CARLO GAVAZZI VariFlex3 RVLF Series Manual 

File Specifications

Brand: CARLO GAVAZZI
Category: Inverter Drive
Model: VariFlex3 RVLF Series (Manual ), prOiK1QaybMK.
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 245 pages

Download PDF

Download CARLO GAVAZZI VariFlex3 RVLF Series Manual (245 pages)

Read Online:

Read the CARLO GAVAZZI VariFlex3 RVLF Series Manual  online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Example 2. Set parameter 2: 12-00=[12345] to obtain the display format shown below.

Increment / Decrement key functions: MODE MODE 2sec later MODE MODE MODE MODE MODE Temperature < 4 > PIDfeedback < 5 > Output Current < 1 > Parameter DC voltage < 3 > Output Voltage < 2 > Set Frequency Display: Power supply Short time press Long time press T1 T2 “ PIDfeedback < 5 > Output Current < 1 > Parameter DC voltage < 3 > Output Voltage < 2 > Set Fr ...

Motor Controllers AC Variable Frequency Drives Type VariFlex3 RVLF

Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017 149 Register No. Content 2523H Frequency command(100/1Hz) 2524H Output frequency (100/1Hz) 2525H Output voltage command (10/1V) 2526H DC voltage command (1/1V) 2527H Output current (10/1A) 2528H Reserved 2529H Reserved 252AH PID feedback (100% / fmax , 10/1% ) 252BH PID input (100% / fmax, 10/1%) 252CH TM2 AVI input value (1000 / 10V) *1 252DH TM2 AC ...

Motor Controllers AC Variable Frequency Drives Type VariFlex3 RVLF

Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017 233 Supervision Data (Only for reading) Register Content 2520H 2521H Error content Bit Meaning 1 0 0 Operation State Run Stop 1 Direction State Reverse Forward 2 Inverter operation prepare state ready unready 3 Abnormal Abnormal normal 4 Data setting error Error No error 5~F (unused) Code Meaning Code Meaning 00 The inverter is normal 20 Over current ...

Motor Controllers AC Variable Frequency Drives Type VariFlex3 RVLF

Frequency upper limit Frequency Lower limit 0 Hz T 00-14 Acceleration time 1 Range [0.1~3600.0] s 00-15 Deceleration time 1 Range [0.1~3600.0] s 00-16 Acceleration time 2 Range [0.1~3600.0] s 00-17 Deceleration time 2 Range [0.1~3600.0] s Preset acceleration and deceleration times by above parameters are the time taken for the output frequency to ramp up or ramp down between the upper and the lower frequency limits. Actual acceleration and deceleration time is calculated as follows: (00-15)x(set frequency-the minimum starting f ...

CARLO GAVAZZI VariFlex3 RVLF Series user guide recommended for: B2 24V, RSWT Series, VariFlex2 RVDF Series, RG Series, Sx2WEB Series.

⚠️ Download Safety

The Inverter Drive Manual  (245 pages) is completely safe to download (last scan date: 08/01/2026).

Related PDF Instructions for CARLO GAVAZZI VariFlex3 RVLF Series:

Inverter Drive Equipment: Frequently Requested

Have some Questions about CARLO GAVAZZI VariFlex3 RVLF Series Device?

Get valuable and actionable advices from other CARLO GAVAZZI VariFlex3 RVLF Series device users. Describe your problem or question, regarding the using of VariFlex3 RVLF Series, in as much detail as possible, and other users will be able to answer you.