Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Table of Contents i Table of Contents Chapter 1 System Maintenance and Debugging Commands ................................................... 1-1 1.1 Basic System Configuration and Management Commands.............................................. 1-1 1.1.1 clock datetime ......................................................................................................... 1-1 1.1.2 clock summer-time .................................................................................................. 1-1 1.1.3 clock timezone......................................................................................................... 1-3 1.1.4 quick-ping enable .................................................................................................... 1-3 1.1.5 sysname.................................................................................................................. 1-4 1.2 Querying System Status and Configuring Agent Information............................................ 1-5 1.2.1 display clock............................................................................................................ 1-5 1.2.2 display debugging ................................................................................................... 1-6 1.2.3 display device manuinfo.......................................................................................... 1-6 1.2.4 display fiber-module ................................................................................................ 1-7 1.2.5 display users ........................................................................................................... 1-9 1.2.6 display version....................................................................................................... 1-10 1.3 System Debugging Commands....................................................................................... 1-11 1.3.1 debugging.............................................................................................................. 1-11 1.3.2 display diagnostic-information............................................................................... 1-12 1.4 Network Connection Test Commands............................................................................. 1-14 1.4.1 ping........................................................................................................................ 1-14 1.4.2 pingmac................................................................................................................. 1-16 1.4.3 tracert .................................................................................................................... 1-17 1.4.4 tracemac enable.................................................................................................... 1-19 1.4.5 tracemac................................................................................................................ 1-20 1.5 Command Line Parser Cache Function Commands....................................................... 1-21 1.5.1 parser cache.......................................................................................................... 1-21 1.5.2 display parser statistic........................................................................................... 1-21

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-1 Chapter 1 System Maintenance and Debugging Commands 1.1 Basic System Configuration and Management Commands 1.1.1 clock datetime Syntax clock datetime HH:MM:SS YYYY/MM/DD View User view Parameters HH:MM:SS: Current time. HH ranges from 0 to 23. MM and SS range from 0 to 59. YYYY/MM/DD: Year, month and date. YYYY ranges from 2000 to 2100. MM ranges from 1 to 12 and DD ranges from 1 to 31. Description Use the clock datetime command to configure the current date and clock of the switch. By default, the date and clock of the switch is set to 0:0:0, 2000/1/1. The current date and clock of the switch must be set by this command where absolute time is strictly required. Related commands: display clock. Examples # Set the current date of the switch to 0:0:0, 2001/01/01. clock datetime 0:0:0 2001/01/01 1.1.2 clock summer-time Syntax clock summer-time zone-name { one-off | repeating } start-time start-date end-time end-date offset-time undo clock summer-time

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-2 View User view Parameters zone-name: Name of the summer time, which is a string of 1 to 32 characters. one-off: Sets the summer time of a certain year. repeating: Sets the summer time of every year starting from a certain year. start-time: Sets start time of the summer time, in the form of HH:MM:SS (hour/minute/second). start-date: Sets start date of the summer time, in the form of YYYY/MM/DD (year/month/day). end-time: Sets end time of the summer time, in the form of HH:MM:SS (hour/minute/second). end-date: Sets end date of the summer time, in the form of YYYY/MM/DD (year/month/day). offset-time: Sets the offset relative to the summer time, in the form of HH:MM:SS (hour/minute/second). Description Use the clock summer-time command to set the name, start and end time of the summer time. Use the undo clock summer-time command to restore the local time to the default UTC time. After the configuration takes effect, the display clock command can be used to check it. Besides, the time of the log or debugging information uses the local time after the adjustment of the time zone and summer time. Related commands: clock timezone. Examples # Set the summer time for z2 that starts at 06:00:00 on 08/06/2002 and ends at 06:00:00 on 01/09/2002 with the time adding 1 hour. clock summer-time z2 one-off 06:00:00 2002/06/08 06:00:00 2002/09/01 01:00:00 # Set the summer time for z2 that starts at 06:00:00 on 08/06 and ends at 06:00:00 on 01/09 in each year from 2002 on with the time adding 1 hour. clock summer-time z2 repeating 06:00:00 2002/06/08 06:00:00 2002/09/01 01:00:00

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-3 1.1.3 clock timezone Syntax clock timezone zone-name { add | minus } HH:MM:SS undo clock timezone View User view Parameters zone-name: Name of the time zone, which is a character with the length ranging from 1 to 32. add: Time is adding compared with the UTC. minus: Time is minus compared with the UTC. HH:MM:SS: Time (hour/minute/second). Description Use the clock timezone command to set the information of the local time zone. Use the undo clock timezone command to restore to the default Universal Time Coordinated (UTC) time zone. After the configuration takes effect, the display clock command can be used to check it. Besides, the time of the log or debug information uses the local time after the adjustment of the time zone and summer time. Related commands: clock summer-time. Examples # Set the name of the local time zone to Z5 with five hours ahead compared with the UTC time. clock timezone z5 add 05:00:00 1.1.4 quick-ping enable Syntax quick-ping enable undo quick-ping enable View System view

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-4 Parameters None Description Use the quick-ping enable command to enable the PING distribution function. Use the undo quick-ping enable command to disable the PING distribution function. By default, the PING distribution function is enabled. Examples # Enable the ping distribution function. system-view System View: return to User View with Ctrl+Z. [H3C] quick-ping enable 1.1.5 sysname Syntax sysname sys-name undo sysname View System view Parameters sys-name: Hostname of the switch, a string of 1 to 30 characters. The default hostname of the switch is H3C. Description Use the sysname command to configure the system name of the switch. Changing the hostname name of the switch will affect the prompt of command line interface. For example, if the system name of the switch is H3C, and the prompt in user view is . Use the undo sysname command to restore the system name of the switch to the default value. Examples # Set the system name of the switch to H3CLANSwitch. system-view System View: return to User View with Ctrl+Z. [H3C] sysname H3CLANSwitch

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-5 [H3CLANSwitch] 1.2 Querying System Status and Configuring Agent Information 1.2.1 display clock Syntax display clock View Any view Parameters None Description Use the display clock command to display the system date and time information, so that you make timely changes if the system time is incorrect. The maximum time value supported by this command is 23:59:59 2100/12/31. Related commands: clock datetime. Examples # View the current system date and time. display clock 18:36:31 beijing Sat 2006/02/02 Time Zone : beijing add 01:00:00 Summer-Time : bj one-off 01:00:00 2003/01/01 01:00:00 2003/08/08 01:00:00 Table 1-1 display clock command output description Field Description 18:36:31 beijing Sat 2002/02/02 Current system time Time Zone : beijing add 01:00:00 Configured time zone information Summer-Time : bj one-off 01:00:00 2003/01/01 01:00:00 2003/08/08 01:00:00 Configured summer time information

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-6 1.2.2 display debugging Syntax display debugging [ interface interface-type interface-number ] [ module-name ] View Any view Parameters interface-type: Interface type supported by the switch, including Ethernet, GigabitEthernet, AUX, and VLAN-interface. interface-number: Interface number. module-name: Module name. Description Use the display debugging command to display debugging that has been enabled. You can execute the display debugging to view the specific debugging that has been enabled. If the command is executed without any parameter specified, the system will display all debugging that has been enabled. Related commands: debugging. Examples # Display all debugging that has been enabled. display debugging Multicast packet forwarding debugging switch is on 1.2.3 display device manuinfo Syntax display device manuinfo [ slot slot-number ] View Any view Parameters slot-number: Number of the slot where a card is located. Description Use the display device manuinfo command to display the manufacturing information of a card. If no slot number is specified, the command displays the manufacturing information of all cards.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-7 Examples # Display the manufacturing information of all cards. display device manuinfo slot 0 DEVICE_NAME : LSBM1GP12B DEVICE_SERIAL_NUMBER : NONE MAC_ADDRESS : NONE MANUFACTURING_DATE : 2007-07-05 VENDOR_NAME : H3C slot 5 DEVICE_NAME : H3C DEVICE_SERIAL_NUMBER : NONE MAC_ADDRESS : 00E0-FC00-5600 MANUFACTURING_DATE : 2005-11-20 VENDOR_NAME : H3C Table 1-2 display device manuinfo command output description Field Description DEVICE_NAME Device name DEVICE_SERIAL_NUMBER Serial number of an OEM device MAC_ADDRESS Start MAC address of the device MANUFACTURING_DATE Manufacturing date of the device VENDOR_NAME Vendor name 1.2.4 display fiber-module Syntax display fiber-module [ interface-type interface-number ] View Any view Parameters interface-type: Interface type supported by switch, including Ethernet and GigabitEthernet. interface-number: Interface number.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-8 Description Use the display fiber-module command to display the information of the optical modules connected with all the optical interfaces in position on the current shelf, including module information, optical module type, connector type, vendor name, manufacturer part number, single mode or multi-mode, wave length, and transmission distance. Use the display fiber-module [ interface-type interface-number | interface-name ] command to display optical module information of the specified port. � Note: If the command level that a login user can access is the visit level, the user cannot use this command. For related information, refer to the user privilege level command. Examples # Display the optical module information of all optical interfaces in position on the current shelf. display fiber-module GigabitEthernet4/1/1: Card info: 10G-XFP Fiber connect: LC VendorName: JDS Uniphase PartNumber: 64P0215 SerialNumber: W44060540031 Mode: SingleMode WaveLength: 1310nm Length for 9um: 10km Digital diagnostic monitoring: supported TX power: -1.5329 dbm, Alarm: none RX power: -27.9578 dbm, Alarm: none Table 1-3 display fiber-module command output description Field Description Card info Card information Fiber connect Fiber connector type VendorName Vendor name PartNumber Manufacturer part number Mode Single mode or multi-mode

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-9 Field Description WaveLength Wave length Length for X um: Y km/m The transmission distance of X-um sized fiber is Y km/m Length for A / B um: Y km/m The transmission distance of the fiber with an inner diameter of A um and outer diameter of B um is Y km/m. Digital diagnostic monitoring: supported The current XFP optical module supports digital diagnostic monitoring TX power: -1.5329 dbm, Alarm: none TX power: Transmit power, in dbm; Alarm: Alarm information none: No alarm. RX power: -27.9578 dbm, Alarm: none RX power: Receive power, in dbm; Alarm: Alarm information none: No alarm. 1.2.5 display users Syntax display users [ all ] View Any view Parameters all: Displays all users connected to the switch. Description Use the display users command to view information about users connected to the switch. Examples # Display the information about all the active users on the console. display users UI Delay Type Ipaddress Username + 0 CON 0 00:00:00 + 130 VTY 0 00:00:05 TEL 192.168.1.253 tb # Display the information about all the users on the console. display users all

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-10 UI Delay Type Ipaddress Username + 0 CON 0 00:00:00 129 AUX 0 + 130 VTY 0 00:00:16 TEL 192.168.1.253 tb 131 VTY 1 132 VTY 2 133 VTY 3 134 VTY 4 Table 1-4 display users command output description Field Description + Information about an active user UI The first number is the absolute number of the UI (user interface), and the second number is the relative number of the UI. Delay The time elapsing after the last user input, in the format of hh:mm:ss Type User type, such as Telnet, SSH, PAD Ipaddress Initial connection location, that is, the IP address of the incoming host Username Name of the user who uses this UI, that is, the login username of this user. If the current terminal line is in anonymous login mode (AAA authentication is enabled on it), this field is null 1.2.6 display version Syntax display version View Any view Parameters None Description Use the display version command to view such information as software version, issue date and the basic hardware configurations. Examples # Display the information about the system version.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-11 display version H3C Comware Platform Software Comware software, Version 3.10, Feature 1631 Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. All rights reserved. H3C S9505 uptime is 0 week, 2 days, 4 hours, 19 minutes LSB1SRP1N6 1: uptime is 0 week,2 days,4 hours,19 minutes H3C S9500 with 1 MPC755 Processor 512M bytes SDRAM 16384K bytes Flash Memory 512K bytes NVRAM Memory PCB Version : Ver.B BootROM Version : 123 CPLD Version : 001 Software Version : S9500-CMW310-F1631 LSB1GT12B0 3: uptime is 0 week,2 days,4 hours,17 minutes H3C S9500 LPU with 1 MPC8245 Processor 128M bytes SDRAM 0K bytes NVRAM Memory PCB Version : REV.0 BootROM Version : 103 1.3 System Debugging Commands 1.3.1 debugging Syntax debugging { all | timeout interval | module-name [ debugging-option ] } undo debugging { all | module-name [ debugging-option ] } View User view Parameters all: Enables or disables all the debugging. timeout interval: Specifies the interval (in minutes) during which the debugging all switch is on. The value ranges from 1 to 1440. With this configuration, all debugging takes the time at which it is enabled as the start time, and takes effect during the predefined time. And after that, all debugging is disabled.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-12 module-name: Module name. debugging-option: Debugging option. Description Use the debugging command to enable the system debugging. Use the undo debugging command to disable the system debugging. By default, all the debugging processes are disabled. The switch provides various kinds of debugging functions for technical support personnel and experienced maintenance staff to troubleshoot the network. Enabling the debugging will generate a large amount of debugging information and decrease the system efficiency. Specially, network system may collapse after all the debugging is enabled by the debugging all command. So it is not suggested to use the debugging all command. It is convenient for the user to disable all the debugging with undo debugging all command. Related commands: display debugging. Examples # Enable IP packet debugging. debugging ip packet display debugging IP packet debugging is on The above output shows that the IP packet debugging is enabled. 1.3.2 display diagnostic-information Syntax display diagnostic-information View Any view Parameters None Description Use the display diagnostic-information command to view the current configuration information about all running modules. You can use all the information to help diagnose and troubleshoot the switch. When the switch does not run well, you can collect all sorts of information about the switch to locate the source of fault. However, each module has many corresponding

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-13 display commands, which makes it difficult for you to collect all the information needed. In this case, you can use display diagnostic-information command. � Note: Before executing the display diagnostic-information command, configure the terminal debugging & terminal monitor commands in user view first. Examples # Display all system configuration information. This operation may take a few minutes, continue?[Y/N]y -------------------- display version -------------------- H3C Comware Platform Software Comware Software, Version 3.10, Feature 1631 Comware Platform Software Version COMWAREHZV300R001B10D015 H3C S9505 Software Version V100R006B01D015 H3C S9505 Product Version S9500-CMW310-F1631(EI) Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. All rights reserved. H3C S9505 uptime is 0 week, 2 days, 4 hours, 46 minutes This device is H3C S9505E LSB1SRP1N6 1: uptime is 0 week,2 days,4 hours,46 minutes H3C S9500 with 1 MPC755 Processor 512M bytes SDRAM 16384K bytes Flash Memory 512K bytes NVRAM Memory PCB Version : Ver.B BootROM Version : 123 CPLD Version : 001 Software Version : S9500-CMW310-F1631 LSB1GT12B0 3: uptime is 0 week,2 days,4 hours,44 minutes H3C S9500 LPU with 1 MPC8245 Processor 128M bytes SDRAM 0K bytes NVRAM Memory PCB Version : REV.0 BootROM Version : 103

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-14 CPLD Version : 005 Software Version : S9500-CMW310-F1631 CPUCard 1 PCB Ver : REV.0 CPLD Ver : 001 SubCard 1 PCB Ver : Ver.A CPLD Ver : NONE SubCard 2 PCB Ver : Ver.A CPLD Ver : NONE SubCard 3 PCB Ver : Ver.A CPLD Ver : NONE 1.4 Network Connection Test Commands 1.4.1 ping Syntax ping [ ip ] [ -a ip-address | -c count | -d | -h ttl | -i { interface-type interface-num | interface-name } | -n | - p pattern | -q | -r | -s packetsize | -t timeout | -tos tos | -v | -vpn-instance vpn-instance-name ] * host View Any view Parameters -a ip-address: Specifies the source IP address of an ICMP echo request (ECHO-REQUEST). -c count: Specifies the number of ICMP echo requests sent, in the range 1 to 4294967295. The default value is 5. -d: Sets socket to DEBUGGING mode. The default is non-DEBUGGING mode. -h ttl: Specifies the TTL value for an ICMP echo request, in the range 1 to 255. The default value is 255. interface-type: Interface type. interface-num: Interface number. interface-name: Interface name. -i: Specifies the ICMP echo request sending interface.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-15 -n: Specifies that the host argument is used as the IP address, without domain name resolution performed. By default, host is taken as the IP address, and if host is not an IP address, domain name resolution will be performed. -p: Specifies the padded bytes in an ICMP echo request, in hexadecimal format. For example, if pattern is configured as ff, then the packets will be padded with ff. By default, the padded bytes start from 0x01 up to 0x09, where another round starts again if necessary. -q: Presence of this keyword indicates that only statistics are displayed. By default, all information is displayed. -r: Records routes. By default, routes are not recorded. -s packet-size: Specifies length (in bytes) of an ICMP echo request (excluding the IP and ICMP header). The default value is 56. -t timeout: Specifies the timeout value (in milliseconds) of an ICMP echo reply (ECHO-REPLY). It defaults to 2000 ms. -tos tos: Specifies type of service (ToS) of an echo request, in the range 0 to 255. The default value is 0. -v: Displays non ICMP echo replies received. By default, the system does not display non ICMP echo replies. -vpn-instance vpn-instance-name: Specifies the name of a VPN instance. host: IP address or domain name of the destination host. ip: Specifies that IP ICMP packets are used. Description Use the ping command to check host reachability and network connectivity in an IP or IPX network. The ping command involves the following steps in its execution: 1) The source device sends an ICMP echo request to the destination host. 2) If the network is functioning properly, the destination host responds by sending an ICMP echo reply to the source device after receiving the ICMP echo request. You can use the ping command to test network connectivity and connection quality. Output of the ping command falls into the following: � Information on the destination’s responses towards each ICMP echo request. If the source device does not receive an ICMP echo reply within the timeout time, it displays the prompt information “Request time out.”; otherwise, it displays the number of bytes of the echo reply, the message sequence number, Time to Live (TTL), the response time. � The statistics during the ping operation, which include number of packets sent, number of echo reply messages received, percentage of messages not received, and the minimum, average, and maximum response time.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-16 If the network transmits data rather slowly, you can set a bigger timeout. Related commands: tracert. Examples # Check whether the host with an IP address of 202.38.160.244 is reachable. ping 202.38.160.244 ping 202.38.160.244 : 56 data bytes Reply from 202.38.160.244 : bytes=56 sequence=1 ttl=255 time = 1ms Reply from 202.38.160.244 : bytes=56 sequence=2 ttl=255 time = 2ms Reply from 202.38.160.244 : bytes=56 sequence=3 ttl=255 time = 1ms Reply from 202.38.160.244 : bytes=56 sequence=4 ttl=255 time = 3ms Reply from 202.38.160.244 : bytes=56 sequence=5 ttl=255 time = 2ms --202.38.160.244 ping statistics-- 5 packet transmitted 5 packet received 0% packet loss round-trip min/avg/max = 1/2/3 ms 1.4.2 pingmac Syntax pingmac mac-address vlan vlan-id View Any view Parameters mac-address: MAC address of the destination host. The format is H-H-H. vlan-id: VLAN that the destination host belongs to, in the range of 1 to 4094. Description Use the pingmac command to check the layer-2 network connection and the reachability of the host.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-17 � Note: � At present, the pingmac command only supports detection of hosts in the same VLAN. � Before executing the pingmac command, enable ndp in system view and port view first. Related commands: tracemac. Examples # Check whether a host in VLAN 100 with the MAC address of 00f0-fc00-0110 is reachable. pingmac 00f0-fc00-0110 vlan 100 destination reachable 1.4.3 tracert Syntax tracert [ -a source-IP | -f first-TTL | -m max-TTL | -p port | -q num-packet | -vpn-instance vpn-instance-name | -w timeout ] string View Any view Parameters -a source-IP: Specifies the source IP address of a tracert packet. It must be a legal IP address configured on the device. -f first-TTL: Specifies the first TTL, that is, the allowed number of hops for the first packet. first-TTL defaults to 1 and must be greater than 0 and less than the maximum TTL. -m max-TTL: Specifies the maximum TTL, that is, the maximum allowed number of hops for a packet. max-TTL defaults to 30, and must be greater than the first TTL. -p port: Specifies the UDP port number of the destination host. The default value is 33434. You do not need to modify this argument. -q num-packet: Specifies the number of probe packets sent each time. num-packet is an integer greater than 0, defaulting to 3. -vpn-instance vpn-instance-name: Specifies the name of an MPLS VPN instance. -w timeout: Specifies the timeout time of the reply packet of a probe packet, in seconds. timeout is an integer greater than 0, defaulting to 5.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-18 string: IP address of the destination host or host name of the remote system. Description Use the tracert command to trace the gateways involved in delivering a packet from source to destination. This is useful for identification of failed node(s) in the event of network failure. The tracert command involves the following steps in its execution: 1) The source device sends a packet with a TTL value of 1 to the destination. 2) The first hop responds by sending a TTL-expired ICMP message to the source, with its IP address encapsulated. In this way, the source device can get the address of the first gateway. 3) The source device sends a packet with a TTL value of 2 to the destination. 4) The second hop responds with a TTL-expired ICMP message, which gives the source device the address of the second gateway. The above process continues until the ultimate destination is reached. In this way, the source device can trace the addresses of all the gateways involved to get to the destination. After having identified network failure with the ping command, you can use the tracert command to determine the failed node(s). Output information of the tracert command includes IP addresses of all the gateways the packets traverse from the source to the destination. If a gateway times out, "* * *" will be displayed. Caution: At present, the device does not support check of whether a network is reachable using the tracert command and identification of failed node(s) in the event of network failure in an MPLS domain. Examples # Display the routers the packets traverse from the source device to the destination device with an IP address of 18.26.0.115. tracert 18.26.0.115 tracert to allspice.lcs.mit.edu (18.26.0.115), 30 hops max 1 helios.ee.lbl.gov (128.3.112.1) 0 ms 0 ms 0 ms 2 lilac-dmc.Berkeley.EDU (128.32.216.1) 19 ms 19 ms 19 ms 3 lilac-dmc.Berkeley.EDU (128.32.216.1) 39 ms 19 ms 19 ms 4 ccngw-ner-cc.Berkeley.EDU (128.32.136.23) 19 ms 39 ms 39 ms

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-19 5 ccn-nerif22.Berkeley.EDU (128.32.168.22) 20 ms 39 ms 39 ms 6 128.32.197.4 (128.32.197.4) 59 ms 119 ms 39 ms 7 131.119.2.5 (131.119.2.5) 59 ms 59 ms 39 ms 8 129.140.70.13 (129.140.70.13) 80 ms 79 ms 99 ms 9 129.140.71.6 (129.140.71.6) 139 ms 139 ms 159 ms 10 129.140.81.7 (129.140.81.7) 199 ms 180 ms 300 ms 11 129.140.72.17 (129.140.72.17) 300 ms 239 ms 239 ms 12 * * * 13 128.121.54.72 (128.121.54.72) 259 ms 499 ms 279 ms 14 * * * 15 * * * 16 * * * 17 * * * 18 ALLSPICE.LCS.MIT.EDU (18.26.0.115) 339 ms 279 ms 279 ms 1.4.4 tracemac enable Syntax tracemac enable undo tracemac enable View System view Parameters None Description Use the tracemac enable command to enable the TraceMac&Ping Mac function of the system. Use the undo tracemac enable command to disable the TraceMac&Ping Mac function. � Note: The tracemac&pingmac functions cannot go without the support of NDP, and will not work if NDP and tracemac are disabled. By default, NDP is disabled. By default, the TraceMac and Ping Mac functions are disabled on the switch. Related commands: tracemac.

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-20 Examples # Enable the TraceMac and Ping Mac functions of the system. system-view System View: return to User View with Ctrl+Z. [H3C] tracemac enable 1.4.5 tracemac Syntax tracemac { by-mac mac-address vlan vlan-id | by-ip ip-address } [ nondp ] View Any view Parameters mac-address: MAC address of the destination host. The format is H-H-H. vlan-id: VLAN that the destination host belongs to, in the range of 1 to 4094. ip-address: IP address of the destination host. nondp: The NDP function is not used when you execute the tracemac command. By default, the NDP function is enabled. Therefore, you need to enable the NDP function on an interface. Description Use the tracemac command to test the integrity of a path on the network, and thus to acquire information about the network failure, the port(s) from which network attacks were originated, the device and its ports connected to the network using a specific MAC address. Examples # Test the devices traversed by the packet sent to a destination host that belongs to VLAN 100 and has an MAC address of 000f-3232-0007. tracemac by-mac 000f-3232-0007 vlan 100 tracemac by-mac 000f-3232-0001 vlan 100 1 000f-3232-0002 H3C01 ethernet0/2 2 000f-3232-0003 H3C02 ethernet0/2 3 000f-3232-0004 H3C03 ethernet0/2 4 000f-3232-0005 H3C04 ethernet0/2 5 000f-3232-0006 H3C05 ethernet0/2 6 000f-3232-0007 local

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-21 1.5 Command Line Parser Cache Function Commands 1.5.1 parser cache Syntax parser cache undo parser cache View System view Parameters None Description Use the parser cache command to enable the command line parser cache function of the system. Use the undo parser cache command to disable the command line parser cache function of the system. By default, the command line parser cache function of the system is disabled. Related commands: display parser statistic Examples # Enable the command line parser cache function. system-view System View: return to User View with Ctrl+Z. [H3C] parser cache 1.5.2 display parser statistic Syntax display parser statistic View Any view Parameters None

Command Manual – System Maintenance and Debugging

H3C S9500 Series Routing Switches Chapter 1 System Maintenance and Debugging Commands 1-22 Description Use the display parser statistic command to query the state (enabled or disabled) of the parser cache function and statistics information. Examples # Query the parser cache statistics. display parser statistic Parser cache:enabled, 512 hits, 153 misses The above output shows the parser cache function is enabled. In the above output, 512 hits and 153 misses mean that in the parser cache process 512 commands are matched and 153 commands are not matched.