GO Systemelektronik BlueBox Manual 

Specifications

Brand: GO Systemelektronik
Category: Control Unit
Model: BlueBox (Manual )
File Type: PDF
File Size: —
Pages: 77

Read Online

Read the GO Systemelektronik BlueBox Manual  online using the built-in PDF viewer.

Text of the manual

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 2 / 77 www.go-sys.de [email protected] Copyright This Manual contains information which is the intellectual property of GO Systemelektronik GmbH. The user is obliged to use this information exclusively to run the instrument. It is not permitted to pass this information to third parties. Reproducing, copying, editing or extracting the manual contents is only allowed with the ex- press permission of GO Systemelektronik GmbH. Changes GO Systemelektronik GmbH retains the right to modify the contents of the manual without prior notice. Liability Exclusion GO Systemelektronik GmbH takes no responsibility for correct system operation under all possible operating conditions. It is not possible to guarantee that the software will function completely without error under all possible circumstances. GO Systemelektronik GmbH cannot therefore accept liability for direct or indirect damage resulting from system operation or the contents of this manual. Product Observance Within the scope of our obligation for product observance GO Systemelektronik GmbH will endeavour to warn third parties about all identified dangers which could arise from the interaction between hardware and software and from the use of other components. Effective product observance is only possible with ade- quate information from the end user about the planned field of application and the hardware and software used. If the conditions of use change or if the hardware or software are changed, due to the complex rela- tionships between hardware and software it is no longer possible to describe all possible dangers and their effects on the total system, in particular on our system. This manual does not describe every possible prop- erty and combination of the system. For further information, please contact GO Systemelektronik GmbH. Manufacturer's declaration In setting up the device it is important amongst other things to note the correct electrical connections, protec- tion against connections to foreign bodies, humidity, protection against excessive moisture due to condensa- tion and to the overheating of the device in proper and improper use. The implementation of these measures is the responsibility of the installers who setup this device. valid from firmware version: 2.76.11 file name: BDA_BlueBox_V5p3_en.pdf © GO Systemelektronik GmbH Faluner Weg 1 D- 24109 Kiel Germany Tel.: 0431/58080-0 Fax: 0431/58080-11 http://www.go-sys.de [email protected]

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 3 / 77 www.go-sys.de [email protected] Table of contents 1 Properties and functions of the BlueBox .......................................................................................................................... 5 1.1 Essential properties of the system ............................................................................................................................. 5 1.2 Technical data ........................................................................................................................................................... 6 2 Before installation ............................................................................................................................................................. 7 2.1 Safety notices and warnings ...................................................................................................................................... 7 2.2 Basic equipment for operation ................................................................................................................................... 7 3 Installation ........................................................................................................................................................................ 8 3.1 Mounting of the BlueBox ........................................................................................................................................... 8 3.2 Connection options .................................................................................................................................................... 9 3.21 Connector pin assignment at the BlueBox ........................................................................................................ 10 3.3 Connecting of the power supply .............................................................................................................................. 11 3.4 LAN-connection ....................................................................................................................................................... 12 3.5 CAN-bus termination and RS-485 termination at the BlueBox ................................................................................ 13 3.6 Jumper position RS-232 or RS-485 ......................................................................................................................... 13 4 Connection of sensor and actuator modules .................................................................................................................. 14 4.1 Connection via M12 male plug ................................................................................................................................ 15 4.1.1 Mounting of the M12 male plug at the CAN-bus cable ..................................................................................... 15 4.2 Connection via spring clips ...................................................................................................................................... 16 4.3 Termination of the CAN-bus .................................................................................................................................... 17 4.4 Checking the Termination ....................................................................................................................................... 18 5 Connection of the CAN-bus repeater ............................................................................................................................. 19 6 The configuration data sheet .......................................................................................................................................... 20 7 Switching on the BlueBox and password input ............................................................................................................... 22 8 The menu operation ....................................................................................................................................................... 25 8.1 Parameter display ................................................................................................................................................... 25 8.1.1 Single parameter display .................................................................................................................................. 25 8.1.2 Multiple parameter display ............................................................................................................................... 26 8.2 Main menu ............................................................................................................................................................... 27 8.2.1 System menu ................................................................................................................................................... 28 8.2.1.1 Network Menu ........................................................................................................................................... 29 8.2.1.1.1 IP-Address menu ................................................................................................................................ 30 8.2.1.1.2 Netmask menu ................................................................................................................................... 31 8.2.1.1.3 Gateway IP-Address (default gateway) .............................................................................................. 32 8.2.1.1.4 Input timeserver .................................................................................................................................. 33 8.2.1.1.5 Internet settings .................................................................................................................................. 34 8.2.1.1.5.1 UDP settings ................................................................................................................................ 35 8.2.1.1.5.1.1 Setting IP address (UDP) ..................................................................................................... 36 8.2.1.1.5.1.2 Determine the password of the encryption ........................................................................... 37 8.2.1.1.5.2 Gateway settings (Internet) .......................................................................................................... 38 8.2.1.1.5.2.1 Input gateway settings (Internet) .......................................................................................... 39 8.2.1.1.5.3 DynDNS settings ......................................................................................................................... 40 8.2.1.1.5.3.1 Input DynDNS settings ......................................................................................................... 41 8.2.1.1.6 Info Network ....................................................................................................................................... 42

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 4 / 77 www.go-sys.de [email protected] 8.2.1.2 Time menu ................................................................................................................................................ 42 8.2.1.2.1 Date menu .......................................................................................................................................... 43 8.2.1.2.2 Time menu ......................................................................................................................................... 44 8.2.1.2.3 Time zone menu ................................................................................................................................. 45 8.2.1.2.4 Time drift menu .................................................................................................................................. 45 8.2.1.3 Shutdown .................................................................................................................................................. 46 8.2.1.4 Modem menu / Modem settings ................................................................................................................ 47 8.2.1.4.1 Modem port setup ............................................................................................................................... 48 8.2.1.4.2 Input of the PIN number .................................................................................................................... 49 8.2.1.4.3 Modem type settings .......................................................................................................................... 50 8.2.1.4.4 UMTS settings .................................................................................................................................... 51 8.2.1.4.4.1 Input UMTS settings .................................................................................................................... 52 8.2.1.4.5 Modem Info (UMTS) ........................................................................................................................... 52 8.2.1.5 GPS Menu ................................................................................................................................................. 53 8.2.1.5.1 GPS Port Setup .................................................................................................................................. 53 8.2.1.6 Display ....................................................................................................................................................... 54 8.2.1.7 Language settings ..................................................................................................................................... 55 8.2.2 Sensor list ........................................................................................................................................................ 56 8.2.3 Sensor menu .................................................................................................................................................... 57 8.2.3.1 Interval and Average ................................................................................................................................. 58 8.2.3.2 Calibration ................................................................................................................................................. 59 8.2.3.3 Table display (sensor values) .................................................................................................................... 60 8.2.3.4 Diagram display (sensor values) ............................................................................................................... 61 8.2.3.5 Sensor info ................................................................................................................................................ 62 8.2.3.6 Selection calibration mode ........................................................................................................................ 63 8.2.4 User variables .................................................................................................................................................. 64 8.2.5 Actuator list ...................................................................................................................................................... 65 8.2.5.1 Actuator menu ........................................................................................................................................... 66 8.2.5.1.1 Actuator setting .................................................................................................................................. 67 8.2.5.2 Diagram display (actuator) ........................................................................................................................ 68 8.2.5.3 Actuator info .............................................................................................................................................. 68 8.2.6 Help menu ........................................................................................................................................................ 69 8.2.6.1 Info menu of the system ............................................................................................................................ 69 8.2.6.2 Plug and clip connection ........................................................................................................................... 70 Appendix A - Adjustment of the touch display ................................................................................................................... 71 Appendix B - Calibrating a pH sensor ............................................................................................................................... 72 Appendix C - Calibration of an oxygen sensor .................................................................................................................. 73 Appendix D - Example configuration BlueGate-Server ..................................................................................................... 74 Appendix E - Update of the BlueBox firmware .................................................................................................................. 75 Appendix F - Opening a BlueBox housing ........................................................................................................................ 76 Appendix G - Status and error messages ......................................................................................................................... 77

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 5 / 77 www.go-sys.de [email protected] 1 Properties and functions of the BlueBox The BlueBox is the central element of the BlueBox-System. The BlueBox-System is a modular designed measurement and control system. The BlueBox is connected via CAN (Controller Area Network) technology with sensors and actuators. For data processing and communication the BlueBox is equipped with the common interfaces. 1.1 Essential properties of the system • Due to its modular structure the BlueBox system can handle almost every conceivable measurement and control tasks. • A BlueBox can be connected with up to 200 sensors or actuators. The connection takes place via sensor modules1 and actuator modules1 (output modules). • In addition to sensors and actuators from our own product range, we also integrate products of almost all other manufacturers. • The sensor-actuator modules and can be used in bus or star ciruit configuration2 decentralized over dis- tances of up to 1000 meters (optionally longer). • Measurement transfer and communication takes place via Ethernet, Internet, cellular radio3 (UMTS), telephone line (ISDN, analogue), EMC or Modbus (RS-232 / RS-485), current outputs3 (4 – 20 mA). • In mobile use it is possible to the connect the BlueBox with a GPS for the continuous position determi- nation. 1 It is possible to connect multiple sensors/actuators to a sensor module. 2 A star circuit can only be used with a repeater (see 5 Connection of the CAN-bus repeater). 3 optional

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 6 / 77 www.go-sys.de [email protected] 1.2 Technical data Computer: PC 104, 200 MHz to 500 MHz Operation system Linux® Random access memory 256 MB (optional 512 MB) Display: Touchpanel 240x128 pixel Storage media: Industrial Compact Flash Card 2 GB; 512 MB; 256 MB Mechanical data: Housing dimensions: 280 mm x 170 mm x 90 mm (W x L x H) Weight: approx. 2,6 kg Protection class: IP 65 Die-cast aluminum housing, powder coated Colour: RAL 5010 Power supply: Nominal voltage: 24 V DC (18 V – 28 V) ∗ Nominal power: 10 W, additionally max. 1 A at the output to the modules Interfaces: 1 x RS-232 or RS-485 (half-duplex) 1 x CAN 1 x Ethernet 10/100MBit 1 x USB optional: 2 x current output 4 mA – 20 mA Modem: optional: Modem UMTS optional: Modem ISDN/analogue Ambient conditions: Ambient temperature: Storage: -25 °C to +50 °C Operation: -20 °C to +45 °C avoid direct sunlight Relative humidity ≤ 90 % (annual average) To ensure equipment protection and the proper functioning of the device, the above conditions are strictly to be adhered to! ∗ The connected modules receive their power from the BlueBox. Some modules have a constricted input range, so there is a input voltage tolerance of ± 10%. Article-No. 486 0003

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 7 / 77 www.go-sys.de [email protected] 2 Before installation 2.1 Safety notices and warnings Please read the manual carefully before using the BlueBox. Keep this also within easy reach. Pass the BlueBox never without the manual to other people. The manufacturer is not liable for improper use. This unit is designed with Low Voltage Directive and the safety regulations for electronic devices. The trouble-free operation and reliability can only be assured if you pay attention to the generally applicable safety measures and special safety instructions in this manual . • Before the connection of the Blue Box to the power supply make sure that the labeled BlueBox operating voltage matches the supply voltage (indicating the areas of power supply). • The correct functioning and operational safety of the device can only be ensured, if the ambient condi- tions that are specified in the section 1.2 "Technical data" are complianced. • If the device is transported from a cold to a warm environment condensation may result in a failure of the function. In this case, wait until the device temperature is at the level of the ambient temperature before a new start-up. • Maintenance and repair work may only be performed by a specialist who is authorized by GO Systeme- lektronik. If you assume that the device can no longer be operated safely, it is taken out of service and avoid re- starting. The safety may be compromised by the device if, for example, the device: • has visible damages, • no longer works as required, • has been stored in improper conditions for a longer time, • was exposed to improper transport conditions. In cases of doubt give notice to GO Systemelektronik GmbH . If necessary send the device to GO Systeme- lektronik for reparation respectively maintenance. 2.2 Basic equipment for operation To operate the BlueBox in a meaningful way, a basic equipment is required: 1 x BlueBox 1 x CAN connection cable with a matching cable plug 1 x 24 V DC power supply unit with a connection cable to the BlueBox (43 W or 108 W) 1 x Sensor module or actuator module with connected sensor/actuator

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 8 / 77 www.go-sys.de [email protected] 3 Installation 3.1 Mounting of the BlueBox Before mounting the BlueBox check the scope of delivery for completeness: (this is an example for a minimum delivery scope without power supply and without sensor-/actuatormodule) 1. BlueBox 2. Manual BlueBox 3. Configuration data sheet 4. Drilling template Be careful when choosing the location of the BlueBox, the location has to achieve the following properties: • rain-and sun-protected location • convenient location for a mobile network coverage, if the Blue Box is used with an optional modem∗ The Blue Box should be mounted on a vertical surface. The drilling template is used for mounting on a flat surface. Please choose suitable mounting screws and dowels, which are suitable for the material of the mounting surface. Remove the covers on both sides of the BlueBox. Below you see the holes for the mounting screws. Despite the construction of the BlueBox in protection class IP 65you have to install the measuring instrument in a rain-and sun-protected site. If this is not possible, the BlueBox must be mounted in an additional housing. A great advantage of the BlueBox is their design flexibility. Therefore construction of installation will vary by application. A description of the structure and assembly of the BlueBox can only serve as an example. ∗ UMTS, ISDN, analogue 1 2 3 4

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 9 / 77 www.go-sys.de [email protected] 3.2 Connection options The BlueBox has the following connection options: 1. Ground connection 2. Power supply (24 V DC) via a 5-pin M12 panel plug (male) 3. Connection CAN-bus via a 5-pin M12 panel jack (female) CAN-bus connection to the BlueBox sensor-/actuator modules via 4-wire CAN-Bus connection cable 4. USB connection Please note: The USB port on the BlueBox is provided for data storage and update the firmware. 5. LAN port for LAN cables in standard or cross-link design (see also 3.4). 6. Connection serial interface via a 3-pin M8 panel plug (male), RS-232 or RS-485 7. Connection current output∗ 4 to 20 mA via a 4-pin M8 panel jack (female) 8. Connection current output* 4 to 20 mA via a 4-pin M8 panel jack (female) 9. Hole for an antenna or cable modem Modems (optional): • UMTS modem with antenna • analogue modem • ISDN modem ∗ optional 1 2 3 4 6 5 7 9 8

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 10 / 77 www.go-sys.de [email protected] 3.21 Connector pin assignment at the BlueBox Power supply 24 V DC panel plug (M12, male) 3 +24 V DC 4 GND 24 V CAN-bus panel jack (M12, female) 1 CAN-H 2 CAN-L 3 +24 V DC 4 GND 24 V RS-232 or RS-485 panel plug (M8, male) RS-232 1 GND GND RS-485 3 RX RX/TX- 4 TX RX/TX+ Current output 4 – 20 mA (optional) panel jack (M8, female) 1 +24 V DC 2 I-Return 4 3 1 2 3 4 1 4 3 2 1

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 11 / 77 www.go-sys.de [email protected] 3.3 Connecting of the power supply For connecting the power to the BlueBox you need an external power supply. The power supply is available in two versions: Power supply for the BlueBox (48 806 K00 00 A1), 43 W Power supply for the BlueBox (48 806 K00 00 B1), 108 W The BlueBox should only be installed by a qualified person using suitable tools. Incorrect installa- tion can result in serious malfunction and could damage the instrument. Compare the BlueBox data for voltage and frequency with the available supply before connecting the power. Please notice that the power supply unit is placed close to the BlueBox because the voltage is declining with the length of the connecting cable. Please notice that it is necessary to use the appropriate conductor cable for the environment. In the outside area it is advisable to use a rubber cable that is approved for the usage site. The cable jack located on the 24 V DC cable is to stuck in an unambiguous way in the corresponding panel plug of the BlueBox. 24 V DC cable 220 V AC cable

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 12 / 77 www.go-sys.de [email protected] 3.4 LAN-connection The LAN port allows the connection of the Blue Box to a Local Area Network or directly to a PC. Thus, a retrieval of data and direct communication with the BlueBox is possible. This requires the installation of the BlueBox PC software on your local computer (see Manual BlueBox PC Software). The connection to a network is made by a RJ-45-connector at the bottom of the BlueBox (see also 3.2 Con- nection options). For this connection you have to choose one of two different connecting cables. • For connecting to a network you need a standard RJ-45 cable. • For connecting to a PC you need a RJ-45-crosslink cable. (Only if the PC has no automatic switch of the network interface.) Please ensure that the RJ-45-plug snaps into the socket with a “click”! If the closing cannot be inserted on the socket, please put vaseline on the rubber seal and try it again care- fully. Precondition for the protection class IP65: • tightly twisted connector with protection class IP65 or higher on the CAN-bus and power connection∗ • fitted caps on the USB and LAN connection or • USB or LAN connector with protection class IP65 or higher. ∗ The delivered plugs from GO Systemelektronik have the protection class IP65.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 13 / 77 www.go-sys.de [email protected] 3.5 CAN-bus termination and RS-485 termination at the BlueBox The CAN-bus termination is factory preset to ON.1 If you need to change the termination, open the housing2 and set the respective termination switch to either ON or OFF. 3.6 Jumper position RS-232 or RS-485 The BlueBox is factory preset to RS-232 unless requested otherwise by the customer. If you need to change the jumper positions, open the housing and place the jumpers correspondingly. 1 If the BlueBox is configured to RS-485 by GO Systemelektronik, its termination is factory preset to ON. 2 see Appendix F - Opening a BlueBox housing

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 14 / 77 www.go-sys.de [email protected] 4 Connection of sensor and actuator modules The connection of sensor- or actuator modules to the BlueBox is made by CAN∗ (Controller Area Net-work). The connection at the BlueBox is a M12-male-socket (see 3.2) In the most cases the CAN-network is built as a line-structure. At other structures the topology of the network has to be conform to CAN-bus. In a line structure the first and the last unit must be terminated (see section 4.3 Termination of the CAN-bus). connection diagram sensors/actuators ∗ The CAN-bus (Controller Area Network) is an asyn- chronous serial bus system and belongs to the field- bus. To connect a sensor-/actuator module with the BlueBox insert the M12 male plug from the CAN-connection cable into the M 12 female socket at the BlueBox. The other end of the CAN-connection cable can be connected to a sensor-/actuator module in two ways: 1. Connection with M12 male plug, see 4.1 Note the correct PIN assignment of the male plug using the pin label. When using a cable of the type LiYCY 2x2x0, 5 mm ² (article no. 339 0001), the color coding ap- plies to the table below. 2. Connection with spring clips, see 4.2 Note the correct terminal connections using the circuit board label. When using a cable of the type LiYCY 2x2x0.5 mm² (article no. 339 0001), the color coding ap- plies to the table below. color coding cable type LiYCY 2x2x0.5 mm² (article no. 339 0001) PIN no. Clip no. color coding function 1 green (GN) CAN-High 2 yellow (YE) CAN-Low 3 white (WH) +24 V DC 4 brown (BN) 24 V GND BlueBox T2 and elder: If no module is connected, the BlueBox is not detected from the BlueBox PC software. Error message: Socket Error # 10061/Connection refused)

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 15 / 77 www.go-sys.de [email protected] 4.1 Connection via M12 male plug As an example of connecting a sensor-/actuator module using a 4-pin cable and two M12 connec- tors in the following the connection of a pH sensor as a final module is shown. At the bottom of the sensor housing is a four-pin M12 socket. In this the four-pin M12 male plug off the CAN connec- tion cable is inserted and fixed by turning the un- ion nut. sensor connection via M12-connector (final module) If the sensor module should be connected as a pass module it is made by using a Y-splitter. sensor connection via Y-splitter (pass module) 4.1.1 Mounting of the M12 male plug at the CAN-bus cable 1. Remove the coating of the cable (approx. 40 mm) 2. Put the preas- sembled union nut on the cable as far as it will go. 3. Put the cable strand in the marked guidance (configuration see the table on the previous page). 4. Cut off the over- laying end of the cable strand. exemplary connection of a M 12 plug with a 4-PIN cable CAN-bus connecting cables or connectors can be ordered by us under the following article numbers. Article no.: Cable for data and supply 339 0001 M 12 male plug 338 1100 M 12 Y-splitter 338 1500 earthing optional sensor connection pH sensor

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 16 / 77 www.go-sys.de [email protected] 4.2 Connection via spring clips The CAN-bus connecting cable will be brought inside the housing through a grommet and con- nected to a socket connector that plugs into the header of the CAN-bus connection (1). The clamps are suitable for wire cross sections between 0.5 and 2.5 mm². The cable has to be isolated until a length of 9 or 10 mm. The cable strand is put in the clamp how described in the following: Please push down the spring with a suitable screw driver underneath the upper hole (3) in which the cable bared will be insert (2). Remove the screw driver from the spring. sensor connection with spring clips (final module) The cable strand should be connected with the clamp. Please check this by an easy traction at the cable. If it is not, repeat the procedure. If not all cable grommets in the hous- ing are required, make sure that the unused cable entries must be sealed with plugs. Only then the housing has the protec- tion class IP 65. Below is shown how a sensor on the spring clip as a pass module will be connected. In this case the CAN-bus cable that goes to the next module has to be connected with a row of the spring clip plug. Please attend to the correct colour coding. sensor connection via spring clamps (pass module) color coding cable type LiYCY 2x2x0.5 mm² (article no. 339 0001) PIN no. Clip no. color coding function 1 green (GN) CAN-High 2 yellow (YE) CAN-Low 3 white (WH) +24 V DC 4 brown (BN) 24 V GND 1 2 3

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 17 / 77 www.go-sys.de [email protected] 4.3 Termination of the CAN-bus It is important to “terminate” the specific modules in the right way. Physical this means, that a mod- ule at the beginning or the end of a bus has to be endued with a closing resistor. With this “termina- tion” the CAN-bus is closed, this prevents signal reflections and signal interference. Modules that are inside of a bus (pass modules) may accordingly have no terminating resistor. schematic representation of the CAN-bus line structure, example The on- and off-switching of the terminating resis- tor is done with a DIP switch. This DIP switch is located in the module housing next to the con- nection clamps of the sensors and is labeled "Termination". The termination is switched on when the DIP switch in position "ON". The termination is switched off when the DIP switch in position "OFF". At the BlueBox itself, the termination resistor can also be switched on and off. Here too, the DIP switch is located next to the terminal to the cable leading from the M12 connector on the mother- board. Because the BlueBox is in the majority of installations at the beginning of the CAN-bus, the BlueBox is terminated at the factory, i.e. the ter- mination resistor is switched on. If the Blue Box is in the middle of a CAN-bus, the termination of the BlueBox must be switched off. see: 3.5 CAN-bus termination and RS-485 termination at the BlueBox DIP switch on position „ON“, the termination resistor is switched on. The device is a final module. DIP switch on position „OFF“, the termination resistor is switched on. The device is a pass module. Termination CAN - Bus OFF ON X1 1 CAN - H 2 CAN - L 3 +24V 4 24V GND 1 2 3 4 5 6 X1 Termination CAN - Bus OFF ON X1 1 CAN - H 2 CAN - L 3 +24V 4 24V GND 1 2 3 4 5 6 X1

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 18 / 77 www.go-sys.de [email protected] 4.4 Checking the Termination Please take notice of the correct termination of the single modules to assure a correct performance of the CAN-bus. The termination can be controlled by measuring the resistance between CAN-High and CAN-Low with a multimeter. The measurement can be done at any device of the CAN-bus-system. The easiest way to measure this resistance is underneath the spring clips. That is the reason why it is advisable to measure at modules with clamps. The measuring procedure is described in the fol- lowing: Consider that the modules that are going to be proved are without voltage, i.e. the power supply of the BLUEBOX has to be switched off. Measure the resistance between CAN-High and CAN-Low as it is shown in the illustration. The measured value should be between 55 Ω and 70 Ω. At the following divergency the respec- tive errors are:. 0 Ω short circuit in line < 55 Ω more than one module terminated 120 Ω only one termination (for example, only the BlueBox is terminated) >120 Ω no module is terminated or cable break Korrekte Terminierung

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 19 / 77 www.go-sys.de [email protected] 5 Connection of the CAN-bus repeater (article no. 486 R000) The active CAN repeater is a module to enlarge the CAN-bus topology. A repeater provides eight galvanic disconnected bus segments. Each of this bus segments can connect up to five modules on a max. length of 1000 m. The individual bus segments are to be provided as necessary with a separate power supply. The connection is carried out by circuit board connectors. The transfer rate is adjusted by the factory to a value between 5 kBit/s and 50 kBit/s. In case of long cable lengths or security applications the use of an active CAN repeater is inadvisable. The figure below shows which connections of the CAN-bus inside the CAN repeater have to be terminated. The figure can only be seen as an example. T: Termination with DIP switch DIP switch at "ON"

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 20 / 77 www.go-sys.de [email protected] 6 The configuration data sheet The configuration data sheet contains the necessary settings to run the BlueBox. Example BlueBox TS:

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 21 / 77 www.go-sys.de [email protected] 1. BlueBox TS: Serial Number A1234 BlueBox Password (PIN) xxxxx Storage Device CF-256 Serial Number Serial number of the BlueBox With this serial number the BlueBox is identified by the BlueBox PC Software.  set at the factory, not changeable BlueBox Password (PIN) Password of the BlueBox Is required to change the BlueBox system settings.  set at the factory, not changeable Storage Device Model and size of the internal memory of the BlueBox, here CF-256 (CF = Compact Flash, 256 = 256 MB)  set at the factory, changeable by replacing 2. Network: IP Address 192.168.1.167 Netmask 255.255.255.0 Gateway 0.0.0.0 Port 14111 Login Name bluebox Password xxxxx IP Address IP address of the BlueBox At this address, the BlueBox is addressed on the network.  set at the factory, changeable Netmask Netmask of the BlueBox  set at the factory, changeable Gateway Default gateway of the Blue Box  set at the factory, changeable Port Network Port of the BlueBox  set at the factory1, not changeable Login Name User name for a modem connection  set at the factory, not changeable see Manual BlueBox PC Software, 3.2.3 RAS setup Password Network password of the BlueBox Is needed to access the BlueBox via the AMS software.  set at the factory, not changeable 1 14111 / or when encryption is enabled 14110

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 22 / 77 www.go-sys.de [email protected] 3. BlueGate Settings: IP Address 91.221.182.1411 Password BlueGate xxxxx IP Address IP address of an Internet Gateway  can be configured at the factory, changeable Password BlueGate Password of an Internet Gateway  can be configured at the factory, changeable2 4. BlueBox PC Software - BlueGate Settings: Host datagateway.go-sys.de Username bluebox Password Windows xxxxx If the BlueBox is accessed via a gateway (e.g. a UMTS connection), you have to enter these access data in the BlueBox SQL Software (see Manual BlueBox PC Software, 3.2.2 Setup of a new Blue- Box). only BlueBox TS 5. Spectrometer Components: Spectrometer BoardSerial Number ISA12345 ISA Sensor Head Serial Number 1234 Fibre Optic Cable Serial Number 12/3456 Zeiss Module Number 123456 ISA Spectrometer Board Serial Number Serial number of the spectrometer board  set at the factory, not changeable ISA Sensor Head Serial Number Serial number of the sensor head  set at the factory, not changeable Fibre Optic Cable Serial Number Serial number of the sensor head cable  set at the factory, not changeable Zeiss Module Number Serial number of the Zeiss spectrometer module  set at the factory, not changeable 1 IP-Address of the GO webserver (default address) 2 changeable only at the default address

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 23 / 77 www.go-sys.de [email protected] 7 Switching on the BlueBox and password input After the Blue Box has been started by switching on the power supply, shortly thereafter on the display1 ap- pear in succession the following notes. During this time the BlueBox checks the database and initiates the system. Then the BlueBox initiates the connected sensors and actuators. Once the initialization is complete, the display shows the number of connected sensors, actuators and virtual sensors2. After 20 seconds or after pressing > OK < the Parameter display (8.1) appears. 1 At delivery the touch panel is calibrated and ready for use. After a longer storage it may be necessary to adjust for the touch panel (see Appendix A). 2 The setup of virtual sensors is done with the AMS software, see manual BlueBox PC Software. GO SYSTEMELEKTRONIK Faluner Weg 1 D-24109 Kiel +049-431-58080-0 WWW.GO-SYS.DE Check Filesystem Init System Sensors 3 / 3 Aktuators 0 / 0 Virtual Sensors 1 / 1 09:19:39 10.07.10 Boot Info Search Menu Sensors 3 / 3 Aktuators 0 / 0 Virtual Sensors 1 / 1 09:19:39 10.07.10 Boot Info Ready Ok

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 24 / 77 www.go-sys.de [email protected] Password input Call-up the System menu 8.2.1 requires a password consisting of 4 digits. The password can be found in the configuration data sheet. Password **** 1 2 3 4 5 6 7 0 8 9 < <– Deletes the last entered digit. Verifies the password and switches to the System menu. If the password is incorrect, you receive an error message. < <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 25 / 77 www.go-sys.de [email protected] 8 The menu operation 8.1 Parameter display 8.1.1 Single parameter display Here, as an example, the Parameter display of an oxygen sensor with integrated temperature sensor and a ph sensor. The measured value of a sensor is displayed for 6 s, thereafter the display switches in a cycling way to the display of the next sensor. 1. Oxygen 2. Temperature 3. pH value Error messages appear instead of the parameter (see Appendix G - Status and error messages). Cycling on: In the upper right corner time and date is displayed. Cycling off: In the upper right corner time and date of the last measurement is displayed. When there is no user inactivity in all other menus for 2 minutes, the software switches back to the Parame- ter display. The bar graph on the left side of the display shows the current measured value. Menu 0 20 10 mg/l Oxygen 09:19:39 10.07.10 Menu 0 14 11 pH 09:19:39 10.07.10 pH value Menu 0 60 18°C Temperature 09:19:39 10.07.10 Switches to the Parameter display of the previous sensor. Switches the cycling of the Parameter display off. Switches to the Parameter display of the next sensor. Switches the cycling of the Parameter display off. Switches the cycling of the Parameter display on and off. The button is also a status indicator. Switches to the Main menu. Menu Setting via Display menu 8.2.1.6

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 26 / 77 www.go-sys.de [email protected] 8.1.2 Multiple parameter display Here, as an example, the Parameter display of more than 6 sensors. The measured values of a the first 6 sensors are displayed for 6 s, the order is alphabetical. Thereafter the display switches in a cycling way to the display of the next sensors. There are three ways of displaying the parameters (see display menu 8.2.1.6): • The parameters of all sensors are displayed. • Only the parameters of selected sensors and the status of selected actuators are dis- played. Selection via 8.2.3 Sensor menu and 8.2.5.1 actuator menu • The parameters of all sensors and the status of all actuators are displayed. In comparison with the single parameter display error messages are displayed shortened. When there is no user activity in all other menus for 2 minutes, the software switches back to the Parameter display. In the upper left corner you see the page number of the current display and the number of ads displayed (in this case 1/2). In the upper right corner time and date is displayed. Menu 1/2 09:19:39 10.07.10 oxygen 10 mg/l temperature outside 18 °C temperatur inside 22 °C air pessure 1006.91 hPa humidity 39.8 % pH value 11 pH Switches to the Parameter display of the previous sensor. Switches the cycling of the Parameter display off. Switches to the Parameter display of the next sensor. Switches the cycling of the Parameter display off. Switches the cycling of the Parameter display on and off. The button is also a status indicator. Switches to the Main menu. Menu Setting via Display menu 8.2.1.6

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 27 / 77 www.go-sys.de [email protected] 8.2 Main menu 09:19:39 10.07.10 <– Main menu System Sensor list Sensor User Actuator list Help Parameter display 8.1 Switches to the System menu via a password input (see 7). Switches to the menu of the Sensor list. Switches to the Sensor menu of the sensor, which is displayed in the Parameter dis- play. Switches to the menu of the User variables. Switches to the actuator list. Switches to the Help menu. Switches to the Parameter display. Menu System Sensor list Sensor User Actuator list Help <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 28 / 77 www.go-sys.de [email protected] 8.2.1 System menu 09:19:39 10.07.10 <– System menu Network Time Shutdown Modem GPS Display Language Main menu 8.2 Switches to the Network menu. Switches to the Time menu. Shuts down the BlueBox. Switches to the Modem menu. Switches to the GPS menu. Switches to the Display menu. Switches to the Language menu. Switches back to the Main menu. System Network Time Shutdown Modem GPS Display Language <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 29 / 77 www.go-sys.de [email protected] 8.2.1.1 Network Menu The network connection allows data exchange with the BlueBox and a remote control. To ensure the accuracy of the timing, you can synchronize the time setting of the BlueBox with a timeserver. 09:19:39 10.07.10 <– Network menu IP-Address Timeserver Internet Info IP-Netmask Gateway System menu 8.2.1 Switches to the input of the local IP address. Switches to the input of the local Netmask. Switches to the input of the IP address of the device, which executes the connection to other networks. Switches to the input of the IP address of a timeserver. Switches to the settings of a direct Internet connection. Switches to the Info menu. Switches back to the System menu. Network IP-Address IP-Netmask Gateway Timeserver Internet Info

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 30 / 77 www.go-sys.de [email protected] 8.2.1.1.1 IP-Address menu Network menu 8.2.1.1 Here you can change the IP address, which identifies the BlueBox on your local network. The IP address is configured at the factory (see 6 The configuration data sheet). The current value is displayed. input of the IP address with the numeric keys Network: IP Address 192.168.1.167 Netmask 255.255.255.0 Gateway 0.0.0.0 Port 14111 Login Name bluebox Password xxxxx see 6 The configuration data sheet Deletes the last entered character. Saves the IP address. Switches back to the Network menu. IP-Address IP-Address 192.168.1.169 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 31 / 77 www.go-sys.de [email protected] 8.2.1.1.2 Netmask menu Network menu 8.2.1.1 Here you can change the netmask, the netmask defines the IP address range of the network .. The netmask is configured at the factory (see 6 The configuration data sheet). The current value is displayed. input of the netmask with the numeric keys Network: see 6 The configuration data sheet Deletes the last entered character. Saves the netmask.. Switches back to the Network menu. IP-Netmask Netmask 255.255.255.0 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <– IP Address 192.168.1.167 Netmask 255.255.255.0 Gateway 0.0.0.0 Port 14111 Login Name bluebox Password xxxxx

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 32 / 77 www.go-sys.de [email protected] 8.2.1.1.3 Gateway IP-Address (default gateway) Network menu 8.2.1.1 If the BlueBox shall communicate via the LAN connection with other networks, enter the IP address of the device that executes the connection (another BlueBox, routers, servers, etc.). The current value is displayed. input of the IP address of the gateway with the numeric keys Network: IP Address 192.168.1.167 Netmask 255.255.255.0 Gateway 0.0.0.0 Port 14111 Login Name bluebox Password xxxxx see 6 The configuration settings sheet, default 0.0.0.0 Deletes the last entered character. Saves the IP address of the gateway Switches back to the Network menu. Gateway Gateway 0.0.0.0 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 33 / 77 www.go-sys.de [email protected] 8.2.1.1.4 Input timeserver Network menu 8.2.1.1 After entering an IP address or a Web address of a time server, the BlueBox automatically synchronizes your system time with the server time. The current IP address or web address is displayed. Saves the input and switches back to the Network menu settings. Timeserver Switches between the three input menu back and forth. Deletes the last entered character. Switches back to the Network menu without saving the input.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 34 / 77 www.go-sys.de [email protected] 8.2.1.1.5 Internet settings Network menu 8.2.1.1 From this menu you can determine the manner of connection of the Blue Box to a computer on the Internet and set the connection on and off. Requires an Internet connection via the network cable to the BlueBox or an Internet connection via an inter- nal or external∗ GPRS/UMTS modem (see 8.2.1.4 Modem menu). View Service enabled View Service disabled Switches to the menu of the UDP settings. UDP = User Datagram Protocol Switches to the menu of the Gateway settings of the Internet connection. Switches to the menu of the DynDNS settings of the Internet connection. Only by a connection via GPRS/UMTS modem. For service tasks GO Systemelektronik can access from the outside to the BlueBox. Service enabled: access to the operating system functions of BlueBox Service disabled: no access to operating system functions of BlueBox Default: Service enabled The button is also a status indicator. Switches back to the Network menu. ∗ External modems are not supported from GO Systemelektronik. Internet 09:19:39 10.07.10 <– Internet settings UDP settings Service enabled DynDNS settings Gateway settings 09:19:39 10.07.10 <– Internet settings UDP settings Service disabled DynDNS settings Gateway settings UDP settings Gateway settings DynDNS settings Service enabled Service disabled <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 35 / 77 www.go-sys.de [email protected] 8.2.1.1.5.1 UDP settings Menu Internet settings 8.2.1.1.5 The UDP settings are necessary for the transmission of measurement data to a PC (e.g. for the online data service BlueGate). View Encryption on View Encryption off Switches to the input of the IP address of the destination computer. Switches the AES encryption of the connection off and on. The button is also a status indicator. Default = Encryption off The button is also a status indicator. Switches to the setting of the encryption password. Only visible at . Switches back to the menu Internet settings. UDP settings 09:19:39 10.07.10 <– UDP settings IP-Address Encryption on Password 09:19:39 10.07.10 <– UDP settings IP-Address Encryption off IP-Address Encryption on Encryption off Password <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 36 / 77 www.go-sys.de [email protected] 8.2.1.1.5.1.1 Setting IP address (UDP) Menu UDP settings 8.2.1.1.5.1 Here you can enter the IP address of the destination computer in the Internet, to which the measuring data is transmitted. The UDP protocol via port 14112 is used for the transmission. The current IP address is shown. If a access to the BlueGate server was ordered, the IP address of the BlueBox is set to the default address 91.221.182.141 upon delivery. Deletes the last entered character. Saves the IP address. Switches back to the menu UDP settings. BlueGate Settings: IP Address 91.221.182.141 Password BlueGate xxxxx see 6 The configuration data sheet see also 8.2.1.1.5.2 Gateway settings (Internet) IP-Address 91.221.182.141 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 37 / 77 www.go-sys.de [email protected] 8.2.1.1.5.1.2 Determine the password of the encryption Menu UDP settings 8.2.1.1.5.1 The current setting is displayed. Saves the input and switches back to the Menu UDP settings. BlueGate Settings: IP Address 91.221.182.141 Password BlueGate xxxxx see 6 The configuration settings sheet see also 8.2.1.1.5.2 Gateway settings (Internet) Password Switches between the three input menu back and forth. Deletes the last entered character. Switches back to the Menu UDP settings without saving the input.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 38 / 77 www.go-sys.de [email protected] 8.2.1.1.5.2 Gateway settings (Internet) Menu Internet settings 8.2.1.1.5 If the BlueBox shall communicate bidirectional with a computer in the Internet, enter here the IP address of your BlueBox gateway and the associated password. IP address and password you get from GO Systemelektronik (see 6 The configuration data sheet). . Input of the IP address of the gateway. Input of the password of the gateway. Switches back to the Menu Internet settings. BlueGate Settings: IP Address 91.221.182.141 Gateway IP Password BlueGate xxxxx Gateway PW see 6 The configuration data sheet A gateway is necessary if any of those conditions is met: 1. The UMTS Internet connection has, assigned by the provider, a private IP address. - private IP address space: 10.0.0.0 – 10.255.255.255 172.16.0.0 – 172.31.255.255 192.168.0.0 – 192.168.255.255 - 2. Your provider blocks access from the Internet with a firewall. 3. More than one BlueBox is connected with the Internet via a UMTS modem. Gateway settings 09:19:39 10.07.10 <– Gateway settings Gateway IP Gateway PW Gateway IP Gateway PW <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 39 / 77 www.go-sys.de [email protected] 8.2.1.1.5.2.1 Input gateway settings (Internet) Menu Gateway settings (Internet) 8.2.1.1.5.2 Input of the IP address or web address of the gateway and input of the password of this connection. The current setting is displayed. Saves the input and switches back to the Menu Gateway settings (Internet). Gateway IP Gateway PW Switches between the three input menus back and forth. Deletes the last entered character. Switches back to the Menu Gateway settings (Internet) without saving the input.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 40 / 77 www.go-sys.de [email protected] 8.2.1.1.5.3 DynDNS settings Menu Internet settings 8.2.1.1.5 Here you can enter the DynDNS settings. For the correct entries: Contact your DynDNS provider. Currently only the DynDNS service www.dyndns.org is supported. Input Name under which the BlueBox on DynDNS can be reached Input Login Username of your DynDNS account Input Login password of your DynDNS account Switches back to the menu Internet settings. If you need no Internet gateway (see 1.1.2), you can access via a DynDNS service from the Internet on the BlueBox. Condition is: 1. Your GPRS / UMTS Internet connection has a public IP address. 2. The access is not blocked by the provider. DynDNS settings 09:19:39 10.07.10 <– DynDNS settings Host Username Password Host Username Password <– Note: In the Network settings off the BlueBox in the BlueBox Software the encryption of the con- nection must be ena- bled. There are no approved non-encrypted connec- tions over the Internet.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 41 / 77 www.go-sys.de [email protected] 8.2.1.1.5.3.1 Input DynDNS settings DynDNS settings 8.2.1.1.5.3 The current setting is displayed. Saves the input and switches back to the Menu DynDNS settings. Host Username Password Switches between the three input menu back and forth. Deletes the last entered character. Switches back to the Menu DynDNS without saving the input.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 42 / 77 www.go-sys.de [email protected] 8.2.1.1.6 Info Network Network menu 8.2.1.1 Here the current network settings are listed. Switches back to the Network menu. 8.2.1.2 Time menu Info Info IP-Address 192.168.1.60 Netmask 255.255.255.0 Gateway 0.0.0.0 Timeserver (no sync) <– <– 09:19:39 10.07.10 <– Time Date Time Time zone Time drift System menu 8.2.1 Switches to the input of the date. Switches to the input of the time. Switches to the input of the time zone. Switches to the input of the time drift. Switches back to the System menu. Time Date Time Time zone Time drift <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 43 / 77 www.go-sys.de [email protected] 8.2.1.2.1 Date menu 8.2.1.2 Time menu Selection of day setting Selection of month setting Selection of year setting selection -1 selection +1 Switches back to the Time menu. Date 10.07.10 Date <– Day Month Year - + Day Month Year <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 44 / 77 www.go-sys.de [email protected] 8.2.1.2.2 Time menu 8.2.1.2 Time menu Selection of hour setting Selection of minute setting Selection of second setting selection -1 selection +1 Switches back to the Time menu. First set the time zone before you set the time. Summer time is adjusted only by changing the time zone (e.g. from +1 to +2). Time 09:19:39 Time <– Hour Min Sec - + Hour Min Sec <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 45 / 77 www.go-sys.de [email protected] 8.2.1.2.3 Time zone menu 8.2.1.2 Time menu Please note that the setting described here only has impact on the displayed time zone and not on the data-bound time. time zone -0,25 time zone +0,25 Switches back to the Time menu. 8.2.1.2.4 Time drift menu 8.2.1.2 Time menu The time drift refers to the daily clock drift of the internal clock. Enter the value of the clock drift in seconds here and the clock drift is corrected. Deletes the last entered character. Saves the input and switches back to the Time menu. Switches back to the Time menu without saving the input. Time zone <-- - + + 2:00 h 09:19:39 10.07.10 Time zone <– Time drift Time drift per day 0.00s 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 46 / 77 www.go-sys.de [email protected] 8.2.1.3 Shutdown For a proper operation it is necessary to shut down the BlueBox before disconnecting the power supply. The state of the shutdown is displayed. The shutdown is complete. You can turn off the BlueBox by interrupting the power supply. If the BlueBox is not disconnected from the power supply after shutdown, it restarts again automatically after 10 minutes. 09:19:39 10.07.10 Shutdown? YES NO System shuts down BlueBox halt Shutdown BlueBox BlueBox is down System menu 8.2.1 Shutdown of the BlueBox Switches back to the System menu Shutdown Yes No

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 47 / 77 www.go-sys.de [email protected] 8.2.1.4 Modem menu / Modem settings The view varies depending on the selected modem type (see: 8.2.1.4.3 Modem type settings). 09:19:39 10.07.10 <– Modem menu Port PIN Modem type UMTS Info System menu 8.2.1 Switches to the Modem port setup. Switches to the input of the PIN number of the modem. Only visible if modem type or is selected in the Modem type settings (see: 8.2.1.4.3 Modem type settings). Switches to the modem type settings. Switches to the UMTS settings. Only visible if modem type is selected in the Modem type settings (see: 8.2.1.4.3 Modem type settings ). Switches to the Info menu of the modem settings. Switches back to the System menu. Modem Port PIN Modem type UMTS Info <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 48 / 77 www.go-sys.de [email protected] 8.2.1.4.1 Modem port setup Modem port setup Off Serial 1 USB 1 USB 2 <– Modem menu 8.2.1.4 Enables or disables the modem connection. If a factory-mounted modem is connected to the serial interface, then this in- terface is activated by the manufacturer. If a factory-mounted modem is connected to the USB interface, then the USB interface is activated for the modem by the manufacturer via this button. For special cases, e.g. if USB 1 is allocated to a GPS receiver. Switches back to the Modem Menu. Port Off Off Serial 1 Serial 1 USB 1 USB 1 <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 49 / 77 www.go-sys.de [email protected] 8.2.1.4.2 Input of the PIN number It is important to change the PIN number before installing or activating a new UMTS card, as otherwise the UMTS card will be disabled by standardly repeated queries. Input of the PIN number with the numeric keys Modem PIN 1 2 3 4 5 6 7 0 8 9 < <– Ok Modem menu 8.2.1.4 Deletes the last entered character. Saves the input and switches back to the Modem Menu. Switches back to the Modem Menu without saving the input. PIN < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 50 / 77 www.go-sys.de [email protected] 8.2.1.4.3 Modem type settings From this menu, the type of a connected modem is set. ∗ optional extra equipment Modem type Off GSM GPRS/UMTS ISDN Analog <– Modem menu 8.2.1.4 No modem is connected. A GSM modem∗ is connected. An ISDN modem is connected. An Analogue modem is connected. A GPRS modem* or a UMTS modem is connected. Saves the input and switches back to the Modem Menu. Modem type Off Off GSM GSM ISDN ISDN Analog Analog GPRS/UMTS GPRS/UMTS <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 51 / 77 www.go-sys.de [email protected] 8.2.1.4.4 UMTS settings From this menu, you set up your UMTS connection. For APN, username and password, contact your UMTS provider. The routing must be switched on, if you use this BlueBox as an Internet router. This is for example the case, when via this BlueBox other BlueBoxes send measured values. Please note that the connected BlueBoxes must use the IP address of the routing BlueBox as the address of the default gateway see (8.2.1.1.3). <– UMTS settings APN Username Password Routing disabled Modem menu 8.2.1.4 Input APN (Access Point Name) Input Username (Login name) Input Password (Login password) Switches the routing on and off. The button is also a status indicator. Factory default: routing off Switches back to the Modem Menu. UMTS APN Username Password Routing enabled Routing disabled <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 52 / 77 www.go-sys.de [email protected] 8.2.1.4.4.1 Input UMTS settings UMTS settings 8.2.1.4.4 The current setting is displayed. Saves the input and switches back to the Menu UMTS settings. 8.2.1.4.5 Modem Info (UMTS) Display of the actual settings of the UMTS modem RX bytes: received data since connection started TX bytes: transfered data since connection started APN Username Password <– Modem Info APN : nn Username : nn Password : nn IP-Address : nn RX bytes : nn TX bytes : nn Switches between the three in- put menu back and forth. Deletes the last entered character. Switches back to the Menu UMTS settings without saving the input. Modem menu 8.2.1.4 Info

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 53 / 77 www.go-sys.de [email protected] 8.2.1.5 GPS Menu 8.2.1.5.1 GPS Port Setup 09:19:39 10.07.10 <– GPS Menu Port Info <– GPS Port Setup Off Serial 1 USB 1 USB 2 09:19:39 10.07.10 System menu 8.2.1 Switches to the settings of the connection of a GPS receiver. Switches to the information menu of the GPS connection, here are the relevant GPS data listed. Switches back to the System menu GPS menu 8.2.1.5 Enables or disables the GPS connection. If a factory-mounted GPS receiver is connected to the serial interface, then this inter- face is activated by the manufacturer. If a factory-mounted GPS receiver is connected to the USB interface and USB 1 is not allocated to a modem, then the USB interface is activated for the GPS receiver by the manufacturer via this button. If a factory-mounted GPS receiver is connected to the USB interface and USB 1 is allocated to a modem, then the USB interface is activated for the GPS receiver by the manufacturer via this button. Switches back to the GPS menu. GPS Port Info <– Port Off Off Serial 1 Serial 1 USB 1 USB 1 USB 2 USB 2 <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 54 / 77 www.go-sys.de [email protected] 8.2.1.6 Display Press a point on the bar for Light or Dark to set the value of the backlight of the display. When there is no user activity, after 150 seconds the software turns the backlight of the display to the value of Light to the value of Dark. If there is user activity it switches back. At an elevated temperature of the CPU the Dark value is ignored and the backlight of the display is switched off. 09:19:39 10.07.10 <– Display Light Dark Display 1 sensor Selected sensors System menu 8.2.1 Switches the parameter display between the single mode and the multiple mode back and forth (see 8.1 Parameter display). The button is also a status indicator. Defines with sensors/actuators will be displayed in the multiple parameter display (see 8.1.2 Multiple parameter display). The button is also a status indicator. There are three posibilities: • Only the parameters of selected sensors and the status of selected actuators are displayed. Selection via 8.2.3 Sensor menu and 8.2.5.1 actuator menu • The parameters of all sensors and the status of all actuators are displayed. • The parameters of all sensors are displayed. Switches back to the system menu. Display Display 6 sensors Display 1 sensor Sensors & actuators Selected sensors Only sensors <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 55 / 77 www.go-sys.de [email protected] 8.2.1.7 Language settings <– Language settings Deutsch Español Française English System menu 8.2.1 Selection menu language German, the button is also a status indicator. Selection menu language English, the button is also a status indicator. Selection menu language Spanish, the button is also a status indicator. Selection menu language French, the button is also a status indicator. Switches back to the system menu. Language Deutsch English Español Française <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 56 / 77 www.go-sys.de [email protected] 8.2.2 Sensor list Use this menu to access the menu of the connected sensors. The buttons of the sensors are arranged alphabetically. If necessary you can change a sensor name with the AMS software. In the example chosen here is the 1st Sensor, an oxygen sensor. 2nd Sensor, a pH sensor. 3rd Sensor, a temperature sensor. <– Oxygen pH value Temperature 1/1 Main menu 8.2 Switches to the menu of the oxygen sensor. Switches to the menu of the pH sensor. Switches to the menu of the temperature sensor. Scrolls the list. Switches back to the Main menu. Sensor list Oxygen pH value Temperature <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 57 / 77 www.go-sys.de [email protected] 8.2.3 Sensor menu Example oxygen From this menu you can determine the settings of a connected sensor and calibrate it (if necessary), repre- sent their values over time and see the current settings of the sensor. For the specific settings of the con- nected sensor, please refer to the description of the sensors. 09:19:39 10.07.10 <– Oxygen Interval Average Calibration Table Diagram Info Selected 09:19:39 10.07.10 <– pH value Interval Average Calibration Table Diagram Info Selected Cal. mode Main menu 8.2 Switches to the Sensor menu of the sensor, which is displayed in the Parameter display. Sensor list 8.2.2 Switches to the input of the measurement interval. Switches to the input of the measurement average. Switches to the calibration menus. Switches to the table display. Switches to the diagram display. Switches to the sensor information. Selects the sensor for the multiple parameter display or not. see also 8.2.1.6 Display Switches to the menu for the selection of the calibration mode. Only visible with sensors, in which a selection of calibration mode is possible. Switches back to the sensor menu. Sensor Oxygen Interval Average Calibration Table Diagram Info Selected Selected Cal. mode <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 58 / 77 www.go-sys.de [email protected] 8.2.3.1 Interval and Average Interval: Period in seconds between the end of a measurement and the end of the next measurement. Choose the interval according to the characteristics of the sensor. Each sensor requires a certain minimum period for measuring a value. Please note the data sheet of the sensor. The higher the interval is set, the fewer measurements are taken, the shorter the download time. Averaging: The measured value is the arithmetic average of the selected number of single measurements. Current settings are displayed as "Actual value". Interval Aktual value 60 1 2 3 4 5 6 7 0 8 9 < <– Ok Average Aktual value 6 1 2 3 4 5 6 7 0 8 9 < <– Ok measurement cycle interval new measurement measuring time single measurements (here 5) Sensor menu 8.2.3 Deletes the last entered character. Saves the input and switches back to the Sensor menu. Switches back to the Sensor menu without saving the input. Interval Average < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 59 / 77 www.go-sys.de [email protected] 8.2.3.2 Calibration The BlueBox allows calibration of sensors in the connected state. Calibration is password protected, see: 7 Switching on the BlueBox and password input. A detailed description of the calibration can be found at: Appendix B / Calibrating a pH sensor Appendix C / Calibration of an oxygen sensor 09:19:39 10.07.10 <– Set Oxygen Ox yge n c a li brati o n 0.0 mg/l Sensor menu 8.2.3 Switches to the input of the first measuring point. Switches back to the sensor menu. Calibration Set <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 60 / 77 www.go-sys.de [email protected] 8.2.3.3 Table display (sensor values) Sensor menu 8.2.3 Scrolls the list. Displays the measurement values of the previous day. Displays the measurement values of the nest day. Switches to the sensor menu. Table Table Statistics List Statistics min. max. mittl. 1h 8.4 10.6 9.4 6h 8.3 9.7 9.2 12h 9.1 11.7 10.0 24h 8.8 10.9 9.4 7d 8.7 11.1 10.8 Oxygen [mg/l] <– List <– < > 10.07.10 08:56:38 8.8 08:57:38 8.8 08:58:38 9.0 08:59:38 8.9 09:00:38 9.1 09:01:38 9.2 09:02:38 9.2 Oxygen [mg/l] < > <– Statistics of the measurement values over the past 24 hours and the last 7 days. List of the measurement values of one day.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 61 / 77 www.go-sys.de [email protected] 8.2.3.4 Diagram display (sensor values) Sensor menu 8.2.3 Diagram Diagram Auto scale Range Auto scale Oxygen last 24h 13 16 19 22 01 04 07 10 13 12 11 10 9 8 7 6 5 4 3 2 Range 13 16 19 22 01 04 07 10 13 Oxygen last 24h 20 18 16 14 12 10 8 6 4 2 0 Measurement values over the past 21 - 24 hours (depending on the range of values), scaled to min/max of all measured values. Pushing on the display switches to the sensor menu. Measurement values over the past 21 - 24 hours (depending on the range of values). Pushing on the display switches to the sensor menu.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 62 / 77 www.go-sys.de [email protected] 8.2.3.5 Sensor info Sensor menu 8.2.3 Commnent general comment for the sensor Sensor serial no DAM-ID (8-digit designation of the Data Acquisition Module) + run number of the sensor (0-9) Interval measurement interval of the sensor Average measurement average Resolution measurement resolution Parameter name of the parameter Unit unit of the parameter Last update date of the last measurement Switches back to the sensor menu. Info Oxygen Comment Sensor serial no. tox000032 Interval 60 Average 6 Resolution 0.1 Parameter Oxygen Unit mg/l Last update 01:33:01 03.04.10 <– <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 63 / 77 www.go-sys.de [email protected] 8.2.3.6 Selection calibration mode Here you can set the calibration mode of a sensor. GO Systemelektronik recommends using the default setting. The values of the data points are the running average from the last 15 seconds∗. A detailed description of the calibration can be found in: Appendix B - Calibration of a pH sensor Appendix C - Calibration of an oxygen sensor The calibration of the two optional current outputs only happens with the AMS software. ∗ Strictly speaking, these are the last 15 measurement values, but since all connected sensors (in fact all but the ISA spectrometer) are automatically set to a measurement interval of one second during calibration, it's the running av- erage of the last 15 seconds. <– One point calibration y0=0 One point calibration y0=fix Two point calibration Sensor menu 8.2.3 Calibration mode one point calibration with with a calibration curve through the origin. The button is also a status indicator. Calibration mode one point calibration with with a calibration curve thats y0-value is set by the calibration factors of the sensor. The button is also a status indicator. Calibration mode two point calibration The button is also a status indicator. Switches back to the sensor menu. Cal. mode One point calibration y0=0 One point calibration y0=fix Two point calibration <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 64 / 77 www.go-sys.de [email protected] 8.2.4 User variables Main menu 8.2 Example with two user variables The AMS program as part of the BlueBox PC Software allows users to define variables that can be changed directly in the BlueBox. Switches to the menu of the first variable. Switches to the menu of the second variable. Switches back to the Main menu. menu of the first variable The current value of the user variable is shown. Switches to the input menu of the first variable. Switches back to the menu of the user variable. input menu of the user variable Here you can change the value of the user variable. Deletes the last entered character. Saves the input and switches back to the menu of the user variable. switches back to the menu of the user variable without saving the input. User <– Variable1 Variable2 1/1 Variable1 Variable2 <– 09:19:39 10.07.10 <– Setzen Variable1 2. 5 Setzen <– Variable1 1 2 3 4 5 6 7 0 8 9 . < <– Ok < Ok <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 65 / 77 www.go-sys.de [email protected] 8.2.5 Actuator list Main menu 8.2 Use this menu to access the menu of the connected actuators. The buttons of the actuators are arranged alphabetically. If necessary you can change a sensor name with the AMS software. In the example chosen here there are two relays. Switches to the menu of the first actuator. Switches to the menu of the second actuator. Scrolls the list. Switches back to the Main menu. Actuator list <– Relay 1 Relay 2 1/1 Relay 1 Relay 2

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 66 / 77 www.go-sys.de [email protected] 8.2.5.1 Actuator menu Example Relais 1 Actuator list 8.2.5 From this menu you can turn on and off a connected actuator and represent his values over time and see the current settings of the actuator. For the specific settings of the connected actuator, please refer to the de- scription of the actuator. Switches to the set menu of the actuator. Switches to the diagram display of the actuator behaviour. Switches to the info menu of the actuator. Selects the actuator for the multiple parameter display or not. see also 8.2.1.6 Display Switches back to the main menu. Relay 1 09:19:39 10.07.10 <– Relay 1 Set Diagram Info Selected Set Diagram Info Selected Selected <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 67 / 77 www.go-sys.de [email protected] 8.2.5.1.1 Actuator setting Example Relais 1 Actuator menu 8.2.5.1 From this menu you can determine the status of a connected actuator, in this example you can turn a relay on and off. For the specific settings of the connected actuator, please refer to the description of the actuator. Switches the relay on, the button is also a status indicator. Switches the relay off, the button is also a status indicator. Switches back to the Actuator menu. Set 09:19:39 10.07.10 Relay 1 ON OFF <– ON OFF <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 68 / 77 www.go-sys.de [email protected] 8.2.5.2 Diagram display (actuator) Actuator menu 8.2.5.1 Displays the status of an actuator over the last 21 to 24 hours (similar 8.2.3.4 Diagram display (sensor val- ues)). 8.2.5.3 Actuator info Actuator menu 8.2.5.1 Comment general comment for the actuator Sensor serial no. i.e. actuator number Interval Inspection interval for the query function of the actuator Average 1 - default value for actuators Resolution 1 - default value for actuators Parameter switch - default value for relays Unit not used Last update The update function is used for a function query and happens after each inspection interval. Switches back to the Actuator menu. Diagram Diagram Auto scale Range Info Relay 1 Comment Pumpe 1 Sensor serial no. fst002788 Interval 300 Average 1 Resolution 1 Parameter switch Unit Last update 01:33:01 03.04.10 <– <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 69 / 77 www.go-sys.de [email protected] 8.2.6 Help menu 8.2.6.1 Info menu of the system <– Info SYSTEMELEKTRONIK Tel : +49-431-58080-0 Fax : +49-431-58080-11 Sensors = 3 / 3 Actuators = 0 / 0 Virtual Sensors = 1 / 1 Software Version = 2.69.82 UPS = N/V 09:19:39 10.07.10 System Info <– Main menu 8.2 Switches to the info menu of the system. Switches to the menus of the plug and clip connection. Switches back to the Main menu. Help menu 8.2.6 Switches back to the Help menu. Help Info <– Info <–

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 70 / 77 www.go-sys.de [email protected] 8.2.6.2 Plug and clip connection GO Systemelektronik GmbH p l u g m a l e [ 3 3 8 1 1 0 0 ] 1 g r e e n C A N - H 2 y e l l o w C A N - L 3 w h i t e + 2 4 4 b r o w n G N D 2 4 V p l u g f e m a l e [ 3 3 8 1 0 0 0 ] 3 w h i t e + 2 4 4 b r o w n G N D 2 4 V M12 Plug 4 <– 2 4 1 3 3 4 4 Connector <– 1 4 [ 3 3 8 0 1 3 0 ] 1 g r e e n C A N - H 2 y e l l o w C A N - L 3 w h i t e + 2 4 V 4 b r o w n G N D 2 4 V Help menu 8.2.6 Switches back. Switches forward. Switches to the Main menu. <– Shows the pin assignments at the BlueBox for the current version. plug male: M12-pin connector on the CAN-bus cable 338 1100 is the article number of the M12 pin connector. plug female: M12 female connector on the power supply cable 338 1000 is the article number of the M12 socket plug. Color coding is for the GO standard cable. Shows the terminal connections of the CAN-bus cable into the sensor modules for socket connectors with 4 contacts. 338 0130 is the article number of the 4-terminal socket con- nector. Color coding is for the GO standard cable.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 71 / 77 www.go-sys.de [email protected] Appendix A - Adjustment of the touch display If the display responses not or wrong to a button, a display adjustment is necessary. While switching on power, press display until the notice "touch adjustment ? don't touch for normal use" appears. Left off the display immediately! Press the display immediately again for more than one second. A blinking dot appears at top left. Press the blinking dot top left. A blinking dot appears at bottom right. Press the blinking dot bottom right. The adjustment is finished.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 72 / 77 www.go-sys.de [email protected] Appendix B - Calibrating a pH sensor The pH sensor is an electrochemical sensor. To function properly, electrochemical sensors have to recalibrate in regular intervals. This is best done weekly, but at least a monthy. For the two-point calibration you need two calibration fluids with different pH values, eg pH 4 and pH 9.2. In this two-point calibration it is always the lower value first and then the higher value is measured. The Bluebox independently calculates the calibration curve. The calibration fluids are available as accessories under the item no. 3615910 at GO-Systemelektronik. In addition, you need clean water for rinsing of the probes between the calibration steps. Press the Main Menu on , then on the desired sensor and then . To protect against misuse there is a password protection set up. The four-digit code number is in the information sheet. Continue with Before the calibration starts, it is neccesary to rinse the selected pH sensor with clean tap water. This prevents pollution of the calibration fluid. Open the bottle with the calibration fluid pH4. The with clean tap water rinsed pH sensor can be gently screwed into the interior of the bottle with the calibration fluid. Now turn around the pH sensor together with the bottle, so that the sensor end is lapped with calibration fluid. Leave the sensor in the calibration fluid until the display is stable Below the measured value the <[raw value]> is shown.Pressing leads to the input of the first measuring point. Enter the pH value of the calibration fluid (here pH 4). Continue with The process is repeated with the second calibration fluid. Continue with Calibration set pH sensor in tap water 1 2 3 4 5 6 7 8 9 0 . < Ok <-- 1 2 3 4 5 6 7 8 9 0 . < Ok <-- 09:19:39 09.07.08 <-- Setzen pH 1. Messwert 7.2 pH [2798] 09:19:39 09.07.08 <-- Setzen pH 2. Messwert 9.0 pH [2522] pH pH pH 1 2 3 4 5 6 7 8 9 0 . < Ok <-- pH 1 2 3 4 5 6 7 8 9 0 . < Ok <-- 09:19:39 09.07.08 <-- Set pH 1.Value 7.2 pH [2798] 09:19:39 09.07.08 <-- Set pH 2. Value 9.0 pH [2522] The calibration is completed.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 73 / 77 www.go-sys.de [email protected] Appendix C - Calibration of an oxygen sensor The oxygen sensor is an electrochemical sensor. To function properly, electrochemical sensors have to be recalibrated at regular intervals. This is best done weekly, but at least monthly. There are two types of calibration: • Calibration with a reference fluid and • Calibration in the air. Press in the measurement display on and on the main menu, then on the desired sensor and then on . To protect against misuse there is a password protection set up. The four-digit code number is in the information sheet. Continue with Calibration with a reference fluid Immerse the oxygen sensor in the reference fluid and wait until the displayed value is stable. Calibration in air Hold the oxygen sensor approximately 15 minutes to the air. Continue with Enter the oxygen content of the reference fluid. Continue with Check whether the measured value agrees with the reference value. Continue with Continue with Enter -1 Continue with The calibration is completed. After 2 seconds the BlueBox switches to the measurand repre- sentation.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 74 / 77 www.go-sys.de [email protected] Appendix D - Example configuration BlueGate-Server BlueBox settings: see also 8.2.1.1.5.1 UDP settings Menu Internet settings 8.2.1.1.5 The current value is displayed. see 6 The configuration data sheet: BlueGate settings: IP Address 91.221.182.141 Password BlueGate xxxxx Router settings: For transmission of measurement data to the BlueGate Server the following port must be configured: • Port 14112 UDP -> 91.221.182.141 For bidirectional communication with the BlueBox the following port must be configured: • Port 14003 TCP <-> 91.221.182.141 For Windows-Software communication the following port must be configured: • Port 14002 TCP <-> datagateway.go-sys.de If a time server is connected to the BlueBox the following configuration is necessary: • Port 37 TCP/UDP <-> Timeserver IP. Note: If the internal network is not a Class A, B or C network then communication with the BlueBox is only possible over: • Port 14110/TCP (SSL encrypted) Unencrypted communication with the BlueBox is only possible from the following networks: • 10.0.0.0/8 Class A network • 172.16.0.0/12 Class B network • 192.168.0.0/16 Class C network UDP settings 09:19:39 10.07.10 <– UDP settings IP-Address Encryption on Password 91.221.182.141 1 2 3 4 5 6 7 0 8 9 . < <– Ok 1 2 1 2

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 75 / 77 www.go-sys.de [email protected] Appendix E - Update of the BlueBox firmware Precondition is an operating LAN connection of the BlueBox. Start FirmwareUpdate.exe on your PC. Click • Select the tab . • Enter the network password of the BlueBox. (see 6 „The configuration data sheet“ item Network) • enter the IP-Address of the BlueBox. (see 6 „The configuration data sheet“ item Network) Click Click . The BlueBox reboots, you can close the window. Wait until the BlueBox is ready. The update is completed successfully. Click Firmware version of the update

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 76 / 77 www.go-sys.de [email protected] Appendix F - Opening a BlueBox housing Shut down the BlueBox. Disconnect the BlueBox from the power supply. 1. Remove the covers on both sides of the BlueBox. 2. Unscrew the four fixing screws. 3. Open the housing by hinging the cover from the front to the back. In the cover there is the mainboard. This work must be carried out by qualified persons using suitable tools.

GO Systemelektronik GmbH

Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 77 / 77 www.go-sys.de [email protected] Appendix G - Status and error messages Display Description Parameter The sensor sends data. No data The sensor sends no data. Wait The BlueBox is waiting for the first measured value. [Parameter] Sensor warning, the measured value may be faulty. Calc error AMS formula error ? Sensor In an AMS formula an unknown sensor is used. Calc run The computing time in an AMS formula has been exceeded (for or while loop). max Parameter The maximum measured value as determined in AMS was exceeded. Com error Communication error with the sensor ADC min The lower limit of the AD converter was underrunned. ADC max The upper limit of the AD converter was exceeded. Dev error Device error At the multiple parameter display (see 8.1.2) error messages appear shortened. 11614