Key Pages of Document

• The straps for mounting on a pole are not included, the width should not exceed 14mm.

• The screws for mounting on a wall are not included, the diameter of the screws must be 6mm. • The covers have to be screwed at their maximum to ensure waterthightness (USIM and LED/buttons) © Copyright photo - Kerlink - all right reserved 5 Markings Symbol Description Symbol Description Wirnet iStation Type of Equipment QR code www.ime.de ime mobile solutions GmbH • Borsigstraße 7-9 • D-93092 Barbing • +49 9401 9333-0 • [email protected] • www.ime.de 04-12-19 ...

Declaration of Conformity

7.1 Wirnet™ iStation 868 Simplified EU Declaration of Conformity Hereby, Kerlink, declares that the radio equipment type Wirnet™ iStation 868 is in compliance with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.kerlink.com/support In Europe, the Wirnet™ iStation 868 station must comply with the ERC 70-03 requirements regarding duty cycle and maximum EIRP. They are summarized in the following table ERC 70-03 Frequency (MHz) Power Duty Cycle h5 865-868 14dBm ERP 1% h6 868-868,6 14dBm ER ...

1. Need help?

• In order to provide the most updated technical documentation, as well as considering and saving the environmental resources, Kerlink is providing preferably “Online documentation”. • Kerlink is gathering all the technical information on a Wiki: http://wikikerlink.fr/ - If your don’t have yet your Wiki login/password please request them to [email protected] (note that the“Product ID” of one of your products will be required). - How to find the “Product ID”? Please look at the Wirnet iStation sticker placed on the right side of the case. • On the Wiki, Kerli ...

6.2 Setting connections

Before setting all connections, ensure that the power supply is not connected to the mains supply. GNSS, 3G/4G and LoRa antenna are integrated. An external optionnal LoRa antenna can be added by opening the n°3 (please refer on the chart page 3) button and then screw the antenna directly or via a cable. Once the Wirnet™ iStation is installed, you can select up to 2 technologies to set up the access to Internet for the data backhaul: • Ethernet connection, requiring an Ethernet access through a dedicated RJ45 cable (not included) • 3G/4G cellular connection, requi ...

Application Notes: (from end of November 2019) for questions related to generic engineering rules

 AN-KLK03355 - Improving radio coexistence performance of LoRaWAN gateways  AN-KLK03356 - LoRaWAN gateways coverage optimization  AN-KLK03357 - LoRaWAN gateways installation recommendations  AN-KLK03358 - LoRaWAN gateways lightning protection • For any Warranty or Maintenance related request (Trouble shooting, help …),  If purchased from a Distributor, please contact the distributor directly for Level1 support  If purchased from Kerlink directly, please open an “Assista ...

6.2 Setting connections

Before setting all connections, ensure that the power supply is not connected to the mains supply. GNSS, 3G/4G and LoRa antenna are integrated. An external optionnal LoRa antenna can be added by opening the n°3 (please refer on the chart page 3) button and then screw the antenna directly or via a cable. Once the Wirnet™ iStation is installed, you can select up to 2 technologies to set up the access to Internet for the data backhaul: • Ethernet connection, requiring an Ethernet access through a dedicated RJ45 cable (not included) • 3G/4G cellular connection, requi ...

Declaration of Conformity

7.1 Wirnet™ iStation 868 Simplified EU Declaration of Conformity Hereby, Kerlink, declares that the radio equipment type Wirnet™ iStation 868 is in compliance with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.kerlink.com/support In Europe, the Wirnet™ iStation 868 station must comply with the ERC 70-03 requirements regarding duty cycle and maximum EIRP. They are summarized in the following table ERC 70-03 Frequency (MHz) Power Duty Cycle h5 865-868 14dBm ERP 1% h6 868-868,6 14dBm ER ...

IME Kerlink Wirnet iStation Series user guide recommended for: KTA-282, 460BMSC-NNA4, VoxiPlus, OfficeServ 7100, RAD IPmux-14 TDMoIP.

⚠️ Download Safety

The Gateway Quick start manual (11 pages) is completely safe to download (last scan date: 30/04/2026).

Related PDF Instructions for IME Kerlink Wirnet iStation Series:

Gateway Equipment: Frequently Requested

Have some Questions about IME Kerlink Wirnet iStation Series Device?

Get valuable and actionable advices from other IME Kerlink Wirnet iStation Series device users. Describe your problem or question, regarding the using of Kerlink Wirnet iStation Series, in as much detail as possible, and other users will be able to answer you.