D-Link DES-3528 - xStack Switch - Stackable Hardware Installation Manual
Text of the manual
Hardware Installation Guide
Product Model: xStack® DES-3528/DES-3552 Series
Layer 2 Managed Stackable Fast Ethernet Switch
Release 2.61
Information in this document is subject to change without notice.
© 2010 D-Link Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of D-Link Corporation is strictly forbidden.
Trademarks used in this text: D-L ink and the D-LINK logo are trademarks of D-Link Corporation; Microsoft and Windows are registered trademarks
of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
D-Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own.
September 2010 P/N 651ES3500075G
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
ii
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasona ble protection against harmful interference when the equipment is operated in a commercial envir
onment. This
equipment generates, uses, and can radiate radio freq uency ene rgy and, if not installed and use d in accordance with this man ual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at their expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this produ ct may cause ra dio interference in which case the user ma y be required to take
adequate measures.
Warnung!
Dies ist ein Produkt der Klasse A. Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen. In diesem Fall kann vom Benutzer verlangt
werden, angemessene Massnahmen zu ergreifen.
Precaución!
Este es un producto de Clase A. En un entorno doméstico, puede causar interferencias de radio, en cuyo case, puede requerirse al usuario para
que adopte las medidas adecuadas.
Attention!
Ceci est un produit de classe A. Dans un environnement domestique, ce produit pourrait causer des interférences radio, auquel cas l`utilisateur
devrait prendre les mesures adéquates.
Attenzione!
Il presente prodotto appartiene alla classe A. Se utilizzato in ambiente domestico il prodotto può causare interferenze radio, nel cui caso è possibile
che l`utente debba assumere provvedimenti adeguati.
VCCI Warning
この装置は、クラスA 情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがあります。
この場合には使用者が適切な対策を講ずるよう要求されることがあります。
VCCI-A
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
iii
Table of Contents
Intended Readers ............................................................................................................................................................................ v
Typographical Conventions ............................................................................................................................................................................ v
Notes, Notices, and Cautions ......................................................................................................................................................... v
Safety Instructions ........................................................................................................................................................................ vi
Safety Cautions .............................................................................................................................................................................................. vi
General Precautions for Rack-Mountable Products ......................................................................................................................................vii
Protecting Against Electrostatic Discharge ................................................................................................................................................. viii
Introduction ...................................................................................................................................................... 1
Gigabit Ethernet Technology .......................................................................................................................................................................... 1
Switch Description .......................................................................................................................................................................................... 1
Features ........................................................................................................................................................................................................... 2
Ports ................................................................................................................................................................................................................ 3
Front-Panel Components ................................................................................................................................................................................. 4
LED Indicators ................................................................................................................................................................................................ 5
Rear Panel Description .................................................................................................................................................................................... 8
Side Panel Description .................................................................................................................................................................................... 9
Gigabit Combo Ports ..................................................................................................................................................................................... 10
Installation ...................................................................................................................................................... 11
Package Contents .......................................................................................................................................................................................... 11
Before You Connect to the Network ............................................................................................................................................................. 11
Installing the Switch without the Rack .......................................................................................................................................................... 12
Installing the Switch in a Rack ...................................................................................................................................................................... 12
Mounting the Switch in a Standard 19" Rack................................................................................................................................................ 13
Power On (AC Power) .................................................................................................................................................................................. 13
Power Failure (AC Power) ............................................................................................................................................................................ 13
Connecting DC Power to the DES-3528DC .................................................................................................................................................. 14
Connecting the Switch ................................................................................................................................... 15
Switch to End Node ...................................................................................................................................................................................... 15
Switch to Hub or Switch ............................................................................................................................................................................... 15
Connecting To Network Backbone or Server ................................................................................................................................................ 16
Introduction to Switch Management ........................................................................................................... 17
Management Options ................................................................................................................................................................... 17
Web-based Management Interface ................................................................................................................................................................ 17
SNMP-based Management ............................................................................................................................................................................ 17
Connecting the Console Port (RS-232 DCE) ................................................................................................................................................ 17
First Time Connecting to the Switch ............................................................................................................................................................. 19
Password Protection ...................................................................................................................................................................................... 19
SNMP Settings .............................................................................................................................................................................................. 20
IP Address Assignment ................................................................................................................................................................................. 21
Web-based Switch Configuration ................................................................................................................. 23
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
iv
Introduction .................................................................................................................................................................................. 23
Login to Web Manager ................................................................................................................................................................................. 23
Web-based User Interface ............................................................................................................................................................................. 24
Web Pages ..................................................................................................................................................................................................... 25
Technical Specifications ................................................................................................................................ 27
Cable Lengths ................................................................................................................................................. 34
Glossary .......................................................................................................................................................... 35
Warranties and Tech Support Information ................................................................................................ 38
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Intended Readers
The DES-3528/DES-3552 Switch Series Hardware Installation Guide contains i nformation fo r setup and
management of the Switch. This ma
nual is inten ded fo r network man agers familiar with network manag
ement
concepts and terminology.
Typographical Conventions
Convention Description
[ ]
In a comma nd line, square brackets indicate an optional ent ry. For example: [co py
filename] means that optionally you can type copy followed by the name of the file. Do not
type the brackets.
Bold font
Indicates a button, a toolbar icon, menu, or menu item. For example: Open the File menu
and choose Cancel. Used for emphasis. May also indicate system messages or prompts
appearing on your scre en. For examp le: Y ou have mail. Bold font is also
used to
represent filename s, pro gram nam es and co mmands. For example: use
the copy
command.
Boldface
Typewriter
Font
Indicates commands and responses to prom pts that must be typed exa ctly as pri nted in
the manual.
Initial capital letter
Indicates a wind ow nam e. Name s of keys on the keyboard have initial capitals. Fo
r
example: Click Enter.
Italics
Indicates a windo w name or a field. Also ca
n indicate a variables or para meter that is
replaced with an appropriate word or string. For example: type filename me ans that you
should type the actual filename instead of the word shown in italic.
Menu Name > Menu
Option
Menu Name > Menu Option Indicates the menu
structu re. Device > Port > Port
Properties means the Port Propertie s menu opti on under the Port menu option that is
located under the Device menu.
Notes, Notices, and Cautions
A NOTE indicates important information that helps you make better use of your device.
A NOTICE indicates either potential damage to hardware or loss of data and t ells you
how to avoid the problem.
A CAUTION indicates a potential for property damage, personal injury, or death.
v
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Safety Instructions
Use the following safety guidelines to ensure your own personal safety and to help protect your system from potential
damage. Throughout this document, the cauti on icon ( ) is used to indicate cautions and precautions that you need
to review and follow.
Safety Cautions
To redu ce t he risk of bodily injury, electri
cal shock, fire and
damage to the equipm
ent, observe the following
precautions.
•
Observe an d fo llow service mark ings. D o no t s ervice any p roduct ex cept as expl ained in your
system
documentation. Opening or removing covers that are marked with the triangular symbol with a lightning bolt
may expose you to electrical shock. Only a trained service technician should service components inside these
compartments.
•
If any of the following conditions occur, unplug the pr oduct from the electri cal outlet and re place the part o r
contact your trained service provider:
The power cable, extension cable, or plug is damaged.
An object has fallen into the product.
The product has been exposed to water.
The product has been dropped or damaged.
The product does not operate correctly when you follow the operating instructions.
•
Keep your system away from radiators and heat sources. Also, do not block cooling vents.
•
Do not spill food or liqui ds on your system components, and never operate the product in a wet enviro nment.
If the system gets wet, see the appro
priate se ction in your trouble shooting guide or co ntact your trained
service provider.
•
Do n ot pu sh any obje cts into the op enings of your system. Doing so can cause fi re or electri c sho ck by
shorting out interior components.
•
Use the product only with approved equipment.
•
Allow the product to cool before removing covers or touching internal components.
•
Operate the product only from the type of external power source indicated on the electrical ratings label. If you
are not sure of the type of power source required, consult your service provider or local power company.
•
To help avoi d damaging your system, be su re the voltage on th e power supply is set to match the p ower
available at your location:
115 volts (V)/60 hertz (Hz) in most of North and South America and some Far Eastern countries
100 V/50 Hz in eastern Japan and 100 V/60 Hz in western Japan
230 V/50 Hz in most of Europe, the Middle East, and the Far East
48VDC for DES-3528DC
•
Also, be sure that attached devices are electrically rated to operate with the power available in your location.
•
Use only a pproved power cable(s). If you have not been provided with a power cable for y our system or for
any AC-powered option intende d for yo ur system, purcha se a power cable that is approve d for use in your
country. The power cable must be rated for the
product and for the voltage and current
marke d on the
product's electrical ratings label. The voltage and current rating of the cable should be greater than the ratings
marked on the product.
vi
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
•
To help prevent electric shock, plug the system and peripheral power cables into properly grounded electrical
outlets. These cable s are equipped wi th three-p rong pl ugs to help ensu re p roper gro unding. Do not use
adapter plugs or remove the grou nding prong from a cable. If you must use an extension cable, use a 3-wire
cable with properly grounded plugs.
•
Observe extensi on ca ble and powe r strip ratin gs. Make sure that the total
ampere ratin g of all product s
plugged into the extension cable or power strip does not exceed 80 percent of the ampere ratings limit for the
extension cable or power strip.
•
To help protect your system from sudden, transient increases and decreases in electrical power, use a surge
suppressor, line conditioner, or uninterruptible power supply (UPS).
•
Position system cables and power cables carefully; route cables so that they cannot be stepped on or tripped
over. Be sure that nothing rests on any cables.
•
Do n ot modi fy power cables or pl ugs. Co nsult a licensed el ectrician or your po wer company for site
modifications. Always follow your local/national wiring rules.
•
When con necting or di sconnecting po wer to hot-pl uggable po wer su pplies, if offered with your syste
m,
observe the following guidelines:
Install the power supply before connecting the power cable to the power supply.
Unplug the power cable before removing the power supply.
If the system has multiple sources of power, disconnect power from the system by unplugging all power
cables from the power supplies.
•
Move products with care; ensure that all caste rs and/or stabilizers are firmly connected to the system. Avoid
sudden stops and uneven surfaces.
General Precautions for Rack-Mountable Products
Observe the following preca utions for rack stabilit y and safe ty. Also, refer to the rack installation do
cumentation
accompanying the system and the rack for specific caution statements and procedures.
•
Systems are considered to be components in a rack. Thus, "component" refers to any sy stem as well as to
various peripherals or supporting hardware.
•
Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and
that the full weight of the rack re sts on the floor. In stall front a nd side sta bilizers on a si ngle rack or front
stabilizers for joined multiple racks before working on the rack.
•
Always load the rack from the bottom up, and load the heaviest item in the rack first.
•
Make sure that the rack is level and stable before extending a component from the rack.
•
Use caution when pressing the component rail release latches and sliding a component into or out of a rack;
the slide rails can pinch your fingers.
•
After a component is inserted into the rack, ca refully extend the rail into a lo cking position, and then slide the
component into the rack.
•
Do not overload the AC su pply branch circuit that provides power to the rack. The total rack load should not
exceed 80 percent of the branch circuit rating.
•
Ensure that proper airflow is provided to components in the rack.
•
Do not step on or stand on any component when servicing other components in a rack.
vii
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
NOTE: A qualified electrician must perform all connections to DC power and to safety grounds.
All electrical wiring must comply with applicable local, regional or national codes and practices.
CAUTION: Never defeat t he ground conductor or operate the equipment in the ab sence of a
suitably installed ground conductor. Contact the appropriate electrical inspection authority or an
electrician if you are uncertain that suitable grounding is available.
CAUTION: The system chassis must be positively gr ounded to th e rack cabin et frame. Do not
attempt to conne ct powe r to the system until
grounding cabl es are connected. A qualified
electrical inspector must inspect completed power and safety ground wiring. An energy hazard
will exist if the safety ground cable is omitted or disconnected.
Protecting Against Electrostatic Discharge
Static electri city can h arm delicate compon ents i nside y our system. To prevent static damag e, discharge stati c
electricity from your body before you touch any of the electronic components, such as the microprocessor. You can do
so by periodically touching an unpainted metal surface on the chassis.
You can also take the following steps to prevent damage from electrostatic discharge (ESD):
1. When unpacking a static-sensitive component from its shipping carton, do not remove t he component from
the antistati c packin g ma terial until yo u are ready to install t he comp onent in y our system. Ju st bef ore
unwrapping the antistatic packaging, be sure to discharge static electricity from your body.
2. When transporting a sensitive component, first place it in an antistatic container or packaging.
3. Handle all se nsitive components in a static-safe are a. If possible, use anti static floor pa ds, workbench pads
and an antistatic grounding strap.
viii
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Section 1
Introduction
Gigabit Ethernet Technology
Switch Description
Features
Ports
Front-Panel Components
LED Indicators
Rear Panel Description
Side Panel Description
Gigabit Combo Ports
The DES-35 28/DES-3552 Series a re l ayer 2 Fa st Et hernet swit ches an d me mbers of the D-Lin k xStack ® family.
Ranging from 10/100Mbps edge switches to core gi gabit switches, the xStack ® switch family has be en future-proof
designed to provide a stacking architecture with fault tolera nce, flexibility, port density, robust security and maximum
throughput with a user-friendly management interface for the networking professional.
The following manual de scribes the in stallation, maintenance and configurations concerning the xStack ® DES-3528,
DES-3528DC, DES-3528P, DES-3552 and DES-3552P switches. Please take note that if this device was purchased
outside of Europ e, certai n cosmetic d ifferences b etween the a ctual switch a nd image s in this docum ent will be
apparent to the rea der, such as the faceplate and th e manual cover. The DE S-3528/DES-3552 Series has already
joined the xStack ® family for the Eu ropean market and is soon to be xStack ® converted, universally. Changes are
made to the appearance of the device only and no configuration or internal hardware alterations occur.
NOTE: For t he re mainder of this man ual, all versi ons of the DES-3528, DES-3528P, DE S-
3528DC, DES-3552 and DES-3552P switches will be referred to as simply the Switch or the
DES-3528.
Gigabit Ethernet Technology
Gigabit Ethernet is an extension of IEEE 802.3 Ethernet utilizing the same packet structure, format, and support for full
duplex, flow control, and manag ement objects, but with a t enfold increase in theoretical throu ghput over 100Mb ps
Fast Ethernet and a one hundred-fold increase over 10Mbps Ethernet. Since it is compati ble with all 10Mbp s and
100Mbps Ethernet enviro nments, Gigabit Ethernet provides a strai ghtforward upgrade without wasting a com pany's
existing investment in hardware, software, and trained personnel.
The in creased sp eed and extra ba ndwidth offe red by Gigabi t Ethernet a re essential to copi ng with the net work
bottlenecks that frequently develop as computers and their busses get faster and more users using applications that
generate more traffic. Upgrading key components, such as your backbone and servers to Gigabit Ethernet can greatly
improve network response times as well as significantly speed up the traffic between your sub networks.
Gigabit Ethernet enabl es fast optical fi ber connections to sup port video co nferencing, complex imaging, and simi lar
data-intensive applications. Likewise, since data transfers occur 10 times fa ster than Fast Ethernet, servers o utfitted
with Gigabit Ethernet NIC's are able to perform 10 times the number of operations in the same amount of time.
In addition, the pheno menal band width delivered by Gigabit Et hernet is the most cost
-effective method to take
advantage of today and tomorrow's rapidly improving switching and routing internetworking technologies.
Switch Description
The DES-35 28/DES-3552 Switch Seri es is e quipped with unshielded twist ed-pair (UTP ) ca ble po rts providin g
dedicated 10 or 100 Mbps bandwidth. The Switch has 24/48 UTP ports and Auto MDI-X/MDI-II convertible ports that
can be used for uplinking to another switch. These ports can be used for conne cting PCs, printers, servers, hub s,
1
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
2
routers, switches and other networking devices. The dual speed ports use standard twisted-pair cabling and are ideal
for segmenting networks into small, connected sub networks for superior performance. Each 10/100 port can support
up to 200 Mbps of throughput in full-duplex mode.
In addition, the Switch has 2 SFP combo ports. These two-gigabit combo ports are ideal for connecting to a server or
network backbone. This stackable Switch enables the network to use some of the mo st demanding multimedia and
imaging a pplications concurrently with other user
applications without creat ing bottlene cks. The b uilt-in co nsole
interface can be used to configure the Switch's settings for prio rity queuing, VLANs, and port trun k group s, port
monitoring, and port speed.
Features
•
IEEE 802.3 10BASE-T compliant
•
IEEE 802.3u 100BASE-TX compliant
•
IEEE 802.1p Priority Queues
•
IEEE 802.3x flow control in full duplex mode
•
IEEE 802.3ad Link Aggregation Control Protocol
support.
•
IEEE 802.1X Port-based and MAC-based Access
Control
•
IEEE 802.1Q VLAN
•
IEEE 802.1D Spanning Tree, IEEE 802.1W Rapid
Spanning Tree and IEEE 802.1s Multiple Spanning
Tree support
•
Access Control List (ACL) support
•
Single IP Management support
•
Access Authentication Control utilizing TACACS,
XTACACS and TACACS+
•
Dual Image Firmware
•
Simple Network Time Protocol support
•
MAC Notification support
•
Asymmetric VLAN support
•
System and Port Utilization support
•
System Log Support
•
Support port-based enable and disable
•
Address table: Supports up to 16K MAC addresses
per device
•
Supports a packet buffer of up to 1 Mbyte
•
Supports Port-based VLAN Groups
•
Port Trunking with flexible load distribution and fail-
over function
•
IGMP Snooping support
• SNMP
support
•
Secure Sockets Layer (SSL) and Secure Shell
(SSH) support
• Port
Mirroring support
•
MIB support for:
•
RFC1213 MIB II
• RFC14
93 Bridge
•
RFC1907 SNMPv2 MIB
•
RFC1757, 2819 RMON
• RFC20
21 RMONv2
•
RFC1643, 2358, 2665 Ether-like MIB
•
RFC2233, 2863 Interface MIB
• Private
MIB
•
RFC2674 for 802.1p
•
RFC2618 RADIUS Authentication Client
•
RFC2620 RADIUS Accounting Client
•
RFC2925 Ping & Traceroute
• IEEE
802.1X MIB
•
RS-232 DCE console port for Switch management
•
Provides parallel LED display for port status such as
link/act, speed, etc.
•
High performance switching engine performs forwarding and filtering at full wire speed, maximum 14, 881 packets/sec on
each 10Mbps Ethernet port, and maximum 148,810 packet/sec on 100Mbps Fast Ethernet port.
•
Full- and half-duplex for both 10Mbps and 100Mbps connections. Full duplex allows the switch port to simultaneously
transmit and receive data. It only works with connections to full-duplex-capable end stations and switches. Connections to a
hub must take place at half-duplex
•
Support broadcast storm filteringF
•
Non-blocking store and forward switching scheme capability to support rate adaptation and protocol conversion
•
Supports by-port Egress/Ingress rate control.
•
Supports IP-MAC Port Binding.
•
Efficient self-learning and address recognition mechanism enables forwarding rate at wire speed
•
Supports STP Loopback Detection
•
Safeguard Engine Support
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Ports
The following table lists the relative ports that are present within each switch:
Device Features
DES-3528
DES-3528DC
DES-3528P
DES-3552
DES-3552P
10/100BASE-T Ports
24 Ports
24 Ports
24 Ports
48 Ports
48 Ports
PoE Function Alternative A
N/A
N/A
24 Ports
N/A
48 Ports
1000Base-T/SFP Combo
Ports
2 Ports
2 Ports
2 Ports
2 Ports
2 Ports
1000Base-T Ports
2 Ports
2 Ports
2 Ports
2 Ports
2 Ports
DCE RS-232 DB-9 Console
Port
One Female
One Female
One Female
One Female
One Female
The follo wing table list s the feature s and compatibility for each type of
port presen t in the DES-352
8/DES-
3528DC/DES-3528P/DES-3552/DES-3552P.
10/100 BASE-T
SFP
1000BASE-T
IEEE 802.3 compliant
IEEE 802.3u compliant
IEEE 802.3x flow control support in
full-duplex
IEEE 802.3af compliant (DES-
3528P/DES-3552P only)
Auto MDI-X/MDI-II c
ross over
support
SFP Transceivers Supported:
DEM-310GT (1000BASE-LX)
DEM-311GT (1000BASE-SX)
DEM-314GT (1000BASE-LHX)
DEM-315GT (1000BASE-ZX)
DEM-312GT2 (1000BASE-SX)
DEM-210 (Single Mode 100BASE-
FX)
DEM-211 (Multi Mode 100BASE-
FX)
WDM Transceiver Supported:
DEM-330T (TX-1550/RX-1310nm),
up to 10km,Single-Mode
DEM-330R (TX-1310/RX-1550nm),
up to 10km,Single-Mode
DEM-331T (TX-1550/RX-1310nm),
up to 40km, Single-Mode
DEM-331R (TX-1310/RX-1550nm),
up to 40km, Single-Mode
Compliant to the following
standards:
1. IEEE 802.3z compliance
2. IEEE 802.3u compliance
IEEE 802.3 compliant
IEEE 802.3u compliant
IEEE 802.3ab compliant
IEEE 802.3z compliant
IEEE 802.3x flow control support i n
full-duplex
NOTE: The SFP comb o ports on th e Switch cannot be used simultaneously with the
corresponding 1000BASE-T ports. If both ports are in use at the same time (ex . port 25
of the SFP and port 2 5 of the 1000BA SE-T), the SFP ports will take pri ority over the
combo ports and render the 1000BASE-T ports inoperable.
3
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
NOTE: For customers interested in D-View, D-Link Corporation's proprietary SNMP
management software, go to the D-Link Website (www.dlink.com) and download the
software and manual.
Front-Panel Components
DES-3528
•
Twenty-four 10/100Mbps BASE-T ports
•
Two Combo 1000BASE-T/SFP ports located to the right
•
Two 1000BASE-T ports located to the rear
•
One female DCE RS-232 DB-9 console port
•
LEDs for Power, Console, RPS, Master, Link/Act/Speed for each port
Figure 1- 1. Front Panel View of the DES-3528 switch
DES-3528P
•
Twenty-four 10/100Mbps BASE-T ports
•
Two Combo 1000BASE-T/SFP ports located to the right
•
Two 1000BASE-T ports located to the rear
•
One female DCE RS -232 DB-9 console port
•
One PoE Select Button
•
LEDs for Power, Console, RPS, MS, Link, PoE, Link/Act/Speed for each port
Figure 1- 2. Front Panel View of the DES-3528P switch
DES-3528DC
•
Twenty-four 10/100Mbps BASE-T ports
•
Two Combo 1000BASE-T/SFP ports located to the right
•
Two 1000BASE-T ports located to the rear
•
One female DCE RS-232 DB-9 console port
•
LEDs for Power, Console, Master, Link/Act/Speed for each port
Figure 1- 3. Front Panel View of the DES-3528DC switch
DES-3552
•
Forty-eight 10/100Mbps BASE-T ports
•
Two Combo 1000BASE-T/SFP ports located to the right
4
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
•
Two 1000BASE-T ports located to the rear
•
One female DCE RS -232 DB-9 console port
•
LEDs for Power, Console, RPS, Master, Link/Act/Speed for each port
Figure 1- 4. Front Panel View of the DES-3552 switch
DES-3552P
•
Forty-eight 10/100Mbps BASE-T ports
•
Two Combo 1000BASE-T/SFP ports located to the right
•
Two 1000BASE-T ports located to the rear
•
One female DCE RS -232 DB-9 console port
•
One PoE Select Button
•
LEDs for Power, Console, RPS, MS, Link, PoE, Link/Act/Speed for each port
Figure 1- 5. Front Panel View of the DES-3552P switch
LED Indicators
The Switch suppo rts LED indicators for Power, Con sole, RPS, Master (on DE S-3528P and DES-3552P, this LED is
for MS) and Port LEDs. The following shows the LED indicators for the DES-3528/DES-3552 switch series along with
an explanation of each indicator. LEDs and their corresponding meanings are displayed below.
Figure 1- 6. LED Indicators on DES-3528 switch
Figure 1- 7. LED Indicators on DES-3552 switch
Figure 1- 8. LED Indicators on DES-3528DC switch
5
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Figure 1- 9. LED Indicators on DES-3528P switch
Figure 1- 10. LED Indicators on DES-3552P switch
LED indicators for DES-3528/DES-3528DC/DES-3552/DES-3528P/DES-3552P
Location
LED Indicative
Color
Status
Description
Per Device
Power
Green
Solid Light
Power On
Light off
Power Off
Console
Green
Solid Light
Console on
Blinking
POST is in progress.
Light off
Console off
RPS
(Not
for
DES-3528DC)
Green
Solid Light
RPS is in Use
Light Off
RPS Off
Master(MS)
Green
Solid Light
When the device is the stacking
master.
Light off
Not the Stacking Master.
Stacking ID
Green
Capable 1-8
The Box ID is assigned either by the
user (static mode) or by the system
(automatic mode). When the box
becomes a primary master the 7
segments work bi-functionally. The box
ID and “H” indicate the primary Master
and the display on other switches will
be shown in turn. That is boxID- > H ->
boxID -> H…
Mode Select Button
(DES-3528P and
DES-3552P only)
Link/Act/Speed
Green
Solid Light
Link/Act/Speed Mode
PoE
Green
Solid Light
PoE Mode
LED Per 10/100 Mbps Port Link/Act/Speed
Green/Amber
Solid Green
When there i s a secure 1 00Mbps Fast
Ethernet con nection (or link) at any of
the ports.
Blinking Green
When there is reception or transmission
(i.e. Activity—Act) of data occurring at a
Fast Ethernet connected port.
6
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Solid Amber
When th ere is a secure 10Mbps
Ethernet con nection (or link) at any of
the ports.
Blinking Amber
When there is reception or transmission
(i.e. Ac tivity—Act) of data occu rring at
an Ethernet connected port.
Light off
No link
PoE (DES-3528P
and DES-3552P
only)
Green
Solid Green
Power device is connected.
Blinking
Port has detected an error condition.
Light off
Power device may receiv e power from
an AC p
ower source or no
802.3af/802.3at PD is found.
LED Per GE Port
Link/Act/Speed
Green/Amber
Solid Green
When there is a secure 1000Mb
ps
connection (or link) at any of the ports.
Blinking Green
When there is reception or transmission
(i.e. Activity--Act) of data occurring at a
1000Mbps connected port.
Solid Amber
When there is a se cure 10/100M bps
Fast Ethern et conne ction (or link) at
any of the ports.
Blinking Amber
When there is reception or transmission
(i.e. Activity—Act) of data occurring at a
10/100Mbps Fast Etherne t conn ected
port.
Light off
No link
LED per SFP Port
Link/Act/Speed
Green/Amber
Solid Green
When there is a secure 1000Mb
ps
connection (or link) at the ports.
Blinking Green
When there is reception or transmission
(i.e. Activity--Act) of data occurring at a
1000Mbps connected port.
Solid Amber
When there is a se
cure 100 Mbps
connection (or link) at any of the ports.
Blinking Amber
When there is reception or transmission
(i.e. Activity—Act) of data occurring at a
100Mbs connected ports.
Light off
No link
7
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Rear Panel Description
The DES-3528 rear panel contains ports 27 a nd 28, (1000BASE-T), an AC power connector, and an outlet for an
optional external RPS.
Figure 1- 11. Rear panel view of the DES-3528
The DES-3528P rear panel c ontains ports 27 and 28, (1000BASE-T), an A C power connector, and an outlet for an
optional external RPS.
Figure 1- 12. Rear panel view of the DES-3528P
The DES-3552 rear panel contains ports 51 and 52, (100 0BASE-T), RS-232 DCE Diagnostic port (console port ), an
AC power connector, and an outlet for an optional external RPS.
Figure 1- 13. Rear panel view of the DES-3552
The DES-3528P rear panel contains ports 51 and 52, (1000BASE-T), RS-232 DCE Diagnostic port (console port), an
AC power connector, and an outlet for an optional external RPS.
Figure 1- 14. Rear panel view of the DES-3552P
The AC p ower connector is a stan dard three-pronged connector that su pports the p ower cord. Plug -in the femal e
connector of the provide d power cord i nto this socket, and the male side of the cord into a power outlet. The Switch
automatically adjusts its power setting to any supply voltage in the range from 100 ~ 240 VAC at 50 ~ 60 Hz.
The rear panel also includes an outlet for an optional external power supply. When power fails, the optional external
RPS will take over all the power immediately and automatically.
The rear panel of the
DES-3528DC includes po rts 27 and
28, (1000BASE-T) , and an openi
ng desi gned to
accommodate the DC power wiring assembly. See the installation instructions in Section 2 for details.
Figure 1- 15. Rear panel view of the DES-3528DC
8
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Side Panel Description
The left and right-hand panel of the DE S-3528 and DES-3528DC Switches contain a he at vent. The he at vents a re
used to dissipate heat. Do not block these openings, and leave at least 6 inches of space at the rear and sides of the
Switch for proper ventilation. Be reminded that without proper heat dissipation and air circulation, system components
might overheat, which could lead to system failure.
Figure 1- 16. Side panels of the DES-3528/DES-3528DC
The right-hand side panel of the DES-3552 and DES-3528P Switches contain two system fans and ventilation along
the entire rig ht side. The left hand pan el includes a heat ven t. The system fa ns are use d to dissi pate heat. Do not
block these openings on either side of the Switch. Leave at least 6 inches of space at the rear and sides of the Switch
for proper ventilation. Be reminde d that without proper heat dissipation and air circulation, system components might
overheat, which could lead to system failure.
Figure 1- 17. Side panels of the DES-3552/DES-3528P
The right-hand side panel of the DES-3552P Switch contains three system fans and ventilation along the entire right
side. The left hand panel
includes a heat vent. Th e system fans are u sed to dissi pate h eat. Do not block these
openings on either side of the Switch. Leave at least 6 inches of spa ce at the rear and sides of the Switch for prope r
ventilation. Be reminded that without proper heat dissipation and air circulation, system components might overheat,
which could lead to system failure.
Figure 1- 18. Side panels of the DES-3552P
9
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Gigabit Combo Ports
In addition to the 24/48 10/100 Mbp s ports, the Switch feat ures two Giga bit Ethernet Combo ports. The se two port s
are 1000BASE-T copper ports (provided) and SFP ports (optional). See the di agram below to view the t wo SFP port
modules bei ng plug ged i nto the Switch. Please n
ote that although the se t wo front pa nel module s can be u sed
simultaneously. At the same time, only one copper port or one SFP port can link up for each
combo po rt. The SFP
port will always have the highest priority.
Figure 1- 19. Inserting the SFP modules into the DES-3528/DES-3528P/DES-3528DC/DES-3552/DES-3552P
Figure 1-20. Installing the SFP Module
10
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Section 2
Installation
Package Contents
Before You Connect to the Network
Installing the Switch without the Rack
Installing the Switch in a Rack
Mounting the Switch in a Standard 19" Rack
Power On (AC Power)
Power Failure (AC Power)
Connecting DC Power to the DES-3528DC
Package Contents
Open the shi pping carton of the Switch and carefull y unpack its contents. The carton should contain the following
items:
• One
xStack® stand-alone switch
•
One AC power cord*
• Regi
stration card
•
Mounting kit (two brackets and screws)
•
Four rubber feet with adhesive backing
•
RS-232 console cable
If any item is found missing or damaged, please contact your local D-Link Reseller for replacement.
* Please Note the DES-3528DC Switch does not require an AC power cord therefore none is provided.
Before You Connect to the Network
The site where you install the Switch may greatly affect its performance. Please follow these guidelines for setting up
the Switch.
•
Install the Switch o n a sturdy, level surface that c
an su pport at least 6.6 lbs (3 kg) of
weight for DES-
3528/DES-3528DC, at lea st 13.2 lb s (6 kg) of weigh t for DES-3552/DES-3528P, at least 1 5.4 lbs (7 kg) of
weight for DES-3552P. Do not place heavy objects on the Switch.
•
The power outlet should be within 1.82 meters (6 feet) of the Switch.
•
Visually inspect the power cord and see that it is fully secured to the AC power port.
•
Make sure that there is proper he at dissipation from and adequat e ventilation arou nd the Switch. Leave at
least 10 cm (4 inches) of space at the front and rear of the Switch for ventilation.
•
Install the Switch in a fairly cool and dry place for the acceptable temperature and humidity operating ranges.
•
Install the Switch in a site free from st rong electromagnetic field generators (such as motors), vibration, dust,
and direct exposure to sunlight.
•
When installing the Switch on a level surfa ce, attach the rubber feet to the bottom of the d evice. The rubber
feet cushions help protect the casing from scratches and prevent it from scratching other surfaces.
11
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Installing the Switch without the Rack
When installing the Switch on a deskt op or shelf, the rubb er feet included with the Switch shoul d first be attached.
Attach these cushioning feet on the bottom at each corner of the device. Allow enough ventilation space between the
Switch and any other objects in the vicinity.
Figure 2- 1. Preparing the Switch for installation on a desktop or shelf
Installing the Switch in a Rack
The Switch can be mounted in a standard 19" rack. Use the following diagrams to guide you.
Figure 2- 2. Fasten mounting brackets to the Switch
Fasten the mounting brackets to the Switch using the screws provided. With the brackets attached securely, you ca n
mount the Switch in a standard rack as shown in Figure 2-3 below.
12
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Mounting the Switch in a Standard 19" Rack
CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the
rack to tip over, potentiall y resultin g in bodily in jury unde r certai n circu mstances. The refore, alway s
install the stabilizers before insta lling components in the ra ck. After installing components in a rack, do
not pull mo re than one component out of the ra ck on its slide assemblies at one time. The weight of
more than one extended component could cause the rack to tip over and may result in injury.
Figure 2- 3. Installing the Switch in a rack
Power On (AC Power)
Plug one end of the AC p ower cord into the powe r connector of the Switch a nd the other end into the local po wer
source outlet.
After the Switch is powered
on, the LED indicators will momentarily blin
k. This blinking of
the LED indicators
represents a reset of the system.
Power Failure (AC Power)
As a precaution for A C p ower supply units, in th e event of a powe r failure, unplu g the Switch. Wh en power ha s
resumed, plug the Switch back in.
13
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Connecting DC Power to the DES-3528DC
Follow the instructions below to connect the DC power supply of the DES-3528DC to the DC power source.
Figure 2- 4. Power connections attached to contacts after assembly
1. The DC power supply has a three-terminal wiring block consisting of a positive (+), a negative (-), and a safety
ground terminal.
2. Firmly attach the DC power to the negative and positive contacts on the wiring assembly.
•
The negative pole (-) connects to the -48V contact.
•
The positive pole (+) connects to the -48V Return contact.
•
If available, an earth ground may be connected to the center contact post.
3. Tighten the contact screws to secure the connection.
NOTE: Use a minimum 18-gauge (AWG) wire.
All powe r co nnection wi ring sh ould conform to the rules a nd regulatio ns in the
National Electrical Code (NEC), as well as any local codes.
A branch circuit over current protection must be rated between 2A and 10A.
CAUTION: This equipment must be grounded.
CAUTION: This equipment must be installed and maintained by qualified service
personnel only.
14
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Section 3
Connecting the Switch
Switch to End Node
Switch to Hub or Switch
Connecting To Network Backbone or Server
NOTE: All 24/48 high-performance NWay Ethernet ports can support both
MDI-II and MDI-X connections.
Switch to End Node
End nodes include PCs outfitted with a 10, 100 or 1000 Mbps RJ-45 Ethernet/Fast Ethernet Network Interface Ca rd
(NIC) and most routers.
An end no de can be connected to the Switch via a twisted-pair Category 3, 4, or 5 UTP/ STP cable. T he end n ode
should be connected to any of the ports of the Switch.
Figure 3- 1. The Switch connected to an end node
The Link/Act LEDs for each UTP port will light green or amber when the link is valid. A blinking LED indicates packet
activity on that port.
Switch to Hub or Switch
These connections can be accomplished in a number of ways using a normal cable.
A 10BASE-T hub or switch can be connected to the Switch via a twisted-pair Category 3, 4 or 5 UTP/STP cable.
A 100BASE-TX hub or switch can be connected to the Switch via a twisted -pair Category 5 UTP/STP cable.
A 1000BASE-T hub or switch can be connected to the Switch via a twisted -pair Category 5E UTP/STP cable.
15
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Figure 3- 2. The Switch connected to a normal (non-Uplink) port on a hub or switch using a straight or
crossover cable
Connecting To Network Backbone or Server
The two SFP combo ports are ideal for linking to a network backbone or server. The copper ports operate at a speed
of 1000, 100 or 10Mbps in full or half duplex mode. The fiber optic ports can operate at 100Mbps or 1000Mbps in full
duplex mode.
Connections to the Gigabit Ethernet ports are made using fiber optic cable or Category 5E copper cable, depending
on the type of port. A valid connection is indicated when the Link LED is lit.
Figure 3- 3. Connecting the Switch to a Server
16
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Section 4
Introduction to Switch Management
Management Options
Web-based Management Interface
SNMP-Based Management
Connecting the Console Port (RS-232 DCE)
First Time Connecting to the Switch
Password Protection
SNMP Settings
IP Address Assignment
Management Options
This system may be man aged out-of-band through the con sole port on the fro nt panel o r in-band using Telnet. The
user may also choose the web-based management, accessible through a web browser.
Web-based Management Interface
After you have su ccessfully installed the Switch, yo u can configure the Swit ch, monitor th e LED pa nel, and display
statistics graphically using a Web browser, such as Mozilla Firefox or Microsoft® Inter net Explorer (v ersion 6.0 or
later).
SNMP-based Management
You can manage the S witch with an SNMP-compatible console program. The Switch su pports SNMP version 1.0,
version 2.0 and version 3.0. The SNMP agent decodes the incoming SNMP messages and responds to requests with
MIB objects stored in the database. The SNMP agent updates the MIB objects to generate statistics and counters.
Connecting the Console Port (RS-232 DCE)
The Switch p rovides an RS-232 serial port that enables a co nnection to a computer or terminal for monitoring an
d
configuring the Switch. This port is a female DB-9
connector, impleme nted as a data co mmunications equipm ent
(DCE) connection.
To use the console port, you need the following equipment:
A terminal or a computer with both a serial port and the ability to emulate a terminal.
A null modem or Parallel RS-232 cable with a male DB-9 connector for the console port on the Switch.
To connect a terminal to the console port:
1. Connect the male conne ctor of the RS -232 cable di rectly to the console po rt on the Switch, and tighten t he
captive retaining screws.
2. Connect the other e nd of the cabl e to a terminal o r to the serial connector of a comp uter running terminal
emulation software. Set the terminal emulation software as follows:
3. Select the appropriate serial port (COM port 1 or COM port 2).
4. Set the data rate to 115200 baud.
5. Set the data format to 8 data bits, 1 stop bit, and no parity.
6. Set flow control to none.
7. Und er Properties, select VT100 for Emulation mode.
17
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
8. Select
Terminal keys f or Function, Arrow, an d Ctrl key s. Ensu re that you sele
ct Te rminal keys (not
Windows keys).
NOTE: When you use HyperTerminal with the Microsoft® Windo ws® 2000 operating sys-
tem, ensure that you have Windo ws 2000 Service Pack 2 or later installed. Wi ndows 2000
Service Pa ck 2 allows yo u to use arro w keys in HyperTerminal's VT100 em ulation. See
www.microsoft.com for information on Windows 2000 service packs.
9. After you have correctly set up the terminal, plug the power cable into the power receptacle on the back of the
Switch. The boot sequence appears in the terminal.
10. After the boot sequence completes, the console login screen displays.
11. If you have not logged into the command line interface (CLI) program, press the Enter key at the User n ame
and password prompts. There is no default user name and password for the Switch. The administrator must
first create user na mes and password s. If you have previou sly set up use r accounts, log in and contin ue to
configure the Switch.
12. Enter the commands to complete you r desi red ta sks. Many commands requi re admini strator-level a ccess
privileges. Read the n
ext section f
or mo re inf ormation on setting up
use r acco unts. See t
he
DES-3528/DES-3552 Switch Series CLI Reference Guide on the do cumentation CD for a li
st of all
commands and additional information on using the CLI.
13. When you h ave co mpleted you r tasks, exit the session
with t he log out co mmand or close th e em ulator
program.
14. Make sure the terminal or PC you are using to make this connection is configured to match these settings.
If you are having proble ms making this conne ction on a PC, ma ke sure the e mulation is set to VT-100. You will be
able to set the emulation by clicking o n the File menu in you HyperTerminal window, clicking on Properties in the
drop-down menu, and then clicking the Settings tab. This is where you will find the Emulation options. If you still d o
not see anything, try rebooting the Switch by disconnecting its power supply.
Once connected to the console, the screen below will appear on your console screen. This is where the user will enter
commands to perform all the available management functions. The Switch will prompt the user to ente r a user name
and a password. Upon the initial connection, there is no user name or password and therefore just press “enter” twice
to access the command line interface.
DES-3528 Fast Ethernet Switch
Command Line Interface
Firmware: Build 2.60.017
Copyright(C) 2010 D-Link Corporation. All rights reserved.
Username:
Figure 4- 1. Initial screen after first connection
18
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
First Time Connecting to the Switch
The Switch supports user-based security that can allow you to pre vent unauthorized users from accessing the Switch
or changing its settings. This section tells how to log onto the Switch.
NOTE: The passwords used to access the Switch are case-sensitive; therefore, "S" is
not the same as "s."
When you first connect to the Switch, you will be presented with the first login screen.
NOTE: Press Ctrl+R to ref resh the scre en. This command can be used at a ny time to
force the console program in the Switch to refresh the console screen.
Press Enter in both the
Use rname and Pa ssword fields. Yo u will be gi
ven acce ss to the com mand p rompt
DES-3528:admin# shown below:
There is no initial username or password. Leave the Username and Password fields blank.
DES-3528 Fast Ethernet Switch
Command Line Interface
Firmware: Build 2.60.017
Copyright(C) 2010 D-Link Corporation. All rights reserved.
Username:
PassWord:
DES-3528:admin#
Figure 4- 2. Command Prompt
NOTE: The first user automatically gets Administrator level privileges. It is recommended to
create at least one Admin-level user account for the Switch.
Password Protection
The Switch does not have a default user name and password. One of the first tasks when settings up the Switch is to
create user accounts. Once logge d in using a pred efined administrator-level user name, users will have privileged
access to the Switch's management software.
After your initial login, define new pa
sswords for both def ault user na mes to prevent un authorized access to the
Switch, and record the passwords for future reference.
To create an administrator-level account for the Switch, follow these steps:
At the CLI login prompt, enter create account admin followed by the and press the Enter key.
The Switch will then prompt the user for a password. Type the used for the adm inistrator account being
created and press the Enter key.
Again, the user will be prompted to enter the same password again to verify it. Type the same password and press the
Enter key.
Successful creation of the new administrator account will be verified by a Success message.
19
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
NOTE: Passwords are ca se sensitive. User names and passwo rds can be
up to 15 characters in length.
The sample belo w illu strates a successful creati on of a
new admi nistrator-level account with th e user n ame
"newmanager".
DES-3528:admin# create account admin newmanager
Command: create account admin newmanager
Enter a case-sensitive new password: ********
Enter the new password again for confirmation: ********
Success.
DES-3528:admin#
Figure 4- 3. New administrator level account
NOTICE: CLI configuration commands only modify the running configuration file
and are not saved when t he Switch is rebooted. To save all your configuration
changes in n onvolatile storage, you m ust use th e save command to copy the
running configuration file to the startup configuration.
SNMP Settings
Simple Net work Management Proto col (SNMP ) is an OS
I La yer 7 (Appli cation Laye r) designed sp ecifically for
managing an d monitorin g network dev ices. SNMP enabl es net work ma nagement station s to read and modify th e
settings of gateways, routers, switches, and other network devices. Use SNMP to configure system features for proper
operation, monitor performance and detect potential problems in the Switch, switch group or network.
Managed devices that support SNMP include software (referred to as an agent), which runs locally on the device. A
defined set of variables (managed objects) is maintained by the SNMP agent and used to manage the device. These
objects are defined in a
Manage ment Informatio n Base (M IB), which pro vides a sta ndard p resentation of the
information controlled by the on-board SNMP agent. SNMP defines both the format of the MIB specifications and the
protocol used to access this information over the network.
The Switch supports SNMP versions 1, 2c, and 3. You can specify which version of SNMP you want to use to monitor
and control the Switch. T he three versions of SNMP vary in the level of se curity provided between the management
station and the network device.
In SNMP v.1 and v.2, use r authentication is accomp lished using ' community strings', which function like passwords.
The remote user SNMP application and the Switch SNMP must use the same community string. SNMP packets from
any station that has not been authenticated are ignored (dropped).
The default community strings for the Switch used for SNMP v.1 and v.2 management access are:
•
public - Allows authorized management stations to retrieve MIB objects.
•
private - Allows authorized management stations to retrieve and modify MIB objects.
SNMP v.3 u ses a more sop histicated authenticati on pro cess that is sepa rated into two parts. The first part is to
maintain a list of users an d their attribu tes that are a llowed to act as SNMP managers. The se cond part descri bes
what each user on that list can do as an SNMP manager.
The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may
also be set for a listed group of SNMP managers. Thus, you may create a group of SNMP managers that are allowed
to view rea d-only information or receive traps u sing SNMP v.1 while assig ning a highe r level of secu rity to another
group, granting read/write privileges using SNMP v.3.
20
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Using SNMP v.3 individual use rs or groups of SNMP m anagers can be allowed to pe rform o r be restricted fro m
performing specific SNMP management functions. The functions allowed or restricted are defined using the Object
Identifier (OID) associated with a specific MIB. An additional layer of security is available for SNMP v.3 in that SNMP
messages may be encrypted. To read more about how to configure SNMP v.3 settings for the Switch read the section
entitled Management.
Traps
Traps are messages that alert network personnel of events that occur on the Switch. The events can be as serious as
a reboot (so meone a ccidentally turne d OFF the Switch ), or less se rious like a port st
atus ch ange. The Switch
generates traps and se nds them to the trap recipient (or net work manager). Typical traps include trap messages for
Authentication Failure, Topology Change and Broadcast\Multicast Storm.
MIBs
The Switch in the Management Information Base (MIB) stores management and counter information. The Switch uses
the standard MIB-II Management Information Base m odule. Consequently, values for MIB o bjects can b e retrieved
from any SNMP-based network management software. In addition to the s tandard MIB-II, the Switch also supports its
own proprietary enterprise MIB as an extended Ma nagement Information Base. Specifying the MIB Object Identifier
may also retrieve the proprietary MIB. MIB values can be either read-only or read-write.
IP Address Assignment
Each Switch must be assigned its own IP Address, which is used for communication with an SNMP network manager
or other TCP/IP application (for exam ple BOOTP, TFTP). The Switch' s default IP address is 10.90.9 0.90. You can
change the default Switch IP address to meet the specification of your networking address scheme.
The Switch is also assigned a unique MAC address by the factory. This MAC address cannot be changed, and can be
found by entering the command "show switch" into the command line interface, as shown below.
DES-3528:admin#show switch
Command: show switch
Device Type : DES-3528 Fast Ethernet Switch
Unit ID : 1
MAC Address : 00-21-91-AF-EA-00
IP Address : 10.90.90.90 (Manual)
VLAN Name : default
Subnet Mask : 255.0.0.0
Default Gateway : 0.0.0.0
Boot PROM Version : Build 1.00.B008
Firmware Version : Build 2.60.017
Hardware Version : A4
Serial Number : P1UQ287000012
System Name :
System Location :
System Contact :
Spanning Tree : Disabled
GVRP : Disabled
IGMP Snooping : Disabled
MLD Snooping : Disabled
VLAN Trunk : Disabled
Telnet : Enabled (TCP 23)
Web : Enabled (TCP 80)
CTRL+C ESC q Quit SPACE n Next Page ENTER Next Entry a All
Figure 4- 4. Show switch command
21
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
The Switch's MAC address can also be found from the Web management program on the Switch Information (Basic
Settings) window on the Configuration menu.
The IP addre ss for the Switch must be set before it
can be mana ged with the Web -based manager. The Switch IP
address can be automatically set using BOOTP or DHCP protocols, in which case the actual address assigned to the
Switch must be known.
The IP address may be set using the Command Line Interface (CLI) over the console serial port as follows:
Starting at the command line prompt, enter the commands
config ipif System ipaddress xxx.xxx.xxx.xxx/yyy.yyy.yyy.yyy
Where the x's rep resent the IP addre ss to be assig ned to the IP interface n amed System and the y's repre sent the
corresponding subnet mask.
Alternatively, you can en ter config ipif System ipaddress xxx.xxx.xxx.xxx/z. Where the x's rep resent the IP
address to be assigned to the IP interface named System and the z represents the corresponding number of subnets
in CIDR notation.
The IP interface named System on the Switch can be assigned an IP address and subnet mask, and then be used to
connect a management station to the Switch's Telnet or Web-based management agent.
DES-3528:admin#config ipif System ipaddress 10.90.90.90/255.0.0.0
Command: config ipif System ipaddress 10.90.90.90/8
Success.
DES-3528:admin#
Figure 4- 5. Assigning the Switch an IP Address
In the above example, the Switch was assigned an IP address of 10.90.90.90 with a su bnet mask of 255 .0.0.0. (the
CIDR form was used to set the address (10.90.9 0.90/8). The system message Success indicates that the command
was executed successfully. The Switch can now be configured and managed via Telnet and the CLI or via the Web-
based management.
22
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Section 5
Web-based Switch Configuration
Introduction
Login to Web Manager
Web-based User Interface
Web Pages
Introduction
All softwa re functions of the Switch can be man aged, configu red an d mo nitored via th e embe dded Web-based
(HTML) interface. The Switch can be m anaged from remote stations anywhere on the net work through a stand ard
browser such as Mozilla Fi refox or Microsoft Internet Explorer. The browser acts as a universal access tool and can
communicate directly with the Switch using the HTTP protocol.
The Web-based management module and the console program (a nd Telnet) are diffe rent ways to acce ss the same
internal switching software and configure it. Thus, all se ttings encountered in Web-based management are the sam e
as those found in the console program.
Login to Web Manager
To begin m anaging the Switch, sim ply run the bro wser you ha ve installed o n your co mputer and p oint it to the IP
address you have defined for the
dev ice. Th e URL in the address bar sh
ould read som
ething like:
http://123.123.123.123, where the numbers 123 represent the IP address of the Switch.
NOTE: The Factory default IP address for the Switch is 10.90.90.90.
This opens the management module's user authentication window, as seen below.
Figure 5- 1. Enter Network Password dialog
Enter “admin” in both the User Name and Password fields and click OK. This will open the Web-based user interface.
The Switch management features available in the web-based manager are explained below.
23
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Web-based User Interface
The user interface provides access to various Switch configuration and management windows, allows you to view
performance statistics, and permits you to graphically monitor the system status.
Areas of the User Interface
The figure below shows the user interface. The user interface is divided into three distin ct areas as described in the
table.
Area 2
Figure 5- 2. Main Web-Manager page
Area Function
Area 1
Select the folder or wi ndow to be displ ayed. The folder ico ns can be opene d to display the hyper-
linked window buttons and subfolders contained within them. Cli ck the D-Link logo to go t o the D-
Link Website.
Area 2
Presents a graphical near real-time image of the f ront panel of the Switch. T his area displays the
Switch's port s and expa nsion modul es, sho wing por t activity, duplex mode, or flow
control,
depending on the specified mode.
Various areas of the grap hic can be selected for performing management functions, including port
configuration.
Area 3
Presents switch information based on your selection and the entry of configuration data.
Area 3
Area 1
24
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
NOTICE: Any changes made to the Switch configuration during the current
session must be saved in the Save Changes Web menu (explained below)
or use the command line interface (CLI) command save.
Web Pages
When you connect to the management mode of the Switch with a Web browser, a login window is displayed. Enter a
user name and password to access the Switch's management mode.
Below is a list and description of the main folders available in the Web interface:
System Configuration – System Information Settings, Dual Co nfiguration Settings, Firmware Information Settings,
Port Configuration, Port Settings, Port De scription Settings, Port Error Disabled, Jumbo Frame Settings, PoE, PoE
System Settings, PoE Port Se ttings, Serial Port Settings, System Log Co nfiguration, System Log Settings, System
Log Server Settings, System Log, Syste m Log & T rap Settings, System Severity Settings, Time Range Settings,
Time Settings, User Accounts Settings, Stacking, Stacking Device Table, and Stacking Mode Settings.
Management – ARP, Static ARP Settings , Proxy ARP Settings , ARP Tabl e, Gratuito us ARP, Gratuit ous A RP
Global S ettings, G ratuitous ARP Setti ngs, IPv6 Neighb or Settings, IP Interface, System
IP Addre ss Settings,
Interface Settings, Man agement Settings, Sessio n Tabl e, Singl e IP Manag ement, Singl e IP Setting s, SNMP
Settings, SNMP Global Settings, SNM
P Traps Sett ings, SNMP Linkchange Traps Settings, SNMP View Tabl
e
Settings, SNMP Commu nity Table Settings, SNMP Group Table Settings, SNMP Engine ID Settings, S NMP User
Table Settings, SNMP Host Table Settings, SNMP v6Host Table Settings, RMON Settings, Telnet Setings, and Web
Settings.
L2 Features – VLAN, 802.1Q VLAN Settings, 802
.1v Protocol VLAN, 802.1 v Pr otocol Group Setting s, 802.1 v
Protocol VLAN Settings, Asymmetri c VLAN Settings, GVRP, GVRP Global
Settings, GVRP Port Settings, MAC-
based VLAN Settings, PVID Auto Assign Setting
s, S ubnet VLAN, Subnet VLAN Settings, VLAN Prece
dence
Settings, VLAN Counter Settings, Voice VLAN, Voice VLAN Global Settings, Voice VLAN Port Settings, Voice VLAN
OUI Settings, Voic e VLAN Devic e, VL AN Trunk Settings, Browse VLAN, S
how VLAN Ports , Q-in-Q, Q-in-Q
Settings, VL AN Tran slation Setting s, Layer 2 Prot ocol Tunneling Setting s, Spannin g T ree, STP Bri dge Gl obal
Settings, STP Port Settin gs, MST Configuration Identific ation, STP Instance S ettings, MSTP Port Information, Li nk
Aggregation, Port Trunking Settings, LACP Port Settings, FDB, Static FDB Sett ings, Unicast Static FDB Settings ,
Multicast Static FDB Settings, MAC Notification Settings, MAC Address Aging Time Settings, MAC Address Table,
ARP & FDB Table, L2 M ulticast Control, IGMP Sn ooping, IGMP Snooping Settings, IGMP Snoopin g Rate Limit
Settings, IGMP Snoopin g Static Gro up Settings, IGMP Route r Port, IGMP Snooping G
roup, IGMP Snooping
Forwarding Table, IGMP Snooping Counter, CPU Filter L3 Control Packet Settings, MLD Snooping, MLD Snooping
Settings, ML D Sno oping Rate Li mit Settings, ML D S nooping S tatic Group Settings, ML D Route r Po rt, MLD
Snooping Group, MLD Snooping Forwarding Table, MLD Snooping Counter, Multicast VLAN, IGMP Multicast Group
Profile Settings, IGMP Snoopin g Multicast VLAN Se ttings, MLD Multicast Group Profile Se ttings, MLD Snooping
Multicast VLAN Settings, Multic ast Filtering, IPv4 M ulticast Profile Settings, IPv4 Limited Multicast Range Settings,
IPv4 Max Mu lticast Group Settings, Multicast Filtering Mode, ERPS Settings, LLDP, LLDP Global Settings, LLDP
Port Settings, LLDP Management Address List, LLDP Basic TLVs Settings, LLDP Dot1 TLVs Settings, LLDP Dot3
TLVs Settings, LLDP Statistics System, LLDP Local Port Information, and LLDP Remote Port Information.
L3 Features – Local Ro ute Settings, IPv4 Static/Default Ro ute Se ttings, IPv4 Route Table, IPv6 Static/Defa
ult
Route Settings, IPv6 Route Table, Policy Route Settings, and IP Forwarding Table.
QoS – 8 02.1p Setting s, 802.1p Default Priority Settings , 80 2.1p Use r Pri ority Settings, 802.1p Map Settings,
Bandwidth Control, Bandwidth Control Settings, Queue Bandwidth Control Settings, Traffic Control Settings, DSCP,
DSCP Trust Settings, DS CP Map Settings, HOL Blocked Prevention, Scheduling Settings, QoS Sched uling, QoS
Scheduling Mechanism, SRED, SRED Settings, and SRED Drop Counter.
ACL – ACL Configuration Wizard, Access Profile List, CPU Access Profile List, ACL Finder, and ACL Flow Meter.
Security – 8 02.1X, 802.1 X Global Set tings, 802.1X Port Se ttings, 802.1X User Settings , Guest VLAN Settings,
RADIUS, Authentication RADIUS Serve r Settings, RADIUS Acco unting Settings, RADIUS Authentication, RADIUS
Account Client, IP-MAC-Port Binding (IMPB), IMPB Global Settings, IMPB Port Settings, IMPB Entry Settings, MAC
Block Li st, DHCP Snoopi ng, DH CP Snoopi ng Maximum En try Settings, DH CP Snooping Entry, ND Snoop, ND
Snoop Maximum Entry Settings, ND Snoop Entry, MAC-based Access Control (MAC), MAC-based Access Control
Settings, MAC-based Access Control Local Settings, MAC-based Access Control Authentication State, Web-based
Access Control (WAC), WAC Global S ettings, WAC User Settings, WAC Port Settings, WAC Authentication State,
Japanese Web-based Access Control (JWAC), JWAC Global Settings, JWA C Port Settings, JWA C User Settings,
JWAC Authentication State, JWAC Customize Page Language, JWAC Customize Page, Compound Authentication,
25
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Compound Authentication Settings, Co mpound Authentication Guest VLAN Se ttings, Port Secu rity, Port Security
Settings, Port Security VLAN Settings,
Port Securit y Entries, ARP Spoofing Prev ention Settings, BPDU Attack
Protection, Loopback Detection Settin gs, Traffic Se gmentation Settings, NetBIOS Filt ering Settings, DHCP Serve r
Screening, DHCP Serve r Screeni ng Port Settings, DHCP O
ffer Permit Entry Settings, Access Authentication
Control, Ena ble Admin, A uthentication Policy Settings, A pplication Authentication Settings, Authentication Serve r
Group Settings, Authenticaton Server Settings, Login Method Lists Settings, Enable Meth od Lists Settings, Lo cal
Enable Password Settings, SSL Settings, SSH, SSH Settings , SSH Authentication Method and Algorithm Settings,
SSH User Authentication List, Trusted Host Settings, and Safeguard Engine Settings.
Network Application – DHCP, DHCP Relay, DHCP Relay Global Settings, DHCP Relay Interface Settings, DH CP
Relay VLAN Settings, DHCP R elay Option 60 Serv er Setting s, DH CP Rel ay Option 60 Settings, DHCP R elay
Option 61 Settings, DHCP Server, DHCP Server Global Settings, DHCP Server Excl ude Address Settings, DHCp
Server Pool Settings, DH CP Server M anual Binding, DHCP Server Dynamic Binding, DH CP Conflict IP, DHCP v6
Relay, DHCPv6 Relay Global Settings, DH CPv6 Relay Settings, DH CP Local Relay Settings, DNS, D NS Relay,
DNS Relay Global Settings, DNS Relay Static Settings, PPPoE Circuit ID Insertion Settings, SNTP, SNTP Settings,
and Time Zone Settings.
OAM – CFM , CFM Settin gs, CFM Port Setings, CFM Loopba ck Settings, CF M Linktra ce Settings, CF M Packet
Counter, CFM Fault Table, CFM MP Tabler, Ethernet OAM, Ethernet OAM Settings , Ethernet OAM Configuratio n
Settings, Ethernet OAM Event Log, Ethernet OAM Statistics, DULD Settings, Cable Diagnostics, .
Monitoring – Utilization, CPU Utili zation, DRAM & Flash Utili zation, Port Utilization, Statistics, Port Statistics,
Packets, Received (RX), UMB_cast (RX), Transmitted (TX), Errors, Received (RX), Tran smitted (TX), Packet Size,
VLAN Co unter Statistics, Mirro r, Port Mirro r Settings , RSPA N Settings, sFlow, sFl
ow Global Settings, sFlo
w
Analyzer Server Settings, sFlo w Flow Sampler Settings, s Flow Counter Poller Settings, Ping Test, Trace Route,
Peripheral, and Device Status.
NOTE: Be sure to co nfigure the u ser name and p assword in t he User
Accounts window before connecting the Switch to the greater network.
26
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Appendix A
Technical Specifications
General
Protocols
Fiber-Optic
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.3z Gibabit Ethernet. (SFP “Mini GBIC”)
IEEE 802.1D Spanning Tree
IEEE 802.1D/S/W Spanning Tree
IEEE 802.1Q VLAN
IEEE 802.1p Priority Queues
IEEE 802.1X Port Based Network Access Control
IEEE 802.3ad Link Aggregation Control
IEEE 802.3x Full-duplex Flow Control
IEEE 802.3 NWay auto-negotiation
IEEE 802.3af standard (only for PoE)
SFP Support:
DEM-310GT (1000BASE-LX)
DEM-311GT (1000BASE-SX)
DEM-314GT (1000BASE-LHX)
DEM-315GT (1000BASE-ZX)
DEM-312GT2 (1000BASE-SX)
DEM-210 (Single Mode 100BASE-FX)
DEM-211 (Multi Mode 100BASE-FX)
WDM Transceivers Supported:
DEM-330T (TX-1550/RX-1310nm), up to 10km, Single-Mode
DEM-330R (TX-1310/RX-1550nm), up to 10km, Single-Mode
DEM-331T (TX-1550/RX-1310nm), up to 40km, Single-Mode
DEM-331R (TX-1310/RX-1550nm), up to 40km, Single-Mode
Standards
IEEE802.3
Data Transfer Rates:
Ethernet
Fast Ethernet
Gigabit Ethernet
Half-duplex Full-d
uplex
10 Mbps
20Mbps
100Mbps 200Mb
ps
n/a
2000Mbps
Topology
Star
Network Cables
Cat.5 Enhanced for 1000BASE-T
UTP Cat.5, Cat. 5 Enhanced for 100BASE-TX
UTP Cat.3, 4, 5 for 10BASE-T
EIA/TIA-568 100-ohm screened twisted-pair (STP)(100m)
Number of Ports
DES-3528/DES-3528DC/DES-3528P
24 x 10/100Base -T Port s, 2 x 1000Base
-T/SFP Comb o Port s, 2 x
1000Base-T ports
DES-3552/DES-3552P
48 x 10/10 0Mbps T Port s, 2 x 100
0Base-T/SFP Comb o Port s, 2 x
1000Base-T ports
27
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Physical and Environmental
Internal Power Supply
DES-3528
Input: 100~240V, AC/0.5A(Max), 50~60Hz
Output: 12V, 1.2A(Max)
Internal universal power supply
DES-3552
Input: 100~240V, AC/0.8A(Max), 50~60Hz
Output: 12V, 2.1A(Max)
Internal universal power supply
DES-3528P
Input: 100~240V, AC/6.3A(Max), 50~60Hz
Output: 50V, 7.5A(Max), 12V, 1.4A(Max)
Internal universal power supply
DES-3552P
Input: 100~240V, AC/6.9A(Max), 50~60Hz
Output: 50V, 7.5A(Max), 12V, 2.65A(Max)
Internal universal power supply
DES-3528DC
DC Power Input: 36-75 V,DC/ 0.6A (Max)
Output: 12V, 1.2A (Max)
Internal universal power supply.
DES-3528/DES-3552
Provides one connector on the re ar panel to in stall an optio nal external RPS
(DPS-200) to enhan ce the reliability. When the internal po
wer fails, the
optional ext ernal RPS will take over all the
power imm ediately and
automatically.
DES-3528P/DES-3552P
Provides one connector on the re ar panel to in stall an optio nal external RPS
(DPS-600) to enhan ce the reliability. When the internal po
wer fails, the
optional ext ernal RPS will take over all the
power imm ediately and
automatically.
Power Consumption
DES-3528
Max. 20.5 watts
DES-3528DC
Max. 18.38 watts
DES-3552
Max. 33.1 watts
DES-3528P
Max. 505.1 watts
DES-3552P
Max. 506.4 watts
Operating Temperature
DES-3528:
A1/A2: 0° to 45° C
28
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
A3/A4: 0° to 50° C
DES-3528DC: 0° to 45° C
DES-3528P: 0° to 50° C
DES-3552:
A1: 0° to 45° C
A2/A3: 0° to 50° C
DES-3552P: 0° to 50° C
Storage Temperature
-40 - 70°C
Humidity
Operation Relative Humidity: 5 - 95% non-condensing.
Storage Relative Humidity: 5 – 95% non-condensing.
Dimensions
DES-3528/DES-3528DC
441(W) x 210(D) x 44(H) mm
DES-3552/DES-3528P
441(W) x 310(D) x 44(H) mm
DES-3552P
441(W) x 370(D) x 44(H) mm
Weight
DES-3528
2.51kg (5.53lbs)
DES-3528DC
2.52kg (5.55lbs)
DES-3552
4.09kg (9.01lbs)
DES-3528P
5.42kg (11.94lbs)
DES-3552P
6.52kg (14.37lbs)
EMI
CE Class A, FCC Class A, C-Tick, VCCI
Safety
CB Report, UL
29
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
Performance
Feature
Detailed Description
Wire speed on all FE/GE ports
Full-wire speed (full-duplex) operation on all FE/GE ports
Forwarding Mode
Store and Forward
Switching Capacity
DES-3528/DES-3528DC/DES-3528P
12.8Gbps
DES-3552/DES-3552P
17.6Gbps
64 Byte system packet fo rwarding
rate
DES-3528/DES-3528DC/DES-3528P
9.5 million 64-byte packets per second.
DES-3552/DES-3552P
13.1 million 64-byte packets per second.
Priority Queues
8 Priority Queues per port
MAC Address Table
Supports 16K MAC address
Transmission Method
Store-and-forward
Packet Buffer
1 MB per device
Packet Filtering/Forward Rate
14,881 pps (10M port)
148,810 pps (100M port)
1,488,100 pps (1 Gbps port)
Port Functions
Feature
Detailed Description
Console Port
DCE RS-232 DB-9 for out-of-band configuration of the software features.
10/100BaseT ports
Compliant to following standards:
•
IEEE 802.3 compliance
•
IEEE 802.3u compliance
•
Support Half/Full-Duplex operations
•
All ports support Auto MDI-X/MDI-II cross over
•
IEEE 802.3x Flow Cont
rol support fo r Full-Dupl ex mode, Back Pressure
when Half-Duplex mode, and Head-of-line blocking prevention.
•
Compliant IEEE802.3af standard(only for PoE)
Combo ports
2 combo 1000BASE-T/SFP ports
1000BASE-T ports compliant to following standards:
•
IEEE 802.3 compliance
•
IEEE 802.3u compliance
•
IEEE 802.3ab compliance
30
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
•
Support Full-Duplex operations
•
IEEE 802.3x Flow Control support for Full-Duplex mode, back pressure when
Half-Duplex mode, and Head-of-line blocking prevention
SFP Transceivers Supported:
• DEM-310GT
(1000BASE-LX)
•
DEM-311GT (1000BASE-SX)
• DEM-314GT
(1000BASE-LHX)
• DEM-315GT
(1000BASE-ZX)
• DEM-312GT2
(1000BASE-SX)
•
DEM-210 (Single Mode 100BASE-FX)
•
DEM-211 (Multi Mode 100BASE-FX)
WDM Transceiver Supported:
•
DEM-330T (TX-1550/RX-1310nm),up to 10km,Single-Mode
•
DEM-330R (TX-1310/RX-1550nm), up to 10km,Single-Mode
•
DEM-331T (TX-1550/RX-1310nm), up to 40km, Single-Mode
•
DEM-331R (TX-1310/RX-1550nm), up to 40km, Single-Mode
Compliant to following standards:
•
IEEE 802.3z compliance
•
IEEE 802.3u compliance
1000BASE-T ports
1000BASE-T ports compliant to following standards:
•
IEEE 802.3 compliance
•
IEEE 802.3u compliance
•
IEEE 802.3ab compliance
•
Support Full-Duplex operations
•
IEEE 802.3x Flow
Control support for Full
-Duplex mode, back pressure
when Half-Duplex mode, and Head-of-line blocking prevention
PoE Features DES-3528P and DES-3552P
Feature
Detailed Description
PoE Capable Ports
DES-3528P: Port 1-24; DES-3552P: Port 1-48
Maximum Power Feeding
DES-3528P
Port 1~8: 30W
Port 9~24: 15.4W
Device power budget : 370W
DES-3552P
Port 1~8: 30W
Port 9~48: 15.4W
Device power budget : 370W
31
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
PoE Specification
1. Compliant with 802.3af PoE standard. And the high power ports (1~8) can support
PoE up to 30W.
2. Auto discovery feature, automatically recognize the connection of PD device and
immediately sends power to it
3. Auto disable port if the port current is over 350mA for 802.3af mode while other
ports remain active
4. Active circuit protection, automatically disables the port if there is a short while
other ports remain active
5. PD should be able to receive the power following the classification below
Class
Usage
Max power used by PD
0
Default
0.44 to 12.95W
1
Optional
0.44 to 3.84W
2
Optional
3.84 to 6.49W
3
Optional
6.49 to 12.95W
4
Reserved
12.95W to 30W
6. PSE should be provide the power following the classification below
Class
Usage
Max power used by PD
0
Default
15.4W
1
Optional
4.0W
2
Optional
7.0W
3
Optional
15.4W
4
Reserved
15.4W ~ 30W
7. DES-3528P/52P follow the standard PSE pin-out standard of Alternative A which
is sending out power over number 1,2,3,6 pins of 8 wires of CAT5 UTP cable
Pin
Signal
Description
1
Receive+ & Power-
Negative Vport
2
Receive- & Power-
Negative Vport
3
Transmit+ & Power+
Positive Vport
4
5
6
Transmit- & Power+
Positive Vport
7
8
8. All the PoE ports can work with all D-Link 802.3af capable devices
9. All the PoE ports can work with all non-802.3af capable D-Link AP, IP Cam and IP
phone via DWL-P50
32
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
FE Port Pin Assignment for Data Pairs: (MDI-X)
PIN#
Signal
Description
1
Receive+
Positive Receive signal
2
Receive-
Negation Receive signal
3
Transmit+
Positive Transmit signal
4
5
6
Transmit-
Negation Transmit signal
7
8
FE Port PSE Pinout Assignment for Power Pairs: (alternative A MDI-X)
PIN#
Signal
Description
1
Negative Vport
Negative power signal
2
Negative Vport
Negative power signal
3
Positive Vport
Positive power signal
4
5
6
Positive Vport
Positive power signal
7
8
33
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
34
Appendix B
Cable Lengths
Use the following table to as a guide for the maximum cable lengths.
Standard
Media Type
Maximum Distance
SFP
1000BASE-LX, Single-mode fiber module
1000BASE-SX, Multi-mode fiber module
1000BASE-LHX, Single-mode fiber module
1000BASE-ZX, Single-mode fiber module
10km
550m
40km
80km
1000BASE-T
Category 5e UTP Cable
100m
100BASE-TX
Category 5 and Category 5e UTP Cable (100 Mbps)
100m
10BASE-T
Category 3, 4, 5, and 5e UTP Cable (10 Mbps)
100m
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
35
Appendix C
Glossary
1000BASE-SX: A short laser wavelength on multimode fiber optic cable for a maximum length of 2000 meters
1000BASE-LX: A long wavelength for a "long haul" fiber optic cable for a maximum length of 10 kilometers
1000BASE-T: 1000Mbps Ethernet implementation over Category 5E cable.
100BASE-FX: 100Mbps Ethernet implementation over fiber.
100BASE-TX: 100Mbps Ethernet implementation over Category 5 and Type 1 Twisted Pair cabling.
10BASE-T: The IEEE 802.3 specification for Ethernet over Unshielded Twisted Pair (UTP) cabling.
aging: The a utomatic removal of dyna mic entries from the Switch Database which have timed-out and are no longe r
valid.
ATM: Asynchronous Transfer Mode. A con nection oriented transmission protocol based on fixed length cells (p ackets).
ATM is designed to carry a complete range of user traffic, including voice, data and video signals.
auto-negotiation: A featu re on a port, which allo ws it to adverti se its capabilities for spee d, duplex and flow contro l.
When connected to a n end station that also supports auto-negotiation, the l ink can self-detect its opt imum operating
setup.
backbone port: A port which does not learn device addresses, and which receives all frames with an unknown address.
Backbone ports are n ormally used to con nect the Switch to the backbon e of your netwo rk. Note that backb one ports
were formerly known as designated downlink ports.
backbone: The part of a network used as the primary path for transporting traffic between network segments.
bandwidth: Information capacity, measured in bits per second that a channel can transmit. The bandwidth of Ethernet is
10Mbps, the bandwidth of Fast Ethernet is 100Mbps.
baud rate: The switching speed of a line. Also known as line speed between network segments.
BOOTP: The BOOTP prot ocol allows you to automa tically map an IP addre ss to a given MAC address each time a
device is started. In addition, the protocol can assign the subnet mask and default gateway to a device.
bridge: A device that interconnects local or remote networks no matter what higher-level protocols are involved. Bridges
form a single logical network, centralizing network administration.
broadcast: A message sent to all destination devices on the network.
broadcast storm: Multiple simultane ous broadcasts that typically absorb available network band width and can cause
network failure.
console port: The port on the Switch accepting a terminal or m odem connector. It changes the parallel arrangement of
data within computers to the serial form used on data transmission links. This port is most often used for dedicated local
management.
CSMA/CD: Channel access method used by Ethernet and IEEE 802.3 standards in which devices transmit only after
finding the data channel clear for some period of time. When two devices transmit simultaneously, a collision occurs and
the colliding devices delay their retransmissions for a random amount of time.
data center switching: The point of a ggregation within a corporate network where a switch provides high-performance
access to server farms, a high-speed backbone connection and a control point for network management and security.
Ethernet: A LAN sp ecification developed jointly by Xerox, Intel and Digital Eq uipment Corporation. Ethernet netwo rks
operate at 10Mbps using CSMA/CD to run over cabling.
Fast Ethernet: 100Mbps technology based on the Ethernet/CMSA/CD network access method.
Flow Control: (IEEE 802 .3z) A means of holding packet
s back at the transmit port of
the connected end station.
Prevents packet loss at a congested switch port.
forwarding: The process of sending a packet toward its destination by an internetworking device.
full duplex: A system th at allows p ackets to b e transmitted and received at th e same time and, in effect, doubles the
potential throughput of a link.
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
36
half duplex: A system th at allows pa ckets to be transmitted and received, but not at the same time. Co ntrast with full
duplex.
IP address: Internet Protocol address. A unique identifier for a d evice attached to a network using TCP/IP. The address
is written a s four octets separated with full-stops (periods), and is ma de up of a network section, an optional subnet
section and a host section.
IPX: Internetwork Packet Exchange. A protocol allowing communication in a NetWare network.
LAN - Local Area Network: A network of conne cted computing resources (such as PCs, printers, servers) covering a
relatively small geographic area (usually not larger than a floor or building). Characterized by high data rates a nd low
error rates.
latency: The delay betwe en the time a device re ceives a packe t and the time the packet is forwa
rded out of th e
destination port.
line speed: See baud rate.
main port: The port in a resilient link that carries data traffic in normal operating conditions.
MDI - Medium Dependent Interface: An Ethernet port co nnection where the transmitter of one device is con nected to
the receiver of another device.
MDI-X - Medium Dependent Interface Cross-over: An Ethernet port connection where the internal transmit and receive
lines are crossed.
MIB - Management Information Base: Stores a device's management characteristics and parameters. MIBs are used
by the Simpl e Net work Management Protocol (S NMP) to contain attribute s of their managed systems. The Switch
contains its own internal MIB.
multicast: Single packet s copied to a specific sub
set of net work add resses. These addres ses are sp ecified in the
destination-address field of the packet.
protocol: A set of rule s for communication between devices on a network. The rules dictate format, timing, seq uencing
and error control.
resilient link: A pair of ports that can be configured so that one will take over data transmission should the other fail. See
also main port and standby port.
RJ-45: Standard 8-wire connectors for IEEE 802.3 10BASE-T networks.
RMON: Remote Monitoring. A subset of SNMP MIB II that allows monitoring and management capabilities by addressing
up to ten different groups of information.
RPS - Redundant Power System: A device that provides a backup source of power when connected to the Switch.
server farm: A cluster of servers in a centralized location serving a large user population.
SLIP - Serial Line Internet Protocol: A protocol, which allows IP to run over a serial line connection.
SNMP - Simple Network Management Protocol: A protocol originally de signed to be used in m anaging TCP/IP
internets. SNMP is presently implemented on a wide range of computers and networking equipment and may be used to
manage many aspects of network and end station operation.
Spanning Tree Protocol (STP): A b ridge-based system for p roviding faul t tolerance on netwo rks. S TP wo rks by
allowing you to implement parallel paths for network traffic, and ensure that redundant paths are disabled when the main
paths are operational and enabled if the main paths fail.
stack: A group of network devices that are integrated to form a single logical device.
standby port: The port in a resilient link that will take over data transmission if the main port in the link fails.
switch: A device, whi ch filters, forwards and flood s pa ckets ba sed o n the packe t's desti nation add ress. The S witch
learns the ad dresses associated with each switch port and builds tables based on this inf ormation to be use d for the
switching decision.
TCP/IP: A layered set of comm unications p rotocols providing Telnet terminal emulation, F TP file transf er, and oth er
services for communication among a wide range of computer equipment.
Telnet: A TCP/IP application proto col that provide s virtual term inal service, letting a user l og in to another compute r
system and access a host as if the user were connected directly to the host.
TFTP - Trivial File Transfer Protocol: Allows you t o transfer files (such as software upgrades) from a remote device
using your switch's local management capabilities.
xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide
37
UDP - User Datagram Protocol: An Internet standard protocol that allows an application program on one device to send
a datagram to an application program on another device.
VLAN - Virtual LAN: A grou p of location- an d topology-i ndependent dev ices that co mmunicate as if they are on a
common physical LAN.
VLT - Virtual LAN Trunk: A Switch-to-Switch link which carries traffic for all the VLANs on each Switch.
VT100: A type of terminal that uses ASCII characters. VT100 screens have a text-based appearance.
Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this lifetime product warranty for hardware:
Only for products purchased, delivered and used within the fifty states of the United States, the District of Columbia, U.S. Possessions or
Protectorates, U.S. Military Installations, or addresses with an APO or FPO, and;
Only with proof of purchase.
Product Warranty: D-Link warrants that the hardware portion of the D-Link product, including internal and external power supplies and fans (“Hardware”),
will be free from material defects in workmanship and materials under normal use from the date of original retail purchase of the product (“Warranty
Period”), except as otherwise stated herein.
The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Warranty will be, at D-Link’s option, to repair or
replace the defective Hardware during the Warranty Period at no charge to the owner or to refund the actual purchase price paid. Any repair or
replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement hardware need not be new or have an identical make,
model or part. D-Link may, at its option, replace the defective Hardware or any part thereof with any reconditioned product that D-Link reasonably
determines is substantially equivalent (or superior) in all material respects to the defective Hardware. Repaired or replacement hardware will be
warranted for the remainder of the original Warranty Period or ninety (90) days, whichever is longer, and is subject to the same limitations and exclusions.
If a material defect is incapable of correction, or if D-Link determines that it is not practical to repair or replace the defective Hardware, the actual price
paid by the original purchaser for the defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All Hardware or part
thereof that is replaced by D-Link, or for which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.
Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to D-Link’s then current functional
specifications for the Software, as set forth in the applicable documentation, from the date of original retail purchase of the Software for a period of ninety
(90) days (“Software Warranty Period”), provided that the Software is properly installed on approved hardware and operated as contemplated in its
documentation. D-Link further warrants that, during the Software Warranty Period, the magnetic media on which D-Link delivers the Software will be free
of physical defects. The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-
Link’s option, to replace the non-conforming Software (or defective media) with software that substantially conforms to D-Link’s functional specifications
for the Software or to refund the portion of the actual purchase price paid that is attributable to the Software. Except as otherwise agreed by D-Link in
writing, the replacement Software is provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for
the Software. Replacement Software will be warranted for the remainder of the original Warranty Period and is subject to the same limitations and
exclusions. If a material non-conformance is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-
conforming Software, the price paid by the original licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming
Software (and all copies thereof) is first returned to D-Link. The license granted respecting any Software for which a refund is given automatically
terminates.
Non-Applicability of Warranty: The Warranty provided hereunder for D-Link's products will not be applied to and does not cover any products obtained
through a special or unique pricing agreement, if such agreement provides for warranty terms different from those normally provided with the product or
set forth herein, nor to any refurbished product and any product purchased through the inventory clearance or liquidation sale or other sales in which D-
Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product and in that case, the product is being sold "As-Is"
without any warranty whatsoever including, without limitation, the Warranty as described herein, notwithstanding anything stated herein to the contrary.
Submitting A Claim: The customer shall return the product to the original purchase point based on its return policy. In case the return policy period has
expired and the product is within warranty, the customer shall submit a claim to D-Link as outlined below:
The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in sufficient
detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product).
The customer must obtain a Case ID Number from D-Link Technical Support by going to https://support.dlink.com, who will attempt to assist the
customer in resolving any suspected defects with the product. If the product is considered defective, the customer must obtain a Return Material
Authorization (“RMA”) number by completing the RMA form and entering the assigned Case ID Number at https://rma.dlink.com/.
After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it
will not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. Include any manuals or
accessories in the shipping package.
The customer is responsible for all in-bound shipping charges to D-Link. No Cash on Delivery (“COD”) is allowed. Products sent COD will either be
rejected by D-Link or become the property of D-Link. Products shall be fully insured by the customer and shipped to D-Link Systems, Inc., 17595
Mt. Herrmann, Fountain Valley, CA 92708. D-Link will not be held responsible for any packages that are lost in transit to D-Link. The repaired or
replaced packages will be shipped to the customer via UPS Ground or any common carrier selected by D-Link. Return shipping charges shall be
prepaid by D-Link if you use an address in the United States, otherwise we will ship the product to you freight collect. Expedited shipping is available
upon request and provided shipping charges are prepaid by the customer.
D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA
number is not visible from the outside of the package. The product owner agrees to pay D-Link’s reasonable handling and return shipping charges for any
product that is not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or non-
conforming.
What Is Not Covered: The Warranty provided herein by D-Link does not cover: Products that, in D-Link’s judgment, have been subjected to abuse,
accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not
contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; Initial
installation, installation and removal of the product for repair, and shipping costs; Operational adjustments covered in the operating manual for the product,
and normal maintenance; Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; Any hardware,
software, firmware or other products or services provided by anyone other than D-Link; and Products that have been purchased from inventory clearance
or liquidation sales or other sales in which D-Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product.
While necessary maintenance or repairs on your Product can be performed by any company, we recommend that you use only an Authorized D-Link
Service Office. Improper or incorrectly performed maintenance or repair voids this Warranty.
Disclaimer of Other Warranties: EXCEPT AS SPECIFICALLY SET FORTH ABOVE OR AS REQUIRED BY LAW, THE PRODUCT IS PROVIDED “AS-
IS” WITHOUT ANY WARRANTY OF ANY KIND WHATSOEVER INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY
TERRITORY WHERE A PRODUCT IS SOLD, THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO NINETY (90) DAYS. EXCEPT
AS EXPRESSLY COVERED UNDER THE WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO THE QUALITY, SELECTION AND
PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.
Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT, NEGLIGENCE,
STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF
ANY CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS
OF GOODWILL, LOSS OF REVENUE OR PROFIT, WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, FAILURE OF OTHER
EQUIPMENT OR COMPUTER PROGRAMS TO WHICH D-LINK’S PRODUCT IS CONNECTED WITH, LOSS OF INFORMATION OR DATA
CONTAINED IN, STORED ON, OR INTEGRATED WITH ANY PRODUCT RETURNED TO D-LINK FOR WARRANTY SERVICE) RESULTING FROM
THE USE OF THE PRODUCT, RELATING TO WARRANTY SERVICE, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY, EVEN IF D-LINK
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING WARRANTY IS
REPAIR, REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT. THE MAXIMUM LIABILITY OF D-LINK UNDER
THIS WARRANTY IS LIMITED TO THE PURCHASE PRICE OF THE PRODUCT COVERED BY THE WARRANTY. THE FOREGOING EXPRESS
WRITTEN WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ANY OTHER WARRANTIES OR REMEDIES, EXPRESS, IMPLIED
OR STATUTORY.
Lifetime Warranty: IF LOCAL LAW MANDATES THE USE OF A DEFINITION OF “LIFETIME WARRANTY” DIFFERENT FROM THAT PROVIDED
HEREIN, THEN THE LOCAL LAW DEFINITION WILL SUPERSEDE AND TAKE PRECEDENCE, TO THE EXTENT NECESSARY TO COMPLY.
Governing Law: This Warranty shall be governed by the laws of the State of California. Some states do not allow exclusion or limitation of incidental or
consequential damages, or limitations on how long an implied warranty lasts, so the foregoing limitations and exclusions may not apply. This Warranty
provides specific legal rights and you may also have other rights which vary from state to state.
Trademarks: D-Link is a registered trademark of D-Link Systems, Inc. Other trademarks or registered trademarks are the property of their respective
owners.
Copyright Statement: No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used
to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems, Inc., as stipulated
by the United States Copyright Act of 1976 and any amendments thereto. Contents are subject to change without prior notice. Copyright 2009 by D-Link
Corporation/D-Link Systems, Inc. All rights reserved.
CE Mark Warning: This is a Class A product. In a residential environment, this product may cause radio interference, in which case the user may be
required to take adequate measures.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communication. However, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a residential
environment is likely to cause harmful interference to radio or television reception. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
For detailed warranty information applicable to products purchased outside the United States, please contact the corresponding
local D-Link office.
Register your D-Link product online at http://support.dlink.com/register/
Product registration is entirely voluntary and failure to complete or return this form will
not diminish your warranty rights.
You can find software updates and user documentation on the D-
Link website.
D-Link provides free technical support for customers within the
United States and within Canada for the duration of the service
period, and warranty confirmation service, during the warranty
period on this product. U.S. and Canadian customers can contact
D-Link technical support through our website, or by phone.
Tech Support for customers within the United States:
D-Link Technical Support over the Telephone:
USA - 877-DLINK-55 (877-354-6555)
D-Link Technical Support over the Internet:
http://support.dlink.com
Tech Support for customers within Canada:
D-Link Technical Support over the Telephone:
877-354-6560
D-Link Technical Support over the Internet:
http://support.dlink.com
United Kingdom (Mon-Fri)
Home Wireless/Broadband 0871 873 3000 (9.00am–06.00pm, Sat 10.00am-02.00pm)
Managed, Smart, & Wireless Switches, or Firewalls 0871 873 0909 (09.00am – 05.30pm)
(BT 10ppm, other carriers may vary.)
Ireland (Mon-Fri)
All Products 1890 886 899 (09.00am-06.00pm, Sat 10.00am-02.00pm)
€0.05ppm peak, €0.045ppm off peak Times
Internet
http://www.dlink.co.uk
ftp://ftp.dlink.co.uk
Technische Unterstützung
Deutschland:
Web:
http://www.dlink.de
Telefon:
+49(0)1805 2787 0,14 € pro Minute
Zeiten:
Mo. –Fr. 08:30 – 17:30 Uhr
Österreich:
Web:
http://www.dlink.at
Telefon:
+43(0)820 480084 0,116 € pro Minute
Zeiten:
Mo. –Fr. 08:30 – 17:30 Uhr
Schweiz:
Web:
http://www.dlink.ch
Telefon:
+41(0)848 331100 0,08 CHF pro Minute
Zeiten:
Mo. –Fr. 08:30 – 17:30 Uhr
* Gebühren aus Mobilnetzen und von anderen Providern können abweichen.
Assistance technique D-Link sur internet :http://www.dlink.fr
Assistance technique D-Link par téléphone : 0820 0803 03
0.12 € TTC/min depuis un poste fixe
Du lundi au vendredi de 9h à 19h (hors jours fériés)
TECHNISCHE ONDERSTEUNING
Technische ondereuning voor klanten in Nederland:
www.dlink.nl / 0900 501 2007 / €0.15per minuut.
Tech Support for customers within Belgium:
www.dlink.be / 070 66 06 40 / €0.175per minuut(spitsuren), €0.0875per minuut(daluren)
Technische ondereuning voor klanten in Luxemburg:
www.dlink.be / +32 70 66 06 40
Asistencia Técnica
Asistencia Técnica Telefónica de D-Link: +34 902 30 45 45
0,067 €/min
De Lunes a Viernes de 9:00 a 19:00
http://www.dlink.es
Supporto tecnico
Supporto Tecnico dal lunedì al venerdì dalle ore 9.00 alle ore 19.00 con orario
continuato
Telefono: 199400057
http://www.dlink.it/support
Telefoniczna pomoc techniczna firmy D-Link: 0 801 022 021
Pomoc techniczna firmy D-Link świadczona przez Internet:
http://www.dlink.eu/support/
Technická podpora
Web: http://www.dlink.cz/support/
E-mail: [email protected]
Telefon ČR: +420 211 151 640 nebo SK: +421 (0)692 147 110
Telefonická podpora je v provozu: PO - PÁ od 09:00 do 17:00
Volání je zpoplatněno dle příslušných tarifů Vašeho operátora.
Technikai Támogatás
Tel. : 06 1 461-3001
Fax : 06 1 461-3004
Land Line 14,99 HUG/min - Mobile 49.99,HUF/min
email : [email protected]
URL : http://www.dlink.hu
Teknisk Support
D-Link Teknisk Support over Internett: http://www.dlink.no
D-Link Teknisk telefonsupport: 820 00 755
(Hverdager 08:00-20:00)
Teknisk Support
D-Link teknisk support over telefonen: Tlf.: 9013 8899
Normale åbningstider: Hverdage kl. 08:00 - 20:00
D-Link teknisk support på Internettet: http://www.dlink.dk
Teknistä tukea asiakkaille Suomessa:
Internetin kautta : http://www.dlink.fi
Arkisin klo. 9 - 21
Numerosta : 0600 155 57
Τεχνική Υποστήριξη
D-Link Hellas Support Center
Κεφαλληνίας 64, 11251 Αθήνα,
Τηλ: 210 86 11 114 (Δευτέρα- Παρασκευή 09:00-17:00)
Φαξ: 210 8611114
http://www.dlink.gr/support
Assistência Técnica
Assistência Técnica da D-Link na Internet:
http://www.dlink.pt
e-mail: [email protected]
Teknisk Support
D-Link Teknisk Support via Internet: http://www.dlink.se
D-Link Teknisk Support via telefon: 0900-100 77 00
Vardagar 08:00-20:00
Hvala vam na odabiru D-Link proizvoda. Za dodatne informacije, podršku
i upute za korištenje uređaja, molimo vas da posjetite D-Link internetsku
stranicu na www.dlink.eu
www.dlink.biz/hr
Tehnična podpora
Zahvaljujemo se vam, ker ste izbrali D-Link proizvod. Za vse nadaljnje
informacije, podporo ter navodila za uporabo prosimo obiščite D-Link - ovo
spletno stran www.dlink.eu
www.dlink.biz/sl
Suport tehnic
Vă mulţumim pentru alegerea produselor D-Link. Pentru mai multe informaţii,
suport şi manuale ale produselor vă rugăm să vizitaţi site-ul D-Link www.dlink.eu
www.dlink.ro
You can find software updates and user documentation on the D-Link website.
Tech Support for customers in
Australia:
Tel: 1300-766-868
24/7 Technical Support
Web: http://www.dlink.com.au
E-mail: [email protected]
India:
Tel: 1800-233-0000 (MTNL & BSNL Toll Free)
+91-832-2885700 (GSM, CDMA & Others)
Web: www.dlink.co.in
E-Mail: [email protected]
Singapore, Thailand, Indonesia, Malaysia,
Philippines, Vietnam:
Singapore - www.dlink.com.sg
Thailand - www.dlink.co.th
Indonesia - www.dlink.co.id
Malaysia - www.dlink.com.my
Philippines - www.dlink.com.ph
Vietnam - www.dlink.com.vn
Korea:
Tel : +82-2-2028-1810
Monday to Friday 9:00am to 6:00pm
Web : http://d-link.co.kr
E-mail : [email protected]
New Zealand:
Tel: 0800-900-900
24/7 Technical Support
Web: http://www.dlink.co.nz
E-mail: [email protected]
South Africa and Sub Sahara Region:
Tel: +27-12-665-2165
08600 DLINK (for South Africa only)
Monday to Friday 8:30am to 9:00pm South Africa
Time
Web: http://www.d-link.co.za
E-mail: [email protected]
Saudi Arabia (KSA):
Tel: +966 01 217 0008
Fax: +966 01 217 0009
Saturday to Wednesday 9.30AM to 6.30PM
Thursdays 9.30AM to 2.00 PM
E-mail: [email protected]
D-Link Middle East - Dubai, U.A.E.
Plot No. S31102,
Jebel Ali Free Zone South,
P.O.Box 18224, Dubai, U.A.E.
Tel: +971-4-8809022
Fax: +971-4-8809066 / 8809069
Technical Support: +971-4-8809033
General Inquiries: [email protected]
Tech Support: [email protected]
Egypt
1, Makram Ebeid Street - City Lights Building
Nasrcity - Cairo, Egypt
Floor 6, office C2
Tel.: +2 02 26718375 - +2 02 26717280
Technical Support: +2 02 26738470
General Inquiries: [email protected]
Tech Support: [email protected]
Kingdom of Saudi Arabia
Office # 84 ,
Al Khaleej Building ( Mujamathu Al-Khaleej)
Opp. King Fahd Road, Olaya
Riyadh - Saudi Arabia
Tel: +966 1 217 0008
Technical Support:
+966 1 2170009 / +966 2 6522951
General Inquiries: [email protected]
Tech Support: [email protected]
Pakistan
Islamabad Office:
61-A, Jinnah Avenue, Blue Area,
Suite # 11, EBC, Saudi Pak Tower,
Islamabad - Pakistan
Tel.: +92-51-2800397, 2800398
Fax: +92-51-2800399
Karachi Office:
D-147/1, KDA Scheme # 1,
Opposite Mudassir Park, Karsaz Road,
Karachi – Pakistan
Phone: +92-21-34548158, 34326649
Fax: +92-21-4375727
Technical Support: +92-21-34548310, 34305069
General Inquiries: [email protected]
Tech Support: [email protected]
You can find software updates and user documentation on the D-Link website.
Tech Support for customers in
Iran
Unit 5, 5th Floor, No. 20, 17th Alley , Bokharest
St. , Argentine Sq. ,
Tehran IRAN
Postal Code : 1513833817
Tel: +98-21-88880918,19
+98-21-88706653,54
General Inquiries: [email protected]
Tech Support: [email protected]
Morocco
M.I.T.C
Route de Nouaceur angle RS et CT 1029
Bureau N° 312 ET 337
Casablanca , Maroc
Phone : +212 663 72 73 24
Email: [email protected]
Lebanon RMA center
Dbayeh/Lebanon
PO Box:901589
Tel: +961 4 54 49 71 Ext:14
Fax: +961 4 54 49 71 Ext:12
Email: [email protected]
Bahrain
Technical Support: +973 1 3332904
Kuwait:
Technical Support: + 965 22453939 / +965
22453949
Türkiye Merkez İrtibat Ofisi
Ayazağa Maslak yolu
Erdebil Cevahir İş Merkezi No: 5/A Ayazağa /
Maslak İstanbul
Tel: +90 212 2895659
Ücretsiz Müşteri Destek Hattı: 0 800 211 00 65
Web:www.dlink.com.tr
Teknik Destek: [email protected]
Israel
' רח
המגשימים 20
קרית מטלון
ת "פ , 49348
. ד.ת7060
טלפון
: 073
-
277
-
11
-
77
אי-מאייל כללי
: [email protected]
אי-מאייל תמיכה
: [email protected]
Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link.
D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока.
Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через
Интернет.
Техническая поддержка D-Link:
+7(495) 744-00-99
Техническая поддержка через Интернет
http://www.dlink.ru
e-mail: [email protected]
Офисы
Украина,
04080 г. Киев , ул. Межигорская, 87-А, офис 18
Тел.: +38 (044) 545-64-40
E-mail: [email protected]
Беларусь
220114, г. Минск, проспект Независимости,
169 , БЦ "XXI Век"
Тел.: +375(17) 218-13-65
E-mail: [email protected]
Казахстан,
050008, г. Алматы, ул. Курмангазы, дом 143
(уг. Муканова)
Тел./факс: +7 727 378-55-90
E-mail: [email protected]
Узбекистан
100015, г.Ташкент, ул. Нукусская, 89
Тел./Факс: +998 (71) 120-3770, 150-2646
E-mail: [email protected]
Армения
0038, г. Ереван, ул. Абеляна, 6/1, 4 этаж
Тел./Факс: + 374 (10) 398-667
E-mail: [email protected]
Грузия
0162, г. Тбилиси,
проспект Чавчавадзе 74, 10 этаж
Тел./Факс: + 995 (32) 244-563
Lietuva
09120, Vilnius, Žirmūnų 139-303
Tel./faks. +370 (5) 236-3629
E-mail: [email protected]
Eesti
Peterburi tee 46-205
11415, Tallinn, Eesti , Susi Bürookeskus
tel +372 613 9771
e-mail: [email protected]
Latvija
Mazā nometņu 45/53 (ieeja no Nāras ielas)
LV-1002, Rīga
tel.: +371 6 7618703 +371 6 7618703
e-pasts: [email protected]
Usted puede encontrar actualizaciones de softwares o firmwares y
documentación para usuarios a través de nuestro sitio www.dlinkla.com
SOPORTE TÉCNICO PARA USUARIOS EN LATINO AMERICA
Soporte técnico a través de los siguientes teléfonos de D-Link
PAIS
NUMERO
Argentina
0800 - 12235465
Chile
800 - 835465 ó (02) 5941520
Colombia
01800 - 9525465
Costa Rica
0800 - 0521478
Ecuador
1800 - 035465
El Salvador
800 - 6335
Guatemala
1800 - 8350255
México
01800 - 1233201
Panamá
011 008000525465
Perú
0800 - 00968
Venezuela
0800 - 1005767
Soporte Técnico de D-Link a través de Internet
Horario de atención Soporte Técnico en www.dlinkla.com
e-mail: [email protected] & [email protected]
Caso tenha dúvidas na instalação do produto, entre em
contato com o Suporte Técnico D-Link por:
Chat Online
www.dlink.com.br/suporte
E-mail
[email protected]
Back Office
[email protected] *
*Acionar Garantia para 4 ou mais equipamentos
Telefones
São Paulo: (11) 2755-6950
*GO: 4052-1850 (Ligação local)
*Nordeste: 0800-7024104
*Demais Estados: 4062-1850 (Ligação local)
*Apenas Modems ADSL
Garantia diferenciada vendida pela internet. Agilidade e
tranquilidade para suas atividades!
Conheça: http://garantiapremium.dlink.com.br
Atendimento disponível das 9h as 21h de segunda a sexta
feira e aos sábados das 9h as 15h
D-Link 友訊科技 台灣分公司
技術支援資訊
如果您還有任何本使用手冊無法協助您解決的產品相關問題,台灣
地區用戶可以透過我們的網站、電子郵件或電話等方式與D-Link台灣
地區技術支援工程師聯絡。
D-Link 免付費技術諮詢專線
0800-002-615
服務時間:週一至週五,早上9:00到晚上9:00
(不含周六、日及國定假日)
網 站:http://www.dlink.com.tw
電子郵件:[email protected]
如果您是台灣地區以外的用戶,請參考D-Link網站全球各地
分公司的聯絡資訊以取得相關支援服務。
產品保固期限、台灣區維修據點查詢,請參考以下網頁說明:
http://www.dlink.com.tw
產品維修:
使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商。
Update perangkat lunak dan dokumentasi pengguna
dapat diperoleh pada situs web D-Link.
Dukungan Teknis untuk pelanggan:
Dukungan Teknis D-Link melalui telepon:
Tel: +62-21-5731610
Dukungan Teknis D-Link melalui Internet:
Email : [email protected]
Website : http://support.dlink.co.id
ディーリンクジャパン Web サイト
URL:http://www.dlink-jp.com
办公地址:北京市东城区北三环东路36 号 环球贸易中心B 座
26F 02-05 室 邮编: 100013
技术支持中心电话:8008296688/ (028)66052968
技术支持中心传真:(028)85176948
各地维修中心地址请登陆官方网站查询
网址:http://www.dlink.com.cn
办公时间:周一到周五,早09:00到晚18:00
All Countries and Regions Excluding USA
Print, type or use block letters.
Your name: Mr./Ms_____________________________________________________________________________
Organization: ________________________________________________ Dept. ____________________________
Your title at organization: ________________________________________________________________________
Telephone: _______________________________________ Fax:________________________________________
Organization's full address: ______________________________________________________________________
____________________________________________________________________________________________
Country: _____________________________________________________________________________________
Date of purchase (Month/Day/Year): _______________________________________________________________
Product Model
Product Serial No.
* Product installed in type of
computer
* Product installed in
computer serial No.
(* Applies to adapters only)
Product was purchased from:
Reseller's name: ______________________________________________________________________________
Telephone: _______________________________________
Answers to the following questions help us to support your product:
1. Where and how will the product primarily be used?
Home Office Travel Company Business Home Business Personal Use
2. How many employees work at installation site?
1 employee 2-9 10-49 50-99 100-499 500-999 1000 or more
3. What network protocol(s) does your organization use ?
XNS/IPX TCP/IP DECnet Others_____________________________
4. What network operating system(s) does your organization use ?
D-Link LANsmart Novell NetWare NetWare Lite SCO Unix/Xenix PC NFS 3Com 3+Open Cisco Network
Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000/ME Windows XP
Others__________________________________________
5. What network management program does your organization use ?
D-View HP OpenView/Windows HP OpenView/Unix SunNet Manager Novell NMS
NetView 6000 Others________________________________________
6. What network medium/media does your organization use ?
Fiber-optics Thick coax Ethernet Thin coax Ethernet 10BASE-T UTP/STP
100BASE-TX 1000BASE-T Wireless 802.11b and 802.11g wireless 802.11a Others_________________
7. What applications are used on your network?
Desktop publishing Spreadsheet Word processing CAD/CAM
Database management Accounting Others_____________________
8. What category best describes your company?
Aerospace Engineering Education Finance Hospital Legal Insurance/Real Estate Manufacturing
Retail/Chain store/Wholesale Government Transportation/Utilities/Communication VAR
System house/company Other________________________________
9. Would you recommend your D-Link product to a friend?
Yes No Don't know yet
10.Your comments on this product?
__________________________________________________________________________________________
__________________________________________________________________________________________