microSYST migan BCD Operation & User’s Manual

Specifications

Brand: microSYST
Category: Monitor
Model: migan BCD (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 13

Read Online

Read the microSYST migan BCD Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach

 +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de migan BCD Large Display Numeric LED with BCD Inputs User Manual

Large Display Numeric LED with BCD Inputs

Page 2 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de Index 1 GENERAL 3 2 SYSTEM OVERVIEW 3 3 TECHNICAL INFORMATION 3 3.1 Notes for the start-up 3 3.2 Device Configuration 4 3.3 Overall Specification 5 3.4 Control Signals 6 3.5 Impulse Diagram (multiplex operation) 7 3.6 Connector Pin Assignments 8 3.7 DIP Switches 9 4 APPENDIX 10 4.1 Maintenance and Care 10 4.2 Declaration of Conformity 11 4.3 Warranty / Liability 12 4.4 Versions Overview 13

Large Display Numeric LED with BCD Inputs

Page 3 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 1 General The large format numeric display can be used universally as a production display unit or as an information board. The modular design allows for cost-effective models of various sizes, and with different character heights and numbers of digits. Thus integration into existing equipment or systems is easy and simple. 2 System Overview The display is controlled with BCD inputs. 3 Technical Information 3.1 Notes for the start-up  When putting on the power supply, the following sequence has to be observed: o Connect the power supply cable to the display. o Connect the power supply cable to the power supply.  When disconnecting the power supply, the following sequence has to be ob- served: o Disconnect the power supply cable from the power supply. o Disconnect the power supply cable from the display. BCD coded inputs

Large Display Numeric LED with BCD Inputs

Page 4 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 3.2 Device Configuration Type: for inside use for outside use Character height: 60 mm 100 mm 150 mm 200 mm 250 mm 300 mm Number of lines: ________ Number of digits per line: ________ Display colour: red green __________ Dimensional Display: Line 1: __________ Line 5: __________ Line 2: __________ Line 6: __________ Line 3: __________ Line 7: __________ Line 4: __________ Line 8: __________ View: single sided double sided quadruple sided Operating Voltage: 230 V / 50 Hz 110 V / 60 Hz 24 V DC Protection: IP54 IP65 IP _____ Operating temperature: 0 to +50 °C -20 to +50 °C -25 to +50 °C ___________°C Housing dimensions: _________x_________x_________mm Housing Material: Aluminum profile Stainless steel Sheet metal Controlling: BCD parallel BCD multiplex

Large Display Numeric LED with BCD Inputs

Page 5 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 3.3 Overall Specification migan for indoor use migan for outdoor use Display type 7 segment LED 7 segment single LED, pixel size: 5.2 x 3.8 mm (oval) Angle of radiation n/a 110°/50° (horizontal/vertical) Character height 60 / 100 / 150 / 200 / 250 mm 100 / 200 / 300 mm Digits 1 to 4 / 6, optional 8 / 12 Number of lines standard 1 line, multiple lines on request Display colour standard: red; optional: green Light intensity n/a red > 3100 cd/m², green > 3720 cd/m², Brightness control n/a automatically Operating voltage 230 VAC / 50 Hz, 110 VAC / 60 Hz or 24 VDC ±20% View single sided to four sided Interface BCD, multiplex or parallel Input level Ulow 0 to 4 VDC, Uhigh 11 to 30 VDC Displayable characters 0 to 9, H, E, L, P, -, Blank, . 0 to 9, H, E, L, P, -, Blank, .(*) *decimal point only possibile at numerals Labelling upon request Housing industrial version, powder coated aluminum Housing colour RAL 7016 (anthracite) Mounting articulated arm, angle bracket, hanging with chain or mounting frame Protection IP54 or IP65 IP65 for outdoor use Operating temp. 0...+50 °C standard: -20...+50 °C, optional with heating: -25 to +50 °C Storage temperature -25...+70 °C Parallel BCD Four data transmission lines are required for the control of each digit. The display of values requires static data entry in BCD code. Multiplex BCD The multiplex BCD operating mode is recommended for the display of multiple digits. Data transmission lines are set up as a 4-bit bus.

Large Display Numeric LED with BCD Inputs

Page 6 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 3.4 Control Signals The following comments describe the default settings of the standard product. Special requests of the customer can usually be complied. This means, the following descrip- tion could differ from the delivered product. BCD parallel/BCD multiplex Input Display LE BI LT D C B A 0 1 1 0 0 0 0 0 0 1 1 0 0 0 1 1 0 1 1 0 0 1 0 2 0 1 1 0 0 1 1 3 0 1 1 0 1 0 0 4 0 1 1 0 1 0 1 5 0 1 1 0 1 1 0 6 0 1 1 0 1 1 1 7 0 1 1 1 0 0 0 8 0 1 1 1 0 0 1 9 0 1 1 1 0 1 0 H* 0 1 1 1 0 1 1 E* 0 1 1 1 1 0 0 L* 0 1 1 1 1 0 1 P* 0 1 1 1 1 1 0 „Space“* 0 1 1 1 1 1 1 -* x x 0 x x x x 8. x 0 1 x x x x no display 1 1 1 x x x x # 0=LOW signal, 1=HIGH signal LE = 1 = Keep the last display. 0 = Adopt the current BCD data and display it. # = The display depends on the data, which were applied before the rising edge of LE. The data must not be changed 2 ms before the rising edge! x = any state * = These characters are only displayed, if the internal DIP switch S1-4 is in ON position, otherwise this digit is deleted. At migan displays for outside use, no decimal points are possible in combination with these characters.

Large Display Numeric LED with BCD Inputs

Page 7 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de LT input (lamp test) The lamp test is performed with a “LOW” signal at the “LT” input. Then, all availa- ble segments are controlled. Decimal Point Input The decimal points of the digits can be controlled separately by connecting to a “HIGH” signal to the corresponding input. Blank Input The display is dark-switched with a „HIGH“ signal at the blank input. Open Inputs If inputs are not connected, a particular standard level is read in: Input Standard level A (20) B (21) C (22) D (23) LOW (0) LOW (0) LOW (0) LOW (0) LE LOW (adopt the data) LT HIGH (no lamp test) Dec. point LOW (no decimal point) Blank HIGH (no blanking) 3.5 Impulse Diagram (multiplex operation) A...D LE 100  2 ms LE 101 LE 102 LE 103 LE 104 LE 105 100 101 102 103 104 105 t

Large Display Numeric LED with BCD Inputs

Page 8 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 3.6 Connector Pin Assignments Input (25-Pole Sub-D Plug Connector) Parallel BCD Multiplex BCD 1 GND 14 Data 21/101 1 GND 14 Blank /102 2 n.c. 15 Data 22/101 2 n.c. 15 LE /101 3 Data 20/103 16 Data 23/101 3 LE /105 16 Dec.point /101 4 Data 21/103 17 Dec.point /101 4 Dec.point /105 17 Blank /101 5 Data 22/103 18 Data 20/100 5 Blank /105 18 LE /100 6 Data 23/103 19 Data 21/100 6 LE /104 19 Dec.point /100 7 Dec.point/103 20 Data 22/100 7 Dec.point /104 20 Blank /100 8 Data 20/102 21 Data 23/100 8 Blank /104 21 Data 20 9 Data 21/102 22 LE 9 LE /103 22 Data 21 10 Data 22/102 23 Blank 10 Dec.point /103 23 Data 22 11 Data 23/102 24 LT 11 Blank /103 24 Data 23 12 Dec.point /102 25 n.c. 12 LE /102 25 LT 13 Data 20/101 13 Dec.point /102

Large Display Numeric LED with BCD Inputs

Page 9 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de Power Connector 230 VAC Power Connector 24 VDC (optional) 3.7 DIP Switches The DIP switches of the internal BCD board have already the right settings and must not be changed by the user! Pin Assignment 1 L1 2 N (PE) PE Pin Assignment 1 GND 2 +24 VDC 3 PE

Large Display Numeric LED with BCD Inputs

Page 10 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 4 Appendix 4.1 Maintenance and Care Please observe the following instructions:  Make sure that the housing can be opened for adjustment and mainte- nance even after the display has been installed. Allow for adequate clear- ance at the back, front and top of the display unit in order to allow for suf- ficient ventilation (if vent slots are included).  Display quality is impaired by direct illumination with bright light sources and/or direct sunlight.  The display must be switched off before cleaning.  Protect the display from excessive humidity, extreme vibration, direct sun- light and extreme temperatures. Non-observance may lead to malfunc- tioning or destruction of the device. Under certain circumstances electrical shock, fire and explosion may occur as well. Information concerning al- lowable ambient conditions, including recommended temperature ranges, can be found in the chapter entitled “Technical Information”.  The display may not be placed into service if the device and/or the power cable are damaged.  Do not attempt to repair the device yourself. The guarantee is rendered null and void if unauthorized persons tamper with the device.

Large Display Numeric LED with BCD Inputs

Page 11 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 4.2 Declaration of Conformity EU-Konformitätserklärung EU Declaration of Conformity Produktbezeichnung: migan Product name: Typenreihe: migan BCD Type code: Hersteller: microSYST Systemelectronic GmbH Manufacturer: Am Gewerbepark 11 92670 Windischeschenbach Das bezeichnete Produkt stimmt mit der folgenden Europäischen Richtlinie überein: We herewith confirm that the above men- tioned product meets the requirements of the following standard: Die Übereinstimmung des bezeichneten Produk- tes mit den Vorschriften der angewandten Richt- linie(n) wird nachgewiesen durch die Einhaltung folgender Normen / Vorschriften: The conformity of the product described above with the provisions of the applied Directive(s) is demon- strated by compliance with the following standards / regulations: Richtlinien / Directives Europäische Norm / Standard EMV Richtlinie EMC Directive 2014/30/EU EN61000-6-2:2005 EN61000-6-4:2007 +A1:2011 Niederspannungs- Richtlinie Low Voltage Directive 2014/35/EU EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 RoHS Richtlinie RoHS Directive 2011/65/EU EN50581:2012 Windischeschenbach, 20.11.2017 Manuel Raß Geschäftsführer / General Manager

Large Display Numeric LED with BCD Inputs

Page 12 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 4.3 Warranty / Liability For the product, liability is assumed for defects, which existed at the delivery date according to our General Terms and Conditions. Technically changes as well as errors are excepted. A claim for delivery of a new product does not exist. The buyer has to check the received product im- mediately and indicate evident defects at the latest 24 hours after detection. Non-observance of notification requirements is equated with acceptance of the defect. Not immediately visible defects have to be indicated immediately after their perception too. Generally, defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and elimination. The buyer must provide for access to the relevant device and all required and/or useful infor- mation at no charge and must make all of the required data and machine time available free of charge. The guarantee does not cover defects, which result from non-observance of the prescribed conditions of use, or from improper handling. If the device has been placed at the disposal of the buyer for test purposes and has been purchased subsequent to such testing, both parties agree that the product is to be considered “used” and that it has been purchased “as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well.

Large Display Numeric LED with BCD Inputs

Page 13 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, [email protected], www.microsyst.de 4.4 Versions Overview Version Date Remark, Description 1.00 1.10 1.20 1.30 1.40 2013-05-14 2013-10-17 2014-01-22 2016-04-27 2017-11-20 Document created, based on X-M32-BSXXBX-001: display type, character heights changed Logo migan 2 -> migan Declaration of conformity Change of address Certified per DIN EN ISO 9001.