Trademarks The Emerson logo is a trademark and service mark of Emerson Electric Co. AMS is a mark of one of the Emerson group of companies. FOUNDATION™ is a mark of the FieldComm Group of Austin, Texas, USA. Microsoft and Windows are registered trademarks of the Microsoft Corporation in the United States and/or other countries. PACTware is a trademark of PACTware Consortium e.V. All other marks are property of their respective owners. Contents Introduction ................................................. 3 USB Fieldbus Interface .................................. 5 Software installation and device setup ........10 USB Fieldbus Interface Configuration utility ..........................................................17 Using with AMS Device Manager .................25 Using with an FDT Frame Application ..........33 Troubleshooting .........................................44 Approvals and certifications ........................48 Specifications ............................................. 49 Waste disposal ............................................50 Remove pre-release driver versions on a Windows 7 or 10 operating system .............51 User's Manual January 2019 2

This manual guides you in using the USB Fieldbus Interface to power and/or

configure fieldbus devices. Included here are basic setup, configuration, and troubleshooting information, as well as guidelines on how to use the interface with AMS Device Manager and with a third-party FDT Frame Application. This USB Fieldbus Interface User's Manual contains the following information: • Chapter 1: Introduction – contains safety messages and information about this manual. • Chapter 2: USB Fieldbus Interface – contains information about the interface, its parts, usage, and features. • Chapter 3: Software installation and device setup – contains system requirements, software installation instructions, and device setup information. • Chapter 4: USB Fieldbus Interface Configuration utility – contains information on how to use the utility to power, commission, and/or configure some parameters of fieldbus devices, including device address and tag. • Chapter 5: Using with AMS Device Manager – contains setup information and instructions in using the interface with AMS Device Manager to configure fieldbus devices. • Chapter 6: Using with an FDT Frame Application – contains setup information and instructions in using the interface with an FDT Frame Application to configure fieldbus devices. • Chapter 7: Troubleshooting – contains solutions to the most common operating problems. • Appendix A: Approvals and certifications – contains certifications and approval information. • Appendix B: Specifications – contains specifications such as operating temperature, software, electrical information, and environmental considerations. • Appendix C: Waste disposal – contains disposal guidelines. • Appendix D: Remove pre-release driver versions on a Windows 7 or 10 operating system – contains instructions on how to remove previous driver versions. January 2019 User's Manual 3

Do not connect the USB Fieldbus Interface to a live segment (with an active

DCS Host and power supply attached) if the power indicator light on the interface is amber in color. Doing so can disrupt communications and may compromise automation safety. User's Manual January 2019 4

USB Fieldbus Interface

Topics covered in this chapter: • Overview • Parts and function • Power modes 2.1 Overview The USB Fieldbus Interface enables two-way communication between a computer and fieldbus devices. Its primary function is to allow the setup, configuration, monitoring, and troubleshooting of fieldbus devices at any valid FF address through a computer. The interface is fully compatible with all FOUNDATION fieldbus (FF) devices and is always configured as a "visitor." It is particularly useful in these plant scenarios: • Workbench setup and troubleshooting of fieldbus devices • With a laptop in the field to configure, commission, decommission, set device address, or troubleshoot fieldbus devices The USB Fieldbus Interface comes with a USB cable, lead set, user's manual*, and installation CD/DVD*. The user's manual and installation CD/DVD are not included in the illustration. January 2019 User's Manual 5

Parts and function

USB Fieldbus Interface Figure 2-2: 1 Field connection indicator light (*) Indicates the fieldbus device connection status 2 Power indicator light (*) Indicates the power mode of the interface 3 USB port Enables USB connection 4 Fieldbus device connection socket Enables fieldbus device or segment connection (*) See the Indicator light scenarios table. January 2019 User's Manual 7

Indicator light scenarios

Table 2-1: Power indicator light Field connection indicator light Scenarios Normal scenarios Green Green The USB Fieldbus Interface is connected to an externally powered segment and is able to communicate. Amber Green The USB Fieldbus Interface is providing power to a fieldbus segment and is able to communicate. Other scenarios Off Off The USB Fieldbus Interface is not connected to a powered computer. -OR- The USB Fieldbus Interface is connected to a computer but the computer power is off. -OR- The USB FF HSE Server is not running on the connected computer. Green Off The USB Fieldbus Interface is not connected to a powered segment. -OR- The USB Fieldbus Interface is connected to a powered segment with the wrong polarity. Off Green The USB Fieldbus Interface is connected normally to a powered segment but the USB FF HSE Server is not running. Amber Red The USB Fieldbus Interface is providing power but a short circuit has been detected on the field connection. Amber Off The USB Fieldbus Interface is providing power and connected to an already powered fieldbus segment with reverse polarity. Amber Amber The USB Fieldbus Interface is providing power to a fieldbus segment and the load on that segment has exceeded its limit. User's Manual January 2019 8

The USB Fieldbus Interface has two power modes:

• Mode 1 - The interface does not supply power to the connected fieldbus device or segment. The fieldbus device or segment is powered by an external source. Mode 1 is the default. • Mode 2 - The interface powers the connected fieldbus device or segment and no external power is needed. In Mode 2, it can provide current of up to 85 mA (typically sufficient for three or four fieldbus devices on the same segment). You can configure Mode 2 using the USB Fieldbus Interface Configuration utility. For more information, see Section 4.3. WARNING! Choose only one power mode. Never attempt to use two power sources at the same time. Doing so can disrupt communications and may compromise automation safety. January 2019 User's Manual 9

Software installation and device setup

Topics covered in this chapter: • System requirements • Install the USB Fieldbus Interface Configuration utility • Install the Communication DTM software • Install the Emerson DTM Library • Setup and connection • Connect to a live fieldbus segment Perform software installation and device setup in the following order: 1. Install the USB Fieldbus Interface Configuration utility. This allows you to configure the USB Fieldbus Interface and connected fieldbus devices. 2. Install the Communication DTM software. This enables DTM support for connected fieldbus devices. 3. Install the Emerson DTM Library. This allows you to use DTMs associated with Emerson devices through an FDT Frame Application. Note Device DTMs are usually acquired from device suppliers. Contact your device supplier if you have a non-Emerson device and install the appropriate third-party DTM library. 4. Set up and configure connected fieldbus devices. 3.1 System requirements Supported operating systems Windows 7 (32- or 64-bit) Windows 10 Hard disk space 500MB or more Hardware User's Manual January 2019 10

USB 1.1 or USB 2.0 port

3.2 Install the USB Fieldbus Interface Configuration utility Notes • Do not connect the USB Fieldbus Interface to the computer or to a fieldbus device or segment until software installation is complete. • You may be prompted to determine the operating system and the Windows version (32-bit or 64-bit) running on your computer. Keep this information handy. • For installation purposes, the user must use the Administrator account. 1. Insert the USB Fieldbus Interface installation CD/DVD. Software and driver installation should start automatically. If AutoRun is not enabled, double-click setup.exe. 2. Follow the prompts on the installation window. 3. Click Finish. 3.3 Install the Communication DTM software 1. Insert the USB Fieldbus Interface installation CD/DVD. 2. Navigate to the Emerson USB Fieldbus Interface DTM folder and double- click Setup.exe. 3. Click Next and follow the prompts on the installation window. January 2019 User's Manual 11

Communication DTM installation

Figure 3-1: 4. Click Finish. 3.4 Install the Emerson DTM Library 1. Insert the USB Fieldbus Interface installation CD/DVD. 2. Navigate to the Emerson DTM Library folder. The DTM library folder is typically named "Emerson Process Management FF Device DTM Library v1.x.x". 3. Double-click Setup > Setup.exe. 4. Click Next and follow the prompts on the installation window. User's Manual January 2019 12

Setup and connection

Note Install the USB Fieldbus Interface Configuration utility first before setting up and connecting the USB Fieldbus Interface. For more information, see Section 3.2 1. Connect the USB Fieldbus Interface to the computer using the USB cable provided. USB driver installation should start automatically. 2. Connect the interface to a fieldbus device or to a fieldbus segment using the field leads. WARNING! Do not proceed to the next step if you are connecting to a live (powered) segment. Providing additional power source to an already powered segment can disrupt communications and may compromise automation safety. 3. Power the connected fieldbus device or segment. Connect the fieldbus device or the unpowered segment to an external power source (Mode 1), or provide power using the USB Fieldbus Interface Configuration utility (Mode 2). For more information on the power modes, see Section 2.3. User's Manual January 2019 14

Sample benchtop connection

Figure 3-3: 3.6 Connect to a live fieldbus segment WARNING! Do not use the Supply Power option on the USB Fieldbus Interface Configuration utility when connecting to a live segment. Doing so can disrupt communications and may compromise automation safety. 1. Make sure the USB Fieldbus Interface is connected to the computer and that all software and drivers are installed. 2. Plug one end of the field lead to the fieldbus device connection socket of the interface and connect the other end to the live fieldbus segment. Notes • The USB Fieldbus Interface draws current of 10 mA from the segment. Make sure the segment has enough power and has the capacity to provide this additional current. • Make sure the lead set is connected to the live fieldbus segment with the correct polarity. • Changing the device tag/address is only allowed when the USB fieldbus Interface is acting as Link Active Scheduler (LAS). January 2019 User's Manual 15

• When a fieldbus device is acting as a LAS, you can cycle power to the

device, or remove and replace the fieldbus device from the segment to make the USB Fieldbus interface act as the LAS. You can check the LAS address next to the segment info to find out which device is the LAS. User's Manual January 2019 16

USB Fieldbus Interface Configuration utility

Topics covered in this chapter: • Launch the USB Fieldbus Interface Configuration utility • Start or stop the USB FF HSE Server manually • Power fieldbus device with the USB Fieldbus Interface Configuration utility • Set Fieldbus Device Permanent Address/Tag • Set Fieldbus Device Default Address • Change the device class 4.1 Launch the USB Fieldbus Interface Configuration utility Click Start > All Programs > Emerson Process Management > USB Fieldbus Interface. Note If no fieldbus device is detected after 35 seconds, this dialog is displayed. Click OK to continue. No device detected dialog Figure 4-1: A connected fieldbus device or segment has to be powered by an external power source or by the USB Fieldbus Interface Configuration utility for it to be detected. For more information, see Section 7.2. 4.2 Start or stop the USB FF HSE Server manually The USB FF HSE Server automatically starts when you launch the USB Fieldbus Interface Configuration utility. It is typically not necessary to start or stop the USB FF HSE Server manually. January 2019 User's Manual 17

1. Launch the USB Fieldbus Interface Configuration utility.

2. Click Start Server or Stop Server. Start Server/Stop Server Figure 4-2: Note The USB FF HSE Server should be running to use the USB Fieldbus Interface Configuration utility to power or configure a fieldbus device or segment. User's Manual January 2019 18

Power fieldbus device with the USB Fieldbus Interface

Configuration utility You can power a fieldbus device or segment by connecting it to an external power source or by using the USB Fieldbus Interface Configuration utility. Note You can also power a fieldbus device or segment by connecting it to an external power source. 1. Launch the USB Fieldbus Interface Configuration utility. 2. Select the Supply Power check box. Note The USB Fieldbus Interface is only capable of providing an output current of up to 85 mA. Typically, you should not attempt to connect more than three or four fieldbus devices on the same segment when using the Supply Power option. Supply Power option Figure 4-3: January 2019 User's Manual 19

Do not use the Supply Power option on a live (already powered) segment.

Doing so can disrupt communications and may compromise automation safety. 3. Select Yes to acknowledge the warning and restart the USB FF HSE Server. 4.4 Set Fieldbus Device Permanent Address/Tag Device Address can be set to permanent, which commissions the device. Device Tag can be set and cleared. Notes • You need to commission fieldbus devices first before you can use them with AMS Device Manager or with an FDT Frame Application. • The USB Fieldbus Interface must be acting as the Link Master to commission or decommission. 1. Launch the USB Fieldbus Interface Configuration utility. 2. Double-click the Fieldbus device icon you want to configure. A device screen is displayed. Note A connected fieldbus device or segment should be powered by an external power source or by the USB Fieldbus Interface Configuration utility for it to be detected. 3. Optionally, select a permanent device address from 17 to 40 or from 223 to 247. Otherwise, the first available address is assigned. Note The utility only accepts device addresses in the range of 17 through 40 and the range of 223 through 247. 4. Optionally, enter a device tag or clear a device tag. 5. Click Apply to accept the new tag. Or, click Set Permanent Address and Tag to accept both the permanent device address and the tag. User's Manual January 2019 20

Set Permanent Address and Tag

Figure 4-4: Note The set permanent address and tag process takes about 1 to 2 minutes to complete. 6. Repeat steps 2 through 5 for each device on which you want to set a permanent address. 4.5 Set Fieldbus Device Default Address Device address can be set to a default address, which decommissions the device. Note Fieldbus devices on a live segment cannot be decommissioned. 1. Launch the USB Fieldbus Interface Configuration utility. 2. Double-click the Fieldbus device icon you want to configure. A device screen is displayed. Note A connected fieldbus device or segment should be powered by an external power source or by the USB Fieldbus Interface Configuration utility for it to be detected. January 2019 User's Manual 21

3. Click Set Default Address.

Set Default Address Figure 4-5: 4. If the device was set to a permanent address by a different host, it is not recommended that you set the device to a Default Address. If you click the Set Default Address button, you will be asked to confirm if you really want to set the device to a default address. • If you select Yes, the device will be set to a default address. • If you select No, the operation will be canceled. 5. Repeat steps 2 through 4 for each device you want to set to a default address. 4.6 Change the device class A connected fieldbus device can be assigned as a Link Master (LM) or as a basic device. A Link Master contains the LAS functionality that controls communications on a fieldbus link or segment. 1. Launch the USB Fieldbus Interface Configuration utility. 2. Double-click the Fieldbus device icon you want to configure. A device screen is displayed. User's Manual January 2019 22

A connected fieldbus device or segment should be powered by an

external power source or by the USB Fieldbus Interface Configuration utility for it to be detected. 3. If Device Class is not displayed, click Read to identify if the fieldbus device is a Link Master or a basic device. Note Only the device class of a fieldbus device at a permanent address can be identified. For more information on setting a permanent device address, see Section 4.4. Identify the device class Figure 4-6: 4. Switch to Basic or Link Master from the drop-down menu and click Apply. January 2019 User's Manual 23

Change the device class

Figure 4-7: 5. Click Yes to acknowledge the restart of the device. 6. Click OK to continue. The operation is complete when the Apply button is grayed out. Note Changing the device class takes about 1 minute to complete. User's Manual January 2019 24

Using with AMS Device Manager

Topics covered in this chapter: • Add a network component in AMS Device Manager • Configure fieldbus devices in AMS Device Manager AMS Device Manager provides a single application for predictive diagnostics, documentation, calibration management, and device configuration. Using AMS Device Manager gives you better visibility into the assets in your plant, resulting in faster startup and increased availability through more cost- effective maintenance and improved asset performance. Contact your Emerson Sales/Support representative for more information on AMS Device Manager. 5.1 Add a network component in AMS Device Manager An FF HSE network component is required to use the USB Fieldbus Interface with AMS Device Manager. Notes • If there is an existing FF HSE network configured for another fieldbus device, you do not need to add a new FF HSE network component. • You must have an updated license file that includes an HSE license. The HSE license enables you to add an FF HSE network component in AMS Device Manager. If you do not yet have an HSE license, contact your Emerson sales representative and place an order for part number AW7060HSE. 1. Click Start > All Programs > AMS Device Manager > Network Configuration to open the AMS Device Manager Network Configuration utility. 2. Click Add. January 2019 User's Manual 25

Add a network component

Figure 5-1: 3. Select the FF HSE Network component, and click Install. User's Manual January 2019 26

Install an FF HSE network component

Figure 5-2: 4. Click Next. 5. Enter a name for the FF HSE network, and click Next. January 2019 User's Manual 27

Enter a network name

Figure 5-3: 6. Choose to automatically discover FF HSE linking devices or manually configure IP addresses for FF HSE linking devices. User's Manual January 2019 28

Configure the network connection

Figure 5-4: Notes • Choosing the PC NIC address in the Primary HSE NIC Address field displays the USB Fieldbus Interface and any local FF HSE interfaces on the network in the AMS Device Manager hierarchy. • Choosing the localhost address (127.0.0.1) in the Primary HSE NIC Address field displays only the USB Fieldbus Interface in the AMS Device Manager hierarchy. January 2019 User's Manual 29

• Manually entering IP addresses displays manually entered FF HSE

networks and the USB Fieldbus Interface in the AMS Device Manager hierarchy. • The USB Fieldbus Interface does not support FF device alerts. 7. Click Finish. 5.2 Configure fieldbus devices in AMS Device Manager Note Commission fieldbus devices first in the USB Fieldbus Interface Configuration utility before configuring them in AMS Device Manager. For more information, see Section 4.4. 1. Click Start > All Programs > AMS Device Manager > AMS Device Manager to open AMS Device Manager. 2. From the Device Connection or Device Explorer view, right-click the FF HSE network icon and select Rebuild Hierarchy. The USB Fieldbus Interface icon then appears under the FF HSE network. USB Fieldbus Interface icon in AMS Device Manager Figure 5-5: User's Manual January 2019 30

If you are using the Device Connection View, click the

sign next to the USB Fieldbus Interface icon to display a list of connected fieldbus devices. 4. If necessary, right-click the USB Fieldbus Interface icon and then scan new devices. Scanning synchronizes the AMS Device Manager database with connected live devices. 5. Right-click the fieldbus device you want to configure and select from the context menus. Fieldbus device context menus Figure 5-6: Configure Displays configuration parameters that define the physical attributes and operating characteristics of the device. Compare Lets you compare two configurations of the device. January 2019 User's Manual 31

Service Tools or

Device Diagnostics Displays alert conditions. These include hardware and software malfunctions or parameters with values beyond the device specifications. Overview or Process Variables Displays the current output from the device. For more information about the context menus and other AMS Device Manager functions, refer to AMS Device Manager Books Online. User's Manual January 2019 32

Using with an FDT Frame Application

Topics covered in this chapter: • Install an FDT Frame Application • Update the DTM library • Configure fieldbus devices in an FDT Frame Application You can also configure fieldbus devices using third-party FDT Frame Applications. For the purpose of this document, PACTware is used as an example. PACTware can be downloaded from multiple sites on the Internet. 6.1 Install an FDT Frame Application Note Install the Communication DTM software and the Emerson DTM Library first before installing an FDT Frame application. For instructions, see Section 3.3 and Section 3.4. To be able to view DTMs associated with a device, an FDT Frame Application should be installed. Follow the manufacturer's recommended software installation instructions. For the purpose of this document, PACTware is used. 6.2 Update the DTM library Note You only need to update the DTM library when a new DTM is recently added. 1. Launch PACTware. 2. Press F3 to show the Device catalog and click Update device catalog. January 2019 User's Manual 33

Update device catalog

Figure 6-1: 3. Click Yes when prompted to create a new PACTware device catalog. 4. Close the device catalog when done. 6.3 Configure fieldbus devices in an FDT Frame Application Notes • Install the Communication DTM software and the DTM Library first before configuring fieldbus devices in an FDT Frame Application. For more information, see Section 3.3 and Section 3.4. • If necessary, update the DTM library. For more information, see Section 6.2. • Make sure the USB Fieldbus Interface and fieldbus devices are correctly set up and that the USB Fieldbus Interface Configuration utility is installed and running. For more information, see Section 3.5 and Chapter 4. 1. Launch PACTware. 2. From the Project pane, right-click HOST PC and click Add device. User's Manual January 2019 34

Press F2 to display the Project pane if it is not already displayed.

3. Select Emerson FF HSE Server and click OK. Add the Emerson FF HSE Server Figure 6-3: 4. Right-click FF HSE Server on the Project pane and click Add device. January 2019 User's Manual 35

FF HSE Server - Add device

Figure 6-4: 5. Select Emerson USB Fieldbus Interface and click OK. User's Manual January 2019 36

Add the Emerson USB Fieldbus Interface

Figure 6-5: 6. Right-click USB Fieldbus Interface on the Project pane and click Add device. January 2019 User's Manual 37

USB Fieldbus Interface - Add device

Figure 6-6: 7. Select the device you want to add then click OK. User's Manual January 2019 38

Only devices with DTMs available and installed appear on the list. For

more information on DTM library installation, see Section 3.4. Repeat steps 6 and 7 if you want to add more devices to the list. 8. Right-click USB Fieldbus Interface and select Additional functions > Edit DTM Address. January 2019 User's Manual 39

Edit DTM Address

Figure 6-8: 9. On the right pane, select the fieldbus device from the list, enter the device address in the Node ID field, and click Apply. Enter Node ID Figure 6-9: User's Manual January 2019 40

The device address and Node ID should match. The device address is set

and can be found in the USB Fieldbus Interface Configuration utility. For more information on setting the device address, see Section 4.4. 10. Right-click HOST PC and click Connect. Connect devices Figure 6-10: This connects all devices under the host PC. You can also opt to select each device you want connected and click Connect. Connected devices appear in bold face type in the menu tree. 11. Right-click the fieldbus device you want to configure and click Parameter. January 2019 User's Manual 41

This displays the various parameters you can edit for the device.

12. Configure the parameters of the device. Note The parameter display varies and is dependent on the device manufacturer. User's Manual January 2019 42

Topics covered in this chapter:

• Fieldbus device not responding in AMS Device Manager • Fieldbus device not detected in USB Fieldbus Interface Configuration utility • Cannot edit device parameters in FDT Frame Application 7.1 Fieldbus device not responding in AMS Device Manager To configure a fieldbus device in AMS Device Manager, you must first commission the device in the USB Fieldbus Interface Configuration utility. For more information on commissioning a device, see Section 4.4. Uncommissioned devices are marked in AMS Device Manager with the (non-responding device) icon and are characterized by an empty device tag or by the device default address. Uncommissioned device in AMS Device Manager Figure 7-1: User's Manual January 2019 44

Commissioned fieldbus devices appear with their own icons in AMS Device

Manager and are characterized by a valid permanent address or by a valid device string. Commissioned device in AMS Device Manager Figure 7-2: 7.2 Fieldbus device not detected in USB Fieldbus Interface Configuration utility The USB Fieldbus Interface Configuration utility immediately detects connected fieldbus devices. If 35 seconds have elapsed and no device is detected, the following dialog is displayed. January 2019 User's Manual 45

No device detected dialog

Figure 7-3: Click OK and check for the following: • Make sure the fieldbus device or segment is powered either by an external source or by the USB Fieldbus Interface. For more information, see Section 2.3. • Make sure drivers are installed and that the hardware is ready for use. • Check that there are no loose connections and that the USB cable does not exceed 2 meters in length. • Make sure the USB FF HSE Server is running. User's Manual January 2019 46

Cannot edit device parameters in FDT Frame Application

Cannot edit device parameters in PACTware Figure 7-4: • Check the Node ID in PACTware and the Device Address in the USB Fieldbus Interface Configuration utility. The Node ID and Device Address should match. You may need to manually enter the Node ID in PACTware. For more information on entering the Node ID, see Section 6.3. • Update the DTM library. If a new DTM is added, you may need to update the DTM library. For more information, see Section 6.2. • Check physical connections. Make sure all devices are properly connected and have access to a power source. For more information, see Section 3.5. • Commission the fieldbus device. For more information, see Section 4.4. January 2019 User's Manual 47

Approvals and certifications

Fieldbus Foundation Communication FF Physical Layer Specification (IEC 61158-2) FF Physical Layer Conformance Test (FF830) CE EN 61326-1-2006, Radiated Emissions Class B, Basic Immunity Test Requirements. ETL (US and Canada) Conforms to ANSI/UL STD 60950-1; Certified to CAN/CSA STD C22.2 NO. 60950-1. IC This Class B digital apparatus complies with Canadian ICES-003, Issue 4:2004. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC This device complies with Part 15 Subpart B of the FCC Rules. Operation is subject to the following conditions: 47 CFR, Part 15:2009, §15.107, §15.109, Class B Any modifications made to this device that are not approved by Emerson may void the authority granted to the user by the FCC to operate this equipment. User's Manual January 2019 48

Supported operating systems

Windows 7 (32- or 64-bit) Windows 10 USB 1.1 and USB 2.0 interface Drivers included Application software AMS Device Manager Version 11.5 or later License AMS Device Manager HSE license Part number AW7060HSE Electrical Power consumption (Mode 1) ≤ 0.2 W Power consumption (Mode 2) at 85 mA output current ≤ 2.5 W at 50 mA output current ≤ 1.7 W Power supply to a fieldbus segment (in Mode 2) 85 mA at 10V Environmental Operating temperature -20 °C to 60 °C (-4 °F to 140 °F) Storage temperature -40 °C to 85 °C (-40 °F to 185 °F) Storage humidity 0 to 95% relative humidity January 2019 User's Manual 49

Products with the following label comply with the Waste Electrical and

Electronic Equipment (WEEE) directive, 2002/96/EC, which applies to European Union (EU) member states only. The label indicates this product should be recycled and not treated as household waste. Customers in EU member states should contact their Emerson sales representative for information on discarding any part of the USB Fieldbus Interface. For customers in all other world areas, if it is necessary to discard any part of the USB Fieldbus Interface, follow the waste disposal regulations applicable in your location. User's Manual January 2019 50

Remove pre-release driver versions on a Windows 7

or 10 operating system Uninstall the USB drivers using Windows Device Manager: 1. Launch Windows Device Manager (Start > Run, type devmgmt.msc, or device manager, and click on the found item). 2. Expand Ports (COM & LPT). 3. Connect the USB Fieldbus Interface to the computer through the USB port and wait a few seconds to see if 770 Fieldbus Interface (COMxx) appears on the list. 4. Right-click 770 Fieldbus Interface (COMxx), and select Uninstall. 5. Click OK to confirm the driver removal. 6. Expand Universal Serial Bus controllers, right-click 770 Fieldbus Interface, and select Uninstall. 7. Click OK to confirm the driver removal. January 2019 User's Manual 51

AMS Device Manager

adding network component 25 using to configure fieldbus devices 30 C change the device class 22 commission fieldbus devices 20 Communication DTM installation 11 configure fieldbus devices using AMS Device Manager 30 using PACTware 34 connect to live fieldbus segment 15 contents of box 5 D decommission fieldbus devices 21 device class, changing 22 drivers automatic installation 11 DTM library, installation 12 F features 5 FF HSE network component adding 25 field connection indicator light status 7 fieldbus device basic device 22 cannot edit device parameters 47 changing device class 22 commissioning 20 configuring, using AMS Device Manager 30 configuring, using PACTware 34 decommissioning 21 Link Master 22 live segment connection and setup 15 not detected in utility, troubleshooting 45 not responding in AMS Device Manager, troubleshooting 44 providing power 19 set default address 21 setting device address 20 setting device tag 20 setup and connection 14 setup and connection, live segment 15 H hard disk space requirement 10 I indicator light status 7 install Communication DTM 11 install Emerson DTM Library 12 install FDT Frame Application 33 install USB Fieldbus Interface Configuration utility 11 L launch the utility 17 Link Active Scheduler (LAS) 22 Link Master 22 live segment connection 15 O operating systems, supported 10 overview 5 P PACTware update device catalog 33 usage 34 parts and function 7 power indicator light status 7 power modes 9 Provide Power 19 R remove pre-release driver versions 51 User's Manual January 2019 52

set fieldbus device default address 21

setup and connection benchtop/segment connection 14 live segment connection 15 system requirements 10 T troubleshooting cannot edit device parameters, PACTware 47 fieldbus device not detected in utility 45 fieldbus device not responding in AMS Device Manager 44 U update device catalog 33 USB FF HSE Server starting, stopping 17 USB Fieldbus Interface Configuration utility installing 11 launching 17 starting/stopping HSE server manually 17 January 2019 User's Manual 53

AW7060MNL, rev. 3

January 2019 Emerson 12001 Technology Drive Eden Prairie, MN 55344 USA +1(952)828-3000 www.Emerson.com ©2019, Emerson The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are property of their respective owners.

Other Recording Equipment Manuals