icon located at the top of the Asset Info box* a) Click on the “GPS” tab b) Click on the “Bullseye” button at top left of screen The successful completion of this section will enable you to see the current position of the AC200GPS3G device on the dashboard/Smartphone map. *if using Type 2 to Type 9 please ensure you have selected appropriate data protocol

EVO-ALL & AC200GPS3G

To Optional Solace RF Kit Fortin EVO-ALL (Standalone FW) Installation Steps Programming and Testing THIS SIDE UP TOWARDS SKY T R A C K I N G S Y S T E M S www.AutoConnectGPS.com IC3 Attention: Applying 12V+ to the Brown or Blue Wire will void warranty REQUIRED DATALINK CABLE MODIFICATION* RS232 Data Port *Required if not using a T-Harness Ver 22 & UP IC3 Protocol 2 (FoRF) IC3 Firmware : IC3 Protocol Ver : Option H2 Fortin RF Bypass Program : Requirements Swap the BLUE & WHITE wires on one end of the cable or cut and reconnect. Red - 12V+ Black - Ground *Hardwiring these connections are optional for True Voltage readings. Black - Ground Red - 12V(+) White - Ignition OR Option 1 Option 2* Green - Starter Kill (-) Yellow - Input (-) Orange - Not Used Optional Connections 1. Program EVO-ALL as per Fortin installation instructions for vehicle. (Ensuring to select option H2 in Flashlink Manager) or visit http://fortin.ca/download/20101/autoconnect_evo-all.pdf 2. Complete installation as per Fortin installation diagram including the programming of the bypass module. 3. Ensure you have swapped the BLUE & WHITE wires on datalink cable between the IC3 and Fortin module. 4. Connect Data link cable from IC3 to RS232 port on EVO-ALL (Ports are interchangeable on IC3). Connect Power and Ground if not using a T-Harness. 5. For true voltage cut and hardwire the Red, Black, and White directly from the Autoconnect device to the vehicle. *DO NOT CUT THE DATALINK CABLE 8. Program the Autoconnect to Fortin module by performing the following: -Hold programming button while inserting datalink cable to EVO-ALL. Release button when Blue & Red LED’s Turn on -Press and hold the programming button on the EVO-ALL (The LED’s will turn of then back on approx 5 seconds), release button -Turn Ignition ON (ALL 3 LED’s should be on now) -Send the Lock command from the Autoconnect. The Blue and Red LED’s should fash once. -Turn Ignition OFF 1. Open the Autoconnect App or Dashboard 2. Log in to the Autoconnect device installed using the SID # as both username and password. 3. Go to the command tab on the bottom of the app, or the remote funciton of dashboard 6. Scroll to the bottom of the commands and send the required Installer Protocol. 7. For Fortin EVO-ALL select IC3 Protocol 2 (FoRF) 9. Mount the Autoconnect module as described in Autoconnect Install. 4. Test all the application functions (Start, Stop, Lock, Unlock, Auxiliaries, ETC. GPS). 5. We reccomend afxing the SID Sticker to the door jamb of the vehicle. *CABLE TO BE MODIFIED

EVO-ONE & AC200GPS3G

Fortin EVO-ONE Installation Steps Programming and Testing THIS SIDE UP TOWARDS SKY T R A C K I N G S Y S T E M S www.AutoConnectGPS.com IC3 Attention: Applying 12V+ to the Brown or Blue Wire will void warranty RF PORT 1. Program EVO-ONE as per Fortin installation instructions for vehicle (Ensuring to select option H2 in Flashlink Manager) or visit http://fortin.ca/download/26701/autoconnect_evo-one.pdf 2. Complete installation as per Fortin installation diagram. 3. Ensure you have swapped the BLUE & WHITE wires on datalink cable between the IC3 and Fortin module. 4. Connect Data link cable from IC3 to BLUE RF PORT on EVO-ONE (Ports are interchangeable on IC3). 5. For true voltage cut and hardwire the Red, Black, and White directly from the Autoconnect device to the vehicle. *DO NOT CUT THE DATALINK CABLE 8. Program the Autoconnect to Fortin module by performing the following: -Turn Ignition On. -Press and hold the Valet switch until LED fashes then release. Then press Valet switch 5x. -Press and release the brake pedal. -Send the Lock command from the Autoconnect. The park lights will fash once to confrm. -Press and release the brake pedal then turn igntion OFF. 1. Open the Autoconnect App or Dashboard 2. Log in to the Autoconnect device installed using the SID # as both username and password. 3. Go to the command tab on the bottom of the app, or the remote funciton of dashboard 6. Scroll to the bottom of the commands and send the required Installer Protocol. 7. For Fortin EVO-ONE select IC3 Protocol 2 (FoRF) 4. Test all the application functions (Start, Stop, Lock, Unlock, Auxiliaries, ETC. GPS). 5. We reccomend afxing the SID Sticker to the door jamb of the vehicle. *Hardwiring these connections are optional for True Voltage readings. Black - Ground Red - 12V(+) White - Ignition OR Option 1 Option 2* REQUIRED DATALINK CABLE MODIFICATION Swap the BLUE & WHITE wires on one end of the cable or cut and reconnect Green - Starter Kill (-) Yellow - Input (-) Orange - Not Used Optional Connections Ver 22 & UP IC3 Protocol 2 (FoRF) IC3 Firmware : IC3 Protocol Ver : Option H2 Fortin RF Bypass Program : Requirements *CABLE TO BE MODIFIED To Optional Solace RF Kit 9. Mount the Autoconnect module as described in the Autoconnect Install guide Step 3.

FW Verison Number

eg, 2 quick then 2 quick = Ver 22 Slow fashes Data Protocol Version eg, 5 Flashes = IC3 Data Protocol 5 (SO/TI) Solid ON = Ignition ON Solid OFF = Ignition OFF FLASHING 1 Flash = AC200 to Device 2 Flashes = Device to AC200

Other GPS Manuals