D S E 9 7 0 1 & DS E 9 7 0 2 B AT T ER Y C HA RG ER I N ST AL L AT I O N I N ST R UC T I O NS 053-170 ISSUE 1 DANGER OF DEATH : LIVE PARTS exist within the Battery Charger enclosure. The enclosure cover must not be removed. Installation The DSE9701 (24V 5A) & DSE9702 (12V 5A) battery chargers are designed to be mounted vertically within a control panel, on the panel DIN rail utilising the integral mounts or on a chassis utilising the mounting holes. For dimension and mounting details, see overleaf. DSE battery chargers are fit-and-forget. They are permanently connected to the supply and the load, with no requirement to disable the charger during times of heavy load (such as engine cranking) or when in parallel with a charging alternator. Battery Suitability The charger is factory set by DSE to suit Lead Acid batteries but can be adjusted at the time of ordering to suit other battery types. Care must be taken to ensure the batteries connected to the charger are of the correct ‘technology’ to suit the setting of the charger. Indications The Battery Chargers feature an LED indicator(s) to show the battery charger Status. (Refer to DSE publication: 057-085 DSE9xxx Series Operator Manual for further information) Boost Mode Boost mode is operated by connecting the BOOST terminals together for instance with an external switch or timer circuit. This will raise the battery charger floating voltage by 0.8V DC. Typical Wiring Diagram NOTE : This document is intended as a ‘quick start’ guide only. For full operating instructions and specifications, refer to DSE publication: 057-085 DSE9xxx Series Operator Manual. Connection Type Screw Terminal, Rising Clamp, No Internal Spring Min Cable Size 0.5mm² (AWG 20) Max Cable Size 2.5mm² (AWG 14) DSE9701 AC Fuse (230 V AC Supply) 2.0 A Anti-Surge DSE9701 AC Fuse (110 V AC Supply) 3.5 A Anti-Surge DSE9702 AC Fuse (230 V AC Supply) 1.0 A Anti-Surge DSE9702 AC Fuse (110 V AC Supply) 2.0 A Anti-Surge

Dimensions and Mounting

Overall Size for DIN Rail Mounting 47.5 mm x 152.8 mm x 111.2 mm (1.9” x 6.0” x 4.4”) Overall Size for Chassis Mounting 47.5 mm x 133.0 mm x 111.2 mm (1.9” x 5.2” x 4.4”) Weight 0.4 kg Mounting Type DIN Rail or Chassis Mounting DIN Rail Type EN 50022 35 mm Type Only Mounting Holes (DIN Rail Clips Pushed Outwards to Reveal Mounting Holes) Suitable for M4 Mounting Hole Centres 140.8 mm (5.5”) Input Voltage (Nominal) 110 V - 277 V Input Voltage (Absolute Range) 90 V - 305 V Charge Failure Relay Rating 3 A DC Resistive, 30 V Maximum Operating Temperature -30 °C to 55 °C (-22 °F to 131 °F) Over Temperature Protection Above 70 ºC (158 ºF) the maximum output current is limited to protect the device. This limiting increases linearly as temperature increases until at 100 ºC (212 ºF), the maximum output current is limited to 1 A DC. Chassis Mounting DIN rail Mounting Dimensions Dimensions in mm unless otherwise specified Deep Sea Electronics Plc. Tel:+44 (0)1723 890099 Fax: +44 (0)1723 893303 Email: [email protected] Web: www.deepseaplc.com Deep Sea Electronics Inc. Phone: +1 (815) 316-8706 Fax: +1 (815) 316- 8708 Email: [email protected] Web: www.deepseausa.com

Other Battery Charger Manuals